Manuscript Offprint
arXiv:2610.33359Automated screening of Parkinson's Disease using Smooth Pursuit Eye Movements
Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.
Abstract
Smooth pursuit eye movements are frequently altered in Parkinson's disease, but previous studies have relied mainly on conventional parameters that describe the relationship between gaze and target. This study investigates whether complexity and nonlinear dynamics measures of the gaze position sequences can support the automatic screening of Parkinson's disease. Gaze position sequences were recorded with a video eye tracker in 41 participants with early Parkinson's disease and 47 healthy controls during 12 smooth pursuit tasks. Four experimental frameworks and four embedding delay strategies were compared. The selected experimental setting combined baseline wander removal with a fixed embedding delay. After feature selection, a support vector machine was trained for each task and axis and their outputs were combined in a mixture of experts. The pipeline was developed in 70 participants and evaluated on an external test set of 18 participants. On the external test set, the pipeline obtained an area under the receiver operating characteristic curve of 0.86. The most informative features described less persistent and more irregular gaze position sequences in Parkinson's disease, mainly along the horizontal axis. These results support complexity and nonlinear dynamics measures of smooth pursuit as candidate markers for Parkinson's disease screening, pending validation in larger independent cohorts.
Introduction
Parkinson's disease (PD) is a progressive multisystem neurodegenerative disorder characterised mainly by degeneration of dopaminergic neurons in the substantia nigra pars compacta, although several nondopaminergic systems are also affected. It produces motor and nonmotor manifestations, some of which may precede the cardinal motor signs. Among fine motor symptoms, oculomotor alterations are known to occur from the early stages of the disease. In this regard, two-thirds of patients with PD showed oculomotor alterations in an electro-oculographic study [1].
Since eye movements can be recorded quantitatively and noninvasively, they have been investigated as complementary markers of PD [2]. It is known that PD introduces certain deviations in the behaviour of the oculomotor system, affecting fixation, saccades, vergence and Smooth Pursuit Eye Movements (SPEM) [2, 3].
SPEM are continuous eye movements that keep the image of a moving target close to the fovea. Their control involves sensory processing, attention, prediction and executive mechanisms, with coordinated activity across cortical, cerebellar, basal ganglia and brainstem circuits [4]. Pursuit-related activity has also been reported in the substantia nigra pars reticulata, a major output nucleus of the basal ganglia [5]. The involvement of the basal ganglia provides a neurophysiological rationale for investigating SPEM alterations in PD [3].
Consistent with this, abnormal saccades during SPEM have been reported in 43.8% of patients with PD compared with 10.0% of Healthy Controls (HCs) [6]. Therefore, SPEM analysis is considered of clinical interest for evaluating patients with PD [3].
Deviations in the eye’s positions during SPEM are typically corrected by means of saccadic movements. Saccades are rapid eye movements that abruptly redirect the gaze to an object of interest. Although the presence of saccadic movements in SPEM is considered normal, the frequency, extent and type are different in patients with PD [6]. During SPEM, several types of abnormal and involuntary saccadic movements exist in the recorded sequences: catch-up saccades, back-up saccades and square-wave jerks.
Clinical studies in PD have extensively investigated a set of conventional and physiologically interpretable parameters extracted from SPEM recordings. Pursuit gain, defined as the ratio of eye velocity to target velocity, is the most widely studied [3]. Other parameters include pursuit latency, phase lag, position error, eye velocity, range of motion and the number or amplitude of saccades during pursuit [7, 8, 9].
Saccadic activity during pursuit can also describe the tracking behaviour. Corrective saccades reduce the error between gaze and target position. Additionally, catch-up saccades, for example, act when gaze falls behind the target [10]. On the other hand, anticipatory saccades, back-up saccades and other saccadic intrusions arise from different mechanisms and may differ in number, amplitude, timing and direction between participants with PD and HCs [6].
Reduced gain and saccadic or fragmented pursuit are also among the most frequently reported impairments in PD, but findings vary with the stimulus, recording system, medication state and analysis procedure [3]. Newly diagnosed and untreated participants with PD have shown alterations associated in some cases with disease duration and motor severity [11], whereas pursuit can remain relatively preserved under specific task conditions [12]. Recent studies have also reported effects of movement direction, target frequency and medication state, together with alterations in velocity, phase and range of motion in early PD [13, 9]. Pursuit impairment therefore cannot be characterised by gain alone and may depend on the direction, frequency, amplitude, predictability and duration of the target trajectory.
Although the aforementioned characteristics have provided substantial evidence of altered tracking in PD, they mainly describe very specific aspects of the relationship between gaze and the target, not taking the temporal organisation and dynamics of the signal into account. On the other hand, a common assumption in biosignal processing is that the presence of a disease can alter the organisation and adaptability of biological dynamics. Thus, the associated changes may instead appear as deviations in the regularity, altered persistence or different temporal organisation [14].
This motivates the investigation of additional measures capable of describing the organisation and dynamics of the gaze position sequence itself using complexity and nonlinear dynamics measures. In this regard, complexity and nonlinear analyses are common methods used for characterisation and parametrisation of different biomedical signals derived from nonlinear dynamic systems. Complex, irregular and nonstationary dynamical systems represent many biological objects and physiological events, but detecting their relevant hidden properties is not straightforward because no clear rules describe their behaviour. Thus, exploring the observations of these systems requires appropriate and specific methods. In this context, nonlinear time series analysis is often used as an indirect approach to study the system's structure and dynamics.
The oculomotor system, which controls the muscles that move the eyes, is also a complex nonlinear dynamical system. Under the assumption that the monitoring of the oculomotor system can be carried out indirectly using the gaze positions obtained by an eye tracker device, the underlying hypothesis of this study is that a complexity analysis of the SPEM represents a potential window to evaluate pathological behaviours in the oculomotor system. In addition, a complexity analysis of SPEM in PD patients is expected to reveal significant information for a proper understanding of the oculomotor mechanisms of Parkinsonian patients. Additionally, according to the theory of complexity loss with ageing and disease progression [14], a complexity analysis is expected to derive indicators able to characterise the deviations of the oculomotor system due to the underlying pathophysiological condition introduced by PD.
The literature reports complexity and nonlinear dynamics measures applied to the screening of PD using different biometrics, such as Electroencephalogram (EEG), voice and gait [15, 16, 17]. Besides, the complexity and nonlinear dynamics of eye movement sequences have been applied to characterise other ocular tasks different from SPEM, such as fixations [18], saccades [19], visual search [20] and accommodation [21]. However, these measures have received almost no attention to characterise continuous SPEM recordings from participants with PD. To our knowledge, only the preliminary study in [22] has used measures of complexity and nonlinear dynamics extracted from SPEM recordings for the automatic screening of PD, reporting moderate discrimination capabilities. Thus, evidence remains limited on whether these measures discriminate participants with PD from HCs and about their discriminative information across pursuit tasks and axes.
Regarding the automatic screening of PD using biometrics extracted from eye movements following other feature engineering approaches, the literature is also scarce. In this regard, the work presented in [23] recorded an interleaved prosaccade and antisaccade task with a video-based eye tracker to categorise 121 patients with PD and 106 HCs, classifying them from saccade, pupil and blink features with machine learning, obtaining an Area Under the Curve (AUC) of 0.88. The authors in [24] recorded gaze stability, prosaccade, antisaccade and SPEM tasks in a virtual reality environment from 114 patients with PD and 125 HCs, using a deep learning model to categorise both classes, and reporting an AUC of 0.97 in cross-validation. The work in [25] also used virtual reality eye tracking with saccade, antisaccade and SPEM paradigms from 44 patients with PD and 34 HCs, and a model combining three oculomotor parameters, reporting an AUC of 0.93. On the other hand, [26] analysed smartphone videos of 18 patients with PD and classified 2-s windows of horizontal pursuit as normal or abnormal with a deep learning model, thus identifying abnormal pursuit events rather than patients with PD. In these studies, SPEM were either not used or were one of several tasks, so their specific contribution was not analysed, and the different tasks, technologies, units of analysis and validation designs prevent a direct comparison of their performance.
On the other hand, the strategy followed to preprocess the SPEM sequences is also a relevant issue to be studied before any feature extraction as a prior step to extract the most relevant information and to remove potential biases. Blinks produce missing blocks and artificial transitions [27], requiring methods to compensate them. Slow components associated with the presence of a Baseline Wander (BW) can modify the temporal and amplitude structure [28]. In addition, differences in the coordination of both eyes can also affect the analysis, which is addressed by estimating the Cyclopean Eye Residual Movement (CERM) component, representing the component common to both eyes [29]. The potential introduction of these preprocessing strategies significantly modifies the characteristics of the sequences obtained, also affecting both their interpretation and the information available to feed a classifier. Thus, a specific study of the effect introduced by each of these preprocessing strategies is mandatory to fill the associated gap.
This work presents and evaluates an automatic classification pipeline to support PD screening from SPEM recordings. Complexity and nonlinear dynamics measures are extracted from gaze position sequences preprocessed following different strategies. A common feature subset is selected to feed different Support Vector Machines (SVMs), each associated with a pursuit task and axis. In addition, their outputs are combined through a Mixture of Experts (MoE) approach to produce one final score per participant. The central question to answer is whether the measures considered provide consistent discrimination between participants with PD and HCs, while the proposed pipeline is intended to support the screening and biomarker research, not to replace clinical diagnosis.
Participants and clinical assessments
Fifty-two participants with early PD and 48 HCs, matched for age and sex, were recruited. Mean age was 63.80 years in the PD group (range: 44–84) and 64.26 years in the HC group (range: 46–80).
Participants were required to maintain a stable head position, follow the target throughout the Smooth Pursuit Tasks (SPTs) and provide recordings that met the technical quality requirements. Twelve participants, comprising 11 with PD and one HC, were excluded because they could not complete the SPTs or because their recordings presented quality problems, including double corneal reflections. This left 41 participants with early PD and 47 HCs for the main analysis. The same requirements were applied to both diagnostic groups; they define the population to which the results apply as participants who can complete the SPTs and provide technically valid recordings.
Data were collected over 2 years at Hospital Universitario de Fuenlabrada and Hospital General Universitario Gregorio Marañón (Community of Madrid, Spain) using the same protocol, equipment and clinical team.
Clinical evaluation included medical history, age at PD diagnosis, time since diagnosis, symptoms, complications, the Unified Parkinson's Disease Rating Scale (UPDRS), the Montreal Cognitive Assessment (MoCA) and the Beck Depression Inventory. Table 1 summarises the demographic and clinical characteristics. All participants with PD were assessed in the ON-medication state after taking their usual antiparkinsonian medication at the normally scheduled time.
The ethics committees of both hospitals approved the protocol and all participants provided written informed consent.
Recording and smooth pursuit tasks
Binocular eye movements were recorded at 1000 Hz with an EyeLink 1000 Plus infrared video eye tracker (SR Research Ltd, Ontario, Canada). One computer controlled the system and another presented stimuli on an LED monitor 60 cm from the participant. A chin rest was positioned 50 cm from the upper camera knob and the system was calibrated before each session using a nine-point grid.
Participants fixated on a small white central dot for 200 ms before a red target moved along horizontal, vertical or two-dimensional lemniscate trajectories (Fig. 1); each trajectory type included four frequency and amplitude combinations (Table 2) [22]. All participants performed 12 SPTs in a fixed order from SPT1 to SPT12. During each SPT, timestamped X and Y gaze positions were recorded for both eyes. The ordered samples for each eye and axis formed one univariate gaze position sequence, yielding four per recording. The target trajectory denotes the complete spatial path, whereas a target position sequence contains its samples over time along one axis.
Methods
The development set (70 participants: 33 with PD and 37 HCs) was used to design and train the classification pipeline. The external test set (8 participants with PD and 10 HCs) was used only for its final evaluation and the Young Control (YC) cohort (12 participants; mean age 25 years, range 23–30) only to describe its predictions for younger healthy participants.
Preprocessing
Preprocessing was implemented in MATLAB . Blink correction was applied to all gaze position sequences, whereas BW removal and CERM extraction were applied or omitted to define four Experimental Frameworks (EFs) (Table 4).
Blink detection and imputation. Complete eyelid closure produces missing intervals, often bordered by nonphysiological amplitude changes. An algorithm based on [29] expanded each interval across these changes until smoother transitions were reached and reconstructed the removed segment with Singular Spectrum Analysis (SSA) [30] (Fig. 2). The blink-corrected gaze position sequences of the two eyes are shown in Fig. 3a–b.
Table 1: Demographic and clinical characteristics of the participants included in the main analysis. Continuous variables are mean ± standard deviation and male sex is number (percentage). Dashes denote variables specific to participants with PD.
| Variable | All participants (n = 88) | PD (n = 41) | HCs (n = 47) |
|---|---|---|---|
| Age, years | 63.17 ± 8.56 | 62.29 ± 8.91 | 63.96 ± 8.26 |
| Male sex, n (%) | 44 (50.00%) | 24 (58.54%) | 20 (42.55%) |
| MoCA score | 26.39 ± 3.04 | 26.03 ± 3.56 | 26.70 ± 2.52 |
| UPDRS score | 8.01 ± 10.68 | 17.58 ± 9.38 | 0.28 ± 0.83 |
| Age at diagnosis, years | — | 60.18 ± 8.36 | — |
| Time since diagnosis, years | — | 1.73 ± 0.78 | — |

