Manuscript Offprint
arXiv:2610.41415Beamfocusing Beyond the Near Field: Frequency Diverse Arrays for OFDM-ISAC Systems
Arda Akyazi*, Ahmed Hussain*, Asmaa Abdallah, Ahmed M. Eltawil, and Abdulkadir Celik
Abstract—Traditional phased arrays (PAs) achieve near-field (NF) beamfocusing through spherical wavefront curvature, but lose this range selectivity in the far field (FF). Frequency diverse arrays (FDAs) instead introduce frequency offsets across antenna elements. These offsets synthesize a range-dependent beam whose beamdepth is governed by the aggregate frequency-offset span rather than the physical aperture, thereby extending finite beamdepth into the FF. Although FDAs have been extensively studied for radar, their broader potential for wireless communications remains largely unexplored. Accordingly, this article examines how this capability can support wireless communications and integrated sensing and communication (ISAC). We compare PA and FDA focusing mechanisms, explain FDA coupling and periodicities, and assess coexistence with orthogonal frequency-division multiplexing (OFDM). Integer-multiple offsets preserve alignment with the OFDM subcarrier grid and avoid offset-induced intercarrier interference under ideal synchronization, but require suitable symbol mapping and receiver processing. We also distinguish FDA beamdepth from waveform-based radar range resolution and discuss their complementary roles in sensing. For the configurations studied, FDAs offer no additional single-user spatial degrees of freedom. Interestingly, their principal benefit is multiuser separation through location division multiple access (LDMA). Numerical case studies under an idealized FDA channel model show that FDA-LDMA achieves higher sum-rates than PA-based schemes for users with small angular separation in the FF, even after accounting for the bandwidth reserved for frequency offsets.
INTRODUCTION
BEAMFORMING with traditional phased arrays (PAs) has long been the cornerstone of directional wireless transmission that relies on plane-wave propagation to steer energy toward a specific angular direction. However, as physical apertures enlarge from massive to gigantic arrays, and operating frequencies extend into the millimeter wave (mmWave) and terahertz (THz) bands, the Rayleigh distance can span hundreds of meters. Consequently, communication may transition to radiating near-field (NF), wherein the incident wavefront is spherical rather than planar [1]. By matching the quadratic phase curvature across the aperture, the PA concentrates energy at a specific location in the NF region. This fundamental shift from angular beamsteering to beamfocusing endows the array with a finite beamdepth, thereby enabling a new multiplexing dimension such as location division multiple access (LDMA) [2]. However, the distance-dependent beamfocusing with a PA relies on wavefront curvature and is therefore confined to the NF, limiting its ability to provide distance-domain discrimination in the far-field (FF).
Unlike the PAs, the frequency diverse array (FDA) provides range selectivity even in the FF [3] by employing small frequency shifts across its antenna elements. Originally proposed for radar [4], the FDA has been extensively developed for range-dependent clutter suppression [5] and secure physical-layer transmission [6]. Moreover, FDAs differ from frequency-scanning arrays, which achieve beam steering through time-varying frequencies applied uniformly across all spatial channels. Architecturally, a PA requires a single local oscillator (LO) to provide the same carrier frequency to all elements, whereas an FDA requires additional mixer circuitry to transmit signals with different carrier frequencies. In a fully digital architecture, these offsets can be generated directly in the digital baseband without requiring separate analog circuitry.
Gigantic PAs exploit wavefront curvature in the NF to enable distance-domain multiplexing. In contrast, FDAs achieve beamfocusing in the FF by exploiting frequency offsets rather than relying on large antenna apertures. Although FDAs have been investigated for sensing and secure communications, their potential for spatial multiplexing remains largely unexplored. This motivates a unified comparison of PAs and FDAs across both the NF and FF. In this position paper, we first contrast their underlying beamfocusing mechanisms and examine the range-angle coupling and periodicities of the FDA beam pattern. We then investigate FDA–orthogonal frequency-division multiplexing (OFDM) architectures and their trade-offs in orthogonality, array gain, and bandwidth utilization, and discuss how FDA range selectivity complements waveform-based sensing in integrated sensing and communication (ISAC). Finally, we compare beamwidth, beamdepth, and single-user effective degrees of freedom (EDoF), and evaluate multiuser sum-rates while accounting for the bandwidth consumed by frequency offsets. This comparison identifies the conditions under which FDAs offer a net multiplexing gain and highlights future research directions in practical architectures, receiver processing, resource allocation, and physical-layer security.
