Manuscript Offprint
arXiv:2610.36725On Shaky Ground: Characterising Non-Rigid Base Effects in Mobile Manipulation
Abstract
Mobile robot manipulators extend contact-task capability beyond the workspace of fixed robot installations, but their bases must also sustain the forces generated by the task. On lightweight platforms, base motion and support compliance can change the force and motion realised at the workpiece. How these non-rigid base effects manifest during sustained contact remains insufficiently characterised. This paper investigates non-rigid base effects in mobile robot manipulators through a sanding case study combining exploratory simulation with experiments on two lightweight, unactuated wheeled testbeds. Joint measurements of contact force, tool motion, and base vibration show that sustained contact coexisted with substantial task error: under low base-ground resistance, only 54–70% of a 100 N command was realised, with tool-centre-point errors reaching 100 mm. Increasing base-ground resistance during contact improved force realisation and arrested further tool displacement, while base vibration did not vary consistently with force-tracking error in the tested conditions. These observations illustrate how non-rigid base behaviour can affect contact-task execution and highlight the value of examining force, motion, and vibration together when characterising lightweight mobile manipulation.
1 Introduction
Fixed-base industrial manipulators are widely used for contact-rich processes such as sanding, polishing, and assembly. Their rigid bases enable accurate motion and force control, but limit operation to a fixed workspace. Mounting the manipulator on a mobile robot extends the operating workspace and allows the tool to be carried between work areas, making mobile manipulators

Figure 1: Contact forces acting on a mobile manipulator during sanding. The contact forces and and the tool torque are transmitted through the manipulator to the base and balanced by the ground support forces and the friction forces , with the weight mg acting at the centre of mass (CoM). Limited traction and compliance at the base-ground interface can lead to base motion, loss of stability, and vibration.
attractive for tasks involving large or distributed structures such as aircraft, ships, and building surfaces [Tao et al., 2019].
This mobility, however, introduces additional challenges in contact tasks. Contact forces are transmitted through the manipulator and the mobile base to the ground. Existing mobile machining systems often use deliberately heavy automated guided vehicles or track-mounted platforms [Möller et al., 2017; Zhao et al., 2022; 2023; Yang et al., 2024] to increase stiffness and stability during contact. Lightweight mobile platforms are easier to move and deploy, but their lower mass, limited wheel traction, and compliance at the wheel-ground interface can lead to base motion and vibration under contact load.
Figure 1 illustrates these effects. Normal and tangential forces at the sanding tool are transmitted through the manipulator to the base. If the horizontal reaction exceeds the available traction, the base can slip. If the resultant wrench moves the zero-moment point outside the support polygon, the system can lose static stability. Compliance in the tyres, suspension, or ground surface can also introduce oscillation of the base and manipulator. These behaviours are collectively referred to as non-rigid base effects. They affect contact-task performance because base motion contributes to tool centre point (TCP) error [Zhao et al., 2021], while base vibration and deformation can disturb the contact force. Under force control, the arm commands tool advance relative to its base, whereas the contact force depends on the tool-workpiece compression. Base motion away from the workpiece under the contact reaction can therefore absorb part of the commanded advance and contribute to a sustained force shortfall and to undesired tool motion relative to the workpiece, even while contact is maintained.
Existing work has examined mobile-manipulator stability, wheel slip, machining accuracy, compliance, and contact-force control, but there is limited experimental characterisation of how base motion manifests simultaneously in realised contact force and tool motion relative to the workpiece during sustained contact on lightweight mobile manipulators. This paper addresses this gap through a sanding case study combining exploratory simulation with experiments on two instrumented lightweight wheeled testbeds. Their unactuated bases serve as mechanical surrogates for mobile robot bases (Section 4.1). The study addresses three questions: (i) What non-rigid base effects arise under contact forces? (ii) How do base-environment coupling, arm posture, tool excitation, and support compliance affect force realisation, tool motion, and base vibration? (iii) Do the principal response patterns persist across different lightweight platforms?
The contributions are:
-
An experimental characterisation of non-rigid base effects in force-controlled sanding, showing that sustained contact coexisted with force shortfall and TCP error, and that increasing base-ground resistance during contact improved force realisation and arrested further tool displacement;
-
An assessment of how these effects vary with commanded force, arm posture, tool excitation, and support compliance on two lightweight mobile platforms, with base-vibration measurements providing a complementary view of the dynamic response.
These measurements identify force and motion responses that future active compensation strategies on mobile robots would need to address.