(a)

(b)

(c)

(d)
Figure 1: Stimulus trajectories used in the 12 SPTs: (a) horizontal trajectories used in SPT1–SPT4; (b) vertical trajectories used in SPT5–SPT8; (c) horizontal lemniscate trajectories used in SPT9 and SPT10; and (d) vertical lemniscate trajectories used in SPT11 and SPT12. Participants were instructed to fixate on the white central point for 200 ms before a red target moved in the direction indicated by the arrows. Target frequency and amplitude varied across SPTs as detailed in Table 2.
Baseline wander removal. Calibration, environmental noise, visual impairments, head movement and attention introduce a low-frequency BW into the gaze position sequences. BW was estimated and removed with a method based on the Empirical Wavelet Transform (EWT) [28] (Fig. 3c).
Extraction of the CERM component. Independent Component Analysis (ICA) was applied to the gaze position sequences of the two eyes, before or after BW removal, to extract the CERM sequence, which is assumed to represent the motor commands common to both eyes [29] (Fig. 3d–e).
Feature extraction
Complexity and nonlinear dynamics measures were computed from each gaze position sequence for each participant, SPT, eye and axis. A measure is one of the 38 quantities in Table 3, whereas a feature is the value of a measure for one eye and axis in one SPT. The measures characterise the temporal and spatial organisation of the sequence rather than its relation to the target position.
Phase space reconstruction. Measures requiring an embedding were computed from delay vectors defined by the Embedding Delay (EDel) and Embedding Dimension (EDim) [31, 32]. Four Delay Strategies (DSs) were compared to select the EDel: DS1 used a fixed value of
Table 2: Target frequency and amplitude for the 12 SPTs.
| X frequency (Hz) | X amplitude (°) | Y frequency (Hz) | Y amplitude (°) | ||
|---|---|---|---|---|---|
| Horizontal | SPT1 | 0.2 | 6 | 0 | 0 |
| SPT2 | 0.2 | 9 | 0 | 0 | |
| SPT3 | 0.4 | 6 | 0 | 0 | |
| SPT4 | 0.4 | 9 | 0 | 0 | |
| Vertical | SPT5 | 0 | 0 | 0.2 | 4 |
| SPT6 | 0 | 0 | 0.2 | 7 | |
| SPT7 | 0 | 0 | 0.4 | 4 | |
| SPT8 | 0 | 0 | 0.4 | 7 | |
| 2D | SPT9 | 0.2 | 6 | 0.4 | 3 |
| SPT10 | 0.2 | 9 | 0.4 | 6 | |
| SPT11 | 0.4 | 3 | 0.2 | 6 | |
| SPT12 | 0.4 | 3 | 0.2 | 7 | |

Figure 2: Blink imputation for participant HF011 (HC) during SPT12, using the gaze position sequence from the left eye along the X axis. Grey regions denote segments reconstructed with SSA.
25 samples (25 ms at 1 kHz); DS2 used the first local minimum of the Average Mutual Information (AMI) curve of the target position sequence; and DS3 and DS4 used the first local minimum and the 1/e decay, respectively, of the AMI curve of the gaze position sequence [33]. DS2 gave one EDel for each SPT and axis, whereas DS3 and DS4 gave one for each participant. The EDim was estimated for each sequence with False Nearest Neighbours (FNN) [34] (Appendix A).
Complexity and nonlinear dynamics measures. The 38 measures were organised into seven families according to the property they describe (Table 3). EntropyHub® was used to compute Approximate Entropy (ApEn), Sample Entropy (SampEn) and the plain, normalised and conditional variants of Fine-grained Permutation Entropy (FGPE), Modified Permutation Entropy (mPE), Amplitude-aware Permutation Entropy (AAPE), Edge Permutation Entropy (ePE) and Uniform Quantisation-based Permutation Entropy (UQPE) [35]. NeuroKit2® was used to compute Shannon Entropy (ShEn), Maximum Entropy (MaxEn), Differential Entropy (DiffEn), Power Entropy (PowEn), Tsallis Entropy (TE), Hartley Entropy (HEn), Collision Entropy (CEn), Corrected Approximate Entropy (cApEn), Quadratic Sample Entropy (QSE), Permutation Entropy (PE), Weighted Permutation Entropy (wPE), Conditional Permutation Entropy (cPE), Conditional Weighted Permutation Entropy (cwPE), Conditional Rényi
Experimental framework 1 — left eye, no baseline wander removal

a)
Experimental framework 1 — right eye, no baseline wander removal

b)
Experimental framework 2 — left and right residual after baseline wander removal

c)
Experimental framework 3 — cyclopean eye residual movement, no baseline wander removal

d)
Experimental framework 4 — cyclopean eye residual movement, after baseline wander removal