Two Ways to Focus a Beam
Two ways of beamfocusing are contrasted side by side in Fig. 1(a) and (b).¹ An NF-PA leverages the array aperture to focus a beam. Its elements radiate at the same carrier frequency but with a progressive quadratic phase shift, causing the signals from different elements to interfere constructively at a prescribed focal point within the NF region. The resulting
*Arda Akyazi and Ahmed Hussain contributed equally.
¹We kindly refer readers to https://akadircelik.com/demos/fda-ofdm-isac/ for an interactive and accessible version of the figures.

Fig. 1: Architecture and focusing mechanism. (a) PA transmitter focuses by matching wavefront curvature, (b) FDA transmitter focuses by aligning carrier phases on a planar wavefront.
beam has a finite beamdepth that can be approximated as [7], where is the wavelength, is the focal distance, and is the maximum physical dimension of the array, such as the diagonal of a planar array. As increases, the wavefront curvature across a fixed aperture becomes weaker and the beamdepth broadens. Effective beamfocusing with a PA is therefore confined to a fraction of the Rayleigh distance, and extending the focusing range requires a larger aperture.
An FDA, by contrast, creates range selectivity through frequency-dependent phase accumulation rather than wavefront curvature. In a standard FDA, adjacent antenna elements transmit at frequencies separated by a fixed increment , introducing a range-dependent phase difference across the array. By appropriately configuring the initial phases, the signals from all elements can be aligned at a desired focal range, resulting in constructive interference. Away from this range, the accumulated phase differences cause the signals to become progressively misaligned, reducing the coherent array gain. Because this frequency-dependent phase term does not rely on wavefront curvature, it provides range selectivity in both the NF and the FF, irrespective of the Rayleigh boundary. In the FF, where curvature-based focusing vanishes, the FDA maintains a beamdepth of , governed by the aggregate frequency-offset span rather than by the physical aperture . The range focus is periodic, however, and equivalent focal ranges recur at intervals of .
Periodicities and Coupling
To expose the resulting periodicities and coupling, consider an M-element uniform linear array (ULA) at the base station
(BS) where its elements are indexed as . The -th antenna element transmits at an offset frequency . The frequency offset is a design parameter of FDA. For a standard linear FDA, . A single-antenna user equipment (UE) is located at range and angle relative to array broadside. Under a narrowband Fresnel approximation, the received phase contribution from element is given by [8]
where denotes time and is the element position relative to the array center. Setting leaves only the beamsteering and curvature terms and reduces the FDA to a conventional PA. In the NF, wavefront curvature enables beamfocusing, whereas in the FF, the curvature vanishes, leaving only angular beamsteering.
Figure 2 illustrates the coupling and periodicities produced by the first three terms of the phase equation above. The example uses a 128-element ULA operating at GHz and focused at with the linear profile and kHz.
a) Range-Angle Coupling: In case of standard linear FDA, the beamfocusing and the beamsteering terms are both linear in the element index. Consequently, an infinite number of range and angle combinations produce the same phase signature across the array. The maximum gain is therefore distributed along the S-shaped range–angle ridge in Fig. 2(a), rather than confined to a unique point.
b) Range Periodicity: As the observation range changes, the beamfocusing term causes the element contributions to move out of phase and subsequently realign. Complete realignment occurs whenever the range changes by , so the entire range-angle ridge repeats after this interval. For the parameters above, the period is m. Thus, the ridge passing through has a replica passing through , producing the two S-shaped maximum-gain loci in Fig. 2(b).
c) Time Periodicity: The first term evolves linearly with time and an element-dependent phase-rotation rate proportional to . Unlike the stochastic time variation caused by fading or physical Doppler, this programmed phase evolution causes the beampattern to periodically auto-scan across the range domain. At a fixed angle, the maximum-gain ridge moves outward at the speed of light and repeats every , producing the recurring trajectories shown in Fig. 2(c).
