arXiv:2608.24025cs.CVAug 2026

Manuscript Offprint

arXiv:2608.24025

Low-Rank Velocity Fields as a Structural Prior for Unsupervised 4D Medical Image Interpolation

Haojin Li, Hengzhuo Wang, Chang Liu, Zhiheng Ma, Heng Li, Jiang Liu

Haojin Li 1^{1}, Hengzhuo Wang 2,3^{2,3}, Chang Liu 2^{2}, Zhiheng Ma 4^{4}, Heng Li 2,5^{2,5}, and Jiang Liu 1,5^{1,5}

1^{1} Department of Computer Science and Engineering, Southern University of Science and Technology, Shenzhen, China

2^{2} Faculty of Biomedical Engineering, Shenzhen University of Advanced Technology, Shenzhen, China

3^{3} School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China

4^{4} Faculty of Computation Microelectronics, Shenzhen University of Advanced Technology, Shenzhen, China

5^{5} Research Institute of Trustworthy Autonomous Systems, Southern University of Science and Technology, Shenzhen, China

Corresponding authors: liheng@suat-sz.edu.cn, liuj@sustech.edu.cn

Abstract. Endpoint-only unsupervised 4D medical image interpolation synthesizes intermediate volumes from sparsely sampled sequences with only the start and end volumes available for training; however, this weakly constrained setting often yields intermediates with unstable boundaries and non-physiological motion, limiting interpretability and downstream analysis. We propose low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppressing voxel-wise high-frequency artifacts. To capture global coordination and local non-rigid details, we model motion in a coarse-to-fine multi-scale scheme and compose scale-wise deformations at inference to synthesize volumes at arbitrary times. We further provide a theoretical analysis showing that, under Tucker parameterization, low-rank parameters control the smoothness energy of the velocity field, explaining why low-rank modeling promotes smoother motion. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance, remaining competitive with methods trained with intermediate-frame supervision, and producing intermediates with improved structural coherence and more stable anatomical contours.

Keywords: 4D Medical Imaging · 4D Image Interpolation · Low-Rank Velocity Fields · Motion Modeling

1 Introduction

4D medical imaging captures anatomical dynamics and supports functional assessment, therapy monitoring, and longitudinal disease tracking [22]. However,

Haojin Li, Hengzhuo Wang, Chang Liu et al.

practical acquisition constraints often lead to sparse and irregular temporal sampling, motivating 4D interpolation to synthesize intermediate volumes and increase temporal resolution for downstream analysis such as segmentation [17] and reconstruction [15]. Here, we study endpoint-only unsupervised 4D medical interpolation, where training provides only two endpoint volumes.

Prior volumetric interpolation methods are broadly motion-driven, warping endpoints via estimated deformations (or flows) [7, 21, 12], or synthesis-driven, directly generating intermediate volumes [23, 24], and are sometimes combined [11, 5]. For medical imaging, plausible intermediates must preserve anatomical continuity and topology while evolving smoothly [25]. Under endpoint-only supervision, fully voxel-wise, high-dimensional motion parameterizations can overfit locally inconsistent high-frequency motion, leading to boundary instability, local misalignment, and non-physiological warping that degrades interpretability and downstream usability.

Anatomical motion is strongly spatially correlated and partially compressible: coordinated global patterns dominate, while local non-rigid details remain residual variation [18, 9]. This motivates an anatomy-aligned, compact motion representation rather than increased voxel-level freedom; thus we adopt structured low-rank motion modeling to suppress spurious high-frequency motion and improve anatomical consistency and temporal coherence of synthesized intermediates.

Two challenges arise when introducing structured low-rank motion into endpoint-only unsupervised 4D interpolation: (1) how to impose a compact, low-dimensional motion parameterization that captures shared spatial coordination yet adapts to each sample under weak supervision; (2) how to model motion across scales, as coarse global trends and fine non-rigid details call for a multi-scale representation and refinement [19].

To tackle these challenges, we propose a framework for endpoint-only unsupervised 4D medical image interpolation that introduces low-rank velocity fields as a structural prior. The framework separates shared coordinated motion from sample-specific variation and organizes motion modeling in a multi-scale hierarchy for coarse-to-fine refinement, thereby guiding endpoint-only learning toward anatomically plausible dynamics. Our contributions are summarized as follows:

– We present low-rank velocity fields as a structural prior for endpoint-only unsupervised 4D medical interpolation, improving anatomical consistency and temporal coherence, with analysis showing that low-rank parameterization bounds smoothness energy and suppresses high-frequency motion artifacts.

– We introduce a Tucker-parameterized low-rank velocity representation with shared spatial bases and a compact, sample-dependent core to capture coordinated motion while retaining individual variation.

– We propose a multi-scale low-rank motion modeling strategy that allocates capacity across resolutions for coarse-to-fine refinement from global coordination to local non-rigid deformation.

– Experiments on ACDC and 4D-Lung show strong results, achieving the best structure-oriented scores with competitive reconstruction accuracy.

Figure

Fig. 1. Overview of the proposed framework. (a) Multi-scale endpoint features are projected into a structured low-rank velocity representation across resolutions via Tucker decomposition, aligning motion modeling with the coordinated and compact nature of anatomical dynamics. (b) Inference performs bi-directional continuous-time interpolation to produce structurally consistent intermediate volumes.

References (25)