arXiv:2610.36892eess.ASOct 2026

Manuscript Offprint

arXiv:2610.36892

Perceptual Differences and Preferences in Speech Enhancement

Simon Dahl Jepsen, Jesper Rindom Jensen

ABSTRACT

Speech enhancement (SE) systems are commonly evaluated with objective metrics, with and without references, and with categorical subjective listening tests, all measuring speech quality and intelligibility. So far, it is unclear from such evaluations whether the processed speech is perceptually different or is preferred by everyday listeners. We investigate discrimination and preference as complementary dimensions of SE evaluation through crowdsourced triangle and pairwise preference tests across four SE systems, with comparisons to clean references. Results show that both listeners' ability to distinguish and whether they exhibit systematic preference vary across systems and substantially across acoustic conditions. Pairwise evaluations of objective metrics showed variable correlation with both discriminability and preference, motivating further studies into these novel aspects in speech enhancement evaluation.

Index Terms— Speech Enhancement, Comparative Evaluation, Subjective Listening, Discrimination, Preference

1. INTRODUCTION

Distinguishing speech from noise in recordings from authentic environments is a fundamental problem in spoken language processing. This challenging inverse problem has long-standing traditions in statistical signal processing, estimating speech and noise model parameters to infer clean speech from noisy observations [1,2]. The paradigm has now transitioned to learning-based studies with multiple underlying methods, which are generally categorised into discriminative [3,4] and generative [5,6] approaches. However, the goal remains the same: infer clean speech from noisy observations.

The "gold standard" for evaluating perceptual quality of speech enhancement is human listening tests, with established ITU-T p.800 methods including absolute (ACR), degradation (DCR), and comparative (CCR) categorical quality assessment [7–9]. ACR and DCR are rated on a five-point scale. CCR is rated on a seven-point scale. Results are reported as mean opinion-score (MOS, DMOS, and CMOS, respectively) [7]. ITU-T P. 808 specifies how to crowd-source these experiments [9]. The ITU-T P.835 standard prescribes a method for conducting subjective evaluation of speech enhancement methods, using ACR; it asks listeners to rate the enhanced speech, attending to the speech signal, background, and overall quality, respectively [8]. Because subjective evaluation is expensive, SE benchmarks also rely heavily on objective measures of signal fidelity, intelligibility, and perceptual quality. Popular examples include SI-SDR [10], STOI [11] and ESTOI [12], composite predictors of the P.835 quality dimensions [13], and PESQ [14]. These measures are all intrusive, requiring access to a clean reference signal, which is generally unavailable for real-world recordings. This has motivated the development of non-intrusive speech-quality measures [15–20], which estimate perceptual quality directly from the observed signal. In parallel, reference-free models such as SQUIM [21] estimate established objective measures, including STOI, PESQ, and SI-SDR, without access to the corresponding clean speech signal.

SE benchmarks are commonly summarised by corpus-level means or medians of objective or subjective scores, with differences between systems interpreted as evidence of improved performance. However, differences on these scales show separation according to that measure, but do not necessarily mean listeners can distinguish the related signals. Furthermore, it is unclear if metric separation or distinguishability corresponds to a systematic preference from everyday listeners. These distinction become important as high-performing SE systems achieve increasingly similar scores on selected benchmarks. The URGENT challenges [22] results have highlighted discrepancies between objective and subjective SE evaluation [22], while recent work has moved toward comparative evaluation, including pairwise objective quality assessment [23,24]. ITU-T P.800 and P.808 already describe pairwise evaluation with CCR, in which listeners jointly indicate the direction and magnitude of a perceived quality difference on a seven-point scale [7,9]. However, the magnitude of such differences may become small for high-performing SE systems, as recent CCR evaluations also observe [22].

This work introduces discriminability and preference as complementary dimensions to SE evaluation. First, an evaluation framework is adopted that evaluates these new dimensions through subjective listening tests. Second, a crowdsourced evaluation of four high-performing contemporary SE systems is conducted, characterising discrimination and preference across system-pairs and speech material. Finally, it is investigated whether difference scores of a range of objective metrics can predict these new SE dimensions. The web-based listening-test framework and experimental material are made publicly available to facilitate reproducible evaluation of future SE systems 1^{1}.

References (33)