2.1 Robotic Surface Finishing
Robotic grinding and sanding require simultaneous path tracking and regulation of the tool-workpiece interaction. Process studies relate abrasive properties, tool speed, feed rate, and normal force to material removal and surface quality [Torrance, 1990; Luo et al., 2014; Zhang et al., 2006; Li et al., 2024]. Reviews of mobile robotic machining and grinding identify limited structural stiffness, motion accuracy, and process vibration as persistent limitations [Tao et al., 2019; Li et al., 2026].
Previous studies have addressed grinding vibration through feed-speed and force control, and through posture selection [Dimo et al., 2001], force-controlled end-effectors for flexible workpieces [Wang et al., 2021], and tool-holder compliance design [Asada and Goldfine, 1985]. These approaches mainly address vibration and compliance associated with the manipulator, tool, or workpiece, while the influence of a mobile base and its interaction with the ground has received less attention.
2.2 Mobile Machining and Base Stability
Mobile robotic machining extends the workspace available for large aircraft, ships, rail vehicles, and other large-scale structures [Tao et al., 2019; Li et al., 2026]. Existing systems commonly use heavy automated guided vehicles, rail-mounted bases, external metrology, or compliant grinding heads to recover machining accuracy [Möller et al., 2017; Zhao et al., 2021; 2023; Yang et al., 2024]. These systems typically rely either on heavy mobile platforms or on specially designed, structured environments to provide sufficient stability, reducing the mobility and ease of deployment that motivate lightweight mobile manipulators.
The tip-over stability of mobile manipulators has a substantial theoretical foundation. Papadopoulos and Rey [1996] introduced the force-angle stability margin for systems subject to external and inertial loads. Garnier et al. [2018] analysed the dynamic tip-over stability of a mobile manipulator for naval-manufacturing tasks and showed that joint speed, joint acceleration, and structure height affect its stability. More recent work derives individual wheel support forces for direct monitoring of contact loss [Petrović and Mattila, 2022], while experiments with a UR5 on a mobile base show that high, cantilevered payloads can destabilise the platform during navigation [Bostelman and Hong, 2017]. Hence, force effects on the mobile base are worth investigating.
Wheel slip is often excluded by the pure-rolling assumption. Galicki [2023] treated wheel-slip reaction forces and unstructured end-effector forces as disturbances in finite-time task-space control of mobile manipulators. Such slip must therefore be accounted for when lightweight robot platforms are adopted for contact tasks.
2.3 Base Compliance and Physical Interaction
Wang and Carmichael [2024] experimentally varied mobile-base rigidity during physical human–robot collaboration and found that base compliance affects task accuracy and human interaction. Their results show that the mechanical properties of the mobile base and its contact with the ground can directly influence physical interaction.
Gao et al. [2026] investigated dynamic base-arm coupling in mobile robot-environment interaction and developed a motion/force controller to compensate for the resulting disturbances. Their wall-cleaning experiments considered force-controlled interaction while the mobile base remained in motion.
Together, these studies show that base compliance and base motion can significantly affect physical interaction. However, experimental characterisation of how base motion manifests jointly in realised contact force and tool motion relative to the workpiece remains limited for sustained force-controlled contact on lightweight platforms intended to remain stationary. The present study examines this setting by measuring contact force, tool motion, and base vibration together.
3 Exploratory Simulation
The simulation is used as an exploratory tool to identify potential failure modes, examine how they vary with different system and task parameters, and inform the physical experiments (see Section 4).
3.1 Environment and Control
The simulation uses MuJoCo [Todorov et al., 2012] with a UR10 manipulator on a differential-drive base facing a rigid vertical workpiece, as shown in Figure 2a. The wheels and base structure are modelled as rigid, so the simulation captures traction and stability limits but does not include compliance at the wheel-ground contacts.
The end-effector carries a rotating sanding tool with a compliant pad and a virtual force/torque sensor. The pad is modelled using multiple MuJoCo contact points with compliant contact parameters, providing an approximate distributed contact over the sanding surface. A hybrid force-position controller regulates the normal contact force while controlling tangential motion [Siciliano and Villani, 1999]. Contact force, wheel friction, arm posture, mass distribution, and tool excitation are varied to examine the resulting failure modes.
3.2 Observed Failure Modes
Heuristic parameter sweeps produced three repeatable behaviours (Figure 2). First, contact excitation produced oscillation of the tool and base around the target pose. The oscillation increased with tool-workpiece friction, commanded normal force, and arm extension, while tool speed changed the dominant excitation frequency. These observations led to the use of separate force-variation and base-vibration metrics in the physical experiments.
