arXiv:2610.33118cs.CVOct 2026

Manuscript Offprint

arXiv:2610.33118

The Paired Thermal Channel Is Two Orthogonal Axes: A Controlled Attribution Study of Calibration Cost and Detection Gain in Infrared Person Detection

Tian Zhang, Yang Chen, Bing Bai, Weikai He, Xiang Gao, Zhirong Su

Abstract

The calibrated thermal channel in infrared person detection comprises two structurally orthogonal axes. True calibrated ΔT\Delta T outperforms scale-matched grayscale pseudo- ΔT\Delta T by +0.0221 mAP (paired Wilcoxon p=0.0098p = 0.0098, Cohen's d=+1.08d = +1.08), confirming that the calibrated channel carries information the grayscale channel lacks. The calibration axis is driven by the joint pairing-scale condition. Preserving both paired correspondence and absolute calibrated scale raises expected calibration error (ECE) from ≈0.05\approx 0.05 to 0.142. The 2×22 \times 2 interaction ( p=0.0059p = 0.0059) localizes the rise to this condition. Breaking either factor alone returns ECE to the broken-factor level (true-vs-const p=0.002p = 0.002; true-vs-shuffled p=0.002p = 0.002). Under post-hoc temperature scaling, the pairing cost survives recalibration ( p=0.002p = 0.002), while the scale cost is largely absorbed ( p=0.16p = 0.16). As regards the detection axis, the gain stems from structural de-structuring. Phase randomization, which destroys spatial structure while preserving per-sample variance, yields +0.0185 mAP over true ΔT\Delta T on FLIR ADAS ( p=0.014p = 0.014, d=+0.96d = +0.96). The FLAME 3 gain is +0.0064 mAP ( p=0.078p = 0.078, n=8). On the calibration axis, the same intervention is insignificant on FLIR ADAS ( p=0.47p = 0.47) but significant on FLAME 3 ( p=0.0078p = 0.0078). These findings rest on a five-arm controlled attribution with temperature-evidential learning (TEL) as the testbed. TEL obtains a single evidence-derived routing scalar together with a complementary diagnostic entropy, and establishes a finite-evidence degeneracy theorem proving that the acquisition product degenerates to this scalar with a closed-form bound. A physical 0.5∘0.5^{\circ}C threshold admits cross-dataset physical readings, whereas a gray threshold of 20 inverts without physical interpretation.

Keywords: infrared person detection, evidential deep learning, thermal contrast modulation, paired thermal correspondence, calibration cost, two-axis orthogonality, joint pairing-scale condition, temperature-evidential learning (TEL)

1 Introduction

Pedestrian detection at night or under other low-visibility conditions remains a persistent challenge for thermal infrared perception. Among the sensing modalities that stay reliable under low illumination, thermal infrared is distinguished by its stable response across lighting conditions. The literature has advanced from handcrafted features to end-to-end convolutional detectors, with recent work on multispectral pedestrian detection transformers [1], illumination-aware thermal detection [2], and thermal image enhancement [3]. However, the treatment of radiometric data has remained largely unchanged. A thermal camera outputs a calibrated temperature per pixel. Conventional pipelines convert this into an 8-bit grayscale image or a false-color rendering and then discard the temperature matrix, which carries the physical evidence. When a person wears heavy clothing or stands before a warm surface, the grayscale contrast collapses and the detector loses the target.

The issue intensifies within learning loops. Active learning chooses samples to annotate, pseudo-labeling chooses which predictions to trust, and continual learning chooses which past examples to replay. When only a rendered image is available, all such decisions rely on the same visual features and inherit the same blind spots. Evidential deep learning (EDL) offers a principled framework for uncertainty estimation. It places a Dirichlet prior over class probabilities and gathers evidence in a single forward pass [4, 5]. EDL has been brought into detection [6, 7, 8, 9], and evidence-based fusion has been explored for multispectral pedestrian detection. Yet these methods still treat uncertainty as a purely visual quantity, and the applications of EDL to active learning and pseudo-labeling have progressed on separate tracks. Existing frameworks address annotation, pseudo-labeling, and replay with separate criteria.

We examine what ΔT\Delta T, i.e., the temperature contrast between a target region and its immediate surround, actually is. It is a calibrated physical measurement. Its physiological source is stable across scenes and sensors: human core temperature remains near 310 K, although clothing and background can attenuate the observed surface contrast. ΔT\Delta T is also correlated with the local separability of the target from its background. Among the visual features considered in this work, these three proper-

T. Zhang and B. Bai are with the School of Information Engineering, Shandong Management University, Jinan, China.

Y. Chen is with the School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore (Corresponding author).

X. Gao and W. He are with the School of Aeronautics, Shandong Jiaotong University, Jinan, China.

Z. Su is with the School of Business, Shandong Management University, Jinan, China.

Email: tianzhang@sdnu.edu.cn, chen1605@e.ntu.edu.sg,

bbingsdmu@126.com, 214035@sdjtu.edu.cn, abrahamgx@163.com,

suzhirong007@163.com ties are unique to the calibrated thermal channel. These properties indicate that ΔT\Delta T is a reliable signal for evidence modulation. The resulting uncertainty can then drive annotation, pseudo-labeling, and replay.

