arXiv:2610.41696cs.LGOct 2026

Manuscript Offprint

arXiv:2610.41696

From fleet trajectories to single-cell promises: hierarchically weighted conformal prediction for battery SOH monitoring

Xiangyu Liu

Abstract

Interval predictions from conformal prediction are usually read as “90% coverage”, but on nested battery data that number promises the fleet average, not the individual cell. We measure the gap on 124 public LFP cells under a preregistered three-tier reporting protocol (fleet, batch, cell): pooled coverage looks healthy (0.875–0.906 across splits) while the worst cell is covered 0.1–2% of the time, with exact binomial tests against the nominal level. We then repair part of the gap with a hierarchically weighted conformal engine whose weights consume only side information frozen at prediction time — signature features, batch labels, cycle indices — and never touch residuals. The preregistered repair criterion passes: 10th-percentile cell coverage moves 0.750→0.830 (53% of the gap), the worst cell 0.642→0.694, with zero deferrals and a flat sensitivity spectrum. What the engine does not repair is localized rather than left open: under protocol drift the frozen weights harm monotonically on the SOH scale (the absolute scale is reported in full), a structural dead end we report instead of tuning away; and repair capacity is bounded by calibration-pool battery diversity, measured on both datasets. On a cross-chemistry external set the calibrated intervals collapse (0.286), while the within-domain skeleton replicates (pooled 0.933, worst 0.686). The deliverable is a reporting protocol — three tiers of promise anchored to measured regimes, worst-cell statistics, deferral share — that makes per-cell interval claims auditable before deployment.

Keywords: Conformal prediction, State of health (SOH), Lithium-ion

Email address: tl_lucario@163.com (Xiangyu Liu) batteries, Uncertainty quantification, Battery degradation, Prediction intervals

0.1. Introduction

Grid-scale storage and electric-vehicle fleets have moved battery aging out of the laboratory and into operations. A state-of-health (SOH) number now sits inside decisions that carry price tags: warranty thresholds, capacity-fade alarms, module replacement scheduling, second-life triage. When a warranty reserve is priced from an SOH interval, the gap between fleet-grade and cell-grade coverage is a cash number, not a statistical nicety. None of these decisions consumes the point estimate alone. The operator's question is how wrong the number can be — an interval with a stated error rate, attached to the specific cell under watch.

Conformal prediction sells exactly that commodity without distributional assumptions: wrap any point predictor, calibrate on held-out residuals, emit intervals with a finite-sample coverage guarantee at a chosen level [1–3]. The deployment story is nearly frictionless — no retraining, no likelihood, one scalar q^\hat{q} for the whole fleet. The fine print is the guarantee's object. The nominal statement is about a draw from the calibration pool. A 90% guarantee at fleet level is compatible with one cell being wrong on most of its cycles. Maintenance decisions are cell-level. The headline number can be healthy while the decision-relevant quantity is broken.

Battery calibration data are not an exchangeable pool of independent draws. Cycles nest inside cells; cells nest inside manufacturing and fast-charging-protocol batches; aging and protocol changes both shift the residual distribution over the fleet's life. Within-cell correlation and batch structure inflate the effective sample size behind the pooled quantile, which then tracks the residual scale of typical cells and under-covers cells whose own scale is larger [4, 5]. This is not an implementation bug; it is the assumption behind the guarantee meeting the shape of the data. Two independent lines flag it as a live evaluation problem rather than a technicality: same-cell leakage — cycles of one cell straddling train and test — measurably inflates validation performance in the battery literature [6], and Gaussian-process posterior intervals inherit their σ\sigma from an optimizer whose failure is invisible in a coverage table (we measure this in §8.4).

We measure the gap, repair part of it, and map the boundary. On the public 124-cell LFP dataset of Severson et al. [7] — rebuilt from the original sources, including the documented re-run of five cells — we run standard split conformal and read coverage at three tiers: fleet, batch, cell (Fig. 1). The exhibit is stark and was preregistered as a two-panel gate. Under random splits, the regime where pooled coverage should hold, the fleet reads 0.906 against a 0.90 target, while 28% of cells fall below 0.85 and the median worst cell is covered 0.642 of its cycles (exact binomial, Bonferroni over cells, p=4×10−55p = 4 \times 10^{-55}). On the official split the worst cell is covered 1.4% of the time: a “90%” interval that is wrong 98.6% of the time for that cell. Under a protocol-drift split (train on 2017, test on 2018) the fleet number itself collapses to 0.799, and a permutation control attributes the deficit to exchangeability failure rather than sampling noise (recomposed splits cover 0.850–0.940, p<0.001p < 0.001).

We then repair what a side-information front-end can repair. The engine re-weights the calibration pool along the hierarchy — battery similarity, batch, trajectory position, per-cell balance cap — with every input frozen at prediction time and never touching residuals, the regime under which the weighted-exchangeability bound of Barber et al. [4] applies. One of three preregistered repair criteria passes: 10th-percentile cell coverage moves from 0.750 to 0.830, closing 53% of the gap to nominal; the batch tier recovers to 0.884; the fraction of cells below 0.85 halves; deferrals stay at zero and the sensitivity spectrum is flat across the whole tuning range. The two failures are localized rather than open. Under protocol drift the engine harms monotonically on the SOH scale (§8.3 reports both scales row by row) — a frozen-signature dead end, because repairing it would require weights that read residual scales, which is precisely what the freezing protocol forbids. On the official split the repair is capped by calibration-pool representativeness, and the engine’s own cap census says so.

The boundary is mapped on an external dataset: eight Oxford NMC-LCO pouch cells from a different laboratory, chemistry, form factor and load profile [8]. Cross-domain coverage collapses to 0.286, and the engine does not save it (0.376). Within-domain leave-one-out reproduces the collapse skeleton — fleet 0.933, worst cell 0.686. Two measurements on two datasets, the cap census on the main dataset and the pool ceiling on the external set, land on the same sentence: the repair capacity of hierarchical weighting is bounded by the diversity of batteries in the calibration pool, not by the number of cycles. A fleet that wants repairable per-cell promises should buy pool diversity, not cycle count.

Our contributions:

  1. A cell-level coverage benchmark on battery degradation data.

A three-tier reporting protocol (fleet / batch / cell) with a worst-cell exact binomial statistic, permutation attribution, and deferral disclosure. The collapse exhibit: pooled coverage 0.875–0.906 under near-exchangeable splits while the worst cell reads 0.014 (official split) and 0.001 (protocol drift).

  1. A hierarchically weighted conformal engine under a freezing protocol. Weights from side information available at prediction time; guarantee via the weighted-exchangeability bound; a preregistered partial repair (q10 0.750→0.830) plus two honest failures with located mechanisms (frozen-signature dead end under drift; calibration-pool representativeness ceiling).

  2. A four-arm comparison with ablations. Mondrian within-batch CP half-repairs — q10 is cosmetically restored while the worst cell does not move, the falsification behind the reporting protocol. GP posterior intervals are conservative by non-convergence, not by calibration; a Bayesian hierarchical comparator buys its coverage at 2× width. Feature families divide the labor across a coverage axis and a width axis.

  3. Boundary mapping. Cross-chemistry transfer collapse (0.286) reported as a measured limitation; within-domain skeleton replication across five simultaneous differences (chemistry, form factor, laboratory, load profile, time grid); the repair ceiling, measured twice, is the battery diversity of the calibration pool.

Section 2 positions the work against the conformal, hierarchical-conformal and battery-uncertainty literatures. Sections 3–7 set up the problem, data, engine, comparators and protocol. Section 8 reports; Sections 9–10 discuss and conclude.

References (23)