e)
Figure 3: Four EFs for participant HF009 (HC) during SPT11 along the X axis: gaze position sequences and estimated BW for the left and right eyes before removal (a,b); both gaze position sequences after removal (c); and CERM sequences obtained without (d) and with (e) prior BW removal.
Permutation Entropy (cRPE), Largest Lyapunov Exponent (LLE), Lempel–Ziv Complexity (LZC), Katz’s Fractal Dimension (KFD) and Petrosian Fractal Dimension (PFD) [36]. Nolds was used to compute Hurst Exponent (HE) and Detrended Fluctuation Analysis (DFA) and to construct the delay vectors for Correlation Dimension (CD) [37].
Experimental setup
The four EFs and the four DSs were combined into 16 experimental settings (Table 4), so that preprocessing and delay strategy could be compared separately.
Preliminary selection of the experimental setting and organisation of the base models
The development set was used to select the DS, compare the EFs and define the organisation of the base models, that is, the SVMs whose outputs are combined in the MoE. All comparisons used the same logistic regression classifier ( regularisation, C = 1), so that classifier optimisation did not confound them. Performance was estimated by Leave-One-Participant-Out (LOPO) Cross-Validation (CV), with standardisation fitted within each training fold and AUC calculated from the pooled out-of-fold predictions [62].
The DSs were compared by AUC using all features, the features computed from delay vectors and the features computed directly from the sequence; only the second set depends on the EDel and EDim. To interpret the temporal scale captured by the features computed from delay vectors, the temporal span of the delay vectors was calculated for each DS:
Table 3: Complexity and nonlinear dynamics measures, the sequence property described by each family and whether its measures are computed from delay vectors.
| Family | Measures | Sequence property | Delay vectors |
|---|---|---|---|
| Informational entropy | ShEn [38], MaxEn [39], DiffEn [38], PowEn [38, 36], TE [40], HEn [41], CEn [42] | Uncertainty and distributional information in sequence amplitudes. | No |
| Temporal entropy | ApEn [43], cApEn [44], SampEn [45], QSE [46] | Regularity and recurrence of temporal patterns. | Yes |
| Ordinal and permutation entropy | PE [47], wPE [48], cPE [49], cwPE [48, 49], cRPE [42, 49]; plain, normalised and conditional forms of FGPE [50], mPE [51], AAPE [52], ePE [53] and UQPE [54] | Diversity, transitions, amplitudes and modifications of ordinal patterns. | Yes |
| Symbolic complexity | LZC [55] | Novelty rate of symbolic patterns. | Yes |
| Geometric and fractal | KFD [56], PFD [57] | Geometric waveform complexity. | No |
| Phase space dynamics | LLE [58], CD [59] | Divergence and dimensionality of reconstructed trajectories. | Yes |
| Memory and scaling | HE [60], DFA [61] | Long-range dependence and scaling behaviour. | No |
Table 4: The 16 experimental settings formed by the four EFs and four DSs.
| Delay Strategy → Experimental Framework ↓ | DS1Fixed delay25 samples | DS2Target position AMI first minimum | DS3Gaze position AMI first minimum | DS4Gaze position AMI 1/e decay |
|---|---|---|---|---|
| EF1 | ||||
| No BW removal | ||||
| No CERM extraction | EF1–DS1 | EF1–DS2 | EF1–DS3 | EF1–DS4 |
| EF2 | ||||
| BW removal | ||||
| No CERM extraction | EF2–DS1 | EF2–DS2 | EF2–DS3 | EF2–DS4 |
| EF3 | ||||
| No BW removal | ||||
| CERM extraction | EF3–DS1 | EF3–DS2 | EF3–DS3 | EF3–DS4 |
| EF4 | ||||
| BW removal | ||||
| CERM extraction | EF4–DS1 | EF4–DS2 | EF4–DS3 | EF4–DS4 |
where is the EDim and the EDel [32]. With the selected DS, three organisations of the base models were compared by AUC: one base model for each SPT, pooling both axes and both eyes (12 base models); one base model for each SPT and axis, pooling both eyes (24 base models); and one base model for each SPT, axis and eye (48 base models). The four EFs were then compared by AUC with all features and by Cohen's , to check whether the direction of each family was preserved [63].
To interpret differences between EFs, the effect of BW removal and CERM extraction on the sequences was described in terms of global dispersion and local variation between consecutive samples. For BW removal, global dispersion was measured by the standard deviation of the sequence and local variation by the standard deviation of its first differences, . Because the scale and sign of the components extracted by ICA are arbitrary, each CERM sequence is min-max normalised to [0, 1] [29], whereas the gaze position sequences retain the units of the eye tracker, recorded with the same geometry for all participants. The amplitude of the two cannot be compared directly, so CERM extraction was assessed by the relative local variation, defined as the standard deviation of the first differences divided by the standard deviation of the sequence. It was calculated for the complete sequence and in 50 ms windows with 50% overlap. The values from the two eyes were averaged before comparison with the CERM sequence. For each participant, SPT and axis, the change in each statistic was expressed as , so that indicates a reduction. Ratios were summarised within participants and diagnostic group medians with 95% confidence intervals were estimated from 10 000 bootstrap repetitions that resampled participants. These analyses were descriptive and were not used to select the EF.
The selected experimental setting and organisation of the base models were fixed before feature selection and model selection.
Classification pipeline and validation strategy
Each base model was an SVM trained on the features of one SPT, and all base models were combined into an MoE (Fig. 4), in which they play the role usually referred to as experts [64]. The assignment of axes and eyes to base models was fixed by the preliminary analysis described above. All base models shared the same feature subset and SVM configuration. Selecting them separately for each base model would multiply the choices fitted to 70 participants and increase the risk of overfitting. The pipeline therefore required three choices: the feature subset, the SVM configuration and the combiner. They were made using 20 repeated holdouts of the development set, each with 56 training and 14 validation participants and with all recordings of a participant in the same partition. The pipeline was implemented with scikit-learn [65].
Every choice was evaluated with the complete MoE, because participants are classified by the combined output rather than by individual base models. The criterion was the geometric mean of sensitivity and specificity (G-mean) on the validation participants, which is given by:
which is high only when both diagnostic groups are correctly classified [66]. Configurations were ranked by:
which penalises variability across holdouts and positive training–validation gaps, so that stable configurations that do not overfit rank higher [67].
The SVM hyperparameter search covered C, kernel type, for the Radial Basis Function (RBF) kernel and class weight, with logarithmic grids for C and [68]. Class weights tested whether a greater cost for misclassifying PD improved classification [69]:
Each of the 48 SVM configurations was evaluated jointly with each of the eight combiner configurations described below.
Feature selection
Feature selection combined two stages: Hierarchical Feature Selection (HFS) removes redundant measures without class labels and Forward Feature Selection (FFS) retains the relevant ones [70, 71]. Both stages operated on measures, so that each retained measure provided its features for every eye and axis of the base models. To assess the contribution of each stage, the pipeline was also evaluated with the complete feature set and with the Representative Feature Set (RFS), formed by the features of the representative measures obtained with HFS.
Hierarchical Feature Selection. Many measures, such as the variants of PE, are alternative definitions of the same quantity and are strongly correlated. When features are nearly collinear, the weight assigned to each one is not identifiable and its importance depends on noise [72]. HFS removes this redundancy by grouping strongly correlated measures and keeping one measure per group.
Two measures were considered redundant when their absolute Spearman correlation was at least 0.80 in at least 80% of the 48 combinations of SPT, eye and axis, so that redundancy held across recording conditions. Spearman correlation was used to capture monotonic, not only linear, relations. To ensure that redundancy did not depend on particular participants, this criterion was evaluated in repeated subsamples of the development participants [73, 74]. For each pair of measures i and j, the consensus was the proportion of subsamples in which the pair was redundant; indicates that the two measures were redundant in every subsample. Measures were then grouped so that every pair within a group had . This grouping was obtained by agglomerative hierarchical clustering with distance and complete linkage, which constrains every pair within a group rather than their average [75].
Each group was represented by the member most strongly associated with the rest of the group [76]. Keeping an original measure rather than a combination such as a principal component preserves its interpretation. Because HFS does not use class labels, it was applied once to the complete development set without biasing the holdout estimates [77].
Forward Feature Selection. A measure without redundant copies may still carry no discriminative information. Uninformative features increase the variance of the classifier without improving discrimination, which raises the risk of overfitting in a small sample [78]. FFS retains the relevant representatives as a wrapper method [71]. Starting from an empty subset, each step added the representative that most increased the G-mean of the complete MoE, so that measures were evaluated in combination. FFS was applied to the RFS to avoid arbitrary choices between nearly identical measures.
Forward selection is unstable [73, 74], so FFS was repeated on 10 inner partitions of the training participants of each holdout, giving 200 runs. A representative was retained when it was selected in more than a fraction f of them [79]. The value of f was chosen within the holdouts by the G-mean of the resulting subsets. The SVM configuration and combiner were then selected again with the final subset. To assess whether FFS selected better than chance, the final subset was compared with 20 random subsets with the same number of representatives and fitted with the same procedure.
Mixture of Experts combination and final evaluation
Each base model produced one SVM decision score per participant, which was converted into a probability using Platt scaling [80]. Three combiners of increasing flexibility were compared: the simple mean, the mean weighted by AUC and logistic regression stacking [81, 82]. The simple mean fits no parameters, the weighted mean favours the most discriminative base models and logistic regression stacking learns the weight of each base model from the training participants. The product rule, which multiplies

