Abstract—In sampled cascade linear active disturbance rejection control (LADRC) of quadrotors, the extended-state observer typically receives the instantaneous command, although the delayed measurement reflects an earlier, rotor-filtered acceleration. This paper proposes actuator-aware (AA) observer inputs: altitude and attitude observers use limited virtual inputs filtered by an assumed rotor model and aligned with the measurement delay, and horizontal observers use acceleration reconstructed from measured attitude. Fixed gains are selected on the discrete-time model under sensitivity and step-response requirements and stationary covariance ceilings on each channel's control variance and increment and on the noise-induced inner-loop increment of the full cascade. In paired set-point trials, PID-Budget, AA-Budget and AA-HalfGain reach mean RMSEs of 65.5, 19.2 and 16.9 mm; under a stricter common cascade ceiling, the AA designs reach 29.9 and 26.4 mm versus 72.3 mm for a PID that uses roughly double their rotor-command increment. PX4 software-in-the-loop runs reproduce these results. Behind EKF2, a noise model fitted to the estimation errors predicts the roll/pitch and yaw increments within 5% on held-out and out-of-sample runs and the total rotor-command increment within 14%. Redesigned for this stack under the same sensitivity and response specification and estimator-aware ceilings, AA-Budget-E reduces the set-point RMSE from 59.1 mm (PID-E) to 44.0 mm with a lower rotor-command increment in every paired set-point and lemniscate run (mean S6 rotor-command-increment reductions relative to PID-E: 45% before and 15% after output quantization); AA-HalfGain-E beats PID-E only on the lemniscate. The evidence is simulation-based, and the ceilings are nominal tuning constraints.
Index Terms—Active disturbance rejection control, actuator dynamics, cascade control, extended state observer, quadrotor control, sensor noise, time delay.
I. INTRODUCTION
Quadrotor trajectory control couples disturbance rejection, sensor-noise sensitivity, actuator dynamics, and measurement timing [1]. Active disturbance rejection control (ADRC) estimates a lumped disturbance using an extended-state observer (ESO) and compensates for it in the control law [2], [3]. In a sampled cascade, however, the instantaneous commanded input may differ from the acceleration associated with a delayed measurement: rotor dynamics filter the command, and the measurement refers to an earlier plant state. Increasing observer bandwidth can then amplify both measurement noise and the residual caused by this input inconsistency.
This work addresses that implementation problem with two distinct observer-input paths (Fig. 1). For altitude and attitude, the controller reconstructs normalized inputs from the limited thrust and torque before rotor allocation, propagates them through a first-order actuator model, and aligns the result with the measurement time. For horizontal motion, the observer uses near-hover acceleration reconstructed from measured attitude rather than the instantaneous tilt command. The nominal model uses unity normalized input gain and separates the actual plant lag and delay from the internal observer assumptions. These choices do not reconstruct post-allocation rotor clipping or adapt the assumed delay during variable-latency tests.
Observer-input consistency is combined with fixed-gain activity-aware tuning. The sampled linear covariance model includes the closed attitude loop, its observer, actuator lag, and measurement buffers. It predicts tracking error, noise-induced virtual-control variance, and sample-to-sample increments. During horizontal gain selection, an additional inner-control increment ceiling includes the propagation of position and velocity noise through tilt commands. Sensitivity, overshoot and settling-time requirements constrain the same candidate search; the design target is , followed by a separate final audit against .
Actuator models in observers, delay alignment and half-gain tuning each have precedents; the contribution lies in two design concepts. First, observer-input consistency in a sampled cascade with rotor lag and measurement delay: a commanded observer input adds the structural residual (18) to the disturbance estimate, which raises the sensitivity peak with observer bandwidth at fixed controller bandwidth (Section V-B) and, in the redesigned ablation, allows the response and sensitivity requirements to be met, within the stated finite search, only at the lowest observer/controller ratios, where the best commanded-input design found for has 9.2 times the mean RMSE of AA-Budget (Section V-D). Second, the outer-to-inner noise path becomes an explicit design constraint: the cascade-level increment is predicted on the full cascade model, agrees with nonlinear hover measurements, and enables a comparison under a common strict cascade-increment ceiling (Section V-C); with a shaping filter for the estimation error, the same constraint is computed for estimator-fed loops (Section IV-G).
The main contributions are:
X.-Q. Dao and L.-M. Nguyen are with Eastern International University, Binh Duong, Vietnam (e-mail: quy.dao@eiu.edu.vn; minh.nguyenle@eiu.edu.vn).
- Two actuator-aware observer-input paths for sampled cascade LADRC, delay-aligned actuator-model inputs
N.-B. Le is with Industrial University of Ho Chi Minh City, Ho Chi Minh City, Vietnam (e-mail: lengocbich@iuh.edu.vn).
(altitude/attitude) and measured-attitude inputs (horizontal), with ablations of both input paths.
-
A fixed-gain covariance design whose channel-level and cascade-level activity ceilings are computed for white or estimator-coloured measurement noise, validated on code-generated controllers inside PX4.
-
A paired nonlinear simulation assessment including a comparison under a common strict cascade-increment ceiling, noise and latency stress, and fixed-gain rotor-lag mismatch, repeated in PX4 software-in-the-loop with the controllers code-generated into the autopilot, including a redesign for the estimator-fed loop under the same sensitivity and response specification and estimator-aware increment ceilings.
Tuning of ADRC and PID. Bandwidth parameterization reduces LADRC tuning to [3], and stability with uncertain dynamics was studied in [15]. Quadrotor studies automate tuning with Kriging surrogates [16], crayfish optimization with fuzzy adaptation [17], particle-swarm tuning with event triggering [18], TD3 reinforcement learning [19], and multi-objective PID optimization [20]. Their costs emphasize tracking and transients, in some cases with input-smoothness, power or acoustic terms [19], [20]; these objectives differ from the stationary sensor-noise covariance constraints on virtual-control variance, increments and the outer-to-inner noise path used here.
Noise-aware observers. The trade-off between observer responsiveness and measurement-noise sensitivity has been addressed through error-dependent observer bandwidth adaptation [21], [22], half-gain tuning of discrete-time ESOs [23], and scalable-bandwidth linear ESOs combined with internal model control for quadrotor attitude regulation [24]. These approaches modify the observer bandwidth or gain structure; the present work instead specifies the input and noise paths of a sampled cascade model and combines them with fixed-gain covariance constraints (Section IV). Two studies are closest in ingredients. Zhang et al. [25] place an actuator model inside the ESO, and Herbst and Hempel [23] derive half-gain tuning for discrete-time ESOs and validate it experimentally. The present work uses both ingredients and claims neither as new: the actuator-aware input is related to the model-based ESO, and the half-gain observer is adapted from [23]. What differs is the alignment of the modelled actuator output with the time base of the delayed measurement in a sampled cascade, the measured-attitude input of the horizontal observers, and the selection of fixed gains under cascade-level and estimator-aware increment ceilings, which neither study addresses. Their reported results are not directly comparable, because plants and objectives differ. Table I summarizes selected features.
III. QUADROTOR MODEL AND MEASUREMENT ASSUMPTIONS
The plant is a “+”-configuration quadrotor with the nominal parameters of [29] (Table II). Let denote the inertial position, the ZYX Euler angles, the body angular velocity, and the speed of rotor . The total thrust and body torques are
and the Newton–Euler dynamics are [1], [29]
Here , maps body to inertial coordinates, , , and is the ZYX Euler-rate map, defined for [29]. The wind velocity is ; (inertial) and (body) are external force and torque disturbances, and . The scalar in (1) is the thrust coefficient; subscripts elsewhere denote the sample index.
Unlike an ideal instantaneous actuator, each rotor is modeled by a first-order response from commanded to actual speed [30],
where is the rotor time constant. The commands are obtained by inverting (1) for the requested , followed by rotor-speed saturation.
Linearizing about symmetric hover, , gives and
with the same time constant for the small-signal torques. The first-order lag used below for the virtual thrust and attitude inputs is therefore a local approximation of the rotor-speed dynamics.
TABLE I SELECTED FEATURES OF RELATED METHODS
| Study | Method | Noise | Actuator dynamics | Delay | limit | Cascade path | Tuning/design | Validation |
|---|---|---|---|---|---|---|---|---|
| [5] | LADRC/GPI cascade | - | - | - | - | - | observer poles | flight |
| [16] | ADRC | - | - | - | - | - | Kriging surrogate | HIL |
| [17] | LADRC/fuzzy | - | - | - | - | - | modified crayfish | simulation |
| [19] | TD3-ADRC | - | sim. | - | - | TD3 | bench | |
| [25] | model-based ESO | - | yes | - | - | - | actuator-model ESO | simulation |
| [26] | RADRC/RESO | - | - | yes | - | - | delay synchronization | analysis |
| [27] | predictor/cascade ESO | yes | - | yes | - | - | PDE predictor/ESO | experiment |
| [11] | HOSM observer | - | yes | - | - | - | stability conditions | simulation |
| [24] | LESO/IMC | yes | - | - | - | - | scalable bandwidth | HIL |
| [22] | variable-bandwidth ESO | yes | - | - | - | - | error-adaptive bandwidth | spacecraft HIL |
| [28] | KF-tuned ESO | yes | - | - | - | - | noise-variance tuning | laboratory |
| [23] | half-gain ESO | yes | - | - | - | - | analytic half-gain | experiment |
| This work | AA cascade LADRC | yes | yes | yes | local+cascade | yes | constrained search | sim., PX4 SITL |
“Noise” denotes sensor noise explicitly considered in observer or tuning design. Actuator dynamics included in the design model. “Delay” denotes output or measurement delay and excludes delay internal to an actuator model. “Cascade path” denotes explicit propagation of outer-loop measurement noise through tilt commands into inner-loop control activity. Rotor lag is included as a simulation condition rather than as an explicit activity constraint in tuning. A control-magnitude term in the reward is not a sample-to-sample control-increment constraint. The FOPTD actuator model includes actuator time delay; this is classified under actuator dynamics rather than output/measurement delay. White measurement noise and estimator-coloured noise identified in PX4 SITL. Process (dead-time) delay of a first-order-plus-dead-time plant, equivalent to an output delay for the single-input single-output plant. Here, “-” denotes a feature not identified in the reported design; this does not establish that the feature is absent from the cited method. Because the studies differ in plants, objectives and conditions, the table is a feature-level comparison, not a performance ranking.

Fig. 1. Actuator-aware cascade LADRC (AA-Budget and AA-HalfGain). Online loop (dashed frame, every ): outer LADRC, tilt/thrust inversion with measured angles, inner LADRC, thrust/torque limits, rotor allocation with clipping, and the plant with rotor lag; blocks marked M read the delayed noisy measurement bus. Red blocks are the two observer-input paths: measured-attitude inputs for and the delay-aligned actuator model driven by the pre-allocation normalized inputs for . The offline design fixes the gains before the run and is not a feedback signal.
A. Sensors, delay and wind
Position, velocity, Euler angles, and body rates carry additive zero-mean Gaussian white noise, and the gyroscope also has a random-walk bias, following the stochastic sensor-error models of [31]. The controller reconstructs Euler rates as ; the independent Euler-rate noise of the hover covariance model is a local approximation of this transformation. All measurements, including the gyro bias, reach the controller after a common delay of samples that represents sensing, estimation, and computation latency; the history is initialized with the first measurement, and in (11) denotes the noise of the delayed sample available at
. Wind is a mean component plus independent first-order Gauss–Markov turbulence per inertial axis with correlation time , where is the scale-length-to-airspeed time scale of the Dryden spectrum [32]; the first-order form is a colored-disturbance surrogate applied to every axis rather than a full Dryden or von Kármán model; it enters through the drag term in (2).
