arXiv:2610.39045cs.AIOct 2026

Manuscript Offprint

arXiv:2610.39045

When Should AI Decide, Defer, and Deviate? Responsible Automation for Deceased Donor Kidney Allocation

Madeleine Pollack, Thomas Daillak, Mehmet Toner, Korkut Uygun, Heidi Yeh, Swati Gupta

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

We ask when an AI trained on historical decisions should be allowed to recommend decisions, defer to human experts, or in other cases, flag concerning patterns in data and deviate from past practice. This can be challenging because past decisions record what was done rather than what should have been done, and where data is sparse, a model's predictions may be too uncertain to act on. In this work, we provide a framework for addressing this problem using a case study in deceased-donor kidney allocation. Nearly 30% of kidneys recovered from deceased donors in the United States are never transplanted, largely because they are hard to place through the standard waitlist sequence. One can use AI to flag kidneys at risk of delayed or failed placement for out-of-sequence (OOS) allocation, but this comes at the cost of bypassing candidates higher on the waitlist. Thus, OOS allocation should only be used when the organ is demonstrably at high risk of discard on the standard sequence. Using Organ Procurement and Transplantation Network match-run data from 2016–2019 and 2023–2025 (excluding COVID-19-disrupted years), we build the Arbitrator framework, which combines various interpretable models and acts only when the uncertainty in their predictions cannot change the preferred action. Our Arbitrator resolves 93.5% of organ placement decisions using explicit medical criteria learned from data, and defers the remaining 6.5% to a human or a more complex model. We show that the Arbitrator correctly identifies 70.1% of historically discarded low-KDPI kidneys as OOS candidates, projecting that up to 43.9% of historically discarded kidneys could be flagged for expedited placement and potentially transplanted. We then exploit the interpretability of the Arbitrator to create an agentic audit comparing the learned rules to published clinical literature in order to flag decision-making patterns that are contentious. We discuss various future directions that stem from this advancement due to AI.

Keywords: organ transplantation; machine learning; uncertainty quantification; human–AI decision making; resource allocation

1 Introduction

In 2023, nearly 30% of kidneys recovered from deceased donors in the United States were not transplanted despite a persistent and overwhelming shortage of organs for patients with kidney failure [1]. The problem is not simply that all non-transplanted kidneys are medically unsuitable; rather, many of these organs are likely transplantable upon recovery [2], but deteriorate over the length of time required for an organ procurement organization (OPO) to find a suitable match for the organ [3; 4; 5].

Under OPTN policy, a deceased donor kidney in the United States is offered sequentially to compatible candidates in a priority sequence, or match run, determined by national allocation rules [6]. This sequence is designed to make the organ offer process systematic, fair, and auditable. However, if OPOs believe that sequential offering is unlikely to succeed by the time the organ expires, they may choose to expedite placement via out-of-sequence (OOS) placement [7; 8]. This creates a tradeoff: adhering to the match run risks nonuse of hard-to-place organs, while OOS placement bypasses candidates with higher priority, undermining the fairness the match run is designed to ensure. The concern that OOS allocation processes may be unfair is not unmerited: recent work has documented socioeconomic differences among recipients of OOS kidneys [7; 9; 10], and more work is needed to ensure OOS allocation is not exacerbating inequities in the healthcare system. A useful decision aid must therefore distinguish organs for which OOS allocation prevents nonuse from those easily matchable organs for which the standard sequence should be preserved.

Machine learning (ML) and, more broadly, artificial intelligence (AI) are attractive tools for this problem because donor profiles are high dimensional and organ acceptance reflects nonlinear interactions between clinical characteristics. Predictive models have already been developed for kidney discard, delayed placement, and offer acceptance [11; 12; 13; 14; 15]. But the barrier to responsible deployment is not predictive performance alone. In a qualitative study of 23 healthcare professionals considering AI-driven clinical decision support for resource allocation, Yüksel Elgin and Elgin found recurring concerns about the cost of increased efficiency in terms of equity, transparency and explainability. Participants also stressed the need for additional review and manual oversight of AI decisions and emphasized that AI should be used for decision support rather than a replacement for clinical expertise [16].

It is evident that in high-stakes decisions, a model with high predictive accuracy on past data does not imply that the model's learned behaviors are always worth replicating. AI models trained on historical outcomes can learn and reproduce the bias of the dataset when used for future high-stakes decisions [17], and historical organ allocation decisions themselves show socioeconomic disparities [7; 10]. Beyond bias, decision guidelines can also become outdated with new research and evolving transplantation policy, meaning that a good decision using the best available information ten years ago may differ from a good decision using the best available information today. These concerns motivate a shift from prioritizing accuracy in prediction to generating uncertainty-aware prescription. That is, AI models must support decisions about not just how to intervene, but also whether to intervene based on the model's limitations. Our work seeks to incorporate three relevant components when using AI to recommend kidneys for out-of-sequence allocation: interpretability, uncertainty-awareness, and

Figure

Figure 1: Our uncertainty-aware, auditable Arbitrator model. Each interpretable model certifies an action only when its confidence interval lies entirely on one side of τβ\tau_{\beta}. Organs with certified, non-conflicting actions are resolved; all others are deferred. An auditor (expert or language model) checks each resolved rule against clinical references and recommends deciding, deviating, or further deferring. XGBoost handles deferred organs.

validation from external evidence. These components are integrated sequentially in our framework in Figure 1.

First, we use interpretable1^{1} ML models to predict the probability that a deceased-donor kidney will be accepted by a patient on the match run within 100 offers. We call this outcome early-matchability (EM), and we recommend that OOS allocation be considered when an organ is not likely to be EM. Given a relative preference β\beta for maintaining the match run versus routing high-risk organs OOS, the optimal action is to send an organ OOS if its EM probability is at most τβ\tau_{\beta}.

However, a given ML/AI prediction is not guaranteed to be accurate, and different predictions can come with different levels of certainty based on the organ's features. Our models are uncertainty-aware, which means that the model abstains from making a decision if its confidence interval for the EM probability contains τβ\tau_{\beta}; that is, if the uncertainty in the estimated EM probability could change the recommended action. Otherwise, the model certifies either the on-sequence (OS) action (the full confidence interval lies above τβ\tau_{\beta}) or the OOS action (the full confidence interval lies below τβ\tau_{\beta}). Because we have multiple interpretable ML models, we use the Arbitrator decision rule to resolve their recommendations, submitting either a certified action or deferring the organs for additional review, which, in practice, can be done by humans. In this work, we defer the decision to a more powerful, but “black-box” XGBoost model.

Finally, because each model outputs a set of interpretable decision rules, we audit each resolved recommendation for alignment with published medical literature instead of blindly replicating historical decisions. This helps us identify problematic trends learned by AI models from historic data. Our agentic auditor can make one of three decisions: (1) provisionally retain the proposed optimal action (decide), (2) propose considering the opposite action due to medical research (deviate), or (3) request additional review for the model rule and recommendation due to insufficient evidence (defer). This model intends to maintain the parts

1^{1}We define an interpretable model as one whose predictions are defined by a decision rule, e.g., “if KDPI ≤x\leq x and creatinine ≤y\leq y and patient age is between z1z_1 and z2z_2, then predict class CC with probability pp.” of historical decision-making worth replicating, while allowing humans to intervene where historical biases, new research, or noise may render a specific recommendation too risky to automate.

References (43)