Abstract—Video-based gait assessment often keeps only high-confidence pose observations, which can lower measurement error but change the movement assessed. We compared confidence selection with budget-matched random selection in a Parkinson-related cohort (n = 96) and an NF2-related replication cohort (n = 18). In the Parkinson-related cohort, confidence selection produced a small but consistent shift in the observed movement summary (+0.05 SD, 95% CI 0.03 to 0.07), while held-out Mini-BESTest error stayed flat (-0.04 points, -0.13 to 0.05); a policy preserving motion-group proportions reduced the shift, while NF2 showed no shift and its predictor did not beat a constant baseline. Because this shift mixes measurement error with selection shift, we decompose and simulate both on the cohort's window structure. Filtering lowers local error when error depends on confidence, but biases the endpoint once confidence tracks movement more than error. In the Parkinson-related data, confidence was only weakly tied to movement ( ρ=0.14\rho = 0.14). There, filtering is harmless if well-tracked windows are unbiased. If instead systematic error only redistributes within participants, filtering can add up to 0.58°. Unchanged clinical error from such small-cohort predictors therefore cannot show that quality filtering preserves the assessed movement.

I. INTRODUCTION

Video-based movement analysis enables quantitative gait assessment outside the laboratory. Single-camera models estimate gait measures and clinical indices in cerebral palsy [1]–[3], and multiview smartphone systems recover kinematics against laboratory references [4]. Pose-based gait analysis has been validated in the image plane [5] and across camera views, clinical populations, and sensitivity to change [6], and learned gait representations have been related to biomechanical descriptors [7]. For rehabilitation, however, what matters is the validity of the person-level summary, not only the accuracy of each pose estimate: home monitoring and robot-assisted therapy increasingly track progress from such summaries, and a summary that shifts with data quality can mimic or mask change.

Which observations should form that summary? Low-confidence detections and occlusions degrade gait estimates, and markerless capture shows higher inter-trial variability than marker-based capture [8]. Yet difficult-to-track movement can be part of the behavior being assessed: atypical appearance challenges detectors [9], and movement uncertainty itself has been used to detect gait abnormality [10]. Discarding low-confidence observations can therefore reduce measurement error while shifting the sample of movement summarized. Calibrated uncertainty [11] addresses whether a confidence score tracks reconstruction error, but not whether the retained observations represent the full record. Selective prediction shows a related risk: aggregate gains after abstention can hide worse performance for subgroups [12], [13]. Here selection operates within a person; every participant remains in the analysis.

Isolating this effect requires two controls. First, the number of observations must be matched, because the number and choice of gait cycles alone alter measurement error [14]; a selected subset must be compared with a random subset of the same size, not with the full record. Second, an independent reference is needed to separate measurement error from genuine movement variation.

We ask whether selecting high-quality observations reduces local measurement error while shifting the person-level endpoint away from an independent full-record reference (Fig. 1). The contributions are:

• In a Parkinson-related cohort, confidence selection shifted the observed movement summary more than budget-matched random selection while held-out Mini-BESTest error stayed flat, and a candidate proportionate-coverage policy reduced that shift; an NF2-related schwannomatosis cohort showed no selection shift.

  • A within-participant decomposition of full-record endpoint error into measurement error and selection shift, an accounting identity used as an evaluation tool rather than a new estimator.

  • A simulation with known components on the clinical window structure that explains when confidence filtering helps and when it harms the endpoint, and places the Parkinson-related pipeline on that map.