B. Normalized channel model
As is standard in quadrotor cascade control [1], the outer loop generates the horizontal acceleration commands and and the vertical acceleration command , while the
TABLE II
NOMINAL MODEL AND SIMULATION PARAMETERS
| Parameter | Symbol | Value |
|---|---|---|
| Mass, arm length | m, l | 0.468 kg, 0.225 m |
| Thrust coeff. | k | N |
| Drag-torque coeff. | b | N |
| Inertia | kg | |
| Rotor inertia, linear drag | kg , 0.25 kg/s | |
| Rotor time constant | 30 ms | |
| Measurement delay | 5 ms ( , ms) | |
| Rotor / thrust limits | 1000 rad/s, 2mg | |
| Torque limits | (0.2, 0.2, 0.05) N m | |
| Noise std (pos., vel.) | 0.01 m, 0.02 m/s | |
| Noise std (angle, gyro) | 0.0035 rad, 0.005 rad/s | |
| Gyro-bias random walk | rad/s/ | |
| Mean wind | (1, 0.5, 0) m/s | |
| Turbulence | 0.5 m/s (z: 0.25), 1 s |
[29]; assumed in this study.
inner loop regulates the attitude . All controllers use the same command-to-force/attitude mapping. The requested thrust and body torque are
while the horizontal acceleration commands are converted to roll and pitch references using the near-hover small-angle inversion
The right-hand sides in (8) are clipped componentwise to rad. All angles in the implemented inversion are measured angles. Before rotor allocation, thrust and torque are limited as and , where . The actuator-aware inputs are
for , with , , and . This normalization neglects Euler/body-rate coupling away from hover. Rotor allocation and individual-rotor clipping follow these componentwise limits.
For observer design and bandwidth selection, each controlled coordinate is represented by the normalized second-order channel
where collects the unmodeled dynamics, coupling terms, and external disturbances, and denotes the acceleration generated by the actuator-mediated control input. At the controller sampling period , the measurement and actuator dynamics are represented as
(11)
where is the normalized input-gain ratio. The actuator recursion in (11) applies to ; the horizontal channels use the embedded attitude dynamics described below.
In the nominal covariance and actuator-aware design models, is set to unity; residual input-gain error is absorbed into . The corresponding rate measurement is subject to the same measurement delay.
For the horizontal channels, and are not produced directly by the rotors but through the closed attitude loop. Under the same near-hover approximation used in (8),
Hence, the outer-loop plant explicitly contains the inner-loop attitude response, which is the mechanism by which position-measurement noise can propagate through the commanded tilt into inner-loop control activity.
IV. PROPOSED ACTUATOR-AWARE CASCADE LADRC AND ACTIVITY-CONSTRAINTED TUNING
A. Reduced-order LADRC
Figure 1 summarizes the cascade architecture and the two actuator-aware observer-input paths. AA-Budget and AA-HalfGain share these input paths and differ in the observer gain structure described below.
Each LADRC channel employs a rate-aided reduced-order extended-state observer (RESO) to estimate the channel rate and lumped disturbance [2], [3], [7]:
(14)
where is the input supplied to the observer model. The corresponding LADRC law is
Here, and denote the controller and observer bandwidths, respectively. The derivative-reference and acceleration-feedforward terms in (15) are enabled for translational channels. The implemented attitude loops set both reference-derivative inputs to zero, including for time-varying commanded tilt. For fixed gains, the commanded-input and actuator-aware formulations differ only in the construction of .
B. PID baseline
The PID baselines use a two-degree-of-freedom law in the same channel coordinates, read the same delayed noisy measurement bus as the LADRC channels (no delay compensation), and share the command inversion, limits and mixer. With the reference and the measured rate (for attitude, the Euler rates ), each channel evaluates at sample k
(16) and then updates its states with the same sample:
(17)
where clips to , for , and : all controller states start at zero, and in PX4 they are reset while the vehicle is disarmed. The integrator stores the integrated unweighted error, and the derivative action uses the filtered rate of the previous samples. Because the proportional term acts only on , the integral action must supply in steady state; the clamp on is widened by exactly this share plus the disturbance allowance . The clamp is the only anti-windup mechanism: the integrator is not frozen when the tilt clipping of (8) or the thrust and torque limits before (9) are active. As for LADRC, the reference-derivative and acceleration terms are used in the translational channels and set to zero in the attitude channels. PID-Budget, PID-Budget-S, PID-E and the PID points of Fig. 3 use this law with different parameters ; the same function is called in the MATLAB simulation, the Simulink model and the code generated for PX4, and a sample-by-sample test reproduces the implementation exactly (pid_equation_check.m, output pid_equation_consistency.csv).
C. Actuator-aware, delay-aligned observer input (proposed)
In the conventional commanded-input formulation, the observer is driven by for altitude and attitude in the nonlinear implementation, with in the unsaturated nominal linear model. Under (11), however, the measured state at sample corresponds to the plant state at , whose acceleration is driven by the earlier actuator output rather than by the current command . Consequently, on the delayed measurement time base, the effective disturbance observed by the ESO is (in the nonlinear implementation with replaced by the limited input )
The first term is the physical lumped disturbance; the second is a deterministic residual caused by actuator lag and measurement timing. The commanded-input formulation therefore forces the ESO to estimate both, so that rotor dynamics and measurement timing are absorbed into the disturbance estimate. Increasing the observer bandwidth then forces the ESO to react more rapidly to this input mismatch as well as to measurement noise, which can increase control activity and erode closed-loop robustness.
For the altitude and attitude channels, the proposed actuator-aware formulation instead propagates the limited virtual command through an internal rotor-lag model,
where is the virtual input formed from the limited thrust or body torque before rotor allocation (9), and a short history buffer of provides the measurement-time alignment. The nominal implementations use ; A2-Unaligned uses .
Under the nominal small-signal model (11) with matched and , consistent initialization and no allocation-induced saturation, is the modeled virtual acceleration acting at the time of the delayed measurement. The ESO then need not absorb the nominal rotor lag or measurement-time offset, and its error dynamics recover those of the delay-free ESO on the delayed time base. Componentwise command clipping does not break this reconstruction because (19) uses the limited input; rotor-lag or delay mismatch, individual-rotor saturation, nonlinear allocation and cross-channel coupling do. The physical lag and delay remain in the feedback path, so their effect on robustness is screened separately through .
For the horizontal channels, the observer is driven by the near-hover horizontal-acceleration surrogate reconstructed from the measured attitude,
(20)
Because are delayed measurements of the realized attitude, these inputs implicitly contain the closed inner-loop and rotor dynamics and are aligned with the same measurement time base as the horizontal position observations. This measured-attitude construction avoids replacing the realized horizontal acceleration by the instantaneous outer-loop virtual command. The inputs (20) are near-hover acceleration surrogates reconstructed from the delayed attitude, not acceleration measurements; their accuracy degrades away from the small-angle regime of (8).
D. Discrete-time channel model
For each controlled channel, the sampled channel model in (11) is combined with the implemented controller and observer to form a discrete linear state-space representation. For the horizontal channels x and y, this representation additionally includes the complete closed attitude loop, including its controller, actuator lag, and measurement delay. The resulting model is written as
(21)
where is the perturbation state about a fixed reference and nominal hover (plant, actuator, observer, controller and delay states, excluding ), , and are row vectors. The matrices are extracted column by column from the same discrete update functions used in the nonlinear simulation, so the covariance analysis reflects the implemented controller.
The lumped disturbance is represented as a discrete random walk,
with zero-mean white and independent of the white measurement noise ; enters through (position and rate components and ); in the horizontal cascade model it enters the translational channel only. Translational states use a zero-order-hold acceleration, whereas the actuator retains the exact pole , so (21) is a sampled-data approximation tailored to the implemented controller. It excludes drag, nonlinear cross-axis coupling, saturation and gyro-bias dynamics; the predictions below are tuning constraints, not stochastic guarantees for the nonlinear plant.
E. Variances and noise-induced control-activity budget
Let
denote the covariance of the independent measurement-noise inputs in the nominal hover model; denotes the identity matrix, distinct from the physical inertia matrix . For a Schur-stable , the noise-induced steady-state covariance is the unique solution of the discrete Lyapunov equation
The corresponding tracking-error and control variances are
(24)
where the second term in accounts for direct measurement-noise feedthrough to the implemented control law.
To constrain rapid actuator-command variation, a further design metric is the variance of the sample-to-sample increment , whose differencing weight emphasizes high-frequency noise-induced activity. Using for the noise-driven model gives
(25)
where , , and are mutually uncorrelated under the white-noise model.
The lumped disturbance is modeled separately as the random walk , with . Because itself is nonstationary, Schur stability of alone does not give a finite tracking-error variance: the closed-loop dc gain from to must also vanish, so that the disturbance level does not appear in the tracking error,
This condition is checked numerically for every stable candidate retained in the tuning procedure. Defining
the disturbance-induced tracking variance is
It follows from the stable transformed state , which obeys with by (26); it measures the accumulated transient response to successive random-walk increments. Designs that violate (26) are not assigned a stationary disturbance variance.
F. Sensitivity and response requirements
Closed-loop sensitivity is evaluated only for Schur-stable candidates by injecting a perturbation at the virtual-input summing point and taking the total plant input as output. With all other exogenous inputs zero, define and , where ; equivalently with the loop gain broken at that point. is a per-loop SISO quantity: for and the attitude classes the loop is broken at the channel virtual input, and for at the outer virtual input with the designed attitude loop closed inside the cascade model. It is a sampled-loop sensitivity screen, not a MIMO singular-value margin, and it is not a proof of coupled MIMO or nonlinear robust stability. During the design search, is evaluated on a 600-point logarithmic frequency grid with local peak refinement, and final candidates on 4000 points (Appendix B). The tuning requirement is ; final candidates are audited against the reporting threshold .
The response requirement is evaluated on the nominal sampled closed-loop linear model of each class, for on the cascade model with the designed attitude loop closed inside. For the unit reference step over a 400-s horizon, the overshoot OS = 100 must not exceed 10% and the 2% settling time must not exceed and 5 s for . The settling bound prevents a loop that is too slow from passing the overshoot screen; both bounds were fixed before the redesigns reported in Section V. These linear screens do not bound arbitrary nonlinear transients. For the PID designs, the set-point weight is set per class to the largest value of the grid , not below the searched value, that meets the overshoot and settling requirements. For the and classes, whose references are exogenous, acts only on the reference response and, in the unsaturated linear model (where the clamp of (17) is inactive), leaves the loop, and the noise covariances unchanged; the attitude weights, whose reference is the noisy tilt command, would change the cascade covariance and are retained: the rule leaves them at their searched values in all three PID designs, and the recomputed , variances and increments are unchanged (setpoint_invariance.csv). For PID-Budget this raises from 0.19 to 0.35 (xy) and from 0.04 to 0.05 (). For PID-Budget-S and PID-E the overshoot limit is already active at the searched for the selected PID gains, so remains of order in several classes, and their tracking of moving references is limited by the response specification that is common to all designs.
For LADRC, in each symmetric channel class , the controller and observer bandwidths are se-lected to minimize the predicted steady-state tracking variance,
Here, and are the noise-induced standard deviations predicted by (24) and (25), respectively, whereas constrains the corresponding inner-loop control increment generated by noise propagated through the complete horizontal cascade. The local quantities and and their ceilings are always evaluated with the white-noise model of Table II; and use the noise model of the loop being designed, white for the MATLAB designs and estimator-coloured for the -E designs of Section IV-G; , OS and do not depend on the noise model.
The inner attitude and altitude classes are designed first; their closed-loop models are then embedded in the horizontal covariance model, so that the design includes the realized inner-loop dynamics. The search over and is summarized in Appendix B.
The control-standard-deviation ceilings are defined in normalized virtual-input coordinates. For the horizontal channels, the ceiling corresponds to a tilt-command equivalent. The altitude ceiling is 2% of the available thrust margin; the roll/pitch ceiling is 2% of a 0.41-Nm differential-torque reference; and the yaw ceiling is 2% of the yaw-torque limit. These normalized tuning limits differ from the physical 0.2-Nm roll/pitch torque limit: the and 2% levels are engineering-selected tuning budgets, not actuator limits. The local increment ceilings below are PID-referenced, and the random-walk intensities are engineering-selected weights of the variance objective, not disturbance statistics identified from the evaluation scenarios.
