Manuscript Offprint

arXiv:2610.40094

RepConTUR: A Report-Conditioned Volumetric Multimodal Model for Abdominal Tumor Segmentation

Seunghwan Lee, Sangjoon Park, Jongmin Lee, Yoon Jo Kim, Wonyoung Cho, Jin Sung Kim, Han Joo Chae

Abstract

Tumor delineation is required for radiotherapy planning, yet automatic segmentation is limited by errors, predominantly false positives, that distort dose and increase editing time. The radiology report accompanies the scan and localizes disease at the suborgan level, but existing text-promptable models condition on short referring phrases, and most operate in 2D. We present RepConTUR, a single native-3D early-fusion multimodal model that conditions volumetric abdominal tumor segmentation on the narrative report. We extend AbdomenAtlas 3.0 to a suborgan-level promptable segmentation dataset and generate report-based VQA pairs, yielding four report-derived tasks on the same annotations: referring segmentation (RES), report-grounded segmentation (GSEG), report generation (RRG), and visual question answering (VQA). We train RepConTUR, comprising a 3D CT encoder, an early-fusion language model, and a native-3D segmentation module, jointly on the four tasks. Across liver, kidney and pancreas, RepConTUR attains the highest Dice similarity coefficient (DSC), instance-wise precision, and detection F1 among the text-promptable baselines, and adding the report raises mean precision while leaving recall comparable. Against two vision-only specialists, nnU-Net and the report-supervised R-Super, RepConTUR attains the highest value on every in-domain metric for liver and pancreas and the highest mean DSC, recall, precision, and detection F1 over the four out-of-distribution public cohorts. Ablations indicate that conditioning on the narrative report raises detection F1 from 0.499 to 0.528 within the same model, that joint GSEG training raises RES F1 from 0.450 to 0.482, and that the native-3D segmentation module raises GSEG F1 from 0.139 to 0.528 over its 2D counterpart. Code is available at github.com/Oncosoft-Research/RepConTUR.

1. Introduction

Tumor delineation is a required step in radiotherapy planning, but manual contouring is labor-intensive and shows large inter-observer variability [21, 52, 58]. Unlike diagnostic reading, radiotherapy target contouring routinely combines the diagnostic scan with its radiology report, as the report contains rich information about the tumor, including its anatomical location, size and stage [1, 7, 20, 29]. This makes the report a natural conditioning signal for automatic tumor segmentation.

Vision-only deep learning models remain the standard approach to tumor segmentation, and their accuracy is reported mainly by the volumetric Dice similarity coefficient (DSC), which underrepresents instance-wise recall and precision [37]. On the LiTS liver-tumor benchmark, the top method reports a tumor Dice of 0.702, yet its instance-wise precision is only 0.148 [6]. In radiotherapy, instance-wise recall and precision are as clinically important as DSC. False positives in particular distort the dose distribution and raise normal-tissue exposure and toxicity risk [44], and these errors increase the editing time [57]. A separate line of work uses the radiology report as training-time supervision to improve tumor detection and segmentation. Report-derived tumor count and size penalize inconsistent predictions through auxiliary losses [3], reported location provides weak labels [23], and the report yields pseudolabels [9]. However, these models still segment from the image alone at inference time [64], so the report cannot directly inform the prediction.

Text-guided segmentation models have achieved strong results on referring segmentation (RES) and grounded segmentation (GSEG) [31, 33, 45, 63, 76]. Some works adopt a dual-encoder design that encodes the language prompt and the image in separate branches and fuses them at the decoder [47, 70]. On the other hand, multimodal large language model (MLLM)-based segmentation models fuse image and text early and reason over both jointly within the

∗^{*}Corresponding author.

language model [31, 61]. Yet both are designed for short target descriptions — class names or referring phrases — and do not exploit long-form textual context. BiomedParse v2, for example, conditions on an organ-level prompt (e.g., “tumor in liver CT”), which cannot indicate a detailed intra-organ region and may not capture suborgan-level information [70, 71]. A report instead specifies suborgan location, which may help suppress false positives elsewhere in the same organ [17, 18]. Furthermore, existing MLLM-based medical segmentation models are also mostly 2D [61], limiting their abilities to interpret report information that refers to 3D context [11, 30, 38].

Multitask learning can improve a target task when the tasks are related, although the gain depends on task affinity [10, 50, 55]. Unified vision–language models train localization and language tasks in one network [59, 68], and an MLLM-based segmentation model is a natural fit for such joint training. In the medical domain, UniBioMed trains segmentation jointly with VQA and report generation and reports improved segmentation Dice [61]. The report can therefore also serve as a joint-training signal.

We propose RepConTUR, an MLLM-based 3D report-conditioned tumor segmentation model that grounds segmentation on the report to improve both segmentation accuracy and instance-wise detection (Fig. 1). Our contributions are threefold:

• Report-conditioned segmentation. We condition segmentation on a suborgan-level referring phrase and an optional free-form narrative report, rather than a short class name alone. To the best of our knowledge, RepConTUR is the first 3D referring/grounded segmentation model to condition on such report context. We introduce suborgan-level mask and prompt design aligned to narrative free-form radiology reports, and implement it for abdominal tumors.

• A native 3D MLLM for report-conditioned abdominal tumor segmentation. We build on prior MLLM architectures and extend them with native-3D vision modules. The MLLM vision encoder and segmentation module are all 3D, and visual tokens are processed jointly with the report text from the first LLM layer, so vision and text are reasoned over jointly.

• Report-derived multitask dataset and multitask learning. From AbdomenAtlas 3.0 [4] tumor masks and their reports we construct a unified four-task dataset. Report-matched suborgan localization produces the RES and GSEG targets, and the report is converted into radiology report generation (RRG) supervision and LLM-verified VQA pairs. We jointly train all four tasks on a single backbone. Cumulative task ablations show that report-grounded segmentation training improves RES performance, while adding report generation and VQA further increases detection F1.

References (73)