These replicas differ from PA grating lobes. Grating lobes arise from spatial undersampling, typically when the element spacing exceeds half a wavelength. FDA periodicity instead arises from the frequency-offset profile and therefore persists even with half-wavelength spacing.
Mitigating Coupling and Periodicities
The effects shown in Fig. 2 lead to distinct communication impairments. The range-angle ridge illuminates unintended

(d) Permuted offsets

(e) Range resolution
(f) Range replicas
Fig. 2: FDA beampattern top row, standard offsets: (a) range–angle at , (b) range–angle at with a larger range span, (c) range–time at ; Bottom row: (d) range–angle for the random-permutation design; (e) gain versus range across the mainlobe at and ; (f) the same cut over the full span.
locations, range replicas introduce spatial ambiguity, and temporal scanning produces intra-symbol channel variation. Each therefore requires a distinct mitigation strategy.
a) Range–Angle Coupling: A localized focal spot can be synthesized using nonuniform frequency-offset profiles, such as logarithmic assignments, but arbitrary frequency values generally do not lie on the discrete OFDM subcarrier grid. A practical alternative is to use linear frequency offsets that align with OFDM grid but randomly permute them across the array [3]. The permutation disrupts the element-wise linear progression responsible for the ridge (range-angle coupling) while preserving grid-aligned frequencies. It consequently transforms Fig. 2(a) into the localized spot in Fig. 2(d). Because the span of frequency offsets remains unchanged, the FF beamdepth, governed by , is also preserved, as shown in Fig. 2(e).
b) Range Replicas: The periodicity in range can be removed by using a nonuniform frequency-offset profile. For linear frequency offset profiles, range replicas can instead be placed outside the coverage region by selecting , where is the maximum operating range of the BS. Figure 2(f) shows the resulting trade-off. Increasing the increment from 60 to 600 kHz narrows the range response by a factor of ten, but also reduces the replica spacing from 5000 to 500 m. Thus, a larger offset span improves range resolution at the cost of a smaller ambiguity-free range.
c) Time Variance: The scan observed in Fig. 2(c) cannot be eliminated by attempting to synthesize a strictly time-invariant physical FDA beampattern [9]. In radar, its impact on time on target can be mitigated through wideband pulse-compression waveforms, such as linear frequency-modulated chirps [10]. In communications, a more useful remedy is to constrain the frequency offset to an integer multiple of the OFDM subcarrier spacing. The receive fast Fourier transform (FFT), evaluated over the useful symbol duration , then spans an integer number of offset cycles and orthogonally separates the shifted components. Under ideal synchronization, this avoids offset-induced intercarrier interference (ICI) and makes the post-demodulation channel on each subcarrier time-invariant, even though the physical beampattern continues to scan. The next section develops this FDA–OFDM integration in detail.
COEXISTENCE OF FDA AND OFDM
Since OFDM underpins contemporary wireless systems, compatibility with this waveform is essential to the practical adoption of FDAs. Understanding how antenna-level frequency offsets interact with the OFDM subcarrier grid is therefore crucial to assessing whether FDA range selectivity can be exploited while preserving reliable data transmission.


(c) Partial overlap

(d) Integer offsets

Fig. 3: FDA-OFDM architectures with frequency offsets applied across the antenna elements. denotes the data symbol on baseband subcarrier n and bin k denotes the receive FFT bin.
FDA-OFDM Architectures
An OFDM receiver uses an FFT to separate signals on equally spaced subcarriers. Each receive bin corresponds to one frequency on this grid, whose spacing is denoted by . Applying a frequency offset at an antenna shifts its entire subcarrier grid. The four panels of Fig. 3 illustrate how different subcarrier assignments and frequency offset profiles affect orthogonality, array gain, and bandwidth use.
a) Subcarrier Partitioned: Each antenna transmits a distinct subset of subcarriers as shown in Fig. 3(a), where the three antennas occupy separate frequency blocks, so each receive bin contains a symbol from only one antenna. This avoids overlap between antennas, but each symbol is transmitted by a single element and therefore receives no coherent transmit array gain. For physical-layer security, the subcarrier-to-antenna assignment can be changed from symbol to symbol while compensating the transmit phases toward the intended receiver. This preserves the desired symbol constellations in that direction while introducing varying phase distortions at eavesdroppers in other directions, making their data recovery more difficult [11].