For each LADRC candidate, the local increment ceiling is referenced to the corresponding noise-induced increment obtained with PID-Budget. PID-Budget itself is the reference and is not constrained by it; A3 omits the local ceiling. Let denote the random-walk standard-deviation intensity for channel class , so that in (22) and (28). The values used for are
in force or torque per divided by mass or inertia.
For the horizontal design, the complete cascade model additionally exposes the inner virtual control as
Replacing in (25) with and using the full measurement-noise covariance , including position, velocity, attitude, and rate noise, yields the cascade-level increment prediction . This quantity captures the path by which outer-loop measurement noise propagates through commanded tilt into inner-loop control activity. It is imposed during horizontal reselection of the AA and ablation designs, all strict candidates and every budget-curve candidate, as a stationary nominal-hover tuning constraint rather than a bound on nonlinear rotor-command increments.
At zero-yaw hover, the symmetry of the model and gain selection gives identical one-axis covariance predictions for x/y and for roll/pitch. Accordingly, one representative channel is used for each symmetric class.
Two cascade thresholds are examined (Section V-C): the PID-referenced threshold is the inner-loop noise-only hover increment of PID-Budget, and a second, deliberately stricter common threshold, (strict), is defined from the isolated-attitude PID increment. It serves to compare the controllers under a common, tighter activity requirement, not to identify an optimal threshold. The reported parameters are the best feasible designs found by the stated finite search (Appendix B); no claim of global optimality is made.
G. Estimator-aware noise model
The ceilings above assume white noise at the controller input. When the controller is fed by a state estimator, in (21) is the estimation error, which is coloured and correlated across the measured signals. It is represented by a stationary shaping filter driven by unit white noise ,
which is appended to the channel state, :
and analogously for and . Equations (23)–(25) and (30) then apply unchanged with , because , and are again uncorrelated. With empty and the white-noise model is recovered (relative difference below for all reported designs). A measured signal that lags the true one, e.g. after a rate filter, keeps its own delay buffer in (21). The filter must be identified for the estimator and sensor configuration at hand; Section V-I identifies it from PX4 SITL logs. Because the estimation error also depends on the vehicle motion and hence on the controller, a filter identified with one set of designs is an approximation for another, and a new design can be followed by a refit. All identified filters are stationary (spectral radius of below one).
Delay convention. On the PX4 stack the three body rates are filtered and lag the plant by about 6 ms, whereas the EKF2 position, velocity and attitude estimates show no material lag (Section V-I). The models of the -E designs therefore keep a 6-ms buffer on all body rates and none on the other signals; this convention is used for , the step response and the covariances.
Rotor-command increment. With the hover-linearized “+” mixer, with , so
and the predicted increment of (34) is . The columns of are mutually orthogonal for the “+” configuration, so is diagonal and , : cross-covariances between the classes do not change (checked numerically on the logged SITL increments, where the linear formula reproduces within 0.06%).
Estimator-aware redesign. A design for an estimator-fed loop (suffix -E) follows four steps. (i) The ceilings are fixed before any redesign as the estimator-aware roll/pitch-cascade and yaw increments of PID-Budget, and , computed with the model pooled over the designs already logged. (ii) Each class is screened as in (29), with the delay convention above, , the response requirement, the white-noise local ceilings, and, for yaw, ; the altitude class has no estimator-aware ceiling, and a class of the nominal design that already meets these constraints is kept. (iii) The new designs are logged in noise-only hover, the pooled model is refitted with their logs, and the constraints are rechecked. (iv) If a constraint is violated, steps (ii)–(iii) are repeated, at most twice; otherwise the gains are frozen. Step (iii) tests whether the noise model used in step (ii) remains valid for the closed loops it produced.
H. Nominal candidates and implementation
Four nominal controller candidates are evaluated using the same nonlinear command inversion, rotor mixer, actuator dynamics, and sensor model. PID-Budget is a two-degree-of-freedom cascade PID baseline. AA-Budget uses the proposed actuator-aware LADRC formulation with regular reduced-order ESOs. RO-HalfGain replaces the regular observers with predictive half-gain observers while retaining commanded inputs for the altitude and attitude observers. AA-HalfGain combines the same half-gain observer structure with the proposed actuator-aware inputs. Both half-gain variants retain the measured-attitude input formulation for the horizontal observers. Because each candidate is independently tuned subject to the applicable activity constraints and sensitivity screens, their nominal comparison reflects complete controller designs rather than an input-only, fixed-gain ablation.
The PID-Budget gains are obtained by multistart optimization of the inner loops, followed by outer-loop and joint-cascade searches. The PID law is (16)–(17) (Section IV-B). Table III summarizes the design protocol, and Table IV reports the implemented gains.
I. Predictive half-gain observer adaptation
For the rate-disturbance model
the discrete-time half-gain pole placement of [23] is adapted here to the predictive observer timing used in the implementation. Let
The observer update is
(33)
These gains place the discrete observer-error poles at ; with the current-observer gain , the predictive form is . As , and , the reduced gains characteristic of the half-gain construction, whereas the regular RESO (14) keeps the forward-Euler bandwidth gains.
Equation (33) is a rate-aided predictive adaptation of the half-gain observer principle in [23], rather than a replication of the complete controller proposed therein. RO-HalfGain uses the commanded virtual input for the altitude and attitude observers, whereas AA-HalfGain uses the delay-aligned actuator-aware input in (19). Both variants use the measured-attitude formulation (20) for the horizontal observers and are tuned subject to the same local variance, control-increment, sensitivity, and overshoot constraints. AA-HalfGain additionally enforces the cascade-level inner-control increment constraint during horizontal bandwidth selection.
V. RESULTS
For an evaluation window containing N consecutive samples, the per-run metrics are
(34)
The reported rotor-command increment is the mean of the per-run values; it is an RMS increment in rad/s, not divided by , and differs from the noise-only virtual-control increment used in tuning. Across bounded runs, a mean RMSE confidence interval has half-width , where is the sample standard deviation; paired comparisons apply the same formula to within-seed differences of jointly bounded pairs. All nonlinear trials use the same 16-state rigid-body/rotor model, RK4 integration and controller/sensor period ms; scenarios S5 and S6 are defined in Appendix A. Nominal and ablation tests use thirty paired seeds 91001–91030, and budget curves the same thirty seeds at each level. Noise/latency tests use ten pairs 93001–93010 per condition; mismatch tests use ten pairs 92001–92010 per plant. At each seed, controllers share sensor samples, gyro bias and turbulence. A failure is a nonfinite state or any position component exceeding 50 m; statistics use bounded runs only. A rotor-fluctuation threshold exceedance is rad/s in a bounded run; failures and exceedances are disjoint counts. Bold entries mark results discussed in the text and do not imply statistical significance or an overall ranking.
A. Controller protocol and implemented gains
Tables III and IV specify the controller families and the gains used in all nominal nonlinear comparisons. PID-Budget retains its nominal gains except the set-point weights (Section IV-F); AA-Budget, AA-HalfGain, A2 and A3 undergo horizontal reselection with the cascade increment ceiling, as do the strict designs and every budget-curve candidate. The response requirement of Section IV-F is imposed on every design. Five initial designs violated it (PID-Budget-S, RO-HalfGain, A1-Commanded and the PID budget-curve points and 0.75) and were redesigned (Appendix B); all other designs satisfy it without change. RO-HalfGain and A1-Commanded are searched for every class on a grid of observer/controller ratios , with the primary cascade ceiling for . The nominal AA input models use ms and ; full-precision gains, including strict and budget-curve designs, accompany the code.
B. Actuator-input mechanism and nominal performance
Fig. 2 isolates the observer input at fixed bandwidths: with commanded inputs the roll-channel sensitivity peak grows with the observer/controller ratio and, for and 10 rad/s, the loop loses Schur stability, whereas with actuator-aware inputs the peak decreases with the ratio and the loop remains Schur stable. Table V compares the complete, independently tuned designs, so its differences combine the observer input, the feasible bandwidths and the activity constraints; the effect of the observer input itself is isolated by Fig. 2 and by the ablations of Section V-D. AA-Budget reduces mean position RMSE by 70.7% relative to PID-Budget while reducing measured rotor-command increments. AA-HalfGain gives a paired RMSE change of mm relative to AA-Budget, with a modestly higher increment. Among the searched candidates, RO-HalfGain meets the response and sensitivity requirements only with in the attitude class (Section V-D); it remains bounded but reaches 226.4 mm, mm above AA-HalfGain (all 30 pairs), which supports the role of actuator-input modeling within the half-gain observer family.
C. Comparison under a common strict cascade-increment ceiling
The primary cascade threshold, 1.382, is fixed from the PID-Budget roll-control noise-only benchmark rather than selected after observing the ADRC results, so that the reference is common to all designs. Table VI shows that the full-cascade model predicts the nonlinear hover increments with measured-to-predicted variance ratios of 1.001–1.003: position noise enters the inner loop through the commanded tilt. Because the primary AA designs reach only 0.937 and 1.023, this threshold does not bind them and cannot by itself show the value of the cascade budget. The strict threshold, 0.598, equals the isolated-attitude PID increment and lies below the primary increments of all three designs, which are therefore returned, including their inner loops. Under the same strict cascade-level increment ceiling, AA-Budget and AA-HalfGain achieve 29.9 and 26.4 mm, versus 72.3 mm for the returned PID (Table VII; paired changes and mm, better in all 30 pairs), and the PID uses roughly double their rotor-command increment (9.23 versus 4.67 and 4.71 rad/s). The ceiling imposes the same upper bound on the predicted roll/pitch cascade increment in noise-only hover, not the total rotor-command activity in disturbed tracking. All strict designs satisfy the local screens, the response requirement and their cascade ceiling, and their measured pooled hover increments stay below it. Relative to the primary designs, the strict AA designs accept a higher RMSE in exchange for lower measured rotor-command increments (4.67 and 4.71 versus 7.46 and 7.58 rad/s). This is evidence for a stationary matched-noise hover constraint, not a cap on rotor-command increments in disturbed tracking.
D. Redesigned ablations
A2 and A3 use twenty logarithmic ratios from 1.5 to 60 under the same local variance, sensitivity and response constraints and the primary cascade ceiling; A3 removes only the local increment ceiling. Inner gains are fixed while the horizontal design is reselected, and all final candidates are audited at full resolution; Table VIII reports the paired outcomes. With commanded inner/altitude inputs, the response and sensitivity requirements are met, within the stated finite search, only at the lowest observer/controller ratios: on the original grid, A1 is feasible in the attitude class only at its boundary , and RO-HalfGain not at all. With the ratio range extended down to (four further ratios, 1.0–1.36; lower ratios would no longer give an observer faster than the loop), the best commanded-input designs found for , A1 and RO-HalfGain, reach 176.6 and 226.4 mm, 9.2 times the RMSE of AA-Budget and 13.4 times that of AA-HalfGain, respectively; both use rad/s in the attitude class. As sensitivity checks, the A1 design of the original grid reaches 245.2 mm (12.8 times; 248.3 mm in PX4 SITL, ten seeds), and restricting the ratio to , where the observer is slower than the loop, gives feasible designs that are worse: 363.6 and 389.1 mm for A1 and RO-HalfGain (18.9 and 23.0 times AA-Budget and AA-HalfGain), worse in all 30 pairs. A2 changes the mean by only 0.013 mm at fixed 5-ms measurement age. Removing the local increment ceiling in A3 improves RMSE by 17.1% but increases measured increments by 10.7%, so the increment constraint regulates a precision/activity trade-off. The ablations combine architecture changes with retuning; their paired differences describe the resulting feasible designs. A4-CommandedTilt replaces the measured-attitude input of the horizontal observers by the commanded tilt and keeps the actuator-aware altitude and attitude observers. With the AA-Budget gains its sampled horizontal loop is not Schur stable, although the 30 nonlinear runs stay bounded at 129.1 mm; the best feasible horizontal design found on the stated grid, rad/s, reaches 275.7 mm, 14.4 times AA-Budget, worse in all 30 pairs (S5: 274.5 mm). Both input paths therefore materially improve the best-found tracking under the tested design procedure; replacing the measured-attitude input by the commanded tilt degrades the S6 RMSE to 275.7 mm after horizontal reselection.