Second, base slip occurred when the tangential forces required at the wheel-ground contacts exceeded the available traction. Slip became more likely with larger contact loads, lower wheel-ground friction, and postures that reduced the load on the driven wheels. This also motivated measuring tool motion and base response separately, since tool-path error alone cannot distinguish base motion from manipulator tracking error.
Third, the simulated robot lost stability when the combined gravitational and contact wrench moved the zero-moment point outside the support polygon. Extended postures and unfavourable mass distributions reduced the stability margin, identifying loss of stability as another potential failure mode under contact load.
These observations are qualitative. The simulated contact parameters were not identified from the physical platforms, and the rigid-wheel model does not represent compliance in the tyres, platform, or supporting surface. Such model mismatch is a source of the simulation-to-reality gap discussed in robotics [Zhao et al., 2020]. The simulation is therefore used to identify plausible failure modes and qualitative trends rather than to predict the hardware results quantitatively.
4 Physical Experiments
The physical study uses two lightweight platforms, the cart and the trolley (Table 1), in three experiments on the same force-controlled sanding task (Section 4.4). The experiments vary resistance to base motion and support compliance to characterise the resulting contact response. The two constructions provide contrasting support conditions for examining whether the principal effects persist across platforms.
Neither platform is an actuated mobile robot. They are used as surrogates for a lightweight mobile-robot base because they provide variable manipulator attachment points, are low cost, and allow repeatable base-ground conditions.

(a) Robot and workpiece
(b) Compliant sanding tool

(c) Base slip
(d) Loss of stability
Figure 2: Simulation environment and representative non-rigid base effects.
| Simulation | Cart | Trolley | |
|---|---|---|---|
| Arm | UR10 model | UR10 | UR5 |
| Base | Rigid wheels | Aluminium | Plywood |
| Support | Rigid floor | Concrete | Foam |
| Resistance | Varied | Low, high | Low, high |
| Sander speed | Varied | Low, high | High |
Table 1: Simulation model and physical platforms.
4.1 Platforms
The cart carries a UR10 on an aluminium frame and deck with four lockable wheels, on a concrete floor (Figure 3a).
The trolley carries a UR5 on a lighter plywood deck with four lockable wheels (Figure 3b). A foam layer beneath the trolley provides a repeatable compliant support that stands in for compliant tyres, suspension, or soft ground, the non-rigid components motivating the base-compliance study of Wang and Carmichael [2024].
4.2 Experimental Setup
Both platforms use a wall-mounted panel and the same wrist-mounted RYOBI ROS300-S random-orbital sander (300 W, 125 mm pad), operated at its lowest and highest dial settings, referred to as low and high tool speed. The base-ground resistance is set low by leaving the wheels free and high by locking them. Locking the wheels increases the resistance to base motion but does not rigidly fix the platform to the ground; compliance in the wheels, deck, and support remains.
A wrist-mounted Axia80-M20 six-axis force/torque sensor (ATI Industrial Automation; effective resolution 0.1 N and 0.005 Nm) measures contact force. A deck-mounted Orientus inertial measurement unit (Advanced Navigation; range) records base acceleration at 1000 Hz, with no additional software filtering applied to the recorded data. An Intel RealSense D435 camera on a fixed tripod tracks a tool-mounted ArUco marker to measure tool motion (Figure 3c).
Manufacturer's specification: no-load speeds of approximately 7,000 and 13,000 min and orbital stroke rates of 14,000 and 26,000 min , respectively.
4.3 Force Controller
A task-space admittance controller converts normal-force error into end-effector velocity while maintaining tangential position. Cartesian commands are resolved to joint velocities using a quadratic programme [Haviland et al., 2022].
4.4 Task and Trials
The controller regulates normal force against the wall while holding a fixed tangential target relative to the base. Normal end-effector motion is commanded relative to the base, so motion of the base relative to the wall changes the resulting tool-workpiece displacement. The TCP error is estimated from the tool-mounted marker, tracked by the fixed camera, as its displacement from a reference position (Section 4.5). It is therefore measured relative to the workpiece, whereas the tangential target is held relative to the base; base motion thus enters the TCP error even when the arm tracks its own command.