b) Conventional (full overlap): All antennas transmit the same OFDM waveform with small frequency offsets, as shown in Fig. 3(b). When an offset is a fraction of the subcarrier spacing, the shifted tones no longer align with the receiver grid. Their energy leaks into neighboring FFT bins, which results in offset-induced ICI. As a result, conventional per-subcarrier equalization cannot directly accommodate the resulting intra-symbol variation.
c) Partial Overlap: Repeating data blocks across frequency allows copies of the same symbols from different antennas to overlap on selected subcarriers [12]. In the highlighted block of Fig. 3(c), all three antennas contribute the same two symbols with different precoding weights. These
contributions can combine coherently at each shared frequency, restoring array gain without frequency-offset beating between the co-frequency copies. In the FF, this coherent combination provides angular steering as in a PA; it does not retain the FDA range discrimination associated with combining different carrier frequencies. The repeated blocks also consume spectral resources that could otherwise carry new data.
d) Integer Offsets: Each antenna shifts its subcarrier grid by an integer number of spacings. For example, Fig. 3(d) uses for shifting successive antenna spectra by two bins. The tones remain aligned with the receive grid, preserving orthogonality and avoiding offset-induced ICI under ideal synchronization. Unlike panel (c), however, the highlighted bin contains different symbols: , , and . Thus, frequency alignment alone does not separate all antenna contributions; the symbol mapping, precoding, and receiver processing must account for their overlap. Copies of the same symbol occupy different frequencies and retain the frequency-dependent propagation phases that can be used for range-selective transmission. This architecture therefore provides the basis for the FDA-LDMA comparison developed in the next section. Integer offsets preserve compatibility with the OFDM grid, but introduce two practical costs:
• Data Bandwidth Contraction: For a fixed total bandwidth , the offset span leaves for the common data waveform. Larger offsets improve range selectivity but reduce the bandwidth available for data transmission.
- Edge Subcarrier Gain-Loss: Fewer antennas contribute to the outermost receive bins, as indicated by the elements per bin counts in Fig. 3(d). These edge bins therefore cannot provide the same array gain as bins shared by all antennas.

Fig. 4: Focal geometry and the spatial degrees of freedom: (a) beamdepth and the OFDM range resolution (left) and beamwidth (right) vs. focus distance, (b) the spectra vs. singular value index at four link distances, (c) the EDoF vs. link distance.
FDA–OFDM for ISAC
Originally introduced for radar sensing [4], FDAs are also relevant to future wireless networks that are expected to offer ISAC. The central question is therefore how FDA range selectivity can complement OFDM waveform-based sensing while preserving data transmission.
a) OFDM Radar Fundamentals: In monostatic sensing, where the transceivers are co-located, the receiver processes echoes using the known transmitted data. The phase progression across subcarriers reveals the round-trip propagation delay and hence the target range. On the other hand, the phase evolution across successive symbols reveals Doppler and thus radial velocity. For conventional radar processing over a contiguous bandwidth , the nominal range resolution is [13], independent of the target distance. Since the offset span is smaller than , the radar range resolution remains below the beamdepths of both the PA and FDA across the focal distances considered in Fig. 4(a). In contrast, the subcarrier spacing sets the delay-ambiguity interval: using every subcarrier on the uniform grid gives an unambiguous range interval of . These quantities answer different questions: bandwidth determines how closely spaced targets can be distinguished, whereas subcarrier spacing determines when delay signatures repeat.