Figure 4: Overview of the pipeline: from preprocessing and feature extraction to participant-level classification and external evaluation.
the probabilities of the base models or, equivalently, sums their logarithms, was not considered because it assumes that the base models are conditionally independent given the class, which does not hold for base models computed from recordings of the same participant [81].
Let be the calibrated probability from base model e and E the number of base models. Averaging compresses probabilities towards 0.5, so the two means rank the participants but are not calibrated probabilities. Each mean, denoted by s, was therefore mapped to a probability with a logistic recalibration [83]. The simple mean is given by:
where is the logistic sigmoid, its inverse, and the slope and intercept were estimated from out-of-fold scores of the training participants of each holdout.
The weighted mean uses the AUC of each base model, calculated within the training participants of each holdout:
where the slope and intercept were also estimated from out-of-fold scores of the training participants of each holdout.
Logistic regression stacking is based on a logistic regression model applied to the predictions of the base models, which acts as a meta-model that combines them into a single probability. It is defined as:
where is the output probability of the combiner, the intercept and the coefficient of base model e. As is already a probability, it was used without recalibration. The search space of this combiner was
After model selection, the combiner and calibration model parameters (weights of the base models and, where applicable, regression intercepts and calibration slopes) were averaged across the 20 holdouts to obtain a single calibrated combiner. Development performance was reported as the mean (standard deviation) of the performance metrics obtained by applying this combiner to the validation participants in each holdout. The decision threshold was selected on the resulting 280 validation predictions rather than on the training predictions, because thresholds tuned on the training data are optimistic and may not transfer to new participants [84]. It was set at the Equal Error Rate (EER) operating point, at which the false positive and false negative rates are equal [85], so that both errors were weighted equally, as in the G-mean.
For external evaluation, the base models were refitted on the complete development set, and their predictions were combined and calibrated using these averaged parameters, with the same decision threshold. The pipeline was then evaluated once on the external test set. Confidence intervals of 95% were obtained from 10 000 bootstrap resamples.
stratified by diagnostic group for AUC and G-mean and from Wilson intervals for sensitivity and specificity [86].
Contributions were computed in the development participants and expressed as a percentage of the total. The contribution of each base model was its mean absolute contribution to the output of the combiner. The contribution of each feature within a base model was its mean absolute SHAP value, which, unlike the SVM coefficients, is also defined for the RBF kernel [87], weighted by the contribution of the base model so that it referred to the final prediction. The direction of a feature was the sign of the association between its values and its SHAP values and was compared with the sign of Cohen's d between participants with PD and HCs [63].
The same pipeline was applied to the YC cohort to compare its probabilities with those of the external HCs and participants with PD.
Results
Selection of the experimental setting and organisation of the base models
The preliminary analyses selected EF2–DS1 and one base model for each SPT and axis, which received the features of each measure from both eyes (Table 5). The complete comparison of DSs is reported in Supplementary Table S1. Pooling both eyes and both axes gave an AUC of 0.66. Separating the axes while keeping both eyes pooled yielded performance close to chance for the Y axis and a slightly higher AUC of 0.68 for the X axis compared with pooling both axes. Further separating the eyes within each axis yielded similar values for the left and right eyes along the X axis, both close to that obtained with both eyes pooled, while Y axis performance remained close to chance for either eye (Table 5; Supplementary Table S2).
BW removal reduced the standard deviation of the sequence by 83.00% and the standard deviation of its first differences by 3.00%. CERM extraction reduced the relative local variation, with median ratios in 50 ms windows of 0.81 for EF3/EF1 and 0.89 for EF4/EF2 (Supplementary Table S3). In the effect size analysis, BW removal reduced the absolute Cohen's d of PowEn, which depends on amplitude, whereas that of SampEn changed little. Following CERM extraction, differences were observed in both effect magnitude and direction, including reversals for PowEn and SampEn. Other measures, such as DFA, HE, PFD and LLE, showed changes in magnitude while retaining their effect direction across the four EFs (Supplementary Table S4).
Feature selection
Hierarchical Feature Selection. HFS reduced the 38 measures to 20 representatives. The largest groups contained the nine variants of PE and five informational entropies, and DiffEn was grouped with PowEn. The median absolute Spearman correlation was 0.96 between measures of the same group and 0.31 between measures of different groups.
Removing this redundancy changed the distribution of the contribution. With the complete feature set, contribution was spread almost evenly among the members of each group, and 10.61% of the pairs of features from measures of the same group were used in opposite directions. The features of measures in redundancy groups collectively accounted for 51.22% of the total contribution before redundancy removal and 22.21% afterwards, when only their representatives were retained. Conversely, the features of measures without redundant partners increased their combined contribution from 48.78% to 77.79%.
Forward Feature Selection. FFS retained 13 out of 20 representatives, those selected in more than 40.00% of the 200 runs: HE, wPE, LZC, FGPE, normalised FGPE, cwPE, conditional UQPE, conditional AAPE, DiffEn, CD, KFD, PFD and cApEn. Their development G-mean (0.83) was higher than that of all 20 random subsets of 13 representatives (mean 0.78).
Table 6 compares the three feature sets. The RFS maintained the development performance of the complete feature set with 20 measures. HFS+FFS obtained the highest mean AUC and G-mean and the lowest G-mean variability with 13 measures.
Performance of the selected pipeline
The joint search selected an SVM with an RBF kernel and a weight of 5 for the PD class) and logistic regression stacking with regularisation and .
Table 6 reports the development performance with a decision threshold of 0.49. On the external test set, the AUC was 0.86 (95% confidence interval: 0.65–1.00). Six out of 8 participants with PD and 8 out of 10 HCs were correctly classified, giving a sensitivity of 0.75 (0.41–0.93), a specificity of 0.80 (0.49–0.94) and a G-mean of 0.77 (0.55–0.95) (Fig. 5).
The YC cohort was not used to develop the pipeline, so its probabilities were compared with those of the external test set rather than with the development set. Nine out of 12 YCs were classified as HCs. Their median probability was 0.20, compared with 0.28 for the external HCs and 0.61 for the external participants with PD (Fig. 5b).
Base models and features of the selected pipeline
Base models. Fifteen out of 24 base models contributed to the combined output. The base models along the X axis accounted for 88.58% of the total contribution, with the largest contributions coming from those for SPT5, SPT4, SPT9 and SPT1 (Table 7). The highest development AUCs were obtained by the base models along the X axis for SPT4, SPT5 and SPT1. Base models along the X axis generally outperformed those along the Y axis, including during vertical target movement, while most base models
Table 5: Development set evidence used to select the experimental setting and organisation of the base models.
| Choice | Selected option | Main quantitative evidence |
|---|---|---|
| Delay strategy | DS1 | AUC: with all features and with features computed from delay vectors; temporal span of the delay vectors: 50–75 ms |
| Organisation of the base models | One base model for each SPT and axis, using features from both eyes; 24 base models in total | AUC: for the X axis and for the Y axis; for the left eye and for the right eye along the X axis |
| Experimental framework | EF2 | AUC: 0.76 for EF2, 0.71 for EF1, 0.66 for EF4 and 0.60 for EF3 |
Table 6: Participant-level performance of the three feature sets. Numbers in parentheses are measures; each measure provided one feature per eye. Development values are the mean (standard deviation) across the 20 holdouts. The external test set was evaluated with the selected feature set, shown in bold.
| Metric | Development set | External test set | ||
|---|---|---|---|---|
| All features (38) | RFS (20) | HFS+FFS (13) | HFS+FFS (13) | |
| AUC | 0.88 (0.05) | 0.90 (0.08) | 0.91 (0.06) | 0.86 |
| Sensitivity | 0.78 (0.17) | 0.78 (0.18) | 0.84 (0.11) | 0.75 |
| Specificity | 0.78 (0.18) | 0.78 (0.21) | 0.84 (0.16) | 0.80 |
| G-mean | 0.76 (0.10) | 0.77 (0.15) | 0.83 (0.06) | 0.77 |