The trials are organised into three experiments, summarised in Table 2. Experiment 1, on the cart, varies the base-ground resistance, arm posture, and commanded force in single-condition trials (T1–T4). Experiment 2, also on the cart, switches from low to high resistance part-way through contact at two tool speeds (T5, T6), providing a within-trial comparison of the two resistance conditions while tracking TCP error with the camera. Experiment 3 examines whether the same effects are observed on a lighter and more compliant platform. The trolley is lighter than the cart and is placed on foam to introduce additional support compliance. T7 and T8 repeat the low- and high-resistance conditions at high tool speed. A separate hard-floor and foam comparison at low resistance, high tool speed, and a 20 N command examines the effect of support compliance.
Table 2 lists the experimental conditions: low or high base-ground resistance, standard or low arm posture, two tool speeds, and force commands of or . The standard posture places the tool higher and farther from the base, while the low posture places it closer to the deck, reducing the moment arm of the contact force

(a) Cart (UR10)

(b) Trolley (UR5) on foam

(c) Sensors
Figure 3: Physical testbeds. The cart has an aluminium-extrusion frame with a slotted aluminium deck; the trolley has a plywood deck with the compliant layer beneath the base. Panel (c) shows the force/torque sensor, deck-mounted inertial measurement unit, tripod-mounted camera, and tool-mounted ArUco marker used with the trolley; the same sensors were deployed on the cart.
| ID | Condition | Result | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Resistance | Posture | Speed | (N) | (N) | (N) | (N) | Slope (Ns) | (mm) | (ms) med. | max | ||
| Experiment 1 (cart) | ||||||||||||
| T1 | Low | Standard | Low | 100 | 58.8 | 0.59 | 41.5 | 2.6 | 0.42 | n/a | 0.19 | 0.69 |
| T2 | Low | Low | Low | 100 | 68.3 | 0.68 | 32.1 | 3.7 | 0.32 | n/a | 0.08 | 0.12 |
| T3 | High | Standard | Low | 100 | 94.3 | 0.94 | 6.9 | 3.2 | 0.21 | n/a | 0.29 | 0.77 |
| T4 | Low | Low | Low | 25 | 26.3 | 1.05 | 1.9 | 1.3 | -0.04 | n/a | 0.06 | 0.11 |
| Experiment 2 (cart) | ||||||||||||
| T5 | Low | Low | Low | 100 | 58.5 | 0.58 | 41.6 | 3.3 | 0.06 | 98 | 0.10 | 0.17 |
| High from 45 s | 88.3 | 0.88 | 14.1 | 6.9 | 0.77 | 1 | 0.44 | 0.92 | ||||
| T6 | Low | Low | High | 100 | 69.7 | 0.70 | 30.6 | 3.5 | 0.26 | 103 | 0.35 | 0.51 |
| High from 39 s | 100.8 | 1.01 | 7.7 | 6.1 | 0.75 | 1 | 3.9 | 5.9 | ||||
| Experiment 3 (trolley on foam) | ||||||||||||
| T7 | Low | Low | High | 100 | 53.7 | 0.54 | 47.2 | 4.0 | 0.77 | 96 | 18.5 | 23.4 |
| T8 | High | Low | High | 100 | 94.4 | 0.94 | 9.9 | 7.3 | 0.35 | 1 | 24.0 | 28.4 |
Table 2: Trials by experiment, with force realisation, tool centre point (TCP) error, and base vibration during contact, using the metrics defined in Section 4.5.
about the base. In each experiment, base vibration was also recorded with the sander running out of contact, as a reference for the base response to tool operation without workpiece contact. Each trial was performed once, so the results are treated as a case series with comparisons across conditions and experiments.
4.5 Evaluation Metrics
The realised force ratio is the mean normal force divided by the commanded force . Force error is the root-mean-square deviation from the command. Force variation is the standard deviation of the force after subtracting a least-squares linear fit over the evaluation interval, while the slope of that fit is reported separately as force creep. All metrics are computed over steady contact, excluding the transients at contact onset, at the resistance switch, and at retraction; for T5 and T6, the low- and high-resistance phases are evaluated separately.
Base vibration is the peak-to-peak acceleration normal to the deck over 1 s intervals, summarised by its median and maximum. Base vibration is compared within each experiment. TCP error is the magnitude of the tool-marker displacement over the evaluation interval (Section 4.4); for the high-resistance phases of T5 and T6 it is therefore the displacement added after the switch, whereas the figures show the displacement accumulated from the start of the record.