TABLE III
CONTROLLER DESIGN PROTOCOL. THE FULL-CASCADE INCREMENT LIMIT APPLIES TO THE HORIZONTAL RESELECTION OF AA-BUDGET, AA-HALFGAIN AND A1–A3 AND TO THE STRICT AND BUDGET-CURVE SEARCHES; PID-BUDGET IS RETAINED AND AUDITED; RO-HALFGAIN AND A1 ARE SEARCHED IN ALL CLASSES. AA INTERNAL MODEL: 30-MS ROTOR LAG, 5-MS ALIGNMENT (A2: NONE). LIMITS: TARGET 1.98 (REPORTING 2), OS 10%, SETTLING OF SECTION IV-F.
| Controller | Architecture | Common constraints | Increment ceiling | Tuning |
|---|---|---|---|---|
| PID-Budget | 2-DOF PID | variance, , OS, | none | multistart + joint cascade |
| AA-Budget | actuator-aware RO-LADRC | variance, , OS, | PID local value | bandwidth/ratio selection |
| RO-HalfGain | commanded inner/altitude ESO | variance, , OS, | PID local value | predictive half-gain + bandwidth |
| AA-HalfGain | actuator-aware half-gain ESO | variance, , OS, | PID local value | predictive half-gain + bandwidth |
| A1-Commanded | commanded inner/altitude RO-ESO | same as AA-Budget | same | redesign |
| A2-Unaligned | lag-model RO-ESO, | same as AA-Budget | same | redesign |
| A3-NoIncrement | actuator-aware RO-ESO | same as AA-Budget | removed | redesign |
| A4-CommandedTilt | AA inner/altitude, commanded-tilt ESO | same as AA-Budget | same | fixed / horizontal redesign |
TABLE IV
IMPLEMENTED CONTROLLER GAINS: (A) PID OF (16)–(17), IN RAD/S, DIMENSIONLESS (RULE OF SECTION IV-F); THE HORIZONTAL GIVES (ONE-SAMPLE-DELAYED RATE); (B) LADRC () IN RAD/S; AND ROLL/PITCH SHARE GAINS. STRICT AND ESTIMATOR-AWARE GAINS: TABLE XVII.
(a) PID-Budget
| Class | |||||
|---|---|---|---|---|---|
| 4.465 | 3.358 | 3.215 | 15362.828 | 0.350 | |
| 19.460 | 32.427 | 6.990 | 21.076 | 0.353 | |
| 120.609 | 145.653 | 19.056 | 449.779 | 0.914 | |
| 32.212 | 68.577 | 9.880 | 34.865 | 0.050 |
(b) LADRC bandwidths () [rad/s]
| Controller | ||||
|---|---|---|---|---|
| AA-Budget | (2.057, 31.700) | (3.786, 43.466) | (10.426, 195.136) | (5.031, 74.498) |
| RO-HalfGain | (0.786, 38.859) | (1.258, 13.155) | (3.905, 3.905) | (1.258, 13.155) |
| AA-HalfGain | (2.154, 40.318) | (3.816, 56.503) | (10.908, 183.422) | (5.106, 95.563) |
| A1-Commanded | (0.760, 30.939) | (2.120, 18.252) | (3.905, 3.905) | (2.120, 18.252) |
| A2-Unaligned | (2.056, 31.698) | (3.882, 40.583) | (10.426, 195.150) | (4.969, 76.597) |
| A3-NoIncrement | (2.194, 27.854) | (3.889, 40.656) | (12.372, 190.707) | (4.974, 76.672) |

Fig. 2. Controlled roll-channel sweep of the observer/controller ratio at fixed controller bandwidths and 10 rad/s. Dashed: commanded input; solid: actuator-aware input. Peaks use 4000 frequencies plus local refinement; blank sensitivity segments correspond to non-Schur loops, whose loss of stability the spectral-radius panel shows.
TABLE V
NOMINAL SET-POINT PERFORMANCE (S6, 30 PAIRED TRIALS). IS THE PREDICTED HORIZONTAL TRACKING STANDARD DEVIATION OF THE LINEAR MODEL; RMSE IS THE MEASURED 3-D NONLINEAR POSITION ERROR. IS THE MAXIMUM OVER THE FOUR CHANNEL CLASSES; RMSE IS MEANSD AND CI IS THE 95% HALF-WIDTH OF THE MEAN.
| Controller | [mm] | meanSD [mm] | RMSE [mm] | CI [mm] | Inc. [rad/s] | Fail |
|---|---|---|---|---|---|---|
| PID-Budget | 132.9 | 1.978 | 65.57.0 | 2.62 | 9.91 | 0/30 |
| AA-Budget | 32.2 | 1.974 | 19.21.5 | 0.58 | 7.46 | 0/30 |
| RO-HalfGain | 300.5 | 1.963 | 226.413.4 | 5.00 | 0.80 | 0/30 |
| AA-HalfGain | 27.8 | 1.974 | 16.91.3 | 0.50 | 7.58 | 0/30 |
TABLE VI
CASCADE NOISE PREDICTION AND HOVER MEASUREMENTS. RATIOS ARE MEASURED/PREDICTED VARIANCES OF THE INNER VIRTUAL CONTROL AND ITS INCREMENT ; INCREMENT STANDARD DEVIATIONS ARE IN NORMALIZED ANGULAR-ACCELERATION UNITS. MEASUREMENTS: TEN PAIRED 60-S NOISE-ONLY HOVER TRIALS, WINDOW 20–60 S.
| Controller | Pred. | Meas. | Ratio | Ratio |
|---|---|---|---|---|
| PID-Budget | 1.380 | 1.382 | 0.998 | 1.003 |
| AA-Budget | 0.937 | 0.938 | 0.985 | 1.002 |
| AA-HalfGain | 1.023 | 1.024 | 0.982 | 1.001 |
E. Local budget–performance trade-off
For , PID, AA-Budget and AA-HalfGain candidates are redesigned with scaled local increment ceilings and compared on the same thirty exogenous realizations (Fig. 3). Each search includes its local-budget
incumbent and a finite ratio/bandwidth scan subject to the common cascade cap. Candidate lists are not nested, so small nonmonotonic changes are possible; the plateau represents the best candidates found by the stated procedure. The redesigned PID reaches 83.1 and 82.8 mm at and 0.75 and 66.4 mm for ; the latter point is the budget-curve

Fig. 3. Local budget-performance trade-off. Channel-local increment ceilings are multiplied by , while the variance, sensitivity, overshoot and main cascade ceilings stay fixed; thirty pairs per candidate, error bars are 95% CIs of mean RMSE. Left: imposed local multiplier; right: measured total rotor-command increment, which includes disturbance-rejection effort. The PID points at and 0.75 are redesigned under the response requirement (Appendix B); at the best PID candidate found keeps the attitude, horizontal and yaw gains of .
TABLE VII
CASCADE ACTIVITY CONSTRAINTS AND PERFORMANCE. PREDICTIONS USE THE STATIONARY LINEAR COVARIANCE MODEL; MEASURED VALUES ARE THE LARGER POOLED ROLL/PITCH INCREMENT OF TEN PAIRED 60-S NOISE-ONLY TRIALS (WINDOW 20–60 s); TRACKING METRICS ARE FROM 30 PAIRED S6 TRIALS. THE -S DESIGNS USE THE STRICT CEILING AND ALSO RETUNE THE INNER-LOOP GAINS.
| Design | Ceil. [rad/s ] | Pred. | Meas. | S6 RMSE [mm] | Rotor inc. [rad/s] |
|---|---|---|---|---|---|
| PID-Budget | 1.382 | 1.380 | 1.382 | 65.5 7.0 | 9.91 |
| AA-Budget | 1.382 | 0.937 | 0.938 | 19.2 1.5 | 7.46 |
| AA-HalfGain | 1.382 | 1.023 | 1.024 | 16.9 1.3 | 7.58 |
| PID-Budget-S | 0.598 | 0.592 | 0.592 | 72.3 7.5 | 9.23 |
| AA-Budget-S | 0.598 | 0.496 | 0.497 | 29.9 2.6 | 4.67 |
| AA-HalfGain-S | 0.598 | 0.521 | 0.522 | 26.4 2.3 | 4.71 |
TABLE VIII
OBSERVER AND BUDGET ABLATIONS (S6, 30 PAIRED TRIALS). LAST COLUMN: PAIRED RMSE CHANGE VERSUS AA-BUDGET, MEAN 95% CI HALF-WIDTH, THE CI ROUNDED TO TWO SIGNIFICANT DIGITS AND THE MEAN TO THE SAME DECIMAL PLACE. A4: AA-BUDGET WITH COMMANDED-TILT HORIZONTAL OBSERVER INPUTS. SAMPLED HORIZONTAL LOOP NOT SCHUR STABLE; THE NONLINEAR RUNS STAY BOUNDED.
| Design | RMSE [mm] | CI [mm] | Inc. | Paired change [mm] |
|---|---|---|---|---|
| A1-Commanded | 176.6 14.0 | 5.21 | 2.10 | 157.4 4.9 |
| A2-Unaligned | 19.2 1.5 | 0.58 | 7.70 | 0.0132 0.0034 |
| A3-NoIncrement | 15.9 1.3 | 0.47 | 8.25 | -3.28 0.11 |
| A4, fixed gains | 129.1 6.9 | 2.56 | 7.84 | 109.9 2.7 |
| A4, reselected | 275.7 42.2 | 15.75 | 7.16 | 256 16 |
candidate of the PID search, which has the inner, altitude and yaw gains of PID-Budget but horizontal gains reselected by the curve search versus 4.465, 3.358, 3.215, 15363 for PID-Budget), hence 66.4 rather than the 65.5 mm of PID-Budget in Table V (0.98 mm higher in all 30 pairs); both AA families are better than PID in all 30 pairs at every level (e.g., 37.2 and 34.3 mm at ).
F. Noise and variable measurement age
Table IX and Fig. 4 separate tracking from rotor-command activity. White sensor-noise standard deviations are scaled together; gyro-bias walk, wind, gains and internal lag/alignment remain fixed. Variable measurement age is either
round[5 + 5 sin(2πkT_s)] or fixed 5 ms with 200-ms bursts to 20 ms every 2 s from t = 10 s; a 31-column history selects the noisy sample at its acquisition timestamp. These tests record 0 failures in 240 realizations. Increased noise changes tracking much less than command increments, exposing activity costs concealed by RMSE alone. Both latency patterns are evaluated without adapting the measurement-time alignment.
G. Fixed-gain mismatch as a limitation
Nominal gains and internal are frozen. Linear screens sweep true lag 10–150 ms in 2.5-ms steps and integer delay 0–30 ms. Nonlinear tests use lags ms and delays ms, ten paired seeds per plant. Figure 5 reports the horizontal and roll/pitch sensitivity screens, Table X aggregates counts over twelve plants per range and controller, and Fig. 6 resolves the individual plants.
The two actuator-aware variants remain bounded with no threshold exceedance in the tested 15–60-ms plants. In the 75–120-ms range, AA-Budget has 7 failures and 93 bounded threshold exceedances; AA-HalfGain has 31 failures and 79 exceedances. AA-HalfGain has the lowest mean RMSE among the four primary designs in S6 and S5, but AA-Budget has fewer failures under the tested large rotor-lag mismatch, so the nominal advantage of the tuned half-gain design does not imply uniformly improved robustness. PID-Budget records 30 failures and 0 bounded threshold exceedances in the outer lag range; its sampled linear margin is larger over part of the grid, yet nonlinear failures occur at the highest lag/delay combinations. Robust redesign over an uncertainty set is the subject of a companion study.
