Spectrally optimized implicit neural representations mitigate acquisition-related image quality trade-offs in intracranial 4D Flow MRI

Oliver Welin Odeback, Nerea González-Aranceta, Sebastián Jofre, Javier Bisbal, Edward Ferdian, Alistair A. Young, Pia Callmer, Sameer A. Ansari, Mia Bonini, David Nordsletten, Patrick Winter, Susanne Schnell, Tobias Granberg, Alexander Fyrdahl, David Marlevi

Oliver Welin Odeback1,7∗^{1,7*}, Nerea González-Aranceta1^{1}, Sebastián Jofre1,7^{1,7}, Javier Bisbal2,7^{2,7}, Edward Ferdian3^{3}, Alistair A. Young4^{4}, Pia Callmer1^{1}, Sameer A. Ansari5^{5}, Mia Bonini6^{6}, David Nordsletten6^{6}, Patrick Winter7^{7}, Susanne Schnell7^{7}, Tobias Granberg1,8^{1,8}, Alexander Fyrdahl1,9^{1,9}, David Marlevi1,10^{1,10}

1∗^{1*}Dept. Molecular Medicine and Surgery, Karolinska Institutet, Karolinska Universitetssjukhuset Solna (L1:00), Stockholm, 171 76, Sweden.

2^{2}Biomedical Imaging Center, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Macul, Santiago, 7820436, Chile.

3^{3}School of Electrical Engineering and Informatics, Bandung Institute of Technology, Jl. Ganesha No. 10, Bandung, 40132, West Java, Indonesia.

4^{4}School of Biomedical Engineering & Imaging Sciences, King's College London, 1 Lambeth Palace Rd, South Bank, London, SE1 7EU, UK.

5^{5}Department of Radiology, Neurology, and Neurological Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA.

6^{6}Department of Biomedical Engineering, University of Michigan, 2200 Bonisteel Blvd, 1107 Carl A. Gerstacker Building, Ann Arbor, MI, 48109-2099, USA.

7^{7}Department of Physics, University of Greifswald, Felix-Hausdorff-Str. 6, Greifswald, 174 89, Germany.

8^{8}Department of Neuroradiology, Karolinska University Hospital, Hälsovägen 13, O42, Stockholm, 141 86, Sweden.

9^{9}Department of Clinical Physiology, Karolinska University Hospital, Eugeniavägen 3, A8:01, Solna, 171 64, Sweden.

10^{10}Institute for Medical Engineering and Science, Massachusetts Institute of Technology, 45 Carleton St, Cambridge, 02142, MA, USA.

*Corresponding author(s). E-mail(s): oliver.welin.odeback@ki.se;

Abstract

4D Flow MRI promises unique opportunities for non-invasive mapping of neurovascular hemodynamics, but its clinical utility remains limited by trade-offs between spatiotemporal resolution, acquisition time, and image noise. Deep learning-based super-resolution offers a post-scan solution; however, supervised approaches require paired or domain-specific training data, while patient-specific physics-informed models can be computationally demanding. This creates a need for unsupervised reconstruction models that can adapt to individual acquisitions without paired high-resolution training data, while remaining robust across anatomy, disease severity, and acquisition quality. To address this, we introduce a spectrally tuned implicit neural representation (INR) framework for intracranial 4D Flow MRI, representing the velocity field as a continuous coordinate-based neural field using WIRE activation functions with tunable spectral bias. Data-driven and physics-informed variants were evaluated in nine cerebrovascular cases spanning healthy controls and moderate-to-severe intracranial atherosclerotic disease, using CFD-derived high-resolution reference fields, MR-realistic synthetic low-resolution inputs, and direct fitting to acquired in-vivo data. Cohort-optimal spectral-bias settings generalized across subjects with only small increases in relative error compared with subject-specific optima, reducing the need for case-specific hyperparameter tuning. Physics-informed regularization provided modest additional accuracy but required substantially longer optimization, whereas the data-driven INR achieved near-comparable reconstruction performance within minutes. The framework also remained robust to acquisition-realistic noise and moderate VENC-dependent aliasing. These findings establish spectrally optimized INRs as a flexible unsupervised approach for mitigating acquisition-related trade-offs in intracranial 4D Flow MRI.