5 Results
The trials revealed persistent force shortfall and tool motion at low base-ground resistance, both of which changed when the resistance was increased during contact. Experiment 2 (Figure 5) shows this sequence within single trials. Base vibration varied with the tool, support, and contact conditions.

(a) Low resistance, standard posture,
(b) Low resistance, low posture,
(c) High resistance, standard posture,
(d) Low resistance, low posture,
Figure 4: Experiment 1: single-condition trials, each shown during contact up to retraction. Top: measured normal force and command. Bottom: base acceleration envelope normal to the deck. In each row, (a)–(d) share the vertical axis.
5.1 Force Shortfall and TCP Motion at Low Resistance
At a 100 N command, all low-resistance trials realised only 54–70% of the commanded force (Table 2). The shortfall persisted through steady contact. In T1, force rose to about 50 N and then crept upwards at 0.4 N s , giving a realised force of 58.8 N and a force error of 41.5 N (Figure 4a). Force variation was 2.6 N, indicating that the principal departure from the command was a sustained force shortfall rather than large fluctuations around the target.
On the second platform, T7 realised 54% of the command and accumulated 96 mm of TCP error (Figure 6a). The error initially grew at 2.9 mm s before slowing, while force continued to rise, with a force creep of 0.8 N s .
Experiment 2 shows the same combination within single trials (Figure 5). In the low-resistance phases of T5 and T6, the realised force ratios were 0.58 and 0.70, while TCP error accumulated to 98 and 103 mm at 2.8–3.1 mm s with the tangential target fixed relative to the base. Sustained contact with relatively low short-term force variation, 3.3 and 3.5 N, thus coexisted with continued tool motion across the workpiece, until the resistance was increased part-way through contact.
5.2 Response to Increased Base Resistance
The within-trial switches in Experiment 2 provide the most direct comparison of the two resistance conditions. In T5 and T6, resistance was increased at 45 s and 39 s, respectively, while the force command remained at 100 N. TCP-error growth was arrested within about 1 s, with only about 1 mm of additional displacement over each high-resistance evaluation interval. Force rose towards the command over about 5 s, giving realised force ratios of 0.88 and 1.01.
Force error fell from 41.6 to 14.1 N in T5 and from 30.6 to 7.7 N in T6, reductions of 66% and 75%. Force variation increased from 3.3 to 6.9 N and from 3.5 to 6.1 N, respectively, and force creep was 0.75–0.77 N s . The substantially lower force error indicates that overall force tracking improved at both tool speeds.
The single-condition comparisons showed the same direction of change. From T1 to T3, the realised force ratio increased from 0.59 to 0.94 and force error decreased from 41.5 to 6.9 N (Figure 4c). From T7 to T8, the realised force ratio increased from 0.54 to 0.94 and force error decreased from 47.2 to 9.9 N; T8 also showed about 1 mm of TCP error (Figure 6b). The same direction of change was therefore observed in the within-trial switches, in the separate trials, and on both platforms.
5.3 Dependence on Posture and Commanded Force
Changing from the standard to the low posture reduced the force shortfall at low resistance. From T1 to T2, the realised force ratio rose from 0.59 to 0.68 and force error fell from 41.5 to 32.1 N (Figure 4a,b). Force still crept upwards at 0.3 N s in T2 and remained well below the 100 N command. The posture change altered the response without removing the sustained force shortfall.
The commanded-force comparison showed a larger change. T4 differed from T2 only in the commanded force, reduced from 100 to 25 N. At 25 N, the realised force was 26.3 N, force error was 1.9 N, and force variation was 1.3 N, with negligible force creep (Figure 4d). The low-resistance condition therefore produced substantially different force-tracking behaviour at the two loads: a persistent force shortfall at 100 N and close tracking at 25 N.

(a) Low tool speed
(b) High tool speed
Figure 5: Experiment 2: switch from low to high resistance part-way through contact. The bar above each panel marks the low-resistance (shaded) and high-resistance phases; the dotted line marks the switch. Top: normal force. Middle: TCP error, the displacement of the tool marker from its position at the start of the record, tracked by the fixed camera. Bottom: base acceleration envelope normal to the deck. In each row, (a) and (b) share the vertical axis.