Conventional FFT-based radar processing also requires the echo delay to fit within the cyclic prefix (CP), measured relative to the receiver's timing reference, to avoid intersymbol interference (ISI). A CP sufficient for the communication channel's multipath delay spread may therefore be insufficient for the desired sensing range. Note that this is a processing constraint, not a fundamental range-ambiguity limit. Meanwhile, choosing large compared with the expected Doppler shift reduces Doppler-induced ICI. With an unchanged CP and one Doppler sample per symbol, increasing shortens the symbol interval and expands the unambiguous velocity interval, but reduces the unambiguous range. Finer velocity resolution instead requires a longer coherent observation.
b) Complementary FDA Range Selectivity: Since OFDM radar separates echoes by propagation delay, an FDA addi-
tionally makes the array response range dependent through its antenna-level frequency offsets. Its transmit beamdepth describes spatial selectivity at a given time and angle, rather than the separation between two delay-resolved radar targets. The two measures should therefore not be equated. When is much smaller than the processed waveform bandwidth, waveform-based ranging can distinguish targets lying within the same broader FDA range-selective region. A similar distinction applies to NF-PA beamdepth [13]; there is no universal resolution ordering independent of bandwidth, aperture, and focal range.
With suitable waveform separation and joint range-angle processing, the range-dependent FDA response can help discriminate a target from clutter at other ranges, including clutter arriving from the same direction [8]. This benefit depends on the offset profile and receiver design, as range dependence alone does not guarantee clutter suppression or remove the periodic ambiguities discussed earlier. For communication, the same spatial selectivity supports the LDMA operation examined next.
FROM RANGE SELECTIVITY TO SPATIAL MULTIPLEXING
Having established how FDAs can coexist with OFDM, we now examine when their range selectivity translates into communication gains. Two distinct questions arise: can it support additional independent data streams within a single point-to-point link, and can it help separate multiple users that are close in angle but differ in range?
Single-User MIMO
Spatial degrees of freedom (DoF) represent the number of independent subchannels that can support parallel communication modes and, hence, multiple data streams. They are quantified by the singular values of the multiple-input multiple-output (MIMO) channel. For this comparison, modes with singular values above a prescribed threshold are counted toward the EDoF.
From an electromagnetic perspective, the EDoF represents the number of distinct transmit beams that can be spatially resolved by the receive aperture along a given spatial dimension, such as angle or distance. Accordingly, angular-domain and distance-domain multiplexing are fundamentally related to the beamwidth and beamdepth, respectively.
a) Angular Domain Multiplexing: Since beamwidth is determined solely by the aperture length in wavelengths, the PA and FDA exhibit almost identical beamwidths. As demonstrated in Fig. 4(a) for a 128-element ULA operating at 28 GHz, both arrays have the same beamwidth for a given aperture. In the FF, this results in an identical and constant angular EDoF under line-of-sight (LoS) conditions. As the UE moves closer to the array and enters the NF, however, the same angular beamwidth corresponds to a narrower physical footprint. Together with the spatial variation introduced by spherical wavefronts, this enables finer spatial resolution and, consequently, a substantial increase in the angular EDoF in the NF.
b) Distance Domain Multiplexing: In the FF, the beamdepth of an FDA is determined by the frequency offsets. In the NF, however, its beamdepth is governed jointly by the aperture-dependent and frequency-offset-dependent beamdepths. At short focal distances, wavefront curvature dominates the range selectivity, making the FDA beamdepth nearly identical to that of a conventional PA up to approximately 6 m, well within the effective beamfocusing Rayleigh distance (EBRD). As the focal distance increases beyond the EBRD, the FDA beamdepth approaches , whereas the PA beamdepth becomes unbounded [Fig. 4(a)]. The EBRD defines the maximum focal distance at which a PA can maintain finite beamdepth in the NF [7]. However, exploiting distance-domain EDoF in either the NF or FF requires the receive aperture to be oriented along the radial direction. Moreover, beamdepth is generally much larger than beamwidth when measured in physical distance [7], implying that resolving multiple distance-domain beams requires an impractically large receive aperture. Hence, practical array dimensions cannot resolve multiple distance beams, and the distance-domain EDoF remains limited to one in the FF.
Multiuser Multiplexing
State-of-the-art communication systems employing PAs in the FF exploit spatial division multiple access (SDMA) to separate UEs based on their angular direction. However, UEs at similar angles experience interference and cannot be simultaneously served through SDMA. In contrast, the spherical wavefronts in the NF enable beamfocusing in the joint angle-distance domain. This allows a PA to employ LDMA by simultaneously serving UEs located at the same angle but different distances. The LDMA capability of a PA, however, is limited to the EBRD of the NF, beyond which the beamdepth becomes unbounded. An FDA can overcome this limitation by enabling distance-domain multiplexing in the FF, owing to its finite beamdepth, as discussed earlier.