H. Paired lemniscate tracking
Table XI reports the trajectory statistics. The horizontal reference starts at s with a velocity step from zero to m/s on both axes, with unchanged velocity and acceleration feed-forward for every controller. Because the S5 metric window starts at 5 s, its maximum error includes the transient caused by this velocity jump. AA-Budget and AA-HalfGain keep the set-point ranking on the moving reference (22.7 and 20.4 mm versus 276.5 mm for PID-Budget). The PID error
TABLE IX
NOISE AND LATENCY STRESS TESTS (S6, TEN PAIRED TRIALS PER CONDITION). RMSE ENTRIES ARE MEAN±SD; BRACKETS CONTAIN ROTOR-COMMAND INCREMENTS. RO-HALFGAIN: DESIGN WITH .
| Condition | PID-BudgetRMSE [mm] [rotor-command increment, rad/s] | AA-Budget | RO-HalfGain | AA-HalfGain |
|---|---|---|---|---|
| Reference | 68.3±7.6 [9.91] | 19.6±1.3 [7.45] | 227.4±19.4 [0.79] | 17.2±1.1 [7.57] |
| Noise 0.5× | 68.4±7.6 [4.96] | 19.6±1.3 [3.73] | 227.5±19.4 [0.40] | 17.2±1.1 [3.79] |
| Noise 2× | 68.3±7.6 [19.84] | 19.7±1.3 [14.92] | 227.3±19.3 [1.59] | 17.3±1.1 [15.15] |
| Noise 4× | 68.3±7.7 [39.76] | 20.0±1.2 [29.91] | 227.2±19.1 [3.18] | 17.7±1.0 [30.39] |
| Delay 0–10 ms | 68.3±7.6 [9.86] | 19.6±1.3 [7.42] | 227.8±19.4 [0.79] | 17.2±1.1 [7.53] |
| Delay bursts 20 ms | 68.3±7.6 [9.91] | 19.6±1.3 [7.45] | 228.3±19.1 [0.80] | 17.2±1.1 [7.57] |

Fig. 4. Noise-mismatch effect in S6. Tracking and measured rotor-command increments are shown separately for PID-Budget and the two actuator-aware variants.

Fig. 5. Fixed nominal gains under true lag and measurement-delay mismatch; internal model stays fixed. Left: true rotor time constant varied at the nominal 5-ms delay; right: true delay varied at the nominal 30-ms time constant. Missing sensitivity values are non-Schur sampled loops. The horizontal line is the reporting limit 2.
TABLE X
FIXED-GAIN MISMATCH OUTCOMES (TWELVE PLANTS PER LAG RANGE, TEN PAIRED S6 TRIALS PER PLANT). THRESHOLD COUNTS BOUNDED RUNS WITH ROTOR FLUCTUATION ABOVE 20 RAD/S; FAILURES ARE COUNTED SEPARATELY.
| Controller | Lag [ms] | Runs | Fail | Threshold |
|---|---|---|---|---|
| PID-Budget | 15–60 | 120 | 0 | 0 |
| PID-Budget | 75–120 | 120 | 30 | 0 |
| AA-Budget | 15–60 | 120 | 0 | 0 |
| AA-Budget | 75–120 | 120 | 7 | 93 |
| AA-HalfGain | 15–60 | 120 | 0 | 0 |
| AA-HalfGain | 75–120 | 120 | 31 | 79 |
on this reference depends on the set-point weight: with the searched weights of and before the rule of Section IV-F, PID-Budget reaches 339.0 mm in S5 for an unchanged S6
TABLE XI
LEMNISCATE TRACKING PERFORMANCE (S5, 30 PAIRED TRIALS, WINDOW 5–45 s). ENTRIES ARE MEAN±SD; MAXIMUM ERROR IS THE PER-TRIAL MAXIMUM 3-D POSITION-ERROR NORM.
| Controller | RMSE [mm] | 95% CI [mm] | Inc. [rad/s] | Max. error [mm] | Fail |
|---|---|---|---|---|---|
| PID-Budget | 276.5±7.7 | 2.88 | 9.92 | 464.0±32.0 | 0/30 |
| AA-Budget | 22.7±1.7 | 0.64 | 7.46 | 94.9±14.5 | 0/30 |
| RO-HalfGain | 217.3±16.2 | 6.04 | 0.79 | 641.2±86.6 | 0/30 |
| AA-HalfGain | 20.4±1.5 | 0.55 | 7.58 | 91.6±13.2 | 0/30 |
RMSE, because the term acts as a reference-proportional disturbance that the integrator must remove. The weights follow the same declared rule for all PID designs, so the S5 result characterizes PID designs selected under the

Fig. 6. Per-plant counts out of ten paired S6 trials: failure plus bounded rotor-fluctuation threshold exceedance; each nonzero cell is annotated F/E with the failures F and the bounded exceedances E, which are disjoint events. This diagnostic does not label every threshold exceedance a self-excited oscillation.
common response specification, not the best trajectory tracking attainable with a PID structure.
I. PX4 software-in-the-loop check
The designs were also run in PX4 v1.16.1 software-in-the-loop (SITL): the controller functions were code-generated with the UAV Toolbox Support Package for PX4 and executed every 1 ms inside PX4 (its multicopter controllers disabled), with unchanged gains and internal models, but fed by the EKF2 position, velocity and attitude estimates and the filtered gyroscope rate. The plant of Section III, with the wind, torque and gyro-bias sequences of the same seeds, runs in lockstep with PX4 over MAVLink and supplies 1-kHz inertial samples (gyroscope as in Table II, accelerometer noise 0.05 m/s²) and 100-Hz motion-capture-like pose and velocity samples with the noise of Table II and a 5-ms latency; PX4 returns actuator outputs quantized to 1/1000 of full scale (1 rad/s in ). The 1-ms lockstep execution checks the generated code and the estimator interface; it is not evidence of execution time on flight hardware.
(i) Tracking. Table XII compares the SITL runs with the MATLAB results of the same seeds. In S6, AA-Budget improves on PID-Budget by mm and AA-HalfGain on AA-Budget by mm, and under the strict ceiling AA-Budget-S and AA-HalfGain-S reach 30.8 and 27.4 mm against 72.2 mm for PID-Budget-S ( and mm; better in all 30 pairs in each case); the commanded-input designs stay far above the actuator-aware ones (A1 178.8 mm, RO-HalfGain 227.1 and 215.8 mm in S6 and S5, worse than AA-Budget or AA-HalfGain in every pair), and the ablation ordering is unchanged. With true rotor lags of 75–120 ms ( , seeds 92001–92003, 36 plant-seed pairs), the failure and fluctuation-threshold counts coincide with MATLAB: only PID-Budget and AA-HalfGain fail, at 120 ms. The actuator-aware designs lose 0.9–1.4 mm in S6 because they follow the estimate, whose position error in AA-Budget runs has an RMS of 3.7 mm; only the filtered rates show a material lag (see (ii)). The lockstep loop is not bit-reproducible (three AA-Budget runs of one seed: 20.1–21.8 mm), and PX4 occasionally skipped the output of a step: in 41 runs of the first campaign (one or two steps each) and in 101 of the 390 runs made for the redesigned controllers (at most nine steps
TABLE XII
MATLAB SIMULATION AND PX4 SITL (S6, WINDOW 10–40 s; S5, 5–45 s). POSITION RMSE IN MM, MEAN±SD OVER THE SAME PAIRED SEEDS (S6: 91001–91030; S5 AND ABLATIONS: 91001–91010). RO-HALFGAIN AND A1-COMMANDED: DESIGNS WITH ; PID-BUDGET-S: REDESIGN UNDER THE RESPONSE REQUIREMENT; PID-BUDGET: SET-POINT WEIGHTS OF SECTION IV-F, RUNS OF THE REDESIGNED-CONTROLLER CAMPAIGN. NO FAILURES IN EITHER SIMULATION.
| Case | Design | MATLAB | PX4 SITL |
|---|---|---|---|
| S6 | PID-Budget | ||
| AA-Budget | |||
| RO-HalfGain | |||
| AA-HalfGain | |||
| S6 strict | PID-Budget-S | ||
| AA-Budget-S | |||
| AA-HalfGain-S | |||
| S5 | PID-Budget | ||
| AA-Budget | |||
| RO-HalfGain | |||
| AA-HalfGain | |||
| S6 ablation | A1-Commanded | ||
| A2-Unaligned | |||
| A3-NoIncrement |
per run; Table XIII). For these runs the rule, declared before the sensitivity analysis, was to rerun a comparison group only if removing its pairs with skipped steps changed a paired conclusion. This did not occur (e.g., AA-Budget-E minus PID-E in S6: mm over the 23 pairs without skipped steps versus mm over all 30; AA-Budget-S minus PID-Budget-S: mm over 21 pairs; AA-Budget-E minus PID-Budget in S5: mm over the three pairs without skipped steps versus mm over all ten), so no run was repeated. Part of the hover runs and nine S6 runs of PID-Budget-S overlapped with a parallel computation on the host, which increased the skipped steps; no S6 or S5 run of the -E designs did.
(ii) Activity. The white-noise ceilings do not describe the estimator-fed loop. Logged inside PX4 before output quantization (ten paired S6 seeds), the rotor-command increments are 0.084, 0.183 and 0.153 rad/s for PID-Budget, AA-Budget and AA-HalfGain (MATLAB, same seeds: 9.91, 7.45 and 7.57 rad/s), so the activity ordering reverses. When the estimator is bypassed and the same code reads the measurement
TABLE XIII
SKIPPED LOCKSTEP STEPS IN THE SITL RUNS OF THE REDESIGNED CONTROLLERS. ALL RUNS ARE REPORTED; RUNS: TOTAL RUNS OF THE GROUP, SKIP: RUNS WITH AT LEAST ONE SKIPPED STEP, STEPS: TOTAL SKIPPED STEPS (MAXIMUM PER RUN), PAR.: RUNS OVERLAPPING A PARALLEL COMPUTATION ON THE HOST.
| Group | Runs | Skip | Steps (max) | Par. |
|---|---|---|---|---|
| Hover 60 s, -E designs (refit) | 30 | 7 | 9 (3) | 24 |
| S6, -E designs | 90 | 10 | 11 (2) | 0 |
| S5, -E designs | 30 | 2 | 2 (1) | 0 |
| Hover 300 s, -E designs | 30 | 11 | 16 (3) | 0 |
| Hover 300 s, primary and strict | 60 | 35 | 68 (9) | 3 |
| S6, PID-Budget-S | 30 | 9 | 22 (6) | 9 |
| Hover 60 s, PID-Budget-S | 10 | 1 | 1 (1) | 2 |
| S6, A1, ratio ≥ 1.5 (sensitivity) | 10 | 5 | 30 (9) | 5 |
| S6, A1, ratio ≥ 1 | 10 | 1 | 1 (1) | n.r. |
| S6, RO-HalfGain | 30 | 3 | 3 (1) | n.r. |
| S5, RO-HalfGain | 10 | 1 | 1 (1) | n.r. |
| S6, PID-Budget (set-point rule) | 30 | 8 | 9 (2) | n.r. |
| S5, PID-Budget (set-point rule) | 10 | 6 | 6 (1) | n.r. |
| S6 bypass, PID-Budget (set-point rule) | 10 | 2 | 2 (1) | n.r. |
| Total | 390 | 101 | 181 |
n.r.: not recorded; only light post-processing ran on the host during these runs. In the independent rerun (Section V-J), 76 of these 390 runs had skipped steps (1088 steps in total, 999 of them in a single 300-s hover run of AA-HalfGain-S); no rerun result enters this table or the noise models, and overlap with host jobs was not recorded for the rerun.
model of Table II at 1 kHz with a 5-ms delay, the increments return to 9.91, 7.46 and 7.57 rad/s and the hover increments of the five designs of Table VII whose gains are unchanged agree with it within 0.3%; the reversal is therefore caused by the estimator, not by code generation, lockstep timing or quantization. For the model of Section IV-G, the controller logs the twelve signals it uses at every step and the plant state gives their errors, in 60 noise-only hover runs (six designs, including an earlier strict PID whose logs serve only as fitting data; seeds 96001–96010, window 20–60 s). The EKF2 errors are concentrated below about 1 Hz, whereas the rate errors carry the gyroscope noise through the 40-Hz PX4 filter. Only the rates show a material lag (6 ms, which reduces their S6 error RMS to about 0.3 of the zero-lag value), so they keep a 6-ms buffer and the other signals none. For each channel class a vector autoregressive model of the error vector, fitted on seeds 96001–96005 (orders 13–15 except one first-order yaw model, by the Bayesian information criterion among stationary fits; one model per design, because the attitude-error increments differ up to fivefold between designs), gives (31). The error statistics therefore depend on the closed loop; at design time the model pooled over the designs is used (validated below). On the held-out seeds the standard deviations of its error increments agree within 2% for the rate errors and within 10% for the other outputs except one position channel (20%), whereas the variance of the slowly drifting attitude errors is not reproduced. With the 6-ms rate delay the input-sensitivity peak becomes 2.04, 1.92 and 2.02 for PID-Budget, AA-Budget and AA-HalfGain (1.97–1.98 without), mainly in the attitude class.
