arXiv:2610.40478cs.CVOct 2026

Manuscript Offprint

arXiv:2610.40478

Accurate MRI-free PET Quantification and Reliability Assessment via CT-to-MRI Synthesis and Conformal Prediction

Jungwoo Seo, Seung Yun Choi, Kun Ho Lee, Seun Jeon, Byoung Seok Ye, Jiook Cha

Abstract

Standardized uptake value ratio (SUVR) quantification of amyloid PET commonly relies on a subject-specific T1-weighted MRI, yet a usable MRI is not always available. We therefore combined CT-to-MRI synthesis with conformal prediction for MRI-free PET quantification with reliability assessment. A slice-consistent Brownian Bridge Diffusion Model was strengthened with multi-dataset training and data-source conditioning to enrich the anatomical prior learned from MRI, and with expanded multi-slice CT context to exploit the through-plane continuity of subject-specific anatomy in CT. Synthetic MRI was used for FreeSurfer-based anatomical parcellation and PET quantification, while deep-ensemble uncertainty was calibrated with conformal prediction to estimate a plausible range for the corresponding real MRI-based SUVR. On 11{}^{11}C-PiB PET from OASIS-3, the proposed method achieved the highest synthesis and parcellation fidelity among the compared methods. Mean cortical SUVR from the proposed synthetic MRI agreed closely with the real MRI-based reference (MAE 0.016±0.0150.016 \pm 0.015, Pearson r=0.9987r = 0.9987) and yielded the same amyloid-positivity classification as the real MRI in all 87 test subjects at the prespecified cut-off. Conformal prediction achieved empirical coverage close to the prespecified levels, and at 90% target coverage, 85 of 87 subjects had prediction intervals that supported an unambiguous amyloid-positivity decision. Zero-shot evaluation on an independent external cohort showed that the proposed CT-to-MRI model could support PET quantification without retraining, although conformal calibration required target-cohort recalibration to recover the intended coverage. These findings support CT-to-MRI-based MRI-free PET quantification as a promising approach for providing accurate SUVR measurements and an explicit assessment of their reliability.

Keywords: amyloid PET, MRI-free PET quantification, CT-to-MRI synthesis, diffusion models, conformal prediction, uncertainty quantification

1. Introduction

Amyloid- β\beta deposition is one of the earliest detectable pathological changes in Alzheimer's disease and may begin years before measurable cognitive decline [1, 2]. Positron emission tomography (PET) enables this molecular pathology to be visualized and quantified in vivo [3]. As Alzheimer's disease is increasingly defined and staged according to its underlying biological pathology, biomarker-based assessment has become increasingly important [2]. Quantitative amyloid PET can characterize overall pathological burden, regional deposition patterns relevant to disease staging [4], and longitudinal changes in amyloid accumulation [5].

Amyloid PET is commonly quantified using the standardized uptake value ratio (SUVR), which normalizes tracer uptake in cortical target regions to uptake in a relatively amyloid-sparse reference region. Accurate SUVR estimation requires the target and reference regions to be defined according to each subject's anatomy. Because PET has limited spatial resolution and weak anatomical contrast, conventional quantification pipelines typically rely on a subject-specific T1-weighted MRI for anatomical parcellation [6, 7].

A usable MRI, however, is not always available because of implanted devices, claustrophobia, patient motion, acquisition burden, or additional cost [8]. This has motivated MRI-free PET quantification methods based on PET spatial normalization [9, 10, 11], low-dose attenuation CT [12, 13, 14], or CT-to-MRI synthesis [15]. PET-only methods provide limited subject-specific anatomy, whereas CT offers insufficient soft-tissue contrast for fine cortical parcellation. CT-to-MRI synthesis is therefore particularly promising: it can complement the anatomical evidence available in CT with structural knowledge learned from MRI while retaining established MRI-based segmentation and quantification pipelines.

Despite this promise, CT-to-MRI synthesis remains intrinsically ill-posed because CT provides substantially less information than T1-weighted MRI about gray-white matter boundaries and cortical folding. Multiple anatomically plausible MR images may therefore be consistent with the same CT observation, making faithful recovery of subject-specific fine anatomy inherently challenging. More generally, medical image translation mod-

∗^{*}Corresponding authors.

Email addresses: jungwoo.seo95@gmail.com (Jungwoo Seo), seun.jeon@gmail.com (Seun Jeon), ROMEL79@yuhs.ac (Byoung Seok Ye), connectome@snu.ac.kr (Jiook Cha) els can produce visually plausible outputs without necessarily preserving all subject-specific anatomical features [16]. This ambiguity is particularly important for MRI-free PET quantification because anatomical errors in the synthesized MRI can propagate through brain parcellation and ultimately affect regional SUVR estimates.