The reduced propagation distance in the NF also improves angular spatial multiplexing for both PAs and FDAs. Specifically, the physical beamwidth is approximately given by , where R denotes the radial distance and is the angular beamwidth in radians. Thus, for a fixed angular beamwidth, the physical beamwidth decreases at near ranges. Consequently, a sector can accommodate more resolvable beams at shorter ranges, enabling the NF to multiplex more UEs simultaneously.
The system bandwidth is also the data bandwidth for the PA. However, the FDA sacrifices for beamfocusing and is thereby left with a data bandwidth of (Section: Coexistence of FDA and OFDM). That is, is the beamfocusing cost and has a direct impact on the achievable rate of the FDA, which is studied in the case study below.
Case Study
This case study compares the EDoF and spatial multiplexing capabilities of the PA and the FDA. For the single-user case in Fig. 4, the BS is equipped with a 128-element ULA, while the UE employs a 64-element ULA. The OFDM parameters are: subcarriers, kHz, MHz, kHz ( MHz) with randomly permuted offsets. For the multiuser case demonstrated in Fig. 5, the same BS serves single-antenna UEs at high signal-to-noise ratio (SNR) with minimum mean-squared error (MMSE) precoding. The presented results are obtained by averaging over 3000 Monte Carlo trials.
a) Single-User: The multiplexing capability of the single-user case is characterized by the singular values of the channel matrix. The normalized singular values of are plotted at different distances in Fig. 4(b), wherein the normalized singular values above a threshold ( ) represent the EDoF. As the UE moves away from the BS, the EDoF count decreases and ultimately becomes one at about 10 m, which is close to the EBRD boundary. Next, the EDoF count is plotted against the link distance in Fig. 4(c), where it can be observed that the PA's and FDA's EDoF numbers are equal to each other both in the FF and in the NF, which supports the claims made in the Single-User MIMO subsection.
b) Multiuser MIMO: The multiplexing capability of the multiuser case is measured by the sum-rates. In Fig. 5, the total sum-rates are compared for SDMA and LDMA [2], [3] with PA and FDA. Following [3], we evaluate FDA-LDMA with an idealized narrowband channel model. This model assumes that each UE keeps the BS timing instead of synchronizing to its received signal, that the CP covers the propagation delay, and that the frequency-shifted copies of each symbol combine coherently across FFT bins. For benchmarking purposes, we also introduce the “No Overhead” case, where we hypothetically assume that bandwidth spread cost is free. In this way, we aim to show performance degradation caused by the bandwidth used for beamfocusing.
Fig. 5(a) presents the sum-rate as a function of distance for UEs uniformly distributed over the angular range . At short distances, PA-LDMA achieves a higher sum-rate because the PA provides a finite beamdepth that reduces inter-user correlation without requiring additional bandwidth. Beyond the EBRD, however, the PA loses its

Fig. 5: Total downlink sum-rate for SDMA, PA-LDMA, FDA-LDMA and the “No Overhead” ceiling. (a) Versus UE distance, with user ranges drawn from a window spanning m about each distance and a sector half-angle of . (b),(c) Versus sector half-angle, with ranges drawn from [3.5, 11.5] m in the NF and [86, 351] m in the FF.
ability to provide a finite beamdepth and its performance approaches that of SDMA. In contrast, FDA-LDMA maintains a finite beamdepth even in the FF. As a result, FDA achieves a higher sum-rate in the FF.
In Fig. 5(b) and (c), we evaluate the sum-rate as a function of the angular spread. In Fig. 5(b), the UEs are restricted to the NF region, with user distances uniformly distributed over m. In contrast, Fig. 5(c) considers UEs located in the FF region, with distances distributed over m. As shown in Fig. 5(b), operating below the EBRD allows the PA to generate a beamdepth comparable to that of the FDA without incurring additional bandwidth overhead. Consequently, the PA yields higher sum-rates than the FDA across the entire simulated angular sweep.