Validation at three levels. Because 60-s logs are short compared with the slow EKF2 errors, the model was validated on 300-s noise-only hover runs (window 20–300 s) of nine designs, the three primary, the three strict and the three -E designs of (iii), with seeds 97001–97005 for fitting and
TABLE XIV
NOISE-MODEL VALIDATION IN 300-S NOISE-ONLY HOVER BEHIND EKF2 (WINDOW 20–300 s, NINE DESIGNS). RATIO OF PREDICTED TO MEASURED STANDARD DEVIATION, MINIMUM–MAXIMUM OVER THE DESIGNS; FIT SEEDS 97001–97005, HELD-OUT (H.O.) SEEDS 97006–97010. (A) PER-DESIGN MODEL; (B) MODEL POOLED OVER THE NINE DESIGNS; (C) DESIGN-STAGE MODEL OF THE THREE -E DESIGNS, HELD-OUT SEEDS (OUT OF SAMPLE). : INNER INCREMENT (ROLL/PITCH: CASCADE OUTPUT); : CONTROL; : TRACKING ERROR; J: ROTOR-COMMAND INCREMENT.
| Quantity | (a) per design | (b) pooled | (c) design stage | ||
|---|---|---|---|---|---|
| fit | h.o. | fit | h.o. | h.o. | |
| 0.98–1.00 | 0.98–1.00 | 0.96–1.01 | 0.95–1.01 | 0.97–1.01 | |
| 1.00 | 1.00–1.01 | 0.99–1.00 | 1.00–1.01 | 1.01–1.02 | |
| 0.98–1.06 | 0.96–1.06 | 0.83–1.07 | 0.81–1.07 | 0.83–1.07 | |
| J | 0.98–1.03 | 0.97–1.03 | 0.87–1.04 | 0.86–1.04 | 0.93–1.04 |
| 0.81–0.97 | 0.81–0.97 | 0.81–0.97 | 0.81–0.97 | 0.87–0.93 | |
| 0.94–1.04 | 0.94–1.02 | 0.93–1.04 | 0.93–1.02 | 0.93–1.01 | |
| 0.83–1.02 | 0.84–1.02 | 0.83–1.02 | 0.84–1.02 | 0.91–1.02 | |
| 0.95–1.22 | 0.93–1.21 | 0.94–1.25 | 0.95–1.23 | 0.94–1.20 | |
| 0.91–1.08 | 0.87–1.07 | 0.89–1.08 | 0.89–1.07 | 0.95–1.07 | |
| 0.97–1.01 | 0.89–1.06 | 0.94–1.03 | 0.91–1.05 | 1.58–1.61 | |
97006–97010 held out: (a) one model per design fitted on its own 300-s logs; (b) one model pooled over the nine designs; (c) for the -E designs, the pooled model of the design stage, fitted on the 60-s logs above before any -E run (refitted with the 6-ms delay on the yaw rate as well, Appendix B). Table XIV lists the predicted-to-measured ratios of the standard deviations. The model predicts the roll/pitch and yaw increments within 5% on held-out and out-of-sample runs, and the total rotor-command increment within 14%; the control standard deviation is underpredicted by up to 19% and the tracking standard deviation is matched within about 25% except the out-of-sample yaw tracking error (about 60%, see below), so the variance objective is an approximate design criterion. The pooled model underpredicts the altitude increment of the three PID designs by 17–19% and their J by up to 14%, because the altitude estimation error depends on the controller; the per-design models stay within 6%. The out-of-sample yaw tracking error is overpredicted by about 60% at level (c) but matched within 5% at level (b); its low-frequency spectrum cannot be identified from the 40-s window of the design-stage logs. The underprediction of is non-conservative but does not affect feasibility, since the measured control standard deviations of the -E designs stay 10–20 times below the local ceilings . On the same held-out runs, the white-noise model of the MATLAB designs overpredicts the roll/pitch inner increments by factors of 19 to 217.
(iii) Redesign for the estimator-fed loop. With the 6-ms rate lag, the input-sensitivity peaks of PID-Budget and AA-HalfGain are 2.04 and 2.02 (attitude class), above the specification, whereas AA-Budget stays at 1.92; AA-Budget and AA-HalfGain, however, exceed the estimator-aware cascade ceiling by factors of 5.5 and 3.6 and the yaw ceiling by factors of 15.7 and 13.9. For a like-for-like comparison all three were redesigned by the same procedure. PID-E, AA-Budget-E and AA-HalfGain-E were therefore designed by the procedure of Section IV-G with the frozen ceilings and ; all three meet in every class with the 6-ms lag, the response requirement, the local ceilings and,
TABLE XV
ESTIMATOR-AWARE DESIGNS: SENSITIVITY AND NOISE-ONLY HOVER (EKF2 INPUT, TEN 60-S RUNS, SEEDS 96001–96010). PER CLASS WITH THE 6-MS RATE LAG (DESIGN TARGET 1.98); CEILINGS , ; PREDICTIONS WITH THE DESIGN-STAGE POOLED MODEL (OUT OF SAMPLE); AND IN , J IN RAD/S. PID-BUDGET IS THE NOMINAL DESIGN, NOT REDESIGNED.
| Design | cas. | J | |||
|---|---|---|---|---|---|
| pred/meas. | pred/meas. | meas. | pred/meas. | ||
| PID-Budget | 1.94/1.81/2.04/1.99 | 0.0065/0.0066 | 4.75/4.74 | 5.0 | -/0.0259 |
| PID-E | 1.98/1.81/1.98/1.98 | 0.0064/0.0067 | 4.22/4.21 | 4.8 | 0.0236/0.0254 |
| AA-Budget-E | 1.98/1.46/1.96/1.97 | 0.0059/0.0059 | 4.31/4.24 | 7.0 | 0.0302/0.0290 |
| AA-HalfGain-E | 1.98/1.58/1.81/1.97 | 0.0064/0.0064 | 3.99/3.93 | 7.4 | 0.0317/0.0305 |
in the design-stage prediction, both estimator-aware ceilings (gains in Table XVII; the altitude classes of PID-Budget and AA-Budget already met them and were kept). After their hover logs, the refitted pooled model left every constraint satisfied (predicted-to-measured roll/pitch cascade increment 0.964, 0.998 and 1.008, yaw 0.998, 1.008 and 1.008), so the gains were frozen after the first design. The design-stage predictions of Table XV are therefore out of sample: the roll/pitch and yaw increments are matched within 4% and 2%, whereas J is underpredicted by 7% for PID-E and overpredicted by 4% for the AA designs, mainly through the altitude class. In S6 (Table XVI), AA-Budget-E reduces the RMSE from 59.1 mm (PID-E) to 44.0 mm, better in all 30 pairs, and its rotor-command increment is lower than that of PID-E and PID-Budget in all 30 S6 and 10 S5 pairs, both before and after output quantization; the mean reductions relative to PID-E are 45% and 15% in S6 and 51% and 30% in S5. AA-HalfGain-E, whose larger predicted tracking variance was already apparent at design time (predicted horizontal of 183 mm versus 83 and 108 mm for AA-Budget-E and PID-E), is better on the lemniscate but worse on the set-point scenario (84.7 mm, worse than PID-E in all 30 pairs), with a lower increment than both PID designs in all pairs. In S5 both AA designs stay far below the PID designs (49.5 and 90.6 versus 335.8 and 278.4 mm). In S5, PID-E is worse than PID-Budget by mm (all ten pairs), whereas it is better in S6 ( mm, all 30 pairs): for the selected PID gains its set-point weights stay of order because the overshoot limit is active (Section IV-F). The pooled measured hover cascade increment of PID-E is 0.00666, 2.3% above the frozen ceiling (full precision 0.0065137; 1.5% in the independent rerun, Section V-J), within the 4–5% validation error; the mean of its per-seed maximum-axis increments is (95% CI, ten seeds). The unchanged PID-Budget, which defines the ceiling through its prediction, measures 0.00660 (1.3% above; per-seed mean ), and AA-Budget-E and AA-HalfGain-E stay 8.7 and 2.0% below it. In noise-only hover, J of AA-Budget-E and AA-HalfGain-E is 12 and 18% above that of PID-Budget (0.0290 and 0.0305 versus 0.0259 rad/s; 15 and 20% in the rerun), because the altitude class has no ceiling ( and versus ); PID-E is 2% below it.
J. Numerical verification
For the designs of the first campaign (primary, ablation, earlier strict, budget-curve, stress and mismatch sets), a fresh rerun from the saved full-precision gains reproduces all 1830 nonlinear realizations with zero maximum absolute difference in finite raw metrics and identical failure classifications. An independent augmented-state increment expression agrees with the direct Lyapunov formula for all four nominal candidates and channel classes (maximum relative difference 2.08e-14); halving the RK4 plant substep changes nominal RMSE by at most 9.63e-08 mm; and a shared-function Simulink replication of all nominal candidates on S6 gives a maximum state discrepancy of 0. The redesigned controllers (A1-Commanded, RO-HalfGain, PID-Budget-S, the PID points of Fig. 3, the -E designs and the PID set-point weights) were not part of that rerun; their results come from single runs of the reported scripts with the same simulation code, and they are covered by the independent rerun below. The hover measurements in Table VI use ten paired 60-s noise-only trials per design (seeds 96001–96010, window 20–60 s, no wind, bias or external disturbance, no rotor clipping).
Independent rerun. All fixed protocols were rerun from a fresh copy of the code with the frozen full-precision gains, without re-optimization or noise-model refitting. In MATLAB, the 1830 primary realizations and the 1480 supplemental simulation calls of the redesigned controllers reproduce all metrics within a relative difference of , with identical failure classifications. All 1288 planned SITL runs were executed (30 of them belong to an unused second-iteration group and are not analysed), and the divergence classification of every run with an original counterpart is unchanged (six divergences, all in the mismatch set at a true rotor lag of 120 ms, as before). Because the lockstep loop is not deterministic, the SITL numbers differ slightly: the mean RMSEs of Tables XII and XVI change by at most 1.14 mm (PID-Budget, S5: 278.44 and 279.58 mm), every count of better pairs is unchanged, AA-Budget-E improves on PID-E by mm in S6 (original campaign mm), and the S6 reductions of J and relative to PID-E are 44.6 and 14.5% (original 45 and 15%). The tables report the original campaign, whose run plans were fixed beforehand; the rerun serves only as a reproducibility check.
