arXiv:2610.40302cs.CVOct 2026

Manuscript Offprint

arXiv:2610.40302

Self-training for cross-centre coronary vessel segmentation in X-ray angiography using pre-contrast frame subtraction

Danial Moafi, Aida Moafi, Mostafa Aryafar, Ashkan Sami, Maryam Aryafar

Abstract

Deep learning models for coronary vessel segmentation in X-ray angiography often perform poorly on data from centres that were not represented in training. Apart from differences in equipment, the labels of the largest public dataset (ARCADE) are incomplete, as only the segments defined in the SYNTAX score are annotated. In this study, we evaluated whether self-training with pseudo-labels can improve performance on external data without additional manual annotation. Pseudo-labels were generated from two sources, namely the predictions of an nnU-Net model trained on ARCADE and a contrast map obtained by subtracting a pre-contrast frame from the same sequence. The nnU-Net predictions were extended along the contrast map, and pixels detected only in the subtraction image were assigned an ignore label and excluded from the loss. Six models were trained and tested on ARCADE and on two external datasets (XCAD and XACV). All first-round models initialised with the baseline predictions performed better than both the baseline and a control model fine-tuned for the same number of epochs. The model trained on the XCAD pool improved the macro-averaged Dice score by 2.7 points (95% CI 2.3–3.2), while the control decreased it by 0.6 points. A second round of self-training did not lead to further improvement. When an external model trained on 50 fully annotated images was used to generate the initial labels, the XCAD Dice score increased from 0.623 to 0.745 without any XCAD labels, although performance on XACV did not improve because large main vessels were missed. These results suggest that the benefit of self-training depends largely on the sensitivity of the model used to generate the initial pseudo-labels.

Keywords: coronary angiography, vessel segmentation, self-training, pseudo-labels, domain shift

1. Introduction

Quantitative coronary angiography (QCA) is used to assess the severity of coronary stenoses on invasive X-ray angiograms, and automated QCA requires accurate segmentation of the coronary arteries in each analysed frame. Deep learning methods such as nnU-Net (Isensee et al., 2021) perform well on this task when sufficient annotated data are available. However, annotated angiography datasets are few and relatively small. The largest public dataset, ARCADE (Popov et al., 2024), contains 1,000 annotated frames, and its annotations cover only the coronary segments defined in the SYNTAX score. Side branches and distal vessels outside the score are labelled as background.

Segmentation models trained on data from a single source often perform worse on images from other centres and vendors. For coronary angiography, external datasets with complete vessel annotations, such as XCAD (Ma et al., 2021) and XACV (Wu et al., 2025), allow this to be measured. When the training labels are incomplete, as in ARCADE, a model may also learn to leave unlabelled vessels unsegmented, which would further reduce sensitivity on fully annotated external data. Collecting complete annotations from additional centres is time-consuming and expensive, so methods that can make use of unlabelled images are of practical interest.

Several self-supervised and unsupervised methods have been proposed for vessel segmentation in angiography (Ma et al., 2021; Kim et al., 2023; Shi et al., 2023). Self-training with pseudo-labels (Lee, 2013; Xie et al., 2020) is a simpler alternative, in which a trained model is used to label new images and is then retrained on these labels. A known problem with this approach is confirmation bias, since the model is trained to repeat its own mistakes. One way to reduce this effect is to add a second, independent source of labels.

In coronary angiography, a second source of information is often available within the acquisition itself, because most sequences include frames recorded before the contrast agent arrives. Vesselness filters have previously been used to generate noisy training labels (Zhang et al., 2020), and Zeng et al. (2024) used learned single-frame subtraction to pretrain a segmentation model (DeepSA). To our knowledge, subtraction of a pre-contrast frame from the same sequence has not yet been used as an additional source of pseudo-labels in a self-training framework.

The aim of this study was to evaluate whether self-training with pseudo-labels from an nnU-Net model and from pre-contrast frame subtraction can improve coronary vessel segmentation on external datasets without new annotations. We also examined the effect of a second self-training round and of the choice of the initial model.

Figure

Figure 1: Overview of one self-training round. The baseline nnU-Net (teacher, f0f_{0}) segments the contrast-filled frame xtx_{t} to give the seed mask S. The pre-contrast frame x0x_{0} of the same sequence, after registration to xtx_{t}, is subtracted to give the contrast map C, along which S is extended by region growing (G). In the pseudo-label Y, pixels in S are labelled vessel (except low-contrast components, which are labelled ignore), pixels in G\S are labelled ignore, and all remaining pixels are labelled background. The student is initialised from the teacher weights and trained on the pseudo-labelled frames (U) together with the labelled ARCADE images (A), with ignore pixels excluded from the loss.