Figure 5: Performance of the selected pipeline. (a) Receiver Operating Characteristic (ROC) curves; the development curve uses the mean validation probability of each participant across the 20 holdouts and the inset magnifies the upper-left corner. (b) MoE probabilities of the YC cohort and of the HCs and participants with PD in the development set (CV) and the external test set. The YC cohort is compared with the external test set because neither was used to develop the pipeline. Symbols denote individual participants and curves show density estimates.
along the Y axis performed close to chance (Supplementary Table S5).
Features. The eight measures with the highest contribution accounted for 75.34% of the total (Table 8). Ordinal and permutation entropy features accounted for 48.45% of the total contribution.
Table 7: Contribution (%) of the individual base models to the combined output, grouped by target movement. X and Y indicate the axis of each base model. Values of 0.00 correspond to base models without influence on the combined output.
| SPT | Target movement: X | Target movement: Y | Target movement: 2D | |||||
|---|---|---|---|---|---|---|---|---|
| X | Y | SPT | X | Y | SPT | X | Y | |
| SPT1 | 12.13 | 0.00 | SPT5 | 20.87 | 9.94 | SPT9 | 18.27 | 1.41 |
| SPT2 | 0.80 | 0.00 | SPT6 | 2.37 | 0.07 | SPT10 | 2.67 | 0.00 |
| SPT3 | 6.84 | 0.00 | SPT7 | 2.44 | 0.00 | SPT11 | < 0.01 | 0.00 |
| SPT4 | 18.52 | 0.00 | SPT8 | 2.55 | 0.00 | SPT12 | 1.12 | 0.00 |
Table 8: Eight measures with the highest contribution to the combined output, reported separately for each eye. Each value combines the X and Y axes. Contr.: contribution, expressed as a percentage of the total across all features and base models; the total adds both eyes and determines the order of the rows. Direction: diagnostic group with which the model associated higher values and, in parentheses, number of the 15 active base models with that direction. d: median Cohen’s d across the active base models, computed as the difference between the PD and HC means divided by the pooled standard deviation.
| Measure | Total (%) | Left eye | Right eye | ||||
|---|---|---|---|---|---|---|---|
| Contr. (%) | Direction | d | Contr. (%) | Direction | d | ||
| wPE | 13.40 | 7.55 | PD (13/15) | 0.45 | 5.85 | PD (12/15) | 0.36 |
| HE | 10.81 | 7.81 | HC (14/15) | -0.47 | 3.00 | PD (10/15) | 0.03 |
| LZC | 10.42 | 6.41 | HC (14/15) | -0.16 | 4.01 | PD (8/15) | 0.15 |
| Conditional UQPE | 9.51 | 4.95 | PD (9/15) | 0.29 | 4.56 | PD (8/15) | 0.20 |
| CD | 8.71 | 3.11 | PD (13/15) | 0.07 | 5.60 | PD (10/15) | 0.07 |
| DiffEn | 8.52 | 4.49 | PD (10/15) | 0.15 | 4.03 | PD (13/15) | 0.24 |
| FGPE | 7.02 | 2.46 | HC (12/15) | -0.16 | 4.56 | HC (12/15) | -0.32 |
| KFD | 6.96 | 2.86 | PD (9/15) | 0.20 | 4.10 | PD (11/15) | 0.28 |
The HE of the left eye was the individual feature with the highest contribution. Higher values were associated with HCs in 14 out of 15 active base models and Cohen’s d was negative in all 15, whereas the HE of the right eye showed no difference between diagnostic groups. The wPE was higher in participants with PD in both eyes. Across all base models and features, the direction of the association agreed with the sign of Cohen’s d for 82.95% of the total contribution.
Discussion and Conclusions
On the external test set, the selected pipeline obtained an AUC of 0.86. Its most consistent feature pattern was lower temporal persistence in participants with PD, measured by the HE of the left eye and complemented by changes in ordinal organisation captured mainly by wPE.
Interpretation of the selected experimental setting. With DS1, an EDel of 25 ms and an EDim of 3 or 4 gave delay vectors spanning 50–75 ms, whereas the other strategies spanned hundreds of milliseconds to seconds and obtained lower AUC with the features computed from delay vectors (Supplementary Table S1). Short temporal relations were therefore the most discriminative within this dataset, but this does not establish this scale as physiologically optimal. Ideally, this scale should be shorter than the oculomotor events of interest, so that each delay vector describes the dynamics within an event. Saccades typically last 30–80 ms [88], so a span of 50–75 ms may combine parts of a catch-up saccade with the surrounding pursuit [10].
BW removal strongly reduced global dispersion while largely preserving local variation (Supplementary Table S3). The BW arises from sources such as calibration and head movement and can mask faster fluctuations, so its removal has been reported as a necessary step for the automatic analysis of SPEM sequences [28]. The higher AUC of EF2 is consistent with these fluctuations carrying discriminative information, although whether they arise from corrective movements, pursuit variability or measurement noise cannot be determined here. The effect of BW removal on Cohen’s d depended on whether a measure is sensitive to amplitude (Supplementary Table S4). PowEn, which describes the amplitude distribution and was grouped with DiffEn by HFS, lost most of its group difference (from 0.53 to 0.08). SampEn, which uses a tolerance proportional to the standard deviation and is therefore insensitive to amplitude [45], kept it (from 0.38 to 0.35).
CERM extraction changes the sequence in two ways. It is obtained from whitened sequences and normalised to [0, 1], which removes the amplitude differences between participants, and it discards the component not shared by both eyes, which contains recording artefacts and the effects of convergence deficits and eye dominance [29]. It also reduced the relative local variation and coincided with lower discrimination in EF3 and EF4. Both changes are reflected in Cohen's d: the group difference of PowEn reversed, consistent with the loss of amplitude information, and that of SampEn also reversed, although it is insensitive to amplitude. The reversal of SampEn is consistent with part of the more irregular local fluctuations in PD being specific to each eye and therefore removed with the non-shared component. These associations, however, do not establish that the transformations caused the reduction in performance.
Base models were separated by axis but not by eye. The two axes differed widely in discrimination, whereas the two eyes gave similar results along the X axis, as expected from their conjugate movement during pursuit, so separate base models for each eye would have doubled the number of base models without adding discriminative information (Supplementary Table S2). Sharing one feature subset and one SVM configuration across base models limited the number of choices fitted to 70 participants, at the cost of not adapting the feature subset to each SPT and axis.
Feature selection. With the complete feature set, redundancy distorted the interpretation of the model. Groups of correlated measures accumulated more contribution than their representatives because the contribution was spread over the features of several nearly identical measures. Nearly identical features were also sometimes used in opposite directions. Both effects are expected when the weight of collinear features is not identifiable [72]. HFS removed this redundancy without reducing development performance, so the contributions of the selected model can be interpreted feature by feature. FFS then retained the representatives that improved classification. The selected subset outperformed random subsets of the same size, so its benefit did not arise only from using fewer measures (Table 6).
Interpretation of the selected measures. A feature is described as higher or lower in participants with PD when its median Cohen's d is positive or negative, respectively, and a measure when this holds for the features of both eyes (Table 8).
The HE of the left eye had the highest contribution and was lower in participants with PD consistently across the active base models, whereas the HE of the right eye showed no difference between diagnostic groups. This difference between eyes may relate to ocular dominance, the clinically more affected side or altered binocular coordination in PD [8]; none of these factors was recorded or analysed. Values remained above 0.50 in both diagnostic groups, so the lower HE indicates weaker temporal persistence rather than anti-persistence [89]: the gaze maintained its direction of movement for shorter periods. This may reflect shorter periods of stable pursuit, more frequent transitions between smooth tracking and correction or altered organisation of successive corrections, which is compatible with previous reports of reduced gain, altered velocity and phase and fragmented pursuit in PD [3, 9]. Evidence of altered basal ganglia output and impaired extraretinal pursuit in PD is consistent with less stable automatic or predictive control, although the present data do not identify its neural origin [90, 91].
wPE, DiffEn and KFD were higher in participants with PD in both eyes. Higher wPE indicates less predictable local fluctuations [48], higher DiffEn a wider distribution of gaze positions [38] and higher KFD a more irregular waveform [56]. In terms of tracking, the three measures describe gaze that fluctuates more irregularly. Conditional UQPE was also higher in both eyes, but its model direction was inconsistent across base models. Together with the lower HE of the left eye, these measures describe gaze position sequences in PD that are less persistent and more irregular at short time scales, a profile consistent with less stable pursuit interrupted by frequent small corrections. The measures, however, do not identify the events involved.
FGPE was lower in participants with PD in both eyes, in the opposite direction to wPE, so ordinal and permutation entropy measures cannot be summarised as higher or lower complexity in PD. LZC showed small effects of opposite sign in the two eyes and CD showed no difference between diagnostic groups, although both contributed to the model. Their contribution therefore arose in combination with the other features rather than from a group difference of their own.
Distribution of information across axes and SPTs. The X axis predominated in the discrimination of individual base models and in their contribution, including during vertical trajectories (Table 7; Supplementary Table S5). During vertical pursuit, it may capture transverse deviations, corrections or saccadic intrusions around the intended trajectory. Normal directional differences in pursuit, target dynamics, calibration, head position and measurement precision remain alternative explanations [92, 93]. The X axis was therefore the most informative source under this protocol, which does not imply a preferential impairment of horizontal pursuit. Because the 12 SPTs were administered in a fixed order, differences between SPTs cannot be attributed exclusively to their trajectory, frequency or amplitude; adaptation, attention, fatigue or learning may have contributed.
External evaluation and clinical scope. The external AUC had a wide confidence interval because the test set contained 18 participants. Sensitivity and specificity were similar, so the classification was balanced between diagnostic groups, as expected from the EER threshold. This supports generalisation to unseen participants under comparable acquisition conditions, but does not establish transportability across centres, devices, operators or implementations. Screening, in which false negatives have a greater clinical cost, would require a prospectively defined threshold that favours sensitivity.
The distributions of the YCs and the external HCs overlapped and 9 out of 12 YCs were classified as HCs (Fig. 5b). This provides no indication that predictions for healthy participants depended on age, although age and cognition were not modelled directly. This comparison only describes predictions for younger healthy participants; PD–HC discrimination was assessed on the external test set.
Other automatic studies used different eye movement tasks, technologies, outcomes, validation designs and units of analysis, which precludes direct numerical comparison [22, 23, 24, 25, 26]. The present study combines participant classification with an analysis of the temporal and spatial properties that support the predictions. Because eye movement abnormalities also occur in other neurological and Parkinsonian disorders, PD–HC discrimination does not establish diagnostic specificity [2].
Limitations and future work. The same 70 participants were used to select the feature subset, the SVM configuration, the combiner and the threshold, so the development estimates may overestimate performance on new participants. The external test set limits this risk, but its size prevents a precise estimate of the difference. The higher proportion of exclusions in the PD group limits applicability to participants with PD who can complete the protocol and provide technically valid recordings. All recordings were acquired with the same protocol, equipment and clinical team, so performance with other recording systems, protocols or clinical settings remains untested. Finally, the values of complexity and nonlinear dynamics measures depend on the length of the sequence, the parameters of each measure and the noise. A positive LLE in a finite, noisy and nonstationary recording, for example, does not demonstrate deterministic chaos [94]. The selected measures should therefore be interpreted as empirical descriptions of the gaze position sequences rather than as direct measurements of oculomotor control.
Larger studies with repeated measurements should assess associations with age, severity, medication, cognition and the clinically more affected side, together with feature and probability stability [95]. Event annotation and comparison with the target position sequence are needed to locate the observed patterns within smooth tracking, corrections or their transitions. Independent recruitment, other recording systems and neurological comparison groups are required to establish transportability and specificity.
Conclusions. The results support the feasibility of using complexity and nonlinear dynamics measures of gaze position sequences to distinguish participants with early PD from HCs. Within this dataset, the most informative representation combined a short reconstruction scale with BW removal and the separate gaze position sequences of the two eyes. The most important features described gaze position sequences in PD that were less persistent and fluctuated more irregularly at short time scales, a profile consistent with less stable pursuit. Evaluation on the external test set supported generalisation under comparable acquisition conditions, but its small size limits the precision of the estimate. The proposed pipeline should therefore be considered a candidate tool for screening and biomarker discovery rather than a replacement for clinical diagnosis.
Acknowledgements. The authors thank the participants; the Neurology Service of Hospital General Universitario Gregorio Marañón for its facilities; the Madrid ELLIS unit for indirect support; and Universidad Politécnica de Madrid for Magerit Supercomputer resources. Funding was provided by the Ministry of Economy and Competitiveness of Spain (DPI2017-83405-R1 and PID2021-128469OB-I00) and Comunidad de Madrid. Universidad Politécnica de Madrid supports Julián D. Arias-Londoño through the María Zambrano grant UP2021-035, funded by the European Union-NextGenerationEU.
CRediT Author Statement. Conceptualisation and Methodology: J.D.A., J.I.G.; Software: J.C.P., M.F.A., J.D.A.; Validation: J.C.P., M.F.A., J.D.A., J.I.G.; Investigation (participant recruitment and data acquisition): E.L.B., F.G.P.; Resources: F.G.P., J.I.G.; Writing—original draft: J.C.P., J.I.G.; Writing—review and editing: J.D.A., J.I.G.; Supervision: F.G.P., J.D.A., J.I.G.; Project administration and Funding acquisition: J.I.G. All authors read and approved the final manuscript.
Declaration of Competing Interests. The authors declare no competing interests.
A Embedding delay and dimension estimation
This appendix reports the EDel, EDim and temporal span obtained with each DS and explains why DS1 was used in the final pipeline.
A.1 Illustration of the delay strategies
Figure A.1 shows the four DSs for one HC and one participant with PD in SPT11. DS1 used 25 ms in both participants, whereas DS2–DS4 gave delays between 173 and 789 ms. The data-driven strategies therefore placed consecutive coordinates of each delay vector hundreds of milliseconds apart, whereas DS1 kept them within a few tens of milliseconds.
Gaze-position average mutual information