VI. DISCUSSION AND SCOPE
The evidence supports actuator-aware observer inputs as a nominal design choice for the tested cascade rather than a universally necessary architecture. Budget and half-gain tuning are complementary variants, not a ranking: in MATLAB the half-gain variant is better at set-point and on the lemniscate, whereas on the estimator stack only AA-Budget-E beats PID in both scenarios. (i) Model and assumptions: the covariances are exact only for the implemented linear sampled model, and the plant relies on assumed sensor, rotor and wind specifications, Gaussian noise, Euler-angle kinematics without yaw-angle wrapping (unnecessary for the bounded yaw references used) and componentwise allocation clipping, without ground contact. Consequently, the stationary cascade ceiling closes
TABLE XVI
ESTIMATOR-AWARE DESIGNS IN PX4 SITL: TRACKING AND ROTOR-COMMAND INCREMENT. S6: 30 PAIRED TRIALS; S5: TEN. RMSE MEAN±SD; PAIRED CHANGE WITH 95% CI HALF-WIDTH AND NUMBER OF PAIRS IN WHICH THE DESIGN IS BETTER; J: ROTOR-COMMAND INCREMENT LOGGED BEFORE THE 1/1000 OUTPUT QUANTIZER; : COMPUTED FROM THE QUANTIZED ACTUATOR OUTPUTS RETURNED BY PX4. NO FAILURES. PID-BUDGET: SET-POINT WEIGHTS OF SECTION IV-F, RUNS MADE WITH THE SAME BUILD AND ACTIVITY LOGGING AS THE -E RUNS ON THE SAME SEEDS (ALSO USED IN TABLE XII).
| Design | S6 | S5 | ||||||
|---|---|---|---|---|---|---|---|---|
| RMSE [mm] | vs PID-B. [mm] | vs PID-E [mm] | J [rad/s] | [rad/s] | RMSE [mm] | J [rad/s] | [rad/s] | |
| PID-Budget | 65.0±6.7 | - | - | 0.084 | 0.224 | 278.4±8.3 | 0.222 | 0.273 |
| PID-E | 59.1±6.3 | -5.9 ± 1.0 (30) | - | 0.089 | 0.231 | 335.8±6.6 | 0.228 | 0.294 |
| AA-Budget-E | 44.0±4.0 | -21.0 ± 1.3 (30) | -15.0 ± 1.1 (30) | 0.049 | 0.196 | 49.5±5.6 | 0.111 | 0.205 |
| AA-HalfGain-E | 84.7±8.2 | +19.7 ± 1.0 (0) | +25.6 ± 1.1 (0) | 0.047 | 0.192 | 90.6±11.9 | 0.097 | 0.194 |
the modeled position-to-attitude noise path at nominal hover but does not bound nonlinear rotor-command activity under mismatch, varying noise or clipping, and command increments remain surrogates for motor power, heating or lifetime. With the 6-ms filtered-rate lag of the PX4 stack, the sampled input-sensitivity peak of the nominal PID-Budget and AA-HalfGain rises to 2.04 and 2.02, slightly above the reporting limit; the -E designs include this lag in the screen and meet 1.98 in every class. The identified noise model depends on the controller as well; for the -E designs the redesign–refit check confirmed all constraints after the first design, but the pooled model is less accurate for the altitude class of the PID designs and for the control and tracking standard deviations, including an out-of-sample yaw tracking error about 60% too large (Table XIV), so the variance objective is approximate. The lemniscate error of the PID designs depends on the set-point weight, which the common overshoot limit keeps small for PID-Budget-S and PID-E. With commanded inputs, the response and sensitivity requirements are met, within the stated finite search, only at the lowest observer/controller ratios, so the magnitude of the commanded-input ablation (9.2-fold for , 12.8-fold on the original grid, 18.9-fold for ) depends on the admissible ratio range. (ii) Finite checks: frequency, ratio and uncertainty grids and finite paired samples with unadjusted per-comparison intervals do not certify continuous-frequency or nonlinear stability or global design optimality, and a rotor-fluctuation exceedance alone does not prove self-excited oscillation. (iii) Open items: robust redesign, rotor-cap and allocation-aware studies are reserved for a companion paper, and the shared-function Simulink replication checks implementation consistency only. The PX4 SITL check (Section V-I) runs the autopilot software and its estimator but uses the same plant model; HIL and flight validation remain future work. The estimator-coloured noise model is specific to the EKF2, sensor, rate-filter and delay configuration of this PX4 stack and must be re-identified before its predictions are reused with another estimator, sensor set, tuning or autopilot configuration, and the comparison behind the estimator constrains the roll/pitch-cascade and yaw increments but not the altitude class. A ceiling for that class would address the hover excess of the AA-E designs (12–20% in over the original and rerun campaigns); this is a next step, not a result of this paper.
VII. CONCLUSION
This paper showed that the input supplied to the extended-state observer is a design variable in sampled cascade LADRC of quadrotors. Delay-aligned actuator-model inputs for altitude and attitude and measured-attitude inputs for horizontal motion remove the nominal structural observer-input residual under matched lag and delay; with commanded inputs, feasible designs were found, within the stated finite search, only at the lowest observer/controller ratios, with 9.2 times the RMSE of AA-Budget. A full-cascade covariance model predicts the noise-induced inner-loop increment in noise-only hover with white measurement noise within 0.3%, which turns the outer-to-inner noise path into an explicit tuning constraint. In paired set-point and lemniscate trials, AA-Budget and AA-HalfGain reach 19.2/16.9 mm and 22.7/20.4 mm versus 65.5 and 276.5 mm for PID-Budget, and 29.9 and 26.4 mm versus 72.3 mm under a common strict cascade ceiling, at which the PID uses roughly double their rotor-command increment. The nominal advantage does not extend to large rotor-lag mismatch.
PX4 software-in-the-loop runs reproduce these results within 2 mm in two independent campaigns. Behind EKF2, a shaping-filter model of the estimation errors predicts the roll/pitch and yaw increments within 5% and the total rotor-command increment within 14%, but the tracking variance only approximately. Redesigned for this stack under the same specification, AA-Budget-E reduces the set-point and lemniscate RMSEs from 59.1 to 44.0 mm and from 335.8 to 49.5 mm relative to PID-E, with a lower rotor-command increment in every paired tracking run (S6 mean: 45% lower before and 15% after output quantization), whereas AA-HalfGain-E is worse on the set-point scenario. The evidence is limited to simulation and SITL with one plant model and one estimator configuration; robust redesign over an uncertainty set, a ceiling for the altitude class and HIL or flight validation remain future work.
APPENDIX A
SCENARIOS AND REPRODUCIBILITY
All trials start at zero position, Euler angles and rates, with rotors at hover; noise and gyro bias are active from startup, and mean wind and turbulence start at 5 s. In S6 (40 s, window 10–40 s) the reference is the step m/rad at , so the initial transient is excluded from
RMSE but can affect the subsequent trajectory. In S5 (45 s, window 5–45 s) the reference climbs smoothly to 2 m in 5 s and then follows a horizontal lemniscate with 1-m amplitude and 20-s period, with . Both scenarios add the torque disturbance Nm from 15 s. MEX-accelerated runs are checked against full MATLAB trajectories before use, and all figures and table entries are generated from the saved results.
Seeds. Nominal, ablation, strict and budget-curve trials: 91001–91030 (SITL S5 and ablations: 91001–91010); mismatch: 92001–92010; noise and latency stress: 93001–93010; 60-s hover: 96001–96010 (fit 96001–96005); 300-s hover validation: 97001–97010 (fit 97001–97005).
PX4 configuration. PX4 v1.16.1 SITL in lockstep; IMU integration and gyroscope rate 1 kHz (IMU_INTEG_RATE, IMU_GYRO_RATEMAX); EKF2 fuses the IMU and external vision for position, velocity and yaw (EKF2_EV_CTRL = 15, EKF2_HGT_REF = 3, EKF2_EV_DELAY = 5 ms, EKF2_EVP_NOISE, EKF2_EVV_NOISE, EKF2_EVA_NOISE = 0.01 m, 0.02 m/s, 0.05 rad); GPS, barometer, magnetometer and range sensor are not fused; all other parameters, including the 40-Hz gyroscope filter, are PX4 defaults. Delays: 5-ms measurement and external-vision latency; models of the -E designs use a 6-ms delay on the three body rates and none on the other signals.
Gains, models and scripts. Table XVII lists the gains of the strict and estimator-aware designs; the budget-curve gains and all full-precision gains are stored with the code, together with the coefficients, innovation covariances and orders of every noise model, the frozen ceilings, the fixed SITL run plans, and the scripts that generate each table and figure from the saved runs. The code is organized in five folders (simulation and design, Simulink model, PX4 SITL, estimator-noise modelling, and analysis); a manifest lists, for every reported result, the generating script, the result file, the design source and the SHA-256 checksum of the file, and a clean-regeneration test rebuilds the data of Tables XII, XV and XVI and of Fig. 3 from the stored result files in an empty folder (all differences zero). A step-by-step audit and re-run procedure, from static checks to the full MATLAB and SITL recomputation, is included with the code. Code, controller gains, random seeds, and per-seed results are publicly available at: https://github.com/Quang61123/actuator-aware-cascade-adrc.
APPENDIX B
SEARCH AND FEASIBILITY-REPAIR DETAILS
Sensitivity grid. During the design search, is evaluated on 600 logarithmically spaced positive frequencies from rad/s to , plus dc, followed by local peak refinement; final candidates are re-evaluated on 4000 positive frequencies plus dc with refined peak searches. The tuning limit 1.98 provides numerical headroom for the final audit at 2. Grid peaks no greater than are omitted from local refinement to avoid round-off extrema on the unity plateau; they remain included in the grid maximum.
Bandwidth search. For each observer-to-controller ratio on a prescribed grid, a bandwidth scan identifies
TABLE XVII
GAINS OF THE STRICT AND ESTIMATOR-AWARE DESIGNS. (A) PID ; (B) LADRC () IN RAD/S; NOTATION AS IN TABLE IV. PID-E KEEPS THE ALTITUDE GAINS OF PID-BUDGET, AND AA-BUDGET-E AND AA-HALFGAIN-E KEEP THE ALTITUDE BANDWIDTHS OF AA-BUDGET AND AA-HALFGAIN.
| (a) PID | ||||||
|---|---|---|---|---|---|---|
| Design | Class | b | ||||
| PID-Budget-S | 5.151 | 4.083 | 3.032 | 795.5 | 0.300 | |
| z | 19.462 | 35.684 | 6.876 | 19.985 | 0.0017 | |
| 71.423 | 58.449 | 9.485 | 301.57 | 0.789 | ||
| 32.215 | 73.392 | 9.064 | 33.064 | 0.0018 | ||
| PID-E | 5.232 | 4.885 | 2.912 | 15054 | 0.0014 | |
| 118.261 | 112.004 | 16.746 | 671.71 | 0.983 | ||
| 32.216 | 74.970 | 8.887 | 33.976 | 0.0012 | ||
| (b) LADRC | ||||
|---|---|---|---|---|
| Design | ||||
| AA-Budget-S | (1.646,30.811) | (3.029,34.773) | (8.340,156.108) | (4.025,59.598) |
|---|---|---|---|---|
| AA-HalfGain-S | (1.723,39.167) | (3.053,45.203) | (8.726,146.738) | (4.085,76.450) |
| AA-Budget-E | (1.372,31.188) | (3.786,43.466) | (6.808,54.612) | (5.191,9.454) |
| AA-HalfGain-E | (1.137,9.786) | (3.816,56.503) | (5.685,89.187) | (3.125,18.245) |
feasible intervals of (29), whose boundaries are then refined. The feasible design with the smallest predicted tracking variance is retained and rechecked with the full-resolution overshoot calculation and the 4000-point sensitivity search. The inner and altitude searches use an overshoot screen of 9.95% (horizontal reselection: 10%), and all final designs are audited against 10%.
Cascade thresholds. A 1% feasibility margin is applied below the selected cascade threshold in every call to the horizontal reselection routine, including strict and budget-curve PID candidates.
