arXiv:2610.41543cs.SDOct 2026

Manuscript Offprint

arXiv:2610.41543

ARPEGE: Dataset and Methods to Estimate Acoustic and Geometric Parameters of Rooms from Sound

Jean-Daniel Pascal Prieto, Prerak Srivastava, Cédric Foy, Antoine Deleforge

ABSTRACT

Can one hear the walls of a room? To foster audio signal processing research around this question we release ARPEGE1^{1}, a dataset containing hundreds of ambisonic spherical-array room impulse responses recorded in 6 empty rooms, annotated by the relative positions of sources, microphones and all acoustic reflectors. The dataset includes multiple room sizes, surface materials, orientations and distances, as well as recordings of human speakers and handclaps. Two state-of-the-art methods on image source localization and blind room-parameter estimation are demonstrated on the data. Initial code for re-simulating the measured room impulse responses is provided, a longer term goal being to digitally twin the dataset.

Index Terms— Room Impulse Response, Acoustic Reflector, Echo, Room Parameter, Digital Twin, Ambisonic

1. INTRODUCTION

Localizing and characterizing acoustic reflectors in an indoor environment from microphone recordings, sometimes referred to as “hearing the walls of a room” [1], is a topic that has received steady research interest along the past two decades [2, 3, 4, 5, 6, 7, 8, 9, 10] motivated by applications to spatial audio acquisition and reproduction [11], audio augmented reality [12], acoustic digital twinning [13], acoustic diagnosis [14] or simultaneous localization and mapping [15]. Yet, resources to evaluate and compare existing methods are scarce, due to the time and cost of obtaining high-quality labeled data on acoustic reflectors.

As a contribution to fill this gap, we introduce the ARPEGE dataset, standing for Acoustic Reflector, room ParamEter and Geometry Estimation. It consists of 248 spherical room impulse responses (RIRs) recorded using one loudspeaker and two ambisonic spherical arrays of respectively 32 and 64 microphones, placed in 44 positions across 6 empty rooms of different shapes and materials. The 3D device positions and room sizes are measured on site, while the array orientations are passively recovered a posteriori by leveraging direct-path times of arrival. This enables the labeling of each RIR in the dataset with the relative position of

Figure

Fig. 1. Examples of impulse response recording setups in the 6 rooms of ARPEGE, with the respective shoebox-envelope dimensions and reverberation times averaged over 4 octave bands from 500 Hz to 4 kHz ( RT‾60\overline{RT}_{60}).

not only the source, but also its corresponding image sources with respect to the receiver. Image sources are defined as synchronous, iterated mirror images of the true source with respect to the room boundaries [16]. Each of them manifests as a delayed and filtered copy of the original source impulse into the microphone signals – referred to as an echo – and provides an efficient, high-frequency, early-time approximation of the corresponding reflected propagation path. Detecting, localizing, pruning, and labeling image sources has formed a unifying, lowest common denominator for most of the literature in acoustic reflector characterization over the past decades, and is thus the primary focus of ARPEGE.

The dataset is designed to encompass a variety of scenarios, including multiple loudspeaker orientations, near- and far-field sources and reflectors, mixtures of up to two sources, and ad-hoc distributed arrays. In addition to RIRs, male and female speakers and handclap series were recorded from a subset of positions. To facilitate research, we release initial code to digitally twin the dataset, i.e., resimulate the scenes using the Pyroomacoustics implementation of the image source method [17] with the correct geometry and directive

1^{1}GitHub page: https://github.com/jdpascal/ARPEGE Zenodo page: https://zenodo.org/records/20096770

Table 1. RIR counts in ARPEGE, sorted by room, array type, source distance and source orientation (viewed from receiver).

source distancesource orientationroom 1room 2room 3room 4room 5room 6Total
em32em64em32em64em32em64em32em64em32em64em32em64
near(1.40m±4cm)front65868666646673
rear2120200020009
oblique107126126661046691
far(1.59m -4.84m)front12131300130015
rear12131300130015
oblique36393900390045
Total232327272727121223231212248

responses of devices. We also release scripts to evaluate two state-of-the-art methods on image-source localization [10] and blind room parameter estimation [7] on the data.

References (25)