arXiv:2610.40252stat.MEOct 2026

Manuscript Offprint

arXiv:2610.40252

Conformal Annotation with Randomized Expert Review: Application to Online Cell-Type Labeling

Xuhe Zhang, Zhi Huang, Ying Jin

Abstract

Artificial intelligence (AI) models can accelerate cell-type annotation in digital pathology, but safely scaling their use requires determining—with error control—which model-generated labels can be accepted without expert review. This is challenging in evolving workflows because cell morphology and type composition may change across tissue regions and slides, making one-time calibration unreliable. We propose Conformal Annotation with Randomized Expert review under Distribution shift (CARED), a distribution-free framework that leverages randomized expert audit to achieve long-run error control for AI-assisted annotation under distribution shift. For each incoming batch, CARED uniformly selects a subset of cases for expert review and uses the acquired labels to calibrate later decisions. Among unreviewed cases, CARED determines a subset of them to safely skip expert labeling, while suggesting candidate labels for the others for downstream resolution. We prove that this workflow provides long-run control of cumulative error over both the full stream and the cells outside of the audit sample, without stationarity or exchangeability assumptions. We further enhance the framework by introducing class-conditional guarantees to ensure error control within important but rare cell types, together with a utility module to target more automatic resolutions, smaller candidate sets, and greater biological coherence, without compromising validity. Experiments on pancreas, lung, and ovary annotation streams, together with a stream constructed from real expert annotations, show that CARED controls the cumulative errors while a substantial fraction of cells (up to 70%) bypass expert review.

Keywords: Conformal inference; Trustworthy medical AI; Distribution shift; AI annotation

1 Introduction

Expert labeling underlies a broad range of scientific, engineering, and medical tasks. Experts examine and assign labels that guide downstream analyses or decisions on individual cases; the resulting labeled cases also form the datasets used to train and evaluate predictive models (Deng et al., 2009; Gulshan et al., 2016). Artificial intelligence (AI) models can accelerate this process by producing predictions at scale which, when sufficiently accurate, can serve as labels (Goel et al., 2023; Gilardi et al., 2023), thereby reducing or even bypassing expert review. However, accepting those “labels” without expert review leaves the prediction errors fundamentally unobserved (Northcutt et al., 2021; Bernhardt et al., 2022). This creates a tension between reducing expert effort and maintaining label quality (Candès et al., 2025; Huang et al., 2025).

We study this problem in image-based cell-type annotation, an important task in biomedical research and digital pathology (Ergen et al., 2024; Hou and Ji, 2024). In this task, a digitalized pathology slide contains many cells, each of which must be assigned a cell type to support downstream analysis (Angus et al., 2025;

*Correspondence to yjinstat@wharton.upenn.edu

Kim et al., 2026; Gaffney, 2025). Emerging AI systems now enable collaboration between pathologists and cell-level AI models: as pathologists proceed across a slide image, the model proposes labels for the cells, which can be reviewed by the pathologists to assign the labels. For example, the TissueLab platform (Li et al., 2025a) developed by the author(s) allows pathologists to navigate the slides and annotate cells with the support of an in-house AI model (Xu et al., 2025). Such collaborative systems streamline expert annotation, but every model proposal must still be inspected and finalized by a pathologist. Here, our goal is to identify cells whose AI predictions can be accepted without expert review while still ensuring long-run error control.

Recent work has begun to provide statistical guarantees for deciding which model-generated labels can be accepted without expert review. Assuming access to i.i.d. (or a uniform random subset of) labeled data, PAC Labels (Candès et al., 2025) calibrates a criterion for accepting AI labels in the unlabeled data while controlling the overall error rate, whereas Conformal Labeling (Huang et al., 2025) uses selective inference (Jin and Candès, 2023) to select AI labels for unlabeled data while controlling the false discovery rate among the selected labels. Their success relies on the data generating process ensuring the AI labeling errors in the labeled data are representative of the unknown errors in the new samples.

However, as a pathologist moves across regions of a whole-slide image (WSI) and then across slides, the cells may differ in both morphology and cell-type composition. Additional variation can arise from changes in specimen preparation, imaging devices, and data processing (Tellez et al., 2019; Stacke et al., 2020; Howard et al., 2021; Aubreville et al., 2023). Therefore, a rule calibrated on earlier data may fail to provide valid error control as annotation proceeds. Figure 1 visualizes such workflow shift using the NuClass model of Xu et al. (2025). We partition a pancreas WSI containing more than 10510^{5} cells into 206 approximately equal-sized spatial regions. We then order the regions to mimic a pathologist's traversal across neighboring fields, with adaptive changes in viewing resolution; panel (a) shows this annotation order. For this diagnostic, we use the held-out label of each cell to compute the NuClass score assigned to its true class. Panel (b) reports the within-fraction empirical α\alpha-quantiles of these scores, separately for each cell type. The dashed rose curve in each panel, read against the right vertical axis, gives the cell-type proportion within each fraction. The composition of cell types varies substantially, irregularly, and at times abruptly across batches. Moreover, the in-class distributions also vary substantially: if the cells within the same type are identically distributed across batches, the quantile curves would remain approximately constant (up to sampling variation). Instead, the curves fluctuate markedly over the annotation order. These within-cell-type distributional changes, together with the composition shifts, make one-time calibration unreliable.

Figure

(a)

(b)

Figure 1: Evidence of workflow shift in image-based cell-type annotation. A pancreas whole-slide image containing more than 10510^5 cells is partitioned into 206 approximately equal-sized spatial fractions. (a) Spatial locations of cells, with color indicating the order in which the fractions enter the annotation workflow. (b) Empirical α\alpha-quantiles of the NuClass score assigned to the true class, shown separately by cell type for α∈{0.05,0.10,0.20}\alpha \in \{0.05, 0.10, 0.20\}. The dashed rose curve in each panel (right vertical axis) shows the corresponding cell-type proportion. Its irregular and, at times, abrupt changes reveal shifts in cell-type composition, while the variation in the solid quantile curves reveals within-cell-type score-distribution changes over the workflow.

Figure

Figure 2: Schematic of the CARED workflow. (a) Incoming cell batches are processed sequentially: CARED forms prediction sets, cells with set size at most one skip expert labeling, and a random audit set is reviewed to update the conformal level for subsequent batches. (b) Zoom-in of the prediction set generation process highlighted by the gray dashed box in panel (a), where prior review information updates the conformal level and the scoring model with the utility module produces prediction sets for the incoming batch.

References (78)