Conversely, Fig. 5(c) demonstrates that the PA loses its range selectivity in the FF, resulting in performance equivalent to standard SDMA. At very small angular spreads, where the UEs must be distinguished primarily in the range domain, the PA sum-rate falls to 0.2 Gbit/s. In contrast, FDA-LDMA achieves 2.3 Gbit/s by leveraging its frequency offsets. As the angular spread increases, the performance gap between the PA and FDA narrows because the PA increasingly exploits angular-domain multiplexing. Ultimately, in this configuration, the FDA achieves higher sum-rates for angular half-spreads below , which corresponds to a total sector angle of . Beyond this angular threshold, the UEs are sufficiently separated in the angular domain, and the bandwidth overhead of the FDA leads to lower sum-rates compared to the PA.
CONCLUSION AND FUTURE DIRECTIONS
This article compared PAs and FDAs in terms of beamfocusing, OFDM compatibility, and spatial multiplexing across the NF and FF. The PA has a finite beamdepth limited to the EBRD, whereas the FDA extends beamfocusing into the FF at the cost of additional bandwidth. For the configurations studied, both arrays offer approximately the same beamwidth and single-user EDoF. The main FDA benefit is instead
multiuser separation: FDA-LDMA improves the FF sum-rate in narrow angular sectors under the idealized channel model, while the offset-bandwidth cost favors the PA in the NF and wider sectors. Translating this benefit into practical systems motivates the following research directions.
Hybrid Architectures and Hardware Impairments
Hybrid architectures offer a route to lower hardware cost and power consumption. In a hybrid FDA, frequency offsets can be applied at the radio frequency (RF)-chain level, such that all antenna elements within a subarray share a common frequency offset. This reduces the number of independently controlled frequency offsets, but its impact on beamdepth, range replicas, and focal-point localization remains to be characterized. Moreover, phase noise and frequency errors can perturb the frequency-dependent phase profile, potentially shifting or broadening the focal region and thereby motivating dedicated calibration methods for FDAs.
FDA-Enabled ISAC
An FDA embeds range information into its transmit steering vector, thereby enabling a single waveform transmission to simultaneously support LDMA and distance-dependent sensing. Within the ISAC framework, the applied frequency offsets dictate both the communication bandwidth overhead and the sensing beamdepth. Consequently, jointly optimizing these offsets with standard OFDM parameters remains a critical, unresolved challenge. In this context, index modulation that conveys additional data bits through the dynamic selection of active frequency offsets offers a promising strategy to mitigate this bandwidth overhead and elevate overall spectral efficiency [14]. Furthermore, fusing traditional OFDM radar range estimation with the spatial selectivity of the FDA presents a promising mechanism to resolve the spatial ambiguities introduced by periodic range replicas [15]. Finally, extending these stationary designs to accommodate mobile UEs and dynamic targets, where the deterministic per-element phase drift heavily couples with the physical Doppler shifts, represents a complex but essential frontier for future research.
Frequency Offset and Waveform Design
The achievable sum-rate in FDA-LDMA systems does not scale monotonically with the bandwidth allocated to the array's frequency shifts. The optimal allocation is highly dependent on the spatial distribution and the total number of UEs. Because the relative penalty of the FDA frequency overhead diminishes as the total system bandwidth grows, adaptive bandwidth allocation emerges as an effective strategy to dynamically balance the superior distance-domain user separation of the FDA with the high raw data throughput of the PA. Looking forward, extending this multiplexing paradigm to planar arrays will require synthesizing multidimensional frequency-offset profiles capable of forming highly localized focal spots across range, azimuth, and elevation, while strictly adhering to the discrete OFDM subcarrier grid [8]. Finally, developing novel waveforms and symbol-to-antenna mapping schemes that mitigate edge-subcarrier gain losses, repurpose the offset bandwidth for active data transmission, and accommodate non-integer frequency offsets remain promising avenues for future research.
Physical-Layer Security
Frequency-to-antenna assignments offer security design opportunities in FDA-OFDM. Permuting grid-aligned offsets reshapes off-target responses without increasing the offset span. Joint permutation, precoding, and artificial-noise design may improve secrecy rates or artificial-noise jamming efficiency. Updating permutations may also hinder interception, but this uncertainty-based benefit can disappear if the eavesdropper learns the mapping or effective channel. Secrecy-capacity claims must therefore distinguish physical-channel advantages from mapping uncertainty. Neither permutation alone nor a fixed-time beampattern establishes secrecy. Permuting unchanged occupied frequencies also provides no inherent protection against wideband jamming. Future work should compare known, partially known, and unknown permutations using the complete received waveform, accounting for channel estimation, adversary capability, and coordination overhead.
