ABSTRACT
Despite advances in automated liver lesion segmentation, a gap remains between image-derived predictions and clinically interpretable radiology reports. Bridging this gap requires quantitative measurements that are both reproducible and traceable. We present an evidence-grounded agentic AI framework that connects liver and lesion segmentation with deterministic quantification and structured reporting. TotalSegmentator-based nnU-Net models delineate the liver, Couinaud segments, and lesions, while computational tools extract volumes, dimensions, counts, and anatomical locations. A large language model (LLM) organizes these measurements into a predefined reporting schema, with numerical consistency checks against source measurements. On 51 LiTS cases, the segmentation stage achieved a liver Dice score of 0.947, lesion sensitivity of 75.6%, and positive predictive value of 68.9%. Exploratory screening of 25,494 MERLIN reports identified 10,208 (40.0%) with liver-related abnormalities. By connecting quantitative imaging evidence with agentic report generation, this work takes a step toward human-centered medical AI that prioritizes traceability and clinical relevance.
Index Terms—Liver lesion segmentation, agentic AI, biomedical imaging, structured radiology reporting, evidence-grounded AI.
I. INTRODUCTION
Quantitative assessment of liver lesions in computed tomography (CT) is essential for treatment planning and disease monitoring. Radiologists evaluate lesion size, volume, and anatomical location to assess disease progression and treatment response. However, manual delineation and measurement remain time-consuming and subject to observer variability.
Recent advances in deep learning have enabled automated liver and lesion segmentation using frameworks such as nnU-Net [1] and TotalSegmentator [2]. Related studies have explored Couinaud segment delineation [5] and semi-automated lesion quantification with structured reporting [6]. Despite these advances, integrating segmentation-derived measurements into structured reports while preserving their traceability remains an important challenge. This is particularly relevant to large language models (LLMs), which may generate numerical findings unsupported by image-derived evidence.
To address this challenge, we propose an evidence-grounded agentic AI framework that integrates liver lesion segmentation, deterministic quantitative analysis, and structured radiology reporting. The framework derives lesion measurements and anatomical locations from volumetric masks, while an LLM agent organizes these findings into a predefined reporting schema. Numerical consistency checks link reported values to their computational sources, supporting transparent and radiologist-reviewable reporting.
The main contributions are:
• An integrated agentic workflow connecting automated liver segmentation, quantitative analysis, and structured radiology reporting.
• A deterministic measurement pipeline with numerical consistency checks to support traceable reporting of lesion characteristics.
• An experimental assessment of segmentation and lesion detection on LiTS, complemented by exploratory screening of liver-related findings in MERLIN reports.
The source code is publicly available at https://github.com/Xfatmaah/AI-Assisted-Liver-Lesion-Segmentation-for-Structured-Radiology-Reporting, and a demonstration video is available at https://www.youtube.com/watch?v=4Wm3c_QAp38.
II-A. Liver Segmentation and Quantitative Analysis
The self-configuring nnU-Net framework [1] and TotalSegmentator [2], [3] have advanced automated anatomical segmentation in CT and MRI. Nicoli et al. [4] extended these approaches to liver segments and lesions, including quantitative assessment of hepatocellular carcinoma. The LiTS benchmark [7] provides a reference for liver and tumor segmentation evaluation. Automated Couinaud delineation [5] and semi-automated HCC quantification [6] further demonstrate the role of segmentation in quantitative liver assessment.
AI-Powered CT Liver Analysis and Reporting System

Fig. 1: Overview of the proposed agentic AI workflow
II-B. LLM-Assisted Radiology Reporting
Recent studies have explored LLM-based structured radiology reporting [10], [11], [12], evidence-driven report generation [13], uncertainty-aware labeling [14], and interpretable report evaluation [15]. These approaches address report generation, evidence integration, and assessment from different perspectives.
Building on these advances, our work integrates segmentation-derived quantitative measurements with constrained LLM-based report composition. Unlike direct numerical generation by an LLM, measurements are computed using deterministic tools and checked against their source outputs. The contribution lies in this integrated, traceable workflow rather than a new segmentation model or reporting algorithm.
III. PROPOSED APPROACH
III-A. System Architecture Overview
The proposed framework follows a five-stage agentic workflow, as illustrated in Fig. 1.
To reduce unsupported numerical generation, the LLM-based report composer operates on outputs from deterministic measurement tools rather than estimating quantities directly from CT images. Each reported measurement is linked to its computational source, enabling verification and radiologist review.
Liver — case 4, slice 462 (red = model prediction)
Lesion — case 4, slice 462 (red = model prediction)