| Aspect | Simulation | Hardware observations |
|---|---|---|
| Base motion | Slip when the required wheel-ground tangential forces exceed the available traction | About 100 mm TCP error at low resistance (T5–T7), accompanied by of 0.54–0.70 (T1, T2, T5–T7), on both platforms |
| Posture sensitivity | Extended posture increases excitation and reduces the stability margin | Low posture reduced median base vibration from 0.19 to 0.08 m s and raised from 0.59 to 0.68 (T1, T2) |
| Base-ground interaction | Higher wheel friction suppresses slip | High resistance raised to 0.88–1.01 on both platforms (T3, T5, T6, T8); the switch arrested TCP-error growth within about 1 s (T5, T6) |
| Oscillation / tool excitation | Tool excitation produced tool and base oscillation; tool speed shifted the dominant frequency | High tool speed produced substantially higher base vibration than low tool speed, both out of contact and at high resistance (T5, T6) |
| Support compliance | Not represented in the rigid-wheel model | Foam nearly tripled median base vibration relative to the hard floor (Figure 7) |
| Loss of stability | Occurred when the zero-moment point moved outside the support polygon | Not reached |
Table 3: Qualitative comparison of simulated behaviours and hardware observations.
5.4 Vibration Across Tool and Support Conditions
Median base vibration increased in every low-to-high resistance comparison: from 0.19 to 0.29 ms in T1/T3, 0.10 to 0.44 ms in T5, 0.35 to 3.9 ms in T6, and 18.5 to 24.0 ms in T7/T8. These increases accompanied higher realised forces and lower force errors. The vibration also evolved during contact: T1 developed pronounced bursts near the end despite its lower median vi- bration, while in T7 vibration increased as the force rose and TCP motion slowed.
Tool speed produced a pronounced difference in Experiment 2. With the sander running out of contact, median base vibration was approximately 0.03 ms at low tool speed and 1.7 ms at high tool speed. During high-resistance contact, the corresponding values were 0.44 and 3.9 ms. Despite this nearly ninefold difference, force variation was slightly lower at high tool

(a) Low resistance
(b) High resistance
Figure 6: Experiment 3. Top: normal force. Middle: TCP error, the displacement of the tool marker from its position at the start of the record. Bottom: base acceleration envelope normal to the deck. In each row, (a) and (b) share the vertical axis.
speed, at 6.1 N compared with 6.9 N at low tool speed. Larger base vibration therefore did not correspond to larger force variation in this comparison.
Posture and support also changed the vibration response. Lowering the arm from T1 to T2 reduced median base vibration from 0.19 to 0.08 m s while the realised force increased. At the lower load in T4, median base vibration was 0.06 m s , below the 0.13 m s measured with the sander running out of contact in Experiment 1. In the separate support comparison in Experiment 3, at low resistance and a 20 N command, median base vibration increased from 16 m s on the hard floor to 42 m s on foam (Figure 7).
Contact loading could also reduce vibration. In Experiment 3, median base vibration was approximately with the sander running out of contact, falling to 18.5 and during contact in T7 and T8. Together, these observations show a dynamic response that depends on tool excitation, support, and contact state, and does not vary consistently with force error or force variation.
5.5 Relation to the Simulation
Table 3 compares the simulated behaviours with the hardware observations. Both studies showed sensitivity to base-ground interaction and arm posture. Tool excitation produced oscillatory responses in simulation, while tool speed strongly affected base vibration in hardware. The hard-floor and foam comparison additionally exposed a dependence on support compliance, which the rigid-wheel model does not represent. Loss of stability was not observed in the physical trials. In simulation, this behaviour occurred under more adverse combina-

(a) Hard floor
(b) Foam layer
Figure 7: Experiment 3, support comparison (low resistance, 20 N command): base acceleration envelope normal to the deck.
tions of base and loading parameters than those used in the physical experiments. These conditions were not deliberately reproduced on hardware for safety reasons.
6 Discussion
The central observation is that sustained contact did not guarantee that the commanded force was realised or that the intended tool position relative to the workpiece was maintained. Under the 100 N command at low resistance, contact was maintained throughout while the realised force remained well below the command and the tool moved about 100 mm across the workpiece. The within-trial resistance changes provide the clearest link between base-ground resistance and contact execution: with the force command unchanged, TCP-error growth was arrested and realised force increased. The same direction of change was observed on the second platform.
The simultaneous force shortfall and TCP motion, and their response to increased resistance, are consistent with base motion absorbing part of the commanded tool ad-vance, as outlined in the Introduction. Lowering the arm changes the contact-force moment about the wheel contacts, while reducing the commanded load changes the reaction that the support must sustain. The posture and load comparisons show how these task conditions affect the expression of non-rigid base effects.
