arXiv:2610.34218cs.CVOct 2026

Manuscript Offprint

arXiv:2610.34218

From Presence Labels to Bounding Boxes: Can Multimodal Large Language Models Scale Surgical Instrument Localization?

Mohamed Hamdy, Muraam Abdel-Ghani, Fatmaelzahraa Ahmed, Sifna Nasar, Mariam Ahmed, Khalid Al-Jalham, Abdulaziz Al-Ali, Shidin Balakrishnan

Mohamed Hamdy 1^{1}, Muraam Abdel-Ghani 2^{2}, Fatmaelzahraa Ahmed 2^{2}, Sifna Nasar 1^{1}, Mariam Ahmed 3^{3}, Khalid Al-Jalham 2^{2}, Abdulaziz Al-Ali 1^{1}, and Shidin Balakrishnan ∗2^{*2}

1^{1} Department of Computer Science and Engineering, Qatar University, Doha, Qatar

2^{2} Hamad Medical Corporation, Doha, Qatar

3^{3} College of Medicine, Qatar University, Doha, Qatar

Abstract. Spatial localization of surgical instruments through bounding-box annotations is a foundational component of surgical scene understanding, supporting detection, tracking, interaction analysis, and grounded vision-language applications. Yet existing annotations often cover selected frames, video subsets, or dataset variants rather than complete procedures. Manual extension is time-consuming and expert-dependent. Additionally, weakly supervised and detector-based pseudo-labels require task-specific training and may be imprecise. In this study, we design a scalable MLLM-based annotation framework that converts surgical frames and existing instrument-presence labels into accurate bounding boxes, and systematically analyze its reliability, cost, and design sensitivity. We instantiate the framework using six MLLMs and a multi-call configuration on laparoscopic cholecystectomy in Cholec80. Using a carefully designed stratification scheme, two annotators independently label 1,000 frames, and an expert surgeon reviews one annotation set to establish the reference. Results show that instrument-set F1 ranges from 88.2 to 92.7, whereas mIoU ranges from 0.180 to 0.735, showing that comparable recognition can conceal large localization differences. A structured multi-stage annotation pipeline achieves 0.784 mIoU, compared with 0.735 for the best single-call baseline and 0.814 human-human agreement. Using the best accuracy pipeline, we create and publicly release a spatial extension of Cholec80 comprising 285,977 bounding boxes across all 184,498 annotated frames from the 80 videos. The annotations and human references are made available on GitHub 4^{4}.

Keywords: Surgical Understanding · Multimodal large language models · Minimally Invasive Surgery · Cholecystectomy

4^{4} https://github.com/M-Hamdy-M/SurgBox

M. Hamdy et al.

1 Introduction

Minimally invasive surgery (MIS) has become widely adopted over the past decades due to its association with faster recovery and reduced intraoperative blood loss [11]. The endoscopic cameras utilized in MIS generate continuous video documentation of anatomy, tools, activities, and workflow, supplying extensive data for computer vision systems [2,6,5]. Models have advanced from coarse phase and instrument detection [13] to fine-grained tasks like instrument detection, segmentation [3,4,1], and action triplet recognition [8,9]. Recently, large vision-language models have enabled surgical visual question answering and multimodal scene understanding [15,16]. However, these detailed tasks often require spatially grounded annotations, which are much harder and more expensive to obtain than simple frame-level labels.

The availability of spatial supervision has not kept pace with the expansion of surgical video understanding. In laparoscopic cholecystectomy, Cholec80 provides phase and instrument-presence annotations yet instance-level localization is absent [13], and its widely used VQA extension, Cholec80-VQA, similarly contains question-answer supervision without visual grounding [12]. This limitation persists in recent multimodal resources. although Surg-396K introduced grounded surgical conversations through EndoChat, its Cholec80-derived component inherits the non-grounded Cholec80-VQA annotation. Therefore it is used only for non-spatial question answering [14]. Dedicated localization datasets provide stronger spatial supervision but remain limited in coverage or annotation granularity. CholecT50 provides instrument-tip bounding boxes for five videos and six instrument classes [10], leaving its spatial coverage more limited than the full Cholec80 dataset. Endoscapes provides bounding-box annotations for 1,933 sparsely sampled frames drawn from the critical view of safety (CVS) regions of 201 MIS cholecystectomy videos, with instruments represented as a single generic tool class [7]. Thus, existing resources support either large-scale semantic supervision or small-scale spatial supervision, leaving a gap in dense, instance-level localization.

We therefore investigate whether current MLLMs can generate accurate instrument bounding boxes under these conditions, whether semantic recognition is indicative of localization quality, and whether decomposing the annotation task into simpler stages improves reliability.

To address these questions, we construct a 1,000-frame human reference spanning all 80 Cholec80 procedures. Each frame is independently annotated by two annotators, and one annotation set is subsequently reviewed by an expert surgeon. Using this reference, we evaluate the ability of six contemporary MLLMs to transform Cholec80's frame-level instrument-presence labels into class-specific, instance-level bounding boxes. We compare a direct single-call protocol with a structured workflow that separates instrument-set identification, instance counting, localization, and bounding-box refinement.

Our main contributions are:

– We construct a validated 1,000-frame human reference spanning all 80 Cholec80 videos, with two independent annotation passes and expert-surgeon review, enabling measurement of human–human spatial agreement.

– We benchmark six contemporary MLLMs for converting weak frame-level instrument supervision into class-specific instance-level bounding boxes.

– We develop a structured multi-stage annotation workflow and release SurgBox, containing 285,977 bounding boxes over all 184,498 annotated Cholec80 frames.

– We demonstrate the downstream utility and transferability of SurgBox by benchmarking eight detectors trained exclusively on MLLM-generated boxes and evaluating cross-dataset generalization to independently annotated CholecSeg8k, where SurgBox supervision achieves 0.833 mAP and reaches 0.866 mAP with subsequent in-domain fine-tuning.

References (16)