arXiv:2610.35357cs.CVOct 2026

Manuscript Offprint

arXiv:2610.35357

Evidence-Guided Selection of Retinal Vessel Segmentation Pipelines: A Cross-Dataset Benchmark of Performance, Structure, Failure Modes, and Reproducibility

Ruoyu Yan, Yuejia Liu, Shixin Xu, Xiaoyan Li, Xi Luo, Yuhui Deng, Huaxiong Huang

Abstract

Retinal vessel segmentation is widely used in retinal image analysis, yet model selection based only on aggregate overlap scores can overlook structural fidelity, cross-dataset robustness, and application-specific error costs. We evaluated five executable binary vessel-segmentation pipelines—FSG-Net, SA-UNetv2, DCP-1024, GAVE, and FR-UNet—on 244 images from six public datasets using pixel-level agreement, cross-dataset stability, thin-vessel retention, structural metrics, error composition, and available computational evidence. Results were aggregated with equal weighting across datasets. No pipeline was optimal in every setting. FSG-Net achieved the highest equal-dataset mean Macro-F1 (0.77), IoU (0.63), clDice (0.83), and Skeleton F1 (0.78), whereas SA-UNetv2 achieved the highest mean sensitivity (0.85) and Thin-Vessel Sensitivity (0.63). Differences across datasets were often larger than those among the leading pipelines, and errors shared by all five methods were concentrated near annotated vessel boundaries and faint peripheral vessels. In an ancillary analysis on 45 HRF images, segmentation masks were converted into 11 ring-wise vascular features for leave-one-out classification. Controlled perturbations showed that local mask errors

*Corresponding author. Email: huaxiong.huang@dukekunshan.edu.cn can be amplified in downstream features, while targeted stabilization reduced sensitivity for five features. The results support task-conditioned, benchmark-relative pipeline selection rather than a single universal ranking and highlight the need to validate the selected pipeline on the intended target domain.

Keywords: Retinal vessel segmentation; Cross-dataset benchmark; Topology-aware evaluation; Thin-vessel analysis; model selection; Reproducibility

1 Introduction

Background and Model-Selection Context Retinal vessel segmentation is a foundational component of computational fundus-image analysis, supporting vascular classification and other computer-aided retinal analyses. Reliable segmentation remains difficult because vessels occupy only a small fraction of the field of view. Variations in resolution, contrast, illumination, acquisition conditions, and pathology can also further alter vascular visibility and apparent morphology. These challenges can produce different residual errors, including missed vessels, false-positive responses, boundary shifts, and vessel-width errors. Because pipelines may differ in their ability to recover small branches, suppress false positives, or maintain connectivity, no single pipeline should be expected to perform best across all criteria [5, 7, 15, 19, 26]. Figure 1.1 presents several representative HRF images and predictions from FSG-Net and SA-UNetv2. These results often do not reveal all the differences among different methods and their impact on downstream applications. For example, some tasks prioritize overall agreement, whereas others may require better thin-vessel recovery or structural preservation. A pipeline preferred under one objective may be unsuitable under another. Retinal vessel segmentation is therefore framed as a task-conditioned pipeline-selection problem.

Existing Evaluation and Review Gaps and Motivation Conventional model comparisons often emphasize pixel-level performance. However, these metrics may ignore structurally important errors, including vessel disconnections and centerline inconsistencies [28].

Previous reviews have summarized retinal vessel segmentation methods, datasets, preprocessing, evaluation metrics, generalization, and clinical applications [2,5,15,23,26]. However, direct comparison across studies remains difficult because of differences in datasets, preprocessing, thresholds, implementations, and evaluation protocols. For example, recent CMPB fundus-vessel studies evaluated overlapping benchmark datasets under method-specific preprocessing and operating thresholds [8]. Reported metric sets also differ across studies; for example, DilUnet emphasizes Accuracy, Sensitivity, and IoU on DRIVE, STARE, and CHASE [12]. Cross-dataset studies have also shown substantial performance degradation under domain shift [7]. This evidence has not yet been translated into practical pipeline-selection guidance tailored to different segmentation requirements.

Original fundus image

GT vessel mask

FSG-Net vessel mask

SAUNet vessel mask

Figure

Representative HRF examples; masks show binary overall-vessel segmentation.

Figure 1.1: Representative HRF fundus images and pixel-level vessel segmentation results.

Study Scope and Contributions To address this gap, this study evaluates executable pipelines rather than only comparing literature-reported scores. A shared cross-dataset benchmark combines overall segmentation quality, asymmetric error costs, thin-vessel retention, structural preservation, cross-dataset stability, and computational evidence. These evidence dimensions are aggregated with equal dataset weighting and later used in the decision framework described in Section 5. This benchmark compares executable pipelines under source-compatible operating conditions; its results should not be interpreted as architecture-only effects, because training exposure and implementation provenance differ across pipelines.

As an ancillary analysis, we examine how segmentation differences propagate into ring-wise vascular features and downstream HRF classification. The experiment traces the transformation from vessel masks to interpretable centerline-, caliber-, and graph-based features and evaluates whether targeted feature stabilization reduces sensitivity to local mask errors.

The benchmark covers six evaluation datasets and five executable retinal vessel segmentation pipelines, comprising 244 images and 1,220 per-image predictions across 30 model-dataset combinations. The study is restricted to binary overall-vessel segmentation; artery-vein segmentation is not included because artery-vein reference labels and compatible outputs are not consistently available across the evaluated datasets and pipelines, whereas downstream classification is examined only as an ancillary HRF analysis.

Dataset-level results were aggregated with equal weighting across the six datasets. The same decision policy is implemented in a public browser-based tool for inspecting evidence dimensions, scenario-specific rankings, and application-specific weights. Despite some limitations, our study provides a reproducible starting point for researchers who need to use a segmentation method for their retina image-based applications.

The rest of the paper is organized as follows. In Section 2, we present the selection criteria for the datasets and segmentation pipelines, with more technical details given in Sections 3 and 4. Evidence-guided model selection is presented in Section 5, while the effect of datasets is discussed in Section 6. Section 7 presents a case study of application-oriented evaluation and selection of segmentation models. And Section 8 discusses the study limitations, future directions, and conclusions. Technical details are given in various appendices.

References (33)