Vibration characterises another part of the response. Tool excitation is evident even out of contact, and the hard-floor and foam comparison shows the influence of support conditions. The reduction in vibration when the pad was loaded in Experiment 3 is consistent with contact changing how excitation is transmitted through the tool, arm, base, and support. The T1 end-of-contact bursts also show that vibration can evolve substantially within one resistance condition. The improved force tracking at high resistance, despite increased vibration, illustrates how these measurements describe different aspects of contact.
The three measurements consequently serve complementary purposes. Force quantifies how closely the contact load follows the command; the tool marker reveals continued tool motion relative to the workpiece even when the contact force appears to have plateaued; and base vibration describes the response to tool excitation and support conditions. Their joint measurement makes the consequences of non-rigid base behaviour visible beyond a single tracking metric. The simulation supplies a qualitative framework for base motion, oscillation, and loss of stability, while the hardware comparisons reveal compliance-related responses that are not represented by the rigid-wheel model.
The scope of these conclusions is bounded by the case-series design. Each condition was run once, with the principal force and motion responses observed on two platforms. The measured tool motion includes contributions from manipulator tracking error, arm deflection, and base motion. Realised force and arm configuration also changed across the resistance conditions, so their contributions to the observed vibration cannot be separated from the effect of increased base-ground resistance. All contact trials used the operating sander, leaving tool and controller contributions to force variation unresolved. Surface finish and material removal were not assessed, so vibration amplitude is not established as a measure of process quality. The two platforms and support conditions cover only a limited range of lightweight mobile manipulator configurations.
7 Conclusion and Future Work
This sanding case study characterised non-rigid base effects during contact tasks on two lightweight wheeled manipulation testbeds. At low base-ground resistance, a 100 N command produced persistent force shortfall, with only 54–70% realised and TCP errors of about 100 mm in the camera-tracked trials. In the within-trial comparisons, increasing resistance during contact arrested further TCP-error growth within about 1 s and raised the average realised force to 88–101% of the command during the high-resistance phases. Separate low- and high-resistance trials on the second platform showed the same direction of change. The magnitude of the force shortfall depended on posture and commanded force: the low posture reduced it, while a 25 N command was closely tracked at low resistance. Base vibration showed a distinct dependence on tool excitation, support, and contact loading. The exploratory simulation provided a qualitative framework for base motion, oscillation, and stability, while the hardware exposed compliance-related responses not represented by the rigid-wheel model. Together, these results characterise non-rigid base effects through force realisation, tool motion, and dynamic response.
Future work should examine commanded force, posture, and support conditions independently, repeat the comparisons across a wider range of platforms, and relate the measured dynamic response to surface finish and material removal. Experiments on actuated mobile robots should also evaluate coordinated wheel-motor and arm commands to compensate for measured base motion while maintaining contact force. Their effectiveness would need to be assessed against available wheel traction and base stability. These studies would help define feasible contact conditions for mobile manipulators operating with non-rigid base-environment support.
Acknowledgments
This work was supported by the Australian Research Council under Grant No. IC200100001. The authors would like to acknowledge the support of Queensland University of Technology (QUT), the Australian Robotics Centre (ACC), and the QUT Centre for Robotics (QCR). The authors further thank the Advanced Robotics for Manufacturing Hub (ARM Hub) for providing access to the experimental facilities.
References
[Asada and Goldfine, 1985] H. Asada and N. Goldfine. Optimal compliance design for grinding robot tool holders. In Proceedings. 1985 IEEE International Conference on Robotics and Automation, volume 2, pages 316–322, March 1985.
[Bostelman and Hong, 2017] R. V. Bostelman and T. H. Hong. Mobile manipulator stability measurements. Technical Report NIST Technical Note 1955, National Institute of Standards and Technology, 2017.
[Dimo et al., 2001] H. O. Dimo et al. Vibration control of a redundant robot for grinding. In 2001 IEEE In-ternational Conference on Systems, Man and Cybernetics. e-Systems and e-Man for Cybernetics in Cyberspace, volume 1, pages 389–394, Oct 2001.
[Galicki, 2023] M. Galicki. Finite-time control of mobile manipulators subject to unknown/unstructured external disturbances. International Journal of Robust and Nonlinear Control, 33(3):1930–1956, 2023.
[Gao et al., 2026] S. Gao et al. Motion-force control of mobile manipulators via extended uncertainty and disturbance estimation. Control Engineering Practice, 167:106650, 2026.
