FFAI: Flow Matching with Feedback Training and Adaptive Initialization for CT Reconstruction

Jigang Duan, Heran Wang, Genwei Ma, Xing Zhao

Jigang Duan†, Heran Wang†, Genwei Ma, and Xing Zhao*

Abstract—Although low-dose, sparse-view, and limited-angle CT involve distinct degradation mechanisms, all three pose reconstruction challenges due to limited measurement information and can therefore be addressed within a unified framework. In iterative image restoration with flow matching, prediction errors may cause inference states to deviate from the prescribed training path, while a fixed initialization may be unsuitable for inputs with varying degradation severity. We propose a unified conditional flow matching method that conditions on the initial reconstruction and combines feedback-aware training with degradation-adaptive initialization. During training, a teacher network simulates inference updates to generate shifted states, from which a student network learns to recover high-quality reference images, improving its ability to handle prediction errors. During inference, the starting time is selected based on the noise level or extent of missing projection data, and the noise added to the initial state is adjusted accordingly to adapt the starting point to the input. Experiments on public benchmark datasets show that the proposed method achieves better quantitative results than the compared methods across all three reconstruction tasks, effectively suppressing noise and artifacts while preserving anatomical structures and details.

Index Terms—Computed tomography, conditional flow matching, degradation-adaptive initialization, feedback-aware training, image reconstruction.

I. INTRODUCTION

COMPUTED tomography (CT) provides cross-sectional images of internal anatomical structures and plays an important role in disease screening and clinical diagnosis. Maintaining image quality while reducing radiation dose remains a central goal in medical CT [1]. Radiation dose is typically reduced by decreasing either the incident photon count per view or the number of projection views. The former yields low-dose CT, whereas the latter can be achieved by increasing the angular sampling interval or reducing the scan angular range, corresponding to sparse-view and limited-angle CT, respectively [2]. Despite their distinct degradation mechanisms, all three conditions provide limited measurement information, weakening the constraints that measured projections impose on the reconstructed image. We collectively refer to these conditions as degraded acquisition and investigate a unified reconstruction method.

References (42)