Target-position average mutual information

Three-dimensional projections of the reconstructed state space (delay-coordinate embedding)
Delay Strategy 1
Fixed delay
(no AMI estimate)
Delay Strategy 2
Target-position AMI
first minimum
Delay Strategy 3
Gaze-position AMI
first minimum
Delay Strategy 4
Gaze-position AMI first crossing
below AMI(0)/e
HC

c)
d)
e)
f)
PD

g)
h)
i)
j)
Figure A.1: Four DSs for participants HG060 (HC) and HF014 (PD) in SPT11, left eye, X axis, before BW removal. (a) AMI curves of the gaze position sequences for HC (dashed) and PD (solid); coloured lines denote the selected delays. (b) AMI curve of the target position sequence; the coloured line denotes the shared DS2 delay. (c–f) Three-dimensional phase space reconstructions for DS1–DS4 in HG060 (HC). (g–j) Corresponding phase space reconstructions for HF014 (PD).
A.2 Embedding delay of the data-driven strategies
In DS2, the first AMI minimum of the target position sequence gave an EDel between 558 ms and 1.02 s, which corresponded to 20%–22% of the target period in every SPT and axis with target movement. DS2 therefore tied the delay to the target period rather than to the gaze position sequence.
DS3 and DS4 gave one EDel for each participant and sequence (Fig. A.2). Median values ranged from 448 to 775 ms for DS3 and from 115 to 472 ms for DS4. Both strategies therefore produced delays about 5 to 30 times longer than DS1 that differed between participants, so the features computed from delay vectors described a different time scale for each participant.
DS3
DS4

Embedding delay (ms)
EF1 EF2 EF3 EF4 …… DS2
Figure A.2: EDel distributions for DS3 (first two columns) and DS4 (last two) by SPT and axis. Colours denote EF1–EF4; dotted lines show DS2. The horizontal axis is logarithmic and expressed in milliseconds.
A.3 Embedding dimension and temporal span
FNN estimated an EDim between 2 and 4 with DS1 and between 2 and 9 with the other strategies (Fig. A.3). Combined with each EDel through Eq. (1), this gave median temporal spans of 50–75 ms for DS1, compared with 2.02–2.24 s for DS2, 2.03–3.20 s for DS3 and 468 ms–1.60 s for DS4.
EF1 EF2 EF3 EF4