REFERENCES
[1] A. Abdallah et al., “Exploring frontiers of polar-domain codebooks for near-field channel estimation and beam training: A comprehensive analysis, case studies, and implications for 6G,” IEEE Signal Process. Mag., vol. 42, no. 1, pp. 45–59, 2025.
[2] Z. Wu and L. Dai, “Multiple access for near-field communications: SDMA or LDMA?” IEEE J. Sel. Areas Commun., vol. 41, no. 6, pp. 1918–1935, 2023.
[3] H. Liu et al., “Distance-angle joint multiple access for far-field MIMO-OFDM via frequency diverse array,” in Proc. IEEE Int. Conf. Commun. Workshops (ICC Workshops), 2025, pp. 1001–1006.
[4] P. Antonik et al., “Frequency diverse array radars,” in Proc. IEEE Conf. Radar, 2006.
[5] Q. Kan et al., “Range-ambiguous clutter suppression for space-air bistatic radar based on FDA-MIMO,” IEEE Trans. Aerosp. Electron. Syst., vol. 62, pp. 7731–7746, 2026.
[6] J. Jian et al., “Physical layer security for frequency diverse array-based dual-hop spatial modulation,” IEEE Trans. Wireless Commun., vol. 22, no. 11, pp. 7565–7579, 2023.
[7] A. Hussain et al., “Analyzing URA geometry for enhanced near-field beamfocusing and spatial degrees of freedom,” IEEE Trans. Commun., vol. 74, pp. 8008–8024, 2026.
[8] B. Huang et al., “Frequency diverse arrays: Fundamentals, key insights, and future directions,” 2026.
[9] K. Chen et al., “Accurate models of time-invariant beampatterns for frequency diverse arrays,” IEEE Trans. Antennas Propag., vol. 67, no. 5, pp. 3022–3029, 2019.
[10] M. Zubair et al., “Frequency diverse array radar: New results and discrete Fourier transform based beampattern,” IEEE Trans. Signal Process., vol. 68, pp. 2670–2681, 2020.
[11] Y. Ding et al., “Frequency diverse array OFDM transmitter for secure wireless communication,” Electron. Lett., vol. 51, no. 17, pp. 1374–1376, 2015.
[12] M. Wachowiak et al., “Frequency diverse array OFDM transmit system with partial overlap in frequency,” in Proc. IEEE Int. Symp. Joint Commun. & Sens. (JC&S), 2026, pp. 1–6.
[13] A. Hussain et al., “Near-field ISAC: Synergy of dual-purpose codebooks and space-time adaptive processing,” IEEE Wireless Commun., vol. 32, no. 4, pp. 64–70, 2025.
[14] J. Jian et al., “FDA-MIMO-based integrated sensing and communication system with frequency offsets permutation index modulation,” IEEE Trans. Commun., vol. 72, no. 11, pp. 6707–6721, 2024.
[15] W. Chen et al., “FDA-based integrated sensing and multi-mode communication waveform design and receiver processing algorithm,” IEEE Trans. Wireless Commun., vol. 25, pp. 22782–22799, 2026.
Arda Akyazi is currently an undergraduate student at the Middle East Technical University, Ankara, Türkiye.
Ahmed Hussain is currently a Ph.D. student at King Abdullah University of Science and Technology.
Asmaa Abdallah received a Ph.D. in electrical engineering from the American University of Beirut, Beirut, Lebanon, in 2020. She is currently a research scientist at KAUST.
Ahmed M. Eltawil received a Ph.D. degree in electrical engineering from the University of California, Los Angeles, CA, USA, in 2003. He is currently a full professor at KAUST.
Abdulkadir Celik received a Ph.D. in double majors of electrical engineering and computer engineering from Iowa State University, Ames, IA, USA, in 2016. He is currently an associate professor at the University of Southampton.