arXiv:2608.23882eess.IVAug 2026

Manuscript Offprint

arXiv:2608.23882

Native-Space 3D CarveMix for Multi-Site T1w Stroke Segmentation

Dexter Wen Jie Teo, Kumaradevan Punithakumar

Dexter Wen Jie Teo 1,2^{1,2} and Kumaradevan Punithakumar 2^{2}

1^{1} College of Computing and Data Science, Nanyang Technological University, Singapore

2^{2} Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Canada

Corresponding author: WTE0030@e.ntu.edu.sg

Abstract. Segmenting ischemic stroke lesions on T1-weighted (T1w) MRI acquired across different scanners and protocols without intensity standardization is difficult because lesions are subtle and share intensity characteristics with cerebrospinal fluid. Standard deep learning architectures trained across multiple centers plateau around Dice 0.66, with acute lesions ( ≤\leq 7 days post-stroke) performing substantially worse due to severe sample scarcity. We combine a MedNeXt-L (k = 5) backbone with on-the-fly 3D CarveMix augmentation that pastes real lesion patches into healthy brain regions during training. By generating synthetic lesion placements dynamically within each fold with subject-level split isolation, the model sees more diverse lesion patterns without requiring pre-generated copies on disk. We evaluate on 1,453 native T1w scans from 55 clinical centers in the ISLES 2026 challenge. Our method achieves a mean 5-fold cross-validation Dice of 0.648 at 500 epochs, a +0.018 improvement over the MedNeXt-L backbone at a matched training budget (0.630).

Keywords: Ischemic Stroke Segmentation · T1-Weighted MRI · ISLES 2026 · 3D CarveMix · MedNeXt.

1 Introduction

Stroke remains one of the leading causes of death and long-term disability worldwide [1]. Precise delineation of stroke lesion volume and anatomical location is critical for predicting long-term functional outcomes and evaluating therapeutic efficacy in clinical trials [7]. In acute clinical settings, stroke diagnosis relies on multi-parametric MRI protocols, specifically Diffusion-Weighted Imaging (DWI) and Fluid-Attenuated Inversion Recovery (FLAIR), which provide high contrast for acute stroke lesions [2]. However, in large observational cohorts and retrospective neuroimaging datasets, DWI or FLAIR sequences are often unavailable [7]. In these cohorts, 3D structural T1-weighted (T1w) MRI is often the only modality available.

Automating lesion segmentation directly from multi-site T1w scans is therefore essential to unlock legacy datasets for retrospective research. Prior work

Teo and Punithakumar

on T1w-only stroke segmentation has evolved from classical feature-engineering approaches that plateau around Dice 0.40–0.50 [6] to modern deep learning networks, which typically report Dice around 0.60 on multi-center T1w benchmarks [7]. However, T1w lesion segmentation presents two major technical hurdles:

  1. Intensity Ambiguity: On single-channel T1w scans, ischemic lesions present as subtle hypointensities and tissue voids that blend into surrounding cerebrospinal fluid [6].

  2. Multi-Center Domain Shift: Scans acquired across disparate clinical centers vary in field strength (1.5T vs. 3T), head coil configurations, and pulse sequence parameters, creating substantial inter-site intensity variation [7,2].

Despite advances in 3D deep learning architectures, existing models struggle with acute lesions on unbalanced multi-center T1w benchmarks. The root cause is sample scarcity; acute cases are substantially underrepresented in the training distribution (see Section 3.1 for cohort statistics).

To overcome this plateau, standard preprocessing and architectural modifications are commonly attempted. We evaluated several conventional remedies and found that N4 bias field correction, Z-axis spatial coordinate channels, and FiLM metadata conditioning all failed to improve performance. Detailed ablation results are reported in Section 4.2. These results indicate that correcting scanner-induced intensity variation and providing explicit spatial coordinates does not close the gap — the bottleneck is sample scarcity, not preprocessing.

Because acute sample scarcity remains the primary bottleneck in native T1w stroke segmentation, we introduce an on-the-fly 3D CarveMix data augmentation pipeline [11] integrated into nnU-Net v2. During training, real 3D lesion patches are extracted from donor cases within the active training fold and grafted into healthy brain tissue of recipient scans using distance-transform edge blending.

By executing synthetic lesion placement dynamically during data loading, the network encounters continuous spatial and morphological lesion variations across training epochs. This dynamic formulation continuously expands sample diversity without the risk of cross-validation data leakage or disk storage expansion.

Our main contributions are:

– We demonstrate empirically that global intensity preprocessing (N4) and spatial coordinate channels (Z-grid) do not resolve the performance bottleneck on native T1w stroke scans.

– We implement an on-the-fly 3D CarveMix augmentation engine within nnU-Net v2 that dynamically grafts real lesion geometries into healthy tissue, maintaining strict subject-level isolation to eliminate cross-fold data leakage.

– We evaluate a MedNeXt-L (k = 5) backbone operating directly on raw native T1w scans, establishing a strong, reproducible benchmark for native-space stroke lesion segmentation.

Native-Space 3D CarveMix for Multi-Site T1w Stroke Segmentation

3