[Garnier et al., 2018] S. Garnier et al. Mobile robot stability for complex tasks in naval industries. Procedia CIRP, 72:297–302, 2018. 51st CIRP Conference on Manufacturing Systems.
[Haviland et al., 2022] J. Haviland, N. Sünderhauf, and P. Corke. A holistic approach to reactive mobile manipulation. IEEE Robotics and Automation Letters, 7(2):3122–3129, April 2022.
[Li et al., 2024] D. Li, J. Yang, and H. Ding. Process optimization of robotic grinding to guarantee material removal accuracy and surface quality simultaneously. Journal of Manufacturing Science and Engineering, 146(5):051005, 1 May 2024.
[Li et al., 2026] Y. Li et al. State-of-the-art in mobile robot-assisted grinding technologies for large-scale complex components. Robotics and Computer-Integrated Manufacturing, 101:103297, 2026.
[Luo et al., 2014] B. Luo et al. Analysis of sanding parameters, sanding force, normal force, power consumption, and surface roughness in sanding wood-based panels. BioResources, 9(4):7494–7503, 27 October 2014.
[Möller et al., 2017] C. Möller et al. Machining of large scaled CFRP-parts with mobile CNC-based robotic system in aerospace industry. Procedia Manufacturing, 14:17–29, 2017. 17th Machining Innovations Conference for Aerospace Industry, MIC 2017, 6-7 December 2017, Garbsen, Germany.
[Papadopoulos and Rey, 1996] E. G. Papadopoulos and D. A. Rey. A new measure of tipover stability margin for mobile manipulators. In Proceedings of the 1996 IEEE International Conference on Robotics and Automation, volume 4, pages 3111–3116, 1996.
[Petrović and Mattila, 2022] G. R. Petrović and J. Mattila. Analytic solutions for wheeled mobile manipulator supporting forces. IEEE Access, 10:43235–43255, 2022.
[Siciliano and Villani, 1999] B. Siciliano and L. Villani. Robot Force Control, volume 540 of The Kluwer Inter-
national Series in Engineering and Computer Science. Kluwer Academic Publishers, Boston, MA, 1999.
[Tao et al., 2019] B. Tao, X. Zhao, and H. Ding. Mobile-robotic machining for large complex components: A review study. Science China Technological Sciences, 62(8):1388–1400, 1 August 2019.
[Todorov et al., 2012] E. Todorov, T. Erez, and Y. Tassa. MuJoCo: A physics engine for model-based control. In 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems, pages 5026–5033, 2012.
[Torrance, 1990] A. A. Torrance. The correlation of process parameters in grinding. Wear, 139(2):383–401, 1990.
[Wang and Carmichael, 2024] Z. Wang and M. G. Carmichael. Exploring the effect of base compliance on physical human-robot collaboration. In 2024 IEEE International Conference on Robotics and Automation (ICRA), pages 3198–3204. IEEE, 13 May 2024.
[Wang et al., 2021] Q. Wang et al. Force control-based vibration suppression in robotic grinding of large thin-wall shells. Robotics and Computer-Integrated Manufacturing, 67:102031, 2021.
[Yang et al., 2024] Z. Yang et al. Optimal configuration for mobile robotic grinding of large complex components based on redundant parameters. IEEE Transactions on Industrial Electronics, 71(8):9287–9296, August 2024.
[Zhang et al., 2006] X. Zhang, K. Kneupner, and B. Kuhlenkötter. A new force distribution calculation model for high-quality production processes. The International Journal of Advanced Manufacturing Technology, 27(7–8):726–732, 2006.
[Zhao et al., 2020] W. Zhao, J. Peña Queralta, and T. Westerlund. Sim-to-real transfer in deep reinforcement learning for robotics: A survey. In 2020 IEEE Symposium Series on Computational Intelligence (SSCI), pages 737–744, 2020.
[Zhao et al., 2021] X. Zhao et al. Accuracy analysis in mobile robot machining of large-scale workpiece. Robotics and Computer-Integrated Manufacturing, 71:102153, 2021.
[Zhao et al., 2022] X. Zhao, B. Tao, and H. Ding. Multimobile robot cluster system for robot machining of large-scale workpieces. IEEE/ASME Transactions on Mechatronics, 27(1):561–571, Feb 2022.
[Zhao et al., 2023] X. Zhao et al. Vision-based mobile robotic grinding for large-scale workpiece and its accuracy analysis. IEEE/ASME Transactions on Mechatronics, 28(2):895–906, April 2023.