arXiv:2610.38207cs.LGOct 2026

Manuscript Offprint

arXiv:2610.38207

Progressive Coupling Method for Diffusion Posterior Sampling in Ptychography

Yihan Qiu, Mingtao Huang, Tianyuan Li, Shudong Li, Yuan Shen

Yihan Qiu, Mingtao Huang, Tianyuan Li, Shudong Li, and Yuan Shen

Abstract—Ptychography is a computational imaging method that reconstructs a sample from overlapping diffraction measurements. This technique relies on these overlapping measurements to provide the redundancy information needed for robust reconstruction, but dense scanning increases acquisition time and data volume. Reducing scan overlaps can improve measurement efficiency but weakens the physical constraints available for reconstruction. Diffusion models provide strong learned prior information, offering a promising approach to compensate for the loss of measurement redundancy. However, effectively utilizing this prior information under weak measurement constraints remains a challenge. We propose a progressive coupling posterior sampling (PCPS) method, which allows for a broader exploration of the solution space under high uncertainty while maintaining stronger diffusion-guided consistency as the reconstruction becomes more refined. Experiments on real X-ray ptychographic data at various scan overlaps demonstrate that PCPS consistently improves reconstruction accuracy compared to traditional iterative methods and existing diffusion posterior samplers, especially at low overlaps. These results show that diffusion priors can reduce the measurement redundancy required for accurate ptychography reconstruction.

Index Terms—Inverse problem, ptychography, diffusion model, posterior sampling.

I. INTRODUCTION

Ptychography is a computational imaging technique that reconstructs the complex transmission function of a sample from overlapping diffraction measurements [1]–[3]. The overlap between adjacent scan positions provides measurement redundancy that is essential for robust reconstruction. However, achieving high overlap requires dense scanning with small scan steps, resulting in more diffraction measurements, longer acquisition times, and larger data volumes. Reducing the scan overlap therefore provides a direct way to improve measurement efficiency by covering the same field of view with fewer scan positions. This efficiency comes at the cost of reduced measurement redundancy, which weakens the constraints on the inverse problem and makes accurate reconstruction increasingly challenging. Classical reconstruction methods, including projection methods, the extended Ptychographic Iterative Engine (ePIE), and least-squares maximum-likelihood reconstruction (LSQ-ML), rely primarily on the physical forward model and can degrade substantially in this low-overlap regime [4]–[7].

Diffusion models provide powerful prior information, offering a promising approach to compensate for the loss of measurement redundancy in low-overlap ptychography. To incorporate this prior information into the inverse problem, diffusion posterior sampling methods combine the learned image distribution with measurement information during inference. Diffusion posterior sampling (DPS) enforces measurement consistency during inverse diffusion and has been extended to ptychography reconstruction [8], [9]. A complementary hybrid approach, Ptycho-LDM, uses a conditional latent diffusion model to refine coarse Difference Map reconstructions obtained from reduced probe measurements [10]. Decoupled annealed posterior sampling (DAPS) enables broader exploration of the solution space by relaxing the dependence on the diffusion trajectory, which is particularly advantageous for complex nonlinear inverse problems [11]. DAPS++ further improves computational efficiency by separating prior-based initialization from measurement-driven refinement [12]. These advances highlight an important trade-off in diffusion-based reconstruction: more strict adherence to the diffusion trajectory preserves the learned prior structure, while greater deviation from the diffusion trajectory allows for a broader exploration of the solution space in the case of weak or ambiguous measurements.

Motivated by this trade-off, we propose progressive coupling posterior sampling (PCPS), which adapts the balance between measurement-driven exploration and diffusion-guided consistency over the sampling trajectory. At high noise levels, where uncertainty remains large, PCPS maintains greater freedom for measurement-driven exploration. As the noise level decreases and the reconstruction becomes more refined, PCPS progressively strengthens consistency with the diffusion trajectory to better preserve the learned structure. PCPS also naturally supports sparse sampling, enabling fewer sampling steps and lower computational cost. Experiments on real X-ray ptychographic data across different scan overlaps demonstrate that PCPS consistently improves reconstruction accuracy, with particularly clear advantages in the low-overlap regime.