This paper presents a structural attribution finding for paired physical channels. The calibrated thermal channel has two components with different causal origins. ECE responds to the joint pairing-scale condition, where the pairing of target and background and the absolute calibrated scale act jointly on it. mAP responds to a different factor, namely how the thermal contrast is injected into the modulation channel, not which spatial thermal pattern the contrast preserves. We establish these two axes through five controlled attribution arms. The true arm retains all five factors. The other three arms each break one of them. Specifically, const- ΔT\Delta T keeps within-image structure but drops the absolute calibrated scale, shuffled- ΔT\Delta T keeps the amplitude but destroys paired correspondence, and var-phase keeps both the power spectrum and the per-sample variance while removing only the spatial phase. The random arm breaks all four factors (pairing, scale, power-spectrum structure, and spatial phase) at once, with the injected variance held matched. The five arms separate the five factors and expose the two axes. These axes are instantiated by the evidence chain in Fig. 1. Retaining the calibrated matrix T enables modulation, which anchors a single cognitive uncertainty u as the routing scalar. TEL implements this chain and serves as the attribution testbed.

The contributions consist of attribution findings and the methodological framework that supports them.

• Pairing-scale joint condition as an operational criterion. A 2×22 \times 2 intervention (true, const- ΔT\Delta T, shuffled- ΔT\Delta T, and random) separates paired correspondence from absolute calibrated scale, and the interaction contrast tests whether the two factors act jointly. Preserving both raises ECE from ≈0.05\approx 0.05 to 0.142 (interaction Wilcoxon p=0.0059p = 0.0059). Breaking either factor in isolation returns it to the broken-factor level (true-vs-const p=0.002p = 0.002 and true-vs-shuffled p=0.002p = 0.002). Post-hoc temperature scaling separates the two factors by how much of their ECE cost a monotone rescaling can remove. The true-vs-shuffled gap survives recalibration ( p=0.002p = 0.002), whereas the true-vs-const gap is absorbed ( p=0.16p = 0.16). The two factors act on the same confidence distribution, and the distinction is one of proportion, not of kind. The criterion is operational, as any calibrated physical channel can be tested with the same four-arm intervention plus a post-hoc recalibration probe, and we validate it on two radiometric benchmarks.

• The calibrated channel carries information. True ΔT\Delta T outperforms scale-matched grayscale pseudo- ΔT\Delta T by +0.0221 mAP (paired Wilcoxon p=0.0098p = 0.0098, d=+1.08d = +1.08), so the calibrated channel carries information the collapsed grayscale channel does not.

• Detection gain tracks structural de-structuring, not spatial thermal structure. Random modulation exceeds true ΔT\Delta T by +0.0341 mAP, and the phase-randomized arm exceeds true ΔT\Delta T by +0.0185 mAP (paired Wilcoxon p=0.014p = 0.014, d=+0.96d = +0.96) while preserving per-sample variance and removing only spatial phase. Flattening the power spectrum accounts for the remaining +0.0156 ( p=0.004p = 0.004). The gain is attributable to the destruction of spatial structure, not to the spatial thermal pattern that calibration preserves. The two axes vary independently. In the cross-dataset contrast, each axis is significant on the dataset where its structural counterpart is most pronounced.

• Deployment value of the retained absolute scale. Physical thresholds expressed in °C remain semantically consistent across datasets. By contrast, a gray threshold of 20 inverts across the same pair and admits no physical reading.

• A modality-agnostic attribution protocol. The five-arm design, 2×22 \times 2 interaction Wilcoxon, and partial-correlation control are defined on a generic calibrated auxiliary channel rather than on temperature specifically. We validate the protocol on two radiometric benchmarks. These two benchmarks span two orders of magnitude in ∣ΔT∣|\Delta T| and differ in the ΔG−ΔT\Delta G-\Delta T Pearson correlation, so the protocol is tested under two structurally different calibrated regimes. The same construction applies to any paired channel that provides a calibrated auxiliary measurement alongside a visual one, such as LiDAR reflectance or radar cross-section.

• A unified routing framework with proved consistency. A single scalar u governs annotation, pseudo-labeling, and discard through one rule. The routing partition is invariant under strictly increasing affine reparametrizations, and the acquisition product degenerates to u in the finite-evidence regime ( R2≥1−ηR^{2} \geq 1 - \eta). We establish the framework and prove it self-consistent.

References (56)