arXiv:2610.41918cs.CYOct 2026

Manuscript Offprint

arXiv:2610.41918

A Multimodal Type 2 Diabetes Registry on DHIS2: A Design and Feasibility Study with the AI-READI Dataset

Saptarshi Purkayastha, Aiswarya Nandan Perumbilly, Zhenan Yin, Sherri L. Bucher

Saptarshi Purkayastha, Aiswarya Nandan Perumbilly, Zhenan Yin, and Sherri L. Bucher

Abstract—Care for type 2 diabetes increasingly draws on continuous glucose monitors, wearable devices, home sensors, clinical records and retinal images, yet few open platforms have been shown to hold all of these for the same person. We asked three questions of DHIS2, the open-source health information system that ministries of health in about 80 countries run nationally: whether an unmodified Tracker program can represent these modalities together (RQ1), which design choices its row-per-event data model forces for dense sensor streams (RQ2), and what a bulk loader must do to load such data correctly (RQ3). We designed a registry of 27 program stages and 445 data elements, loaded the AI-READI dataset of 2,280 participants into it, and verified the result field by field against the source files. The program held every loaded modality in 8.09 million events. Dense streams were stored as hourly summaries aligned across modalities; electrocardiograms, diagnoses and 118,480 retinal images were stored as one event per record. The event model ruled out storing raw readings, and hourly summaries reduced the wearable and glucose volume about 26-fold. An audit of the loader found defects that shared one pattern: a failure that looked like success. We state five lessons for DHIS2 Tracker clients that address this pattern. Verification of all 64.9 million stored values found four defects, all missing, duplicated or artifactual records rather than wrong values, and none after their repair; an independent recomputation of the glucose summaries agreed on all 464,210 values compared. The paper offers implementation guidance for DHIS2 implementers and for users of AI-READI; it does not evaluate clinical use. Analytics at this scale, use by clinicians and live device feeds remain to be shown.

Index Terms—DHIS2, diabetes registry, continuous glucose monitoring, wearable devices, multimodal data integration, OMOP common data model, retinal imaging, health information systems, data quality.

I. INTRODUCTION

TYPE 2 diabetes affects an estimated 589 million adults worldwide, most of them in low- and middle-income countries [1]. Behavior and environment shape its course alongside care in the clinic [2], and exposure to fine particulate air pollution, indoors as well as outdoors, is one such influence [3]. Many of these influences can now be measured. Continuous glucose monitors improve glucose control in type 2 diabetes [4], are recommended for a growing share of patients [5], and are read through consensus measures such as the share of time spent between 70 and 180 mg/dL [6]. Wrist-worn devices record heart rate, sleep and activity. Retinal photographs can be graded for diabetic eye disease by software [7] and carry signals about systemic disease [8], and small sensors log the air in a room. Few reports describe a system that holds these streams for the same person over time in a form that clinicians and community health workers can use.

DHIS2 (District Health Information Software 2) is an open-source platform that grew out of the Health Information Systems Program, a network that began in South Africa in the 1990s [9]. It was built for aggregate public health reporting and later gained a Tracker module for longitudinal, individual-level records [10]. Ministries of health in about 80 countries run it as their national health information system [11], [12], and Tracker has served as a national pregnancy registry [13], an electronic immunization registry [12] and the record of hypertension and diabetes programs [14], [15]. A platform with this reach is an attractive foundation for a registry that must outlive a single grant [16]. Whether its data model can hold dense sensor data, images and clinical records for thousands of participants, and what it takes to load such data correctly, has not been reported in the peer-reviewed literature (Section II-B). We address three questions.

RQ1 Representation. Can an unmodified DHIS2 Tracker program represent continuous glucose, wearable, indoor environmental, electrocardiogram, diagnostic and retinal imaging data for the same participants alongside the clinical record?

RQ2 Granularity and scale. Which design choices does the platform's row-per-event data model force when the sources are dense sensor streams, and what does the result cost in events and in information?

RQ3 Correctness. What must a bulk loader do to put millions of records into such a system correctly through its web interface, and does the loaded registry agree with its source?

We answer them in three steps, each applied to the AI-READI dataset [17], [18], a public, access-controlled collection of 2,280 participants across the spectrum of type 2 diabetes. First, we designed a registry data model that maps the modalities onto one Tracker program (RQ1, RQ2). Second, we loaded the dataset through the platform's web interface and audited the loader, deriving lessons from the defects found (RQ3). Third, we verified the loaded registry against the source

S. Purkayastha, A. Nandan Perumbilly and Z. Yin are with the Department of Biomedical Engineering and Informatics, Luddy School of Informatics, Computing, and Engineering, Indiana University Indianapolis, Indianapolis, IN, USA (corresponding author: S. Purkayastha, e-mail: saptpurk@iu.edu).

S. L. Bucher is with the Department of Community and Global Health, Richard M. Fairbanks School of Public Health, Indiana University Indianapolis, Indianapolis, IN, USA.

files, field by field (RQ3). The contributions are a tested Tracker data model for dense consumer-device streams; five lessons for loading data into DHIS2 Tracker correctly; and a verification method with an account of the loaded registry, including a catalog of the data quality of AI-READI as an ingestion pipeline meets it. A preliminary account of the mapping model, covering 23 stages and 152 data elements, was presented as a conference abstract [19]. The pipeline code, program metadata and verification scripts are public 1^{1}.

References (52)