Embedding dimension m
Figure A.3: EDim distributions for DS1–DS4. Colours denote EF1–EF4, and bars show the percentage of sequences for each embedding dimension.
DS1 was therefore the only strategy whose delay vectors covered tens of milliseconds. The other strategies covered a substantial fraction of the target period, a scale at which the delay vectors are expected to reflect mainly the slow trajectory imposed by the target. Together with its higher AUC in the preliminary analysis (Table 5), this motivated the use of DS1 in the final pipeline, with an EDel of 25 samples and the EDim estimated for each sequence.
References
[1] L Cipparrone, A Ginanneschi, F Degl'Innocenti, P Porzio, P Pagnini, and P Marini. Electrooculographic routine examination in Parkinson's disease. Acta neurologica Scandinavica, 77(1):6–11, 1988.
[2] Chrystalina Antoniades and Miriam Spering. Eye movements in Parkinson's disease: From neurophysiological mechanisms to diagnostic tools. Trends in Neurosciences, 47(1):71–83, 2024.
[3] Karen Frei. Abnormalities of smooth pursuit in Parkinson's disease: A systematic review. Clinical Parkinsonism & Related Disorders, 4:100085, 2021.
[4] Kikuro Fukushima, Junko Fukushima, and Graham Barnes. Clinical application of eye movement tasks as an aid to understanding Parkinson's disease pathophysiology. Experimental Brain Research, 235(5):1309–1321, 2017.
[5] Michele Basso, Jennifer Pokorny, and Ping Liu. Activity of substantia nigra pars reticulata neurons during smooth pursuit eye movements in monkeys. European Journal of Neuroscience, 22(2):448–464, 2005.
[6] Hong Zhou, Xia Wang, Di Ma, Yanyan Jiang, Fan Li, Yunchuang Sun, Jing Chen, Wei Sun, Elmar Pinkhardt, Bernhard Landwehrmeyer, Albert Ludolph, Lin Zhang, Guiping Zhao, and Zhaoxia Wang. The differential diagnostic value of a battery of oculomotor evaluation in Parkinson's disease and multiple system atrophy. Brain and Behavior, 11(7):e02184, 2021.
[7] Klaus Rottach, David Riley, Alfred DiScenna, Ari Zivotofsky, and Robert John Leigh. Dynamic properties of horizontal and vertical eye movements in Parkinsonian syndromes. Annals of Neurology, 39(3):368–377, 1996.
[8] Chia-Chien Wu, Bo Cao, Veena Dali, Celia Gagliardi, Olivier Barthelemy, Robert Salazar, Marc Pomplun, Alice Cronin-Golomb, and Arash Yazdanbakhsh. Eye movement control during visual pursuit in Parkinson's disease. PeerJ, 6:e5442, 2018.
[9] Zvonimir Popović, Tihana Gilman Kurić, Ines Rajkovača Latić, Sara Matoša, Luka Kušić, Andrea de Gobbis, Aleksander Sadikov, Vida Groznik, Dejan Georgiev, and Svetlana Tomić. Smooth pursuit and memory saccades are impaired in early-stage Parkinson's disease patients. Frontiers in Neurology, 16:1702050, 2026.
[10] Sophie de Brouwer, Demet Yuksel, Gunnar Blohm, Marcus Missal, and Philippe Lefèvre. What triggers catch-up saccades during visual tracking? Journal of Neurophysiology, 87(3):1646–1650, 2002.
[11] Meng-Xi Zhou, Qin Wang, Yin Lin, Qian Xu, Li Wu, Ya-Jing Chen, Yu-Han Jiang, Qing He, Lei Zhao, You-Rong Dong, Jian-Ren Liu, and Wei Chen. Oculomotor impairments in de novo Parkinson's disease. Frontiers in Aging Neuroscience, 14:985679, 2022.
[12] Jolande Fooken, Pooja Patel, Christina Jones, Martin McKeown, and Miriam Spering. Preservation of eye movements in Parkinson's disease is stimulus-and task-specific. The Journal of Neuroscience, 42(3):487–499, 2022.
[13] Bo Zhao, Changshen Yu, Yue Zhang, Miaomiao Yin, Xuan Yang, Change Wang, Peipei Liu, Yang Yu, Yuanyuan Cheng, Zhizhong Zhu, Xiyue Jing, and Jialing Wu. Smooth pursuit eye movements in different directions and frequencies as biomarkers for detecting early-stage Parkinson's disease and assessing levodopa responsiveness: A cross-sectional study. European Journal of Medical Research, 30:1151, 2025.
[14] Ary Goldberger, Chung-Kang Peng, and Lewis Lipsitz. What is physiologic complexity and how does it change with aging and disease? Neurobiology of Aging, 23(1):23–26, 2002.
[15] Chiara Pappalettera, Francesca Miraglia, Maria Cotelli, Paolo Maria Rossini, and Fabrizio Vecchio. Analysis of complexity in the EEG activity of Parkinson's disease patients by means of approximate entropy. GeroScience, 44(3):1599–1607, 2022.
[16] Laureano Moro-Velázquez, Jorge Gómez-García, Julián David Arias-Londoño, Najim Dehak, and Juan Ignacio Godino-Llorente. Advances in Parkinson's disease detection and assessment using voice and speech: A review of the articulatory and phonatory aspects. Biomedical Signal Processing and Control, 66:102418, 2021.
[17] Cristian Pasluosta, Julius Hannink, Heiko Gaßner, Vinzenz von Tscharner, Jürgen Winkler, Jochen Klucken, and Björn Eskofier. Motor output complexity in Parkinson's disease during quiet standing and walking: Analysis of short-term correlations using the entropic half-life. Human Movement Science, 58:185–194, 2018.
[18] Katarzyna Harezlak and Pawel Kasprowski. Understanding eye movement signal characteristics based on their dynamical and fractal features. Sensors, 19(3):626, 2019.
[19] Corina Aştefānoaei, Dorina Creangă, Elena Pretegiani, Lance Optican, and Alessandra Rufa. Dynamical complexity analysis of saccadic eye movements in two different psychological conditions. Romanian Reports in Physics, 66(4):1038–1055, 2014.
[20] Atsuo Murata and Tomoya Matsuura. Nonlinear dynamical analysis of eye movement characteristics using attractor plot and first Lyapunov exponent. In Human-Computer Interaction: Interaction Technologies, 17th International Conference on Human-Computer Interaction, Los Angeles, California, United States, August 2–7, 2015, Proceedings, Part II, pages 78–85. Springer, 2015.
[21] Karen Hampson, Matthew Cufflin, and Edward Mallen. Sensitivity of chaos measures in detecting stress in the focusing control mechanism of the short-sighted eye. Bulletin of Mathematical Biology, 79:1870–1887, 2017.
[22] Mehdi Bejani, Elisa Luque-Buzo, Jorge Gómez-García, Arsen Burlaka-Petrash, Francisco Grandas, and Juan Ignacio Godino-Llorente. Detection of Parkinson's disease by analysis of smooth pursuit eye movements and machine learning. Movement Disorders, 37(Supplement 2):S184–S185, 2022. Conference abstract.
[23] Donald Brien, Heidi Riek, Rachel Yep, Jeff Huang, Brian Coe, Corson Areshenkoff, David Grimes, Mandar Jog, Anthony Lang, Connie Marras, Mario Masellis, Paula McLaughlin, Alicia Peltsch, Angela Roberts, Brian Tan, Derek Beaton, Wendy Lou, Richard Swartz, and Douglas Munoz. Classification and staging of Parkinson's disease using video-based eye tracking. Parkinsonism & Related Disorders, 110:105316, 2023.
[24] Maosong Jiang, Yanzhi Liu, Yanlu Cao, Shufeng Xia, Fei Teng, Wenzhi Zhao, Yongzhong Lin, and Wenlong Liu. Diagnosis of Parkinson's disease by eliciting trait-specific eye movements in multi-visual tasks. Journal of Translational Medicine, 23(1):65, 2025.
[25] Tingting Zhang, Chenhui Pei, Feng Jin, Yifan Zhou, Lina Tan, Jiaojiao Li, Da Wang, Huiling Zhou, and Zhanhua Liang. Exploring eye movement abnormalities as objective biomarkers for Parkinson's disease utilizing virtual reality-based eye tracking. BMC Neurology, 26(1):151, 2026.
[26] Zhiyuan Tan, Jie Zhao, Liwen Kong, Qinfen Song, Qijie Zou, Yana Lv, Shanshan Liang, and Shuai Tao. DP-MDLA Net: Detection of smooth pursuit abnormalities in Parkinson's disease. Digital Health, 12:20552076261421158, 2026.
[27] Mehdi Bejani, Guillermo Perez-de Arenaza-Pozo, Julián David Arias-Londoño, and Juan Ignacio Godino-Llorente. Imputation of missing data in smooth pursuit eye movements using a self-attention-based deep learning approach. IEEE Transactions on Cognitive and Developmental Systems, In press, 2026.
[28] Mehdi Bejani, Elisa Luque-Buzo, Arsen Burlaka-Petrash, Jorge Gómez-García, Julián David Arias-Londoño, Francisco Grandas-Pérez, Jesús Grajal, and Juan Ignacio Godino-Llorente. Baseline wander removal applied to smooth pursuit eye movements from Parkinsonian patients. IEEE Access, 11:32119–32133, 2023.
[29] Elisa Luque-Buzo, Mehdi Bejani, Julián David Arias-Londoño, Jorge Gómez-García, Francisco Grandas-Pérez, and Juan Ignacio Godino-Llorente. Estimation of the cyclopean eye from binocular smooth pursuit tests. IEEE Transactions on Cognitive and Developmental Systems, 16(6):2125–2137, 2024.
[30] Dmitri Kondrashov, Yuri Shprits, and Michael Ghil. Gap filling of solar wind data by singular spectrum analysis. Geophysical Research Letters, 37(15):L15101, 2010.
[31] Norman Packard, James Crutchfield, James Doyne Farmer, and Robert Shaw. Geometry from a time series. Physical Review Letters, 45(9):712–716, 1980.
[32] Floris Takens. Detecting strange attractors in turbulence. In David Rand and Lai-Sang Young, editors, Dynamical Systems and Turbulence, Warwick 1980, volume 898 of Lecture Notes in Mathematics, pages 366–381. Springer-Verlag, Berlin, Heidelberg, 1981.
[33] Andrew Fraser and Harry Swinney. Independent coordinates for strange attractors from mutual information. Physical Review A, 33(2):1134–1140, 1986.
[34] Matthew Kennel, Reggie Brown, and Henry Abarbanel. Determining embedding dimension for phase-space reconstruction using a geometrical construction. Physical Review A, 45(6):3403–3411, 1992.
[35] Matthew Flood and Bernd Grimm. EntropyHub: An open-source toolkit for entropic time-series analysis. PLOS ONE, 16(11):e0259448, 2021.
[36] Dominique Makowski, Tam Pham, Zen Juen Lau, Jan Brammer, François Lespinasse, Hung Pham, Christopher Schölzel, and Annabel Chen. NeuroKit2: A Python toolbox for neurophysiological signal processing. Behavior Research Methods, 53(4):1689–1696, 2021.
[37] Christopher Schölzel. nolds: Nonlinear measures for dynamical systems. Python software package, 2015.
[38] Claude Shannon. A mathematical theory of communication. Bell System Technical Journal, 27(3–4):379–423, 623–656, 1948.
[39] Edwin Thompson Jaynes. Information theory and statistical mechanics. Physical Review, 106(4):620–630, 1957.
[40] Constantino Tsallis. Possible generalization of Boltzmann–Gibbs statistics. Journal of Statistical Physics, 52(1–2):479–487, 1988.
[41] Ralph Vinton Lyon Hartley. Transmission of information. Bell System Technical Journal, 7(3):535–563, 1928.
[42] Alfréd Rényi. On measures of entropy and information. In Proceedings of the Fourth Berkeley Symposium on Mathematical Statistics and Probability, volume 1, pages 547–561. University of California Press, 1961.
[43] Steven Pincus. Approximate entropy as a measure of system complexity. Proceedings of the National Academy of Sciences of the United States of America, 88(6):2297–2301, 1991.
[44] Alberto Porta, Tomaso Gnecchi-Ruscone, Eleonora Tobaldini, Stefano Guzzetti, Raffaello Furlan, and Nicola Montano. Progressive decrease of heart period variability entropy-based complexity during graded head-up tilt. Journal of Applied Physiology, 103(4):1143–1149, 2007.
[45] Joshua Richman and Joseph Randall Moorman. Physiological time-series analysis using approximate entropy and sample entropy. American Journal of Physiology-Heart and Circulatory Physiology, 278(6):H2039–H2049, 2000.
[46] Douglas Lake. Rényi entropy measures of heart rate Gaussianity. IEEE Transactions on Biomedical Engineering, 53(1):21–27, 2006.
[47] Christoph Bandt and Bernd Pompe. Permutation entropy: A natural complexity measure for time series. Physical Review Letters, 88(17):174102, 2002.
[48] Bilal Fadlallah, Badong Chen, Andreas Keil, and José Carlos Príncipe. Weighted-permutation entropy: A complexity measure for time series incorporating amplitude information. Physical Review E, 87(2):022911, 2013.
[49] Anton Unakafov and Karsten Keller. Conditional entropy of ordinal patterns. Physica D: Nonlinear Phenomena, 269:94–102, 2014.
[50] Xiao-Feng Liu and Yue Wang. Fine-grained permutation entropy as a measure of natural complexity for time series. Chinese Physics B, 18(7):2690–2695, 2009.
[51] Chunhua Bian, Chang Qin, Qianli Ma, and Qinghong Shen. Modified permutation-entropy analysis of heartbeat dynamics. Physical Review E, 85(2):021906, 2012.
[52] Hamed Azami and Javier Escudero. Amplitude-aware permutation entropy: Illustration in spike detection and signal segmentation. Computer Methods and Programs in Biomedicine, 128:40–51, 2016.
[53] Zhiqiang Huo, Yu Zhang, Lei Shu, and Xiaowen Liao. Edge permutation entropy: An improved entropy measure for time-series analysis. In Proceedings of the 45th Annual Conference of the IEEE Industrial Electronics Society (IECON 2019), pages 5998–6003. IEEE, 2019.
