Manuscript Offprint

arXiv:2610.38570

Do Audio LLMs HEAR Pain? Tracing Acoustic Evidence from Speech to Language Reasoning

Wenqi Li, Xiangjue Dong, Sulaiman Vesal

Abstract

Large audio language models (LALMs) can process speech directly, but it remains unclear how well they use the non-lexical acoustic information that speech carries. We study this question through pain, using TAME-Pain, which contains pain-neutral Harvard sentences and spoken pain ratings recorded at different self-reported pain levels. We introduce HEAR, a four-stage diagnostic framework that traces pain-related information from the speech signal to the model's prediction, and apply it to seven closed-source and open-weight LALMs. On the Harvard sentences, where pain can only be inferred from the voice, all models perform at chance level, and same-speaker references or few-shot examples improve balanced accuracy by no more than six points. On the spoken ratings, the same models reach 87.5–99.7% balanced accuracy. Layer-wise probing of open-weight LALMs shows that pain can be decoded from early audio representations (74.1% balanced accuracy for binary prediction and 45.0% for three-class severity), but that this information, along with most pain-associated acoustic cues, decreases in deeper layers. In an acoustic perception test, weaker models cannot distinguish even large changes in these cues, whereas stronger models can but still fail to infer pain. Finally, we recover pain-related acoustic cues and directly reinject them as structured text into the prompt, which improves pairwise pain prediction by up to 32 points. These results indicate that current LALMs encode paralinguistic information in early layers that is largely unavailable when the model produces its answer.

1 Introduction

Large audio language models (LALMs) are increasingly used as general speech interfaces, including in medical consultation and clinical decision support (Chen et al., 2026b; Tam and Chen, 2025). In

Figure

Figure 1: LALMs recognize pain when it is stated in words, but fail when it must be inferred from the voice. Examples from TAME-Pain (Dao et al., 2025), recorded during a pain-inducing cold pressor task. (a) Speakers read fixed, pain-neutral Harvard sentences, so pain is detectable only from the acoustic signal. (b) Speakers state their pain rating aloud, conveying pain both lexically and acoustically.

such settings, how something is said can matter as much as what is said (Kim et al., 2026a). However, LALMs are often evaluated on tasks where the words alone provide much of the information needed to answer correctly (Chen et al., 2026a). Strong results on these tasks therefore do not show whether a model uses the acoustic properties of speech, or mainly transcribes the input and reasons over its lexical content.

Pain is a clear case where this difference matters. Pain changes the voice, for example its loudness and pitch (Lautenbacher et al., 2017; Gonzales et al., 2025), and the voice can signal pain even when the words do not mention it. A model that relies on the words would miss exactly these cases. Prior work shows that LALMs rely mostly on lexical content for paralinguistic tasks such as emotion recognition (Chen et al., 2026a; Pang et al., 2026). It is still unclear why: is the acoustic information missing from the model, lost inside it, or present but not used?

We study this question with TAME-Pain (Dao

  • Equal contribution.

Figure

Figure 2: Overview of our HEAR analysis framework. (RQ1): we compare seven LALMs' pain prediction under the neutral-sentence and spoken-rating settings. (RQ2): we identify pain-associated acoustic cues and probe each layer of LALMs for pain representations. (RQ3): we test whether LALMs perceive large, controlled contrasts in these cues. (RQ4): we add acoustic cue values to the prompt as text.

et al., 2025), recorded during a pain-inducing cold pressor task (Figure 1). Speakers read pain-neutral Harvard sentences (IEEE Subcommittee on Subjective Measurements, 1969), so pain can only be inferred from the voice. They also state their pain rating aloud, so pain is directly inferable from the words. Comparing the two conditions separates acoustic from lexical evidence without editing the speech. Building on this comparison, we propose HEAR, a framework that analyzes pain-related information at four stages, following it from the input signal to the model's prediction (Figure 2):

  • RQ1 Behavior: Do LALMs recognize pain when it is conveyed only via the acoustic signal?

  • RQ2 Encoding: Is pain-related information present in the audio and in the model's internal representations, and at which stage is it lost?

  • RQ3 Perception: Can LALMs discriminate the acoustic cues associated with pain?

  • RQ4 Use: Can LALMs reason about pain when these cues are provided explicitly?

Across seven closed-source and open-weight LALMs, when pain is conveyed only via the acoustic signal, models perform near chance on predicting pain. Same-speaker references and 20-shot examples provide little improvement. When the pain rating is spoken explicitly, however, the same models approach ceiling performance (RQ1).

We then examine where this failure arises (Fig-

ure 2). Acoustic analysis shows that pain is associated with properties including loudness, pitch and spectral characteristics. In Qwen2.5-Omni-7B (Xu et al., 2025a), supervised probes recover pain information above chance from early audio representations, reaching 74.1% balanced accuracy for binary classification and 45.0% for three-class classification. Pain-related information becomes less decodable in deeper representations (RQ2), and the model is also near chance when directly asked to discriminate several pain-associated acoustic cues. Stronger models identify most changes but still fail to infer pain (RQ3). When the cue values are added to the prompt as text, pairwise pain prediction improves by up to 32 points (RQ4). These results suggest a gap between acoustic information represented inside the model and the information that remains accessible for downstream language-level reasoning. Our contributions are threefold:

  • We introduce HEAR, a controlled lexical-acoustic evaluation of pain understanding in LALMs, disentangling acoustic-lexical cues across pain-neutral utterances and explicit spoken pain reports.

  • We show a consistent gap between lexical and paralinguistic pain understanding in LALMs across seven closed-source and open-weight LALMs: models perform near chance when pain must be inferred from the voice, but approach

ceiling when it is explicitly stated in speech.

  • We trace how pain-related information and acoustic cues flow through open-weight LALMs, showing that they are most decodable in early audio representations and become less accessible with depth. We further show that reinjecting acoustic cues as text can improve pain prediction in within-speaker comparative settings.

References (47)