Strict designs and repair. The inner LADRC bandwidths are initially scaled by 0.8, and the PID inner-loop bandwidth by 0.9 with its controller shape preserved. If necessary, a full-resolution feasibility-repair step further reduces controller or observer bandwidths, or the PID set-point weight, until the constraints are satisfied. The horizontal gains are then redesigned with the same local activity limits and the selected cascade constraint. Because the procedure combines finite grid searches, boundary refinement and feasibility repair, the reported parameters are the best feasible designs found, not global optima.
Redesigns under the response requirement. PID-Budget-S was redesigned by multistart sequential quadratic programming (SQP; 20 starts for each of and and 20 for a joint search under the strict cascade ceiling) with all constraints of (29); this search additionally required a spectral radius of at most 0.9999, tighter than the specification . The PID budget-curve points and 0.75 used the same multistart search followed, for infeasible results, by a general repair step that reduces the controller bandwidth by factors of 0.985 and then 0.9 and lowers the set-point weight when the overshoot is exceeded; the levels are processed in increasing , and the feasible design of the smaller is included as a start and as a candidate at the larger , where it remains feasible because only the local ceilings change. Because three constraints are active at once, these searches use an overshoot target of 9.99%, while the final audit uses 10%.
A1-Commanded and RO-HalfGain were searched for every class on 24 ratios (the 20 original ratios plus 1.0–1.36) with 60 controller bandwidths per ratio. For the -E designs, PID-E used multistart SQP (20 starts for and for the joint search), with the set-point weight then lowered in 18 steps of 0.1% to move an overshoot of inside the limit ( affects only the reference response); AA-Budget-E and AA-HalfGain-E used a grid for and a grid for , each feasible attitude point followed by the horizontal search.
Noise-model fitting. The estimator-aware models of Section V-I are vector autoregressive models of the class error vectors, fitted by least squares for each channel class and design on the hover seeds 96001–96005 and written in the innovations form (31); the order (at most 15) minimizes the Bayesian information criterion among the stationary fits. A subspace (n4sid) fit was tried first and discarded, because on the training data it missed the increment variances by factors of 30 to 9000. The stationarity requirement was added when the first prediction for one design (a nonstationary yaw fit of the earlier strict PID design) was unbounded, before any comparison with the SITL hover data was possible; it changed only that yaw model, and no other choice, including the signal delays, was changed after the predictions were compared with the 60-s SITL hover runs. Propagating the measured cross-spectral densities instead of the fitted filters changes the predicted increments by less than 2%. A pooled model is fitted by least squares on the concatenated training segments of all designs in the pool, each segment demeaned and every output scaled by its pooled standard deviation; the -E designs were selected with the model pooled over the six designs of the 60-s logs. For the three-level validation of Table XIV the same procedure was applied to the 300-s logs, per design (level a) and pooled over the nine designs (level b). The design-stage model had no delay on the yaw-rate error; for level (c) it was refitted on the same 60-s logs with the 6-ms convention on all body rates, which changes the yaw predictions by less than 0.5%, and all constraints of the -E designs remain satisfied with it.
REFERENCES
[1] R. Mahony, V. Kumar, and P. Corke, "Multirotor aerial vehicles: Modeling, estimation, and control of quadrotor," IEEE Robotics & Automation Magazine, vol. 19, no. 3, pp. 20–32, 2012, doi: 10.1109/MRA.2012.2206474.
[2] J. Han, "From PID to active disturbance rejection control," IEEE Transactions on Industrial Electronics, vol. 56, no. 3, pp. 900–906, 2009, doi: 10.1109/TIE.2008.2011621.
[3] Z. Gao, "Scaling and bandwidth-parameterization based controller tuning," in Proc. American Control Conference (ACC), vol. 6, 2003, pp. 4989–4996, doi: 10.1109/ACC.2003.1242516.
[4] R. Wang and J. Shen, "Disturbance observer and adaptive control for disturbance rejection of quadrotor: A survey," Actuators, vol. 13, no. 6, p. 217, 2024, doi: 10.3390/act13060217.
[5] M. Ramírez-Neria, A. Luviano-Juárez, J. González-Sierra, R. Ramírez-Juárez, J. Aguerrebere, and E. G. Hernandez-Martinez, "Active disturbance rejection control for the trajectory tracking of a quadrotor," Actuators, vol. 13, no. 9, p. 340, 2024, doi: 10.3390/act13090340.
[6] C. He, H. Sun, Q. Wu, Y. Su, and N. Sun, "GPI observer-based active disturbance rejection control for a morphing quadrotor," Intelligence & Robotics, vol. 3, no. 3, pp. 274–287, 2023, doi: 10.20517/ir.2023.18.
[7] G. Xu, S. Luo, Y. Huang, and X. Deng, "Extended state observer based robust nonlinear PID attitude tracking control of quadrotor with lumped disturbance," Processes, vol. 13, no. 5, p. 1470, 2025, doi: 10.3390/pr13051470.
[8] Y. Zeng, G. Yang, and Z. Wang, "Active disturbance rejection geometric control of quadrotor UAV on SO(3)," Journal of the Franklin Institute, vol. 362, no. 10, p. 107744, 2025, doi: 10.1016/j.jfranklin.2025.107744.
[9] A. Miranda-Moya, H. Castañeda, and H. Wang, "Fixed-time extended observer-based adaptive sliding mode control for a quadrotor UAV under severe turbulent wind," Drones, vol. 7, no. 12, p. 700, 2023, doi: 10.3390/drones7120700.
[10] T. Huang, K. Liu, Y. Yang, C.-Y. Wen, and X. Huang, "Disturbance-observer-based fixed-time backstepping control for quadrotors with input saturation and actuator failure," Drones, vol. 9, no. 1, p. 67, 2025, doi: 10.3390/drones9010067.
[11] L. Xu, K. Qin, F. Tang, M. Shi, and B. Lin, "A novel attitude control strategy for a quadrotor drone with actuator dynamics based on a high-order sliding mode disturbance observer," Drones, vol. 8, no. 4, p. 131, 2024, doi: 10.3390/drones8040131.
[12] L. Xu, B. Tian, C. Wang, J. Lu, D. Wang, Z. Li, and Q. Zong, "Fixed-time disturbance observer-based MPC robust trajectory tracking control of quadrotor," arXiv preprint arXiv:2408.15019, 2024, doi: 10.48550/arXiv.2408.15019.
[13] M. Izadi and R. Faieghi, "High-gain disturbance observer for robust trajectory tracking of quadrotors," arXiv preprint arXiv:2305.19115, 2023, doi: 10.48550/arXiv.2305.19115.
[14] B.-n. Li, M. Chen, and S.-C. Qi, "Finite-time trajectory tracking control of quadrotor UAVs based on neural network disturbance observer and command filter," International Journal of Systems Science, vol. 56, no. 7, pp. 1474–1488, 2025, doi: 10.1080/00207721.2024.2427852.
[15] Q. Zheng, L. Q. Gao, and Z. Gao, "On stability analysis of active disturbance rejection control for nonlinear time-varying plants with unknown dynamics," in Proc. 46th IEEE Conf. Decision and Control (CDC), 2007, pp. 3501–3506, doi: 10.1109/CDC.2007.4434676.
[16] W. Zhou, S. Zhang, X. Hu, and F. Zong, "Rapid optimization of active disturbance rejection controller parameters for quadrotor UAVs using kriging surrogate modeling," Drones, vol. 8, no. 11, p. 658, 2024, doi: 10.3390/drones8110658.
[17] K. Li, G. Wang, and Y. Bai, "A second-order LADRC-based control strategy for quadrotor UAVs using a modified crayfish optimization algorithm and fuzzy logic," Electronics, vol. 14, no. 15, p. 3124, 2025, doi: 10.3390/electronics14153124.
[18] Z. Li, Q. Wang, and H. Yan, "Event-triggered fault-tolerant ADRC for variable-load quadrotor with prescribed performance," Applied Sciences, vol. 15, no. 13, p. 7021, 2025, doi: 10.3390/app15137021.
[19] R. Cai, L. Zhang, W. Qin, and J. Yan, "Intelligent control for quadrotors based on a novel method: TD3-ADRC," Drones, vol. 10, no. 2, p. 110, 2026, doi: 10.3390/drones10020110.
[20] A. Vaisuo, G. Immordino, L. Onofri, G. Coppotelli, and M. Righi, "Methods for multi-objective optimization PID controller for quadrotor UAVs," arXiv preprint arXiv:2509.17423, 2025, doi: 10.48550/arXiv.2509.17423.
[21] L. Liu, L. Yang, and J. Zhang, "A bi-bandwidth extended state observer for system with measurement noise," in Proc. IEEE 16th Int. Conf. Control and Automation (ICCA), 2020, pp. 1014–1019, doi: 10.1109/ICCA51439.2020.9264460.
[22] B. Cui, G. Zhao, Y. Xia, P. Wang, and Y. Zhang, "A variable-bandwidth extended state observer for nonlinear systems with measurement noise," IEEE Transactions on Industrial Electronics, vol. 72, no. 2, pp. 1946–1957, 2025, doi: 10.1109/TIE.2024.3419254.
[23] G. Herbst and A.-J. Hempel, "Half-gain observer tuning for noise reduction in discrete-time ADRC," Control Engineering Practice, vol. 164, p. 106501, 2025, doi: 10.1016/j.conengprc.2025.106501.
[24] W. Wei, X. You, M. Zuo, and Z. Gao, "A linear extended state observer with scalable bandwidth-based advanced internal mode attitude control for a quadrotor," IEEE Transactions on Industrial Electronics, vol. 73, no. 1, pp. 1174–1184, 2026, doi: 10.1109/TIE.2025.3581276.
[25] M. Zhang, L. Yang, Y. Hou, M. Ran, and S. Zhang, "Output tracking for nonlinear systems subject to unmodeled sluggish actuator dynamics via model-based extended state observer," ISA Transactions, vol. 125, pp. 198–211, 2022, doi: 10.1016/j.isatra.2021.06.028.
[26] P. Skupin, P. Nowak, and J. Czczech, "On the stability of active disturbance rejection control for first-order plus delay time processes," ISA Transactions, vol. 125, pp. 179–188, 2022, doi: 10.1016/j.isatra.2021.06.030.
[27] Y. Bai, J. Yao, and J. Hu, "A new state observer for active disturbance rejection control with measurement noise and output delay using the
PDE-backstepping predictor," ISA Transactions, vol. 142, pp. 562–572, 2023, doi: 10.1016/j.isatra.2023.07.013.
[28] J. Michalski, M. Mrotek, D. Pazderski, P. Kozierski, and M. Retinger, "Improving performance of ADRC control systems affected by measurement noise using kalman filter-tuned extended state observer," Electronics, vol. 13, no. 24, p. 4916, 2024, doi: 10.3390/electronics13244916.
[29] T. Luukkonen, “Modelling and control of quadcopter,” Aalto University, School of Science, Espoo, Finland, Independent research project in applied mathematics (Mat-2.4108), Aug. 2011. [Online]. Available: https://sal.aalto.fi/publications/pdf-files/eluu11_public.pdf
[30] C. Powers, D. Mellinger, and V. Kumar, “Quadrotor kinematics and dynamics,” in Handbook of Unmanned Aerial Vehicles. Springer, 2015, pp. 307–328, doi: 10.1007/978-90-481-9707-1_71.
[31] E. Gallo and A. Barrientos, “Customizable stochastic high-fidelity model of the sensors and camera onboard a fixed wing autonomous aircraft,” Sensors, vol. 22, no. 15, p. 5518, 2022, doi: 10.3390/s22155518.
[32] Y. Zhou, Z. Wu, and C. Yang, “Gust alleviation and wind tunnel test by using combined feedforward control and feedback control,” Aerospace, vol. 9, no. 4, p. 225, 2022, doi: 10.3390/aerospace9040225.