Conceptually, CT-to-MRI synthesis can be viewed as estimating the conditional distribution of possible MR images given the observed CT:

p(MRI∣CT)∝p(CT∣MRI)p(MRI).p(\mathbf{M R I}\mid\mathbf{C T})\propto p(\mathbf{C T}\mid\mathbf{M R I})p(\mathbf{M R I}).

Here, p(MRI)p(\text{MRI}) represents anatomical prior knowledge learned from MRI data, whereas p(CT∣MRI)p(\text{CT} \mid \text{MRI}) reflects compatibility with the subject-specific anatomical information available in CT. Faithful synthesis therefore requires both a sufficiently rich anatomical prior and sufficient subject-specific evidence from the input CT to identify the anatomy most consistent with the individual subject.

Previous work demonstrated that CT-derived synthetic MRI can be incorporated into an MRI-based PET quantification pipeline, establishing the feasibility of CT-to-MRI-based MRI-free PET quantification [15]. Separately, slice-consistent Brownian Bridge diffusion improved CT-to-MRI synthesis by jointly modeling adjacent slices and promoting through-plane consistency [17, 18]. Nevertheless, the anatomical prior learned from limited training data and the subject-specific information extracted from a narrow CT input may still be insufficient for recovering complex individual cortical anatomy.

In this study, we strengthen both sources of information. We use multi-dataset CT–MRI training to learn from a broader distribution of brain anatomy and introduce data-source conditioning so that this broader prior can be learned without conflating dataset-specific image characteristics. We also provide a wider multi-slice CT context to make greater use of subject-specific anatomical information available across adjacent slices. We hypothesize that a richer anatomical prior together with stronger subject-specific CT constraints will produce more faithful synthetic MRI and, in turn, improve anatomical parcellation and MRI-free PET quantification.

Existing MRI-free PET quantification methods, including CT-to-MRI-based quantification [15], are typically evaluated by their overall agreement with the real MRI-based reference but do not provide, for each subject, a plausible range for the SUVR that would have been obtained with that subject's real MRI. High overall agreement, however, does not indicate how reliable an MRI-free SUVR estimate is for an individual subject. In the intended MRI-free setting, the real MRI is unavailable, so the discrepancy between an MRI-free SUVR estimate and the corresponding real MRI-based value cannot be directly measured. This is particularly important near an amyloid-positivity decision cut-off, where even a small quantification error may affect the resulting classification.

To address this limitation, we combine deep-ensemble uncertainty with split conformal prediction [19, 20, 21, 22]. Model-derived uncertainty has been used to characterize output reliability in medical image segmentation [23] and neuroimage enhancement [24], while conformal prediction has been applied to assess the reliability of diagnostic predictions in AI-assisted pathology [25]. In our setting, these ideas are used to assess the reliability of CT-to-MRI-based PET quantification by estimating a plausible range for the corresponding real MRI-based SUVR. Comparing this range with the amyloid-positivity decision cut-off allows cases to be identified as confidently negative, confidently positive, or indeterminate, providing a way to assess decision reliability when the real MRI is unavailable.

For clinical applicability, the proposed approach should remain reliable beyond the datasets used for model development. We therefore evaluated zero-shot generalization on an independent external cohort and examined whether the conformal calibration could also be transferred to this new setting.

Accordingly, this study makes four main contributions:

  1. Improved CT-to-MRI synthesis. We strengthen slice-consistent CT-to-MRI synthesis by enriching the anatomical prior learned from MRI through multi-dataset training with data-source conditioning, and by exploiting the through-plane continuity of subject-specific anatomy in CT through an expanded multi-slice CT context.

  2. More accurate MRI-free PET quantification. We show that the improved anatomical inference yields more faithful anatomical parcellation and closer agreement with real MRI-based composite and regional SUVR quantification than PET-only and CT-based baselines and existing CT-to-MRI-based approaches.

  3. Reliability assessment using conformal prediction. We construct calibrated prediction intervals for composite and regional SUVR estimates and use these intervals to identify cases in which the reliability of an MRI-free amyloid-positivity decision is uncertain.

  4. Zero-shot external validation. We evaluate CT-to-MRI synthesis, PET quantification, and conformal reliability assessment on an independent external cohort never used for training, demonstrating the feasibility of using the synthesis model for PET quantification without retraining and showing that conformal calibration requires target-cohort recalibration.

The complete approach is evaluated using 11{}^{11}C-PiB amyloid PET from OASIS-3 [26] and, zero-shot, using 18{}^{18}F-florbetaben PET from the independent Gwangju Alzheimer's & Related Dementias (GARD) cohort [27], with PET quantification based on each subject's real MRI serving as the reference in both cohorts.

References (26)