arXiv:2610.38389cs.CVOct 2026

Manuscript Offprint

arXiv:2610.38389

Visually Irrelevant Hallucinations in Medical Vision-Language Models

Ke Zou, Nan Zhou, Tao Yang, Meng Liu, Linchao He, Zehui Liao, Ling Huang, Guangren Huang, Yidi Chen, Yi Zhang, Hu Chen, Huazhu Fu

Ke Zou, Nan Zhou, Tao Yang, Meng Liu, Linchao He, Zehui Liao, Ling Huang, Guangren Huang, Yidi Chen, Yi Zhang, Senior Member, IEEE, Hu Chen, Member, IEEE, and Huazhu Fu, Senior Member, IEEE

Abstract—Medical vision-language models (VLMs) have shown strong capabilities in radiology report generation (RRG) and medical visual question answering (Med-VQA), generating free-form clinical descriptions and answers from medical images. However, these models may generate clinically meaningful statements that are irrelevant to the visual evidence present in the input image. Such statements may lack sufficient visual grounding or contradict the observed image content. We refer to such errors as visually irrelevant hallucinations and investigate them at the phrase level. To detect these hallucinations, we propose CLEAR (Counterfactual Localized Evaluation of Alignment and Response), a model-agnostic post-hoc framework for phrase-level hallucination risk estimation. CLEAR first decomposes the generated response into sentence-level, visually assessable clinical phrases. For each phrase, phrase-conditioned grounding identifies a candidate visual region as an auditing target, which is selectively perturbed through localized counterfactual intervention. CLEAR then characterizes the intervention using two complementary auditing cues: response cues, capturing semantic and clinically meaningful changes in the generated response, and alignment cues, measuring changes in image–phrase compatibility. These cues are normalized and jointly modeled to estimate phrase-level hallucination risk. Across four datasets spanning RRG and Med-VQA, CLEAR consistently outperforms state-of-the-art hallucination detection baselines across multiple medical and general-purpose VLMs. For example, on MIMIC-CXR, CLEAR improves AUPRC from 85.10% to 90.23%. Its effectiveness is further validated on a GT-derived controlled VIH benchmark. These results establish visually irrelevant hallucination as an important fine-grained reliability failure mode in medical VLMs and demonstrate the value of model-agnostic visual-support auditing for more trustworthy multimodal clinical generation. Code is available at https://github.com/Zhounan1222/VIH

This work was supported by the Sichuan Provincial Natural Science Foundation under Grant 2026NSFSC0426.

K. Zou is with the Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119228.

N. Zhou, T. Yang, M. Liu, L. He, and H. Chen are with the College of Computer Science, Sichuan University, Chengdu 610065, China.

Z. Liao is with the Faculty of Information Technology, Monash University, Clayton, Victoria 3800, Australia.

L. Huang is with the Institute of Clinical Sciences, Imperial College London, London W12 0NN, UK.

G. Huang is with the Department of Radiology, Beihai People's Hospital, Beihai, Guangxi 536000, China. Y. Chen is with the Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi 530021, China.

Y. Zhang is with the School of Cyber Science and Engineering and the Key Laboratory of Data Protection and Intelligent Management, Ministry of Education, Sichuan University, Chengdu 610065, China.

H. Fu is with the institute of Advanced Intelligence and Computing, Agency for Science, Technology and Research (A*STAR), Singapore 138632.

Ke Zou and Nan Zhou are contributed equally to this work.

Hu Chen and Huazhu Fu are the co-corresponding authors (e-mail: huchen@scu.edu.cn, hzfu@ieee.org).

(a) Visually Irrelevant Hallucination

Figure

(b) CLEAR: Post-hoc VIH Auditing

Figure

Fig. 1. Motivation and overview of phrase-level visually irrelevant hallucination (VIH) detection. (a) A fluent VLM response may contain both visually supported and irrelevant clinical phrases, including positive and negative statements; therefore, response-level assessment cannot localize unreliable content. (b) Given the image I, query Q, generated response R, CLEAR performs post-hoc auditing and estimates a VIH risk for each atomic, visually assessable phrase SiS_i. The same formulation applies to both RRG and Med-VQA.

References (49)