arXiv:2610.33554cs.CVOct 2026

Manuscript Offprint

arXiv:2610.33554

End-to-end prostate lesion segmentation and detection from undersampled diffusion-weighted MRI

Lukas T. Rotkopf, Marco Schlimbach, Kevin Kröninger, Stefan O. Schoenberg, Heinz-Peter Schlemmer, Jens Kleesiek, Moritz Rempe

Abstract

Background. Automated prostate lesion detection from diffusion-weighted MR imaging (DWI) conventionally relies on reconstructed images and does not fully use all acquisition information. We present an end-to-end network that uses complex multicoil DWI data and coil sensitivity information for prostate lesion segmentation. We evaluated its robustness to undersampling and added noise, its performance in patient-level detection, and the contributions of data consistency and training strategy.

Methods. We included 269 fastMRI prostate examinations with additional voxel-level lesion annotations based on the released DWI PIRADS scores. Of these, 64 examinations contained PIRADS 4 or 5 lesions. The proposed network, VarNet-Seg, consists of a k-space variational network (VarNet) with six variational cascades and an image-space 3D segmentation U-Net and is trained end to end on complex multicoil b50 and b1000 data. Comparator models used the same segmentation architecture with fully coil-combined images (CC-Seg), fixed root-sum-of-squares reconstruction (RSS-Seg), or fixed SENSE reconstruction (SENSE-Seg). VarNet-Seg (no DC) retained the proposed architecture with data consistency disabled. We performed ablations with end-to-end training and data consistency enabled or disabled. We evaluated lesion segmentation using Dice and patient-level detection using AUROC in five-fold cross-validation with full sampling, simulated undersampling, added noise, or both.

Results. VarNet-Seg achieved the highest Dice at every undersampling level. At eight-fold acceleration, Dice was 0.22 for VarNet-Seg, 0.14 for SENSE-Seg and 0.16 for VarNet-Seg (no DC). The paired difference from SENSE-Seg was 0.08 (95% CI, 0.04–0.11). VarNet-Seg (frozen) and VarNet-Seg (frozen, no DC) achieved Dice of 0.17 and 0.12, respectively, with the matched ablations supporting contributions from both end-to-end training and data consistency. With full sampling, VarNet-Seg and RSS-Seg performed similarly (0.40 vs 0.39). Removing data consistency reduced Dice under acceleration in all training strategies. Patient-level AUROC decreased from 0.75 with full sampling to 0.63 at eight-fold acceleration; corresponding RSS-Seg AUROCs were 0.76 and 0.64. VarNet-Seg inference took 29 ms per volume, compared with 4 ms for SENSE-Seg.

Conclusions. The proposed multicoil network improved prostate lesion segmentation under simulated undersampling compared to conventional models. Matched ablations supported contributions from both end-to-end training and data consistency. Prospective evaluation is needed to establish whether this approach can be used clinically in accelerated prostate DWI.

Keywords: Prostate, Diffusion-weighted MRI, PIRADS, Lesion segmentation, Variational network, Data consistency, Coil compression

Introduction

Prostate cancer is one of the most common cancers in men, and its increasing global burden places growing demands on diagnostic services [1]. Magnetic resonance imaging (MRI) has become central to diagnosis and biopsy planning by identifying suspicious lesions and guiding targeted tissue sampling [2, 3]. However, long examination times and limited scanner capacity constrain access to prostate MRI [4]. Shorter protocols would allow more patients to be examined with existing capacity, provided that they preserve the information needed to detect and localize lesions. For automated lesion assessment, we address the separation of reconstruction and segmentation by training both stages jointly to preserve lesion information under reduced sampling and added noise.

Biparametric protocols already shorten examinations by omitting contrast-enhanced imaging, without loss of diagnostic performance when image quality is adequate [4]. They consist of T2-weighted and diffusion-weighted imaging (DWI), including derived apparent diffusion coefficient maps, which provide the anatomical and diffusion information used in PIRADS assessment [3]. Further reductions in scan time require more efficient acquisition, for example by collecting fewer k-space samples or reducing the number of signal averages. Both make the subsequent reconstruction harder, because images must then be recovered from incomplete or noisier measurements. One common approach, parallel imaging, uses differences in receiver-coil sensitivity to reconstruct undersampled data, but the associated loss of signal-to-noise ratio (SNR) limits acceleration [5, 6].

A similar constraint arises in low-field MRI, where less expensive hardware could broaden access and modern systems are being investigated for prostate imaging [7, 8]. Lower field strength reduces the available MR signal, increasing the relative influence of noise, particularly in high-b DWI where diffusion weighting further attenuates the signal. Additional averaging restores SNR, but at the cost of longer acquisitions [7].

Established approaches to automated prostate lesion assessment from these measurements operate on reconstructed images, with reconstruction and lesion analysis treated as separate tasks [9, 10]. The analysis network thus receives images after coil combination, without direct access to the underlying complex measurements or the ability to influence their reconstruction.

In contrast, training both reconstruction and segmentation simultaneously allows lesion annotations to guide reconstruction, giving both stages a shared objective [11]. Errors in the final segmentation can then influence how the complex diffusion data are combined and refined, so that reconstruction is trained to support lesion delineation. However, improvements in reconstructed image quality do not necessarily translate into better lesion detection [10]. Optimizing reconstruction for the downstream task rather than for image quality addresses this mismatch directly.

Here, we present VarNet-Seg, an end-to-end variational network that combines multicoil DWI reconstruction and 3D prostate lesion segmentation in a single model. Using complex low- and high-b data from the 3 T fastMRI Prostate dataset with additional voxel-level annotations [12], we compare it with segmentation models using fixed RSS or SENSE reconstruction (RSS-Seg and SENSE-Seg), a coil-combined image model (CC-Seg) and VarNet-Seg (no DC), a matched variant with data consistency disabled. Variational networks provide this connection by alternating learned image refinement with data-consistency updates in k-space [13, 14]. These updates relate intermediate image estimates to the retained measurements, allowing learned suppression of aliasing and noise to be guided by the input data.

By evaluating full sampling, simulated undersampling, added noise and their combination, we test how far task-trained reconstruction can sustain lesion analysis as data availability and SNR decrease, and whether improved delineation is accompanied by better patient-level detection.

References (27)