Do Bio-Inspired Algorithms Save Energy in Data Centres? Separating Server Packing from Migration Search in Virtual Machine Consolidation

Yichiet Aun, Yu Hang Woo

Abstract

Energy-efficient virtual machine (VM) consolidation matters as data centre electricity demand rises. Bio-inspired metaheuristics, including ant colony optimisation (ACO), particle swarm optimisation (PSO), and genetic algorithms, have reported substantial energy savings. However, these improvements are commonly evaluated against conventional allocation policies that differ in both initial VM placement and subsequent migration optimisation, making it difficult to determine the contribution of metaheuristic search. This study reproduces an existing consolidation implementation in CloudSim Plus and introduces a matched control that retains the same initial packing and empty-host deactivation mechanisms but excludes migration search. ACO, PSO, and a modified genetic algorithm (MGA) are evaluated across two fleet configurations and four workload regimes, with ten stochastic replications per condition. The matched control achieves energy savings of 0.8–81.4% relative to the spreading baseline, the amount available falling sharply as load rises, without migrations or incomplete workload execution. Across 24 comparisons, metaheuristic search increases energy consumption in 11 cases, produces identical outcomes in seven, and reduces consumption in six. Of these, ten increases and five reductions remain statistically significant after Holm correction. Five of the six apparent reductions coincide with unfinished tasks and disappear after normalisation by delivered computational work. Only ACO under light heterogeneous load retains a 3.22-percentage-point improvement (95% CI 2.96–3.47). These findings demonstrate that initial packing and host deactivation account for most of the measured energy savings in the examined implementations, highlighting the importance of matched control conditions and workload-completion measures for reliable evaluation of VM consolidation algorithms.

Keywords: virtual machine placement; server consolidation; data centre energy; ant colony optimisation; particle swarm optimisation; controlled experiment

1. Introduction

Global data centre electricity consumption reached 415 TWh in 2024 and is projected to approach 945 TWh by 2030 [1]. Efficiency gains at the facility level can no longer absorb this growth, as the industry-weighted Power Usage Effectiveness has remained near 1.54 for six consecutive years [2], indicating that the overhead layer is close to its practical limit. Alternative avenues for optimisation can therefore be explored within the information technology layer itself, where computational work is assigned to physical machines.

Scope for such optimisation arises from the way server power scales with load. A powered but idle host draws between 50% and 70% of its peak demand [3], so a fleet operating at low utilisation consumes a disproportionate share of its rated power. Energy is conserved not by distributing load evenly across the fleet, but by concentrating it onto fewer hosts and deactivating the remainder. Virtualisation makes such concentration possible, and the resulting optimisation problem, virtual machine (VM) consolidation, has become the principal information technology intervention available for data centre energy management.

The scale at which these policies will be applied is growing fastest outside the established markets, and Southeast Asia is where the question is most immediate. In Johor, Malaysia, 38 data centre projects hold Electricity Supply Agreements totalling 5.9 GW of maximum demand against an actual drawn load of 405 MW in December 2024 [4], so contracted demand there exceeds realised demand by more than an order of magnitude. Most of that capacity has yet to be energised, which means that the consolidation policies governing its eventual efficiency remain design decisions rather than installed facts.

VM consolidation is formulated as multi-dimensional bin packing, in which virtual machines with processor, memory and bandwidth requirements are assigned to hosts of finite capacity so as to minimise the number of active hosts. The problem is NP-hard, and its solution space grows combinatorially with fleet size. Exact methods therefore cannot satisfy the timescales required for online allocation, while constructive heuristics such as first-fit and best-fit execute in near-linear time but leave capacity stranded in fragments too small to allocate.

Bio-inspired metaheuristics occupy the interval between these extremes. They require no gradient information, operate directly on discrete assignment spaces, and return a usable solution at any point at which they are interrupted, which suits an allocator that must respond within a scheduling interval. Their population-based structure further allows several candidate configurations to be maintained and compared within a single iteration, providing a mechanism for escaping the local optima that greedy packing produces. Three families have dominated this literature, and each corresponds to a different structural feature of the problem. Ant colony optimisation constructs assignments incrementally and retains a pheromone memory across iterations, which suits a problem in which virtual machines are allocated in sequence and earlier decisions constrain later ones [5]. Particle swarm optimisation represents a complete allocation as a position vector and converges rapidly, although host indices are categorical and must be recovered through discretisation [6]. Genetic algorithms recombine parent solutions through crossover, an operator capable of preserving well-packed groups of virtual machines as intact units, and therefore well matched to grouping problems [7].

Bio-inspired algorithms have been reported to reduce energy consumption by as much as 47% relative to conventional allocation policies [8,11], with others in the same line reporting gains below 15% [5,10]. Those policies, however, differ from the proposed methods in two respects simultaneously: the rule governing where virtual machines are initially placed, and the presence of a subsequent search for beneficial migrations. Only the second is contributed by the metaheuristic, and a comparison that varies both cannot determine which is responsible for the observed saving.

This study develops and applies a controlled experimental framework that distinguishes the energy effect of initial consolidation from the effect attributable to metaheuristic search, and evaluates whether reported improvements persist under matched initial conditions and workload-delivery requirements. An existing consolidation implementation of ant colony optimisation, particle swarm optimisation and a modified genetic algorithm is reproduced in CloudSim Plus and evaluated against a matched control that applies the same initial packing rule and the same empty-host deactivation behaviour, but performs no migration search. An artificial bee colony implementation is carried through the same design as a structural diagnostic. The contrast between the conventional baseline and this control measures the effect of packing and deactivation;

the contrast between the control and each metaheuristic measures the effect of search. Cryptographic fingerprints verify that all policy arms receive identical virtual machine sets and task assignments, so that neither contrast is confounded by workload variation. Energy is reported alongside workload completion throughout, which allows apparent reductions obtained by leaving tasks unfinished to be identified rather than credited. The framework is applied across two fleet configurations and four workload regimes, and three implementation-level properties of the reproduced system are documented where they bear on the interpretation of published results.

The remainder of this paper is organised as follows. Section 2 examines the comparison structure of representative studies. Section 3 specifies the system model and the decomposition. Section 4 describes the controlled framework and the measured implementation. Section 5 details the experimental design. Section 6 reports the results, Section 7 discusses them, and Section 8 concludes.