[54] Zhe Chen, Yaan Li, Hongtao Liang, and Jing Yu. Improved permutation entropy for measuring complexity of time series under noisy condition. Complexity, 2019:1403829, 2019.
[55] Abraham Lempel and Jacob Ziv. On the complexity of finite sequences. IEEE Transactions on Information Theory, 22(1):75–81, 1976.
[56] Michael Katz. Fractals and the analysis of waveforms. Computers in Biology and Medicine, 18(3):145–156, 1988.
[57] Artur Petrosian. Kolmogorov complexity of finite sequences and recognition of different preictal EEG patterns. In Proceedings of the Eighth IEEE Symposium on Computer-Based Medical Systems, pages 212–217. IEEE, 1995.
[58] Alan Wolf, Jack Swift, Harry Swinney, and John Vastano. Determining Lyapunov exponents from a time series. Physica D: Nonlinear Phenomena, 16(3):285–317, 1985.
[59] Peter Grassberger and Itamar Procaccia. Measuring the strangeness of strange attractors. Physica D: Nonlinear Phenomena, 9(1–2):189–208, 1983.
[60] Harold Edwin Hurst. Long-term storage capacity of reservoirs. Transactions of the American Society of Civil Engineers, 116(1):770–799, 1951.
[61] Chung-Kang Peng, Sergey Buldyrev, Shlomo Havlin, Michael Simons, Harry Eugene Stanley, and Ary Goldberger. Mosaic organization of DNA nucleotides. Physical Review E, 49(2):1685–1689, 1994.
[62] Sudhir Varma and Richard Simon. Bias in error estimation when using cross-validation for model selection. BMC Bioinformatics, 7:91, 2006.
[63] Daniël Lakens. Calculating and reporting effect sizes to facilitate cumulative science: A practical primer for t-tests and ANOVAs. Frontiers in Psychology, 4:863, 2013.
[64] Robert Jacobs, Michael Jordan, Steven Nowlan, and Geoffrey Hinton. Adaptive mixtures of local experts. Neural Computation, 3(1):79–87, 1991.
[65] Fabian Pedregosa, Gaël Varoquaux, Alexandre Gramfort, Vincent Michel, Bertrand Thirion, Olivier Grisel, Mathieu Blondel, Peter Prettenhofer, Ron Weiss, Vincent Dubourg, Jake VanderPlas, Alexandre Passos, David Cournapeau, Matthieu Brucher, Matthieu Perrot, and Édouard Duchesnay. Scikit-learn: Machine learning in Python. Journal of Machine Learning Research, 12:2825–2830, 2011.
[66] Miroslav Kubat and Stan Matwin. Addressing the curse of imbalanced training sets: one-sided selection. In Proceedings of the Fourteenth International Conference on Machine Learning, pages 179–186, 1997.
[67] Gavin Cawley and Nicola Talbot. On over-fitting in model selection and subsequent selection bias in performance evaluation. Journal of Machine Learning Research, 11(70):2079–2107, 2010.
[68] Chih-Wei Hsu, Chih-Chung Chang, and Chih-Jen Lin. A practical guide to support vector classification. Technical report, Department of Computer Science, National Taiwan University, Taipei, Taiwan, 2003.
[69] Rehan Akbani, Stephen Kwek, and Nathalie Japkowicz. Applying support vector machines to imbalanced datasets. In Machine Learning: ECML 2004, 15th European Conference on Machine Learning, Pisa, Italy, September 20–24, 2004, Proceedings, volume 3201 of Lecture Notes in Computer Science, pages 39–50. Springer, 2004.
[70] Pabitra Mitra, Chivukula Anjaneya Murthy, and Sankar Kumar Pal. Unsupervised feature selection using feature similarity. IEEE Transactions on Pattern Analysis and Machine Intelligence, 24(3):301–312, 2002.
[71] Ron Kohavi and George John. Wrappers for feature subset selection. Artificial Intelligence, 97(1–2):273–324, 1997.
[72] Peter Bühlmann, Philipp Rütimann, Sara van de Geer, and Cun-Hui Zhang. Correlated variables in regression: Clustering and sparse estimation. Journal of Statistical Planning and Inference, 143(11):1835–1858, 2013.
[73] Alexandros Kalousis, Julien Prados, and Melanie Hilario. Stability of feature selection algorithms: A study on high-dimensional spaces. Knowledge and Information Systems, 12(1):95–116, 2007.
[74] Sarah Nogueira, Konstantinos Sechidis, and Gavin Brown. On the stability of feature selection algorithms. Journal of Machine Learning Research, 18(174):1–54, 2018.
[75] Stephen Johnson. Hierarchical clustering schemes. Psychometrika, 32(3):241–254, 1967.
[76] Leonard Kaufman and Peter Rousseeuw. Finding groups in data: An introduction to cluster analysis. John Wiley & Sons, New York, 1990.
[77] Christophe Ambroise and Geoffrey McLachlan. Selection bias in gene extraction on the basis of microarray gene-expression data. Proceedings of the National Academy of Sciences of the United States of America, 99(10):6562–6566, 2002.
[78] Isabelle Guyon and André Elisseeff. An introduction to variable and feature selection. Journal of Machine Learning Research, 3:1157–1182, 2003.
[79] Nicolai Meinshausen and Peter Bühlmann. Stability selection. Journal of the Royal Statistical Society: Series B (Statistical Methodology), 72(4):417–473, 2010.
[80] John Platt. Probabilistic outputs for support vector machines and comparisons to regularized likelihood methods. In Alexander Smola, Peter Bartlett, Bernhard Schölkopf, and Dale Schuurmans, editors, Advances in Large Margin Classifiers, pages 61–74. MIT Press, Cambridge, MA, 2000.
[81] Josef Kittler, Mohamad Hatef, Robert Duin, and Jiří Matas. On combining classifiers. IEEE Transactions on Pattern Analysis and Machine Intelligence, 20(3):226–239, 1998.
[82] David Wolpert. Stacked generalization. Neural Networks, 5(2):241–259, 1992.
[83] David Cox. Two further applications of a model for binary regression. Biometrika, 45(3–4):562–565, 1958.
[84] Carmen Esposito, Gregory A. Landrum, Nadine Schneider, Nikolaus Stiefl, and Sereina Riniker. GHOST: Adjusting the decision threshold to handle imbalanced data in machine learning. Journal of Chemical Information and Modeling, 61(6):2623–2640, 2021.
[85] Alvin Martin, George Doddington, Terri Kamm, Mark Ordowski, and Mark Przybocki. The DET curve in assessment of detection task performance. In Proceedings of the 5th European Conference on Speech Communication and Technology (Eurospeech 1997), volume 4, pages 1895–1898, 1997.
[86] Edwin B. Wilson. Probable inference, the law of succession, and statistical inference. Journal of the American Statistical Association, 22(158):209–212, 1927.
[87] Scott M. Lundberg and Su-In Lee. A unified approach to interpreting model predictions. In Advances in Neural Information Processing Systems, volume 30, pages 4765–4774, 2017.
[88] Jean-Jacques Orban de Xivry and Philippe Lefèvre. Saccades and pursuit: two outcomes of a single sensorimotor process. The Journal of Physiology, 584(1):11–23, 2007.
[89] Tatiana Amor, Saulo Reis, Daniel Campos, Hans Herrmann, and José Andrade Jr. Persistence in eye
movement during visual search. Scientific Reports, 6:20815, 2016.
[90] José Obeso, Concepción Marin, María Rodriguez-Oroz, Javier Blesa, Beatriz Benitez-Temiño, Juan Mena-Segovia, Manuel Rodríguez, and Charles Warren Olanow. The basal ganglia in Parkinson's disease: Current concepts and unexplained observations. Annals of Neurology, 64(S2):S30–S46, 2008.
[91] Kikuro Fukushima, Norie Ito, Graham Barnes, Sachiyo Onishi, Nobuyoshi Kobayashi, Hidetoshi Takei, Peter Olley, Susumu Chiba, Kiyoharu Inoue, and Tateo Warabi. Impaired smooth-pursuit in Parkinson's disease: Normal cue-information memory, but dysfunction of extra-retinal mechanisms for pursuit preparation and execution. Physiological Reports, 3(3):e12361, 2015.
[92] Lee McIlreavy, Tom Freeman, and Jonathan Erichsen. Two-dimensional analysis of smooth pursuit eye movements reveals quantitative deficits in precision and accuracy. Translational Vision Science & Technology, 8(5):7, 2019.
[93] Frédéric Danion, James Mathew, Niels Gouirand, and Eli Brenner. More precise tracking of horizontal than vertical target motion with both the eyes and hand. Cortex, 134:30–42, 2021.
[94] Kateryna Melnyk, Lee Friedman, and Oleg Komogortsev. What can entropy metrics tell us about the characteristics of ocular fixation trajectories? PLOS ONE, 19(1):e0291823, 2024.
[95] Solveig Dalbro, Ahmed Elsais, Siri Lynne Rydning, Mathias Toft, Emilia Kerty, and Stig Larsen. Repeatability, reliability, and stability of eye movement measurements in Parkinson's disease, cerebellar ataxia, and healthy adults. Frontiers in Neurology, 16:1556314, 2025.
Supplementary results
S1. Preliminary selection of the experimental setting
Table S1: Development set Area Under the Curve (AUC) for Parkinson's disease (PD) classification across the Delay Strategies (DSs) using the gaze position sequences along the X axis. Values are reported as the mean ± standard deviation across the four Experimental Frameworks (EFs).
| DS | Approximate temporal span | All features | Computed from delay vectors | Computed directly from the sequence |
|---|---|---|---|---|
| DS1 | 50–75 ms | |||
| DS2 | approximately 2.20 s | |||
| DS3 | approximately 3.20 s | |||
| DS4 | approximately 1.50 s |
Table S2: Development set AUC for PD classification according to the analysed axis and the eye from which the features were extracted at DS1. Values are reported as the mean ± standard deviation across the four EFs. Separate eyes along the Y axis are not shown; their AUC was close to chance (approximately 0.50).
| Data included at DS1 | All features | Features computed from delay vectors |
|---|---|---|
| Both eyes, X and Y axes pooled | ||
| Both eyes, X axis | ||
| Both eyes, Y axis | ||
| Left eye, X axis | ||
| Right eye, X axis |
Table S3: Changes in the gaze position sequences of the development set produced by Baseline Wander (BW) removal and Cyclopean Eye Residual Movement (CERM) extraction. Relative local variation is the standard deviation of the first differences divided by the standard deviation of the sequence. Values are median paired ratios with 95% confidence intervals; indicates a reduction.
| Statistic | BW removal EF2/EF1 | CERM extraction EF3/EF1 | CERM extraction EF4/EF2 |
|---|---|---|---|
| Standard deviation of the sequence | 0.17 [0.15, 0.19] | — | — |
| Standard deviation of the first differences | 0.97 [0.97, 0.98] | — | — |
| Relative local variation, complete sequence | — | 0.93 [0.92, 0.93] | 0.95 [0.94, 0.95] |
| Relative local variation, 50 ms windows | — | 0.81 [0.81, 0.81] | 0.89 [0.89, 0.90] |
| Windows with | — | 80.88 [79.76, 81.15] | 70.70 [69.06, 71.87] |
Table S4: Representative effect sizes by family at DS1 in the development set. Cohen's was calculated as the difference between the PD and Healthy Control (HC) means divided by the pooled standard deviation. Positive values therefore indicate higher feature values in participants with PD, whereas negative values indicate higher values in HCs. Bold rows identify the measures whose direction reversed after CERM extraction both with and without BW removal.
| Family / representative measure | EF1 | EF2 | EF3 | EF4 |
|---|---|---|---|---|
| Memory and scaling: DFA | -0.39 | -0.19 | -0.26 | -0.24 |
| Memory and scaling: HE | -0.16 | -0.29 | -0.11 | -0.22 |
| Symbolic complexity: LZC | +0.32 | -0.08 | +0.16 | -0.06 |
| Geometric and fractal: PFD | +0.23 | +0.18 | +0.25 | +0.16 |
| Phase space dynamics: LLE | +0.40 | +0.35 | +0.30 | +0.33 |
| Phase space dynamics: CD | +0.06 | +0.19 | -0.30 | +0.08 |
| Informational entropy: PowEn | +0.53 | +0.08 | -0.30 | -0.21 |
| Temporal entropy: SampEn | +0.38 | +0.35 | -0.18 | -0.25 |
| Ordinal and permutation entropy: wPE | +0.78 | +0.65 | +0.53 | +0.61 |
S2. Discriminative ability of the individual base models
Table S5: AUC of the base models by Smooth Pursuit Task (SPT), target movement and axis. Cells report the mean (standard deviation) across the 20 holdouts, followed by the AUC on the external test set. Bold values identify the three highest development values.
| Target: X | SPT1 | SPT2 | SPT3 | SPT4 |
|---|---|---|---|---|
| X axis | 0.77 (0.06) / 0.48 | 0.70 (0.11) / 0.80 | 0.66 (0.15) / 0.80 | 0.82 (0.08) / 0.70 |
| Y axis | 0.47 (0.08) / 0.50 | 0.51 (0.03) / 0.50 | 0.47 (0.07) / 0.50 | 0.53 (0.10) / 0.50 |
| Target: Y | SPT5 | SPT6 | SPT7 | SPT8 |
| X axis | 0.80 (0.15) / 0.75 | 0.52 (0.15) / 0.90 | 0.72 (0.15) / 0.74 | 0.67 (0.11) / 0.79 |
| Y axis | 0.67 (0.15) / 0.64 | 0.53 (0.09) / 0.40 | 0.47 (0.06) / 0.50 | 0.47 (0.07) / 0.50 |
| Target: 2D | SPT9 | SPT10 | SPT11 | SPT12 |
| X axis | 0.74 (0.10) / 0.64 | 0.58 (0.09) / 0.60 | 0.62 (0.06) / 0.71 | 0.66 (0.17) / 0.80 |
| Y axis | 0.55 (0.09) / 0.57 | 0.42 (0.10) / 0.50 | 0.48 (0.05) / 0.50 | 0.49 (0.07) / 0.50 |