Keywords: 4D Flow MRI, Implicit Neural Representations, Physics-Informed Neural Networks, Super-resolution

1 Introduction

Quantitative assessment of cerebrovascular hemodynamics is important for understanding neurological disease mechanisms and characterizing altered flow in disorders such as intracranial stenosis, aneurysms, and arteriovenous malformations [1–3]. In this setting, four-dimensional flow magnetic resonance imaging (4D Flow MRI) holds particular promise through its ability to non-invasively image time-resolved, three-directional velocity data across various cardiovascular compartments [4]. While presented for general intracranial use [5, 6], extension of 4D Flow MRI into a wider range of intracranial applications remains challenging, with small vessels, tortuous anatomies, and stenosis-related flow accelerations putting high demands on spatial resolution, signal-to-noise ratio, and scan duration, while velocity-encoding (VENC) selection introduces an additional trade-off between velocity sensitivity and the risk of phase-wrapping artifacts [7]. As such, while the technique holds unique abilities in non-invasively mapping intracranial hemodynamics, practical compromises are still made in image quality, acquisition time, or effective resolution, each potentially limiting the broader use of the technique for quantifying regional intracranial flow information [8–10].

To address these limitations, post-acquisition reconstruction methods, including deep learning-based approaches, have emerged; all aiming at denoising velocity data, improving effective resolution, and recovering flow features that are poorly resolved at standard clinical data settings [11–13]. Out of numerous approaches, so-called physics-informed neural networks (PINNs) provide a unique way of combining data-driven reconstruction with prior knowledge of the underlying physical system at hand [14], effectively constraining traditional network approaches by fundamental physiological regularization. For 4D Flow MRI, this holds particular promise where measured velocity data are typically noisy or sparsely resolved, but where underlying governing relationships are well-known (the Navier-Stokes equations). Numerous examples also exist showcasing the utility of PINN-based approaches for phase-contrast MRI, recovering both flow and pressure in various settings [15–18].

However, despite their promise, current PINN formulations still face important challenges, not least for intracranial extensions. So far, most presented models have mainly been applied to simplified, large-vessel, or model-dependent settings, limiting direct applicability to acquired in-vivo data. Other presented approaches rely on reduced-dimensional formulations (such as one-dimensional Navier-Stokes models) introducing assumptions that may not hold in the setting of tortuous, multi-bifurcated vascular anatomies. Another current drawback is that most PINNs are optimized to represent a single vascular geometry, requiring explicit retraining for each new subject at hand, severely limiting applicability for wider clinical research use.

As an alternative, so-called implicit neural representations (INRs) - a class of neural networks closely related to PINNs - similarly learn continuous mappings from spatial coordinates to the measured signal [19–21]. However, instead of relying on physics-based regularization, the INR field emphasizes the role of network spectral properties, which can be tuned to control the balance between fine-scale detail recovery and smoothness while still allowing computationally efficient patient-specific optimization. Despite strong results in image super-resolution, view synthesis, and 3D shape reconstruction [22–24], INR-based reconstruction remains largely unexplored in 4D Flow MRI. To date, the main exception is Saitta et al. [25], who demonstrated unsupervised super-resolution and denoising in a localized aortic setting. However, their implementation considered only a single spectral setting, leaving the effect of spectral-bias optimization on reconstruction quality unexplored. Moreover, the potential of INRs for complex cerebrovascular 4D Flow MRI, including stenotic flow, multi-bifurcated anatomy, and generalization across cases, remains unknown.

In this work, we aimed to explore the use of INRs for unsupervised super-resolution of intracranial 4D Flow MRI, focusing in particular on spectral bias optimization to enable robust network performance across various intracranial anatomies. Introducing a state-of-the-art Wavelet Implicit neural REpresentation (WIRE)-based INR reconstruction framework with controllable spectral bias [26], we investigate how this bias influences reconstruction accuracy, show how it can be tuned to balance fine-scale detail recovery against noise, and highlight how optimized bias settings generalize across patient cases. By evaluating two complementary variants - one fast data-driven model and one computationally demanding physics-informed extension - we also map out how physics-based regularization and associated training burden impact the possible utility of INRs in the setting of efficient super-resolution intracranial flow imaging. The main contributions of our work lie in (1) the novel application of spectral-biastuned networks for intracranial 4D Flow MRI, (2) the identification of optimal bias tuning for anatomical generalization, and (3) the demonstration that data-driven INRs achieve near-comparable performance to physics-informed alternatives at a fraction of the required optimization time. In conjunction, these novelties provide a robust framework for continuous, arbitrary-resolution reconstruction of intracranial 4D Flow MRI, using a uniform spectrally optimized INR setup to allow for broader image-based exploration of regional intracranial flow phenomena in the future.