Manuscript Offprint

arXiv:2610.37374

Comparing Temporal Deep Learning Architectures for Discrete Cross-User Myoelectric Control

Ethan Eddy, Evan Campbell, Scott Bateman, Erik Scheme

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Ethan Eddy*, Evan Campbell*, Scott Bateman†, Erik Scheme*

*Department of Electrical Engineering, University of New Brunswick, Canada

†Faculty of Computer Science, University of New Brunswick, Canada

Abstract—The recognition of dynamic gestures via discrete myoelectric control is becoming an attractive input modality for event-based human-machine interaction. While recent work suggests that discrete cross-user models are possible (i.e., no calibration data is required from the end user), few have evaluated techniques to optimize these systems and their generalizability to new randomly prompted data simulating real-world discrete control is relatively unknown. Using the 612-user EMG-EPN dataset, this work benchmarks five temporal deep-learning approaches, evaluates the tradeoff between performance and model complexity, and compares hand-crafted and machine-learned feature extraction techniques. The CNN-GRU achieved the best accuracy of 93% when tested on 184 previously unseen users. These models were then evaluated on a different, more realistic, unsegmented dataset, wherein users were randomly prompted to elicit discrete gestures during a continuous data collection. This dataset was recorded five years apart and in a separate country from the data used to train the original model. Results show that the cross-user results scale to this new dataset (accuracies of 96%) even though no feedback was given to users during the elicitation of gestures. These findings highlight the exciting potential of discrete zero-shot cross-user myoelectric control and offer valuable insights for the continued advancement of this promising technology.

Index Terms—Cross-User, Deep Learning, Electromyography, Gesture Recognition, Myoelectric Control, Zero-Shot

I. INTRODUCTION

As human-machine interaction (HMI) continues to expand beyond conventional computing environments, the need is arising for new enabling technologies to replace traditional inputs. Leveraging the physiological electromyogram (EMG) signal, the electrical potentials generated by muscles when they are contracted, myoelectric control is one possibility for these emerging use-cases [1]. However, despite its promise and history of success in controlling powered prostheses, the widespread use of this technology for HMI has largely been hindered by the need for regular and personalized end-user calibration [2].

Compared to the traditional use case of continuous myoelectric control, whereby decisions are made on small windows of data [3], discrete control maps dynamic gestures (e.g., a double tap or finger snap) to event-based commands [2]. Although developing true cross-user models that require no training data from the end user is challenging for continuous control, recent work is beginning to show that the temporal structure of dynamic gestures may help overcome this challenge [1], [4]. Moreover, discrete control might even be more appropriate for HMI as many inputs, such as button clicks and swipes, are inherently event-based [2], [5], [6].

Although previous work has demonstrated the feasibility of cross-user discrete control without recalibration [1], [4], little work has evaluated techniques and approaches to optimize these systems. This work correspondingly benchmarks five temporal deep learning architectures and compares handcrafted feature extraction to machine-learned CNN-based approaches on the 612-user EMG-EPN dataset [7]. Additionally, to test the real-world performance and generalizability of these models, a never released dataset with 14 participants was used, where users were randomly prompted to elicit discrete gestures during a continuous data collection. This required that these gestures be detected and segmented from the continuous input stream, which is often ignored in offline studies. The results suggest, for the first time, that even under these real-world settings (i.e., data collected years apart, in a different country, and in the context of randomly prompted gestures), classification accuracies can reach up to 96% on data from unseen users. These results provide valuable insights for the future development of discrete cross-user myoelectric control systems and further highlight the potential viability of this promising technology.

References (17)

  • A generic noninvasive neuromotor interface for human-computer interaction
  • A framework and call to action for the future development of emg-based input in hci
  • A robust, real-time control scheme for multifunction myoelectric control
  • Big data in myoelectric control: large multi-user models enable robust zero-shot emg-based discrete gesture recognition
  • Muscle activity mapping by single peak localization from hdsemg
  • Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces
  • Emg-epn-612 dataset
  • Understanding the influence of confounding factors in myoelectric control for discrete gesture recognition
  • Evaluation of the myo armband for the classification of hand motions
  • A comparison of emg-based hand gesture recognition systems based on supervised and reinforcement learning
  • Driver drowsiness classification using fuzzy wavelet-packet-based feature-extraction algorithm
  • Adam: A Method for Stochastic Optimization
  • PyTorch: An Imperative Style, High-Performance Deep Learning Library
  • Libemg: an open source library to facilitate the exploration of myoelectric control
  • The virtual trackpad: An electromyography-based, wireless, real-time, low-power, embedded hand-gesture-recognition system using an event-driven artificial neural network
  • Pattern recognition of number gestures based on a wireless surface emg system
  • Teager-kaiser operator improves the accuracy of emg onset detection independent of signal-to-noise ratio