Manuscript Offprint

arXiv:2610.41835

ReuScope: Auditing Data Reuse and Evaluation Sensitivity in Capsule Vision 2024

Eunseob Choi, Kyeonghun Kim, Hyuk-Jae Lee, Nam-Joon Kim

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

We develop ReuScope, a protocol for auditing data reuse and evaluation sensitivity, using Capsule Vision 2024 as a case study. It combines measurements of data relationships with two comparisons: changing the evaluation population while holding predictions fixed, and changing training data while holding evaluation fixed. Byte-identical files cross the public training–validation boundary, and all 41 Kvasir-Capsule recordings that contribute frames occur in both partitions. Shared source recordings establish cross-split overlap; missing cross-recording patient identifiers prevent counting unique shared patients. Across ten paired seeds, removing all training rows attributed to Kvasir-Capsule, plus five rows from other sources flagged as near-matches to it, lowers public-validation balanced accuracy from 82.5% to 61.2%. Evaluating the same fitted models on the validation rows of the other sources reverses the comparison: removal improves balanced accuracy by 1.38 percentage points. The public-validation drop measures sensitivity to source removal, not an amount of leakage-induced inflation. Matched controls show that sample size and class counts alone do not explain the observed score differences. An exploratory experiment removes the training neighbors of validation frames that have close training matches, or equally many distant training rows, and yields a difference-in-differences estimate, relative to matched unflagged frames, of −0.355 percentage points in true-class probability; the paired-t interval for accuracy spans zero. The resulting procedure distinguishes observed reuse from conditional performance sensitivity and specifies the population, class support and uncertainty unit for each conclusion.

1 Introduction

A new filename does not imply new image content, a new source video or a new patient. In capsule endoscopy, neighboring frames can depict nearly the same scene, and identical files can occur under different names or labels. These relationships matter when public-validation scores are interpreted as evidence of generalization. Detecting reuse and identifying its effect on a score are nevertheless different tasks [Kapoor and Narayanan, 2023, Rumala, 2023]. Removing a source can reduce such reuse, but it also removes useful content and changes class support (rows per class), sample size and update count.

Capsule Vision 2024 (CV2024) was designed to support clinical frame review through ten-class abnormality classification and to encourage vendor-independent models [Handa et al., 2024]. Its public

*Corresponding author.

40th Conference on Neural Information Processing Systems (NeurIPS 2026). Track on Evaluations and Datasets.

release combines four acquisition sources and exhibits exact file reuse, shared videos, disagreement between released labels and source-dependent performance. The public validation split also matters beyond the challenge: EndoExtend24 reports organizer-evaluated CV2024 public-validation results alongside official-test results [Roth et al., 2024]. We ask whether the score change from removing a source keeps its direction across evaluation populations, and which matched controls are needed to interpret it.

The case reveals three challenges for auditing: different tests detect different data relationships; training contrasts can reverse across evaluation populations; and narrower interventions support narrower conclusions, each with its own population and uncertainty. We contribute the empirical CV2024 audit and ReuScope, the comparison and reporting protocol derived from its findings. Section 2 defines the comparisons, and Section 3 presents a public-file census, fixed-prediction diagnostics, matched training controls and a local-removal experiment. Section 4 specifies the protocol's comparison rules and reporting requirements.

Relationship to prior work. Leakage taxonomies and model information sheets relate data dependence to the population supporting a claim [Kapoor and Narayanan, 2023]; REFORMS extends this discipline to study design, uncertainty and reporting [Kapoor et al., 2024]. Visual audits characterize leakage by modality, coverage and degree [Ramos et al., 2025], while ciFAIR connects detection, adjudication, test-set replacement and reevaluation [Barz and Denzler, 2020]. Medical-image studies benchmark duplicate detection [Truong et al., 2024] and document repeated content and lost provenance across derivative datasets [Jiménez-Sánchez et al., 2024]. In endoscopy, EndoExtend24 propagates its revised 80/20 CV2024 split assignments to overlapping source images by filename [Roth et al., 2024]; content and video-prefix checks reveal relationships that filename matching alone cannot establish. Our audit makes matching rules, training changes and evaluation populations explicit, separating observed reuse from the score response to a specified change.

References (40)