Fig. 2: Representative CT segmentation masks illustrating the delineated liver and lesions.
III-B. Segmentation Stage
Contrast-enhanced CT scans are processed using pre-trained nnU-Net models from the TotalSegmentator framework. The models generate segmentation masks for the liver parenchyma, individual Couinaud anatomical segments, and focal hepatic lesions.
III-C. Deterministic Extraction Tools
A Python-based computational layer extracts quantitative measurements from the predicted three-dimensional segmentation masks:
-
Liver and segment volumes: Computed from voxel counts and physical voxel spacing as , where spacing is expressed in mm.
-
Lesion volumes: Total and individual lesion volumes are computed using the same volumetric formula.
-
Lesion count: Determined through 3D connected-component labeling of lesion masks.
-
Lesion dimensions: Estimated from the X-, Y-, and Z-axis extents of each lesion's bounding box (mm), rather than true Feret diameters.
-
Couinaud localization: Each lesion is assigned to the anatomical segment with the largest mask overlap.
The extraction tools are exposed to the agent through a lightweight FastAPI backend.
III-D. Diagnostic Findings from RADAR
For each CT scan, RADAR estimates probabilities for 18 selected liver-related findings from its 146 supported categories [16]. These predictions provide supplementary diagnostic context alongside segmentation-derived measurements but do not modify the computed quantitative values.
III-E. Evidence-Grounded Report Generation and Verification
The LLM agent receives structured measurement data in JSON format and accesses predefined API tools. Report generation follows a fixed schema containing study metadata, anatomical locations, volumetric measurements, linear dimensions, and fields for longitudinal changes.
Two verification steps are applied: (i) schema validation to check output structure and (ii) numerical consistency checking against the source measurement JSON. Values without a corresponding computational source are flagged for review. These checks establish numerical traceability but do not validate segmentation accuracy. Longitudinal fields are retained in the schema but are not evaluated because serial CT examinations are unavailable.
III-F. Radiologist Review Interface
The structured report is displayed alongside segmentation overlays aligned with axial CT slices. The interface allows radiologists to inspect image-derived findings, review measurements, and modify the report before final approval.
IV. EXPERIMENTAL SETUP
• Datasets: The LiTS dataset [7] was used to evaluate liver and lesion segmentation on 51 CT cases. MERLIN radiology reports were used for exploratory screening of liver abnormalities.
• Evaluation Metrics: Segmentation was assessed using the Dice similarity coefficient (DSC). Lesion detection
Liver — case 4, slice 463 (green=GT, red=pred)
Lesion — case 4, slice 463 (green=GT, red=pred)

Fig. 3: Representative LiTS CT segmentation overlay showing ground-truth-only regions (green) and prediction-only regions (red).
was evaluated using sensitivity, positive predictive value (PPV), and false positives per case (FP/c).
• Baseline Comparison: Results were compared with published findings from Nicoli et al [4]. Differences in evaluation cohorts and protocols limit direct comparability.
• Reporting Evaluation: The reporting prototype incorporates numerical consistency checks against computed measurements. Reporting accuracy and clinical usability were not quantitatively evaluated.
V. RESULTS
V-A. Segmentation Performance
All 51 evaluated LiTS cases passed the orientation sanity check and were successfully processed, with no flagged or failed cases. Fig. 3 illustrates a representative comparison between predicted and reference liver and lesion masks.
The overlay highlights regions of agreement and disagreement, providing a qualitative assessment of segmentation boundaries. The segmentation stage achieved a liver Dice coefficient of 0.947, indicating substantial spatial overlap with reference annotations. Lesion segmentation was more challenging, with a reported Dice score of 0.63.
V-B. Lesion Detection Performance
Table I summarizes lesion-level performance alongside the published results of Nicoli et al. [4]. The evaluated model achieved a lesion sensitivity of 75.6%, PPV of 68.9%, and 0.70 false positives per case. Compared with the published reference, sensitivity was 9.9 percentage points higher (75.6% versus 65.7%), while PPV was 11.27 percentage points lower (68.9% versus 80.17%). False positives per case were similar (0.70 versus 0.73).
These results indicate a trade-off between lesion detection sensitivity and precision. Although more reference lesions were detected proportionally, a smaller proportion of predicted lesions corresponded to reference findings. Because the evaluation cohorts and protocols were not identical, these
Table I: Lesion detection and segmentation results on LiTS. Published reference values are from Nicoli et al. [4]; results are not from a paired evaluation.
| Metric | Nicoli et al. [4] | Ours |
|---|---|---|
| Lesion sensitivity (%) | 65.7 | 75.6 |
| PPV (%) | 80.17 | 68.9 |
| FP per case | 0.73 | 0.70 |
| Lesion Dice | 0.59 | 0.63 |

Fig. 4: Comparison of lesion detection and segmentation metrics with the published reference results [4]. Differences are descriptive and do not represent a controlled comparison.
differences should not be interpreted as evidence of superior model performance.
V-C. Exploratory Report Screening
The report-screening stage processed 25,494 MERLIN radiology reports and identified 10,208 (40.0%) as containing liver-related abnormalities. These findings describe the distribution of predicted screening outcomes. Classification accuracy cannot be established without comparison against independently verified labels.
VI. DISCUSSION
The LiTS results indicate reliable liver segmentation, while lesion detection remains more challenging, as reflected in the sensitivity–PPV trade-off. These findings support the use of automated segmentation as the imaging foundation of the proposed framework. The primary contribution lies in connecting these outputs to deterministic lesion quantification and evidence-grounded structured reporting, with numerical verification designed to preserve measurement traceability.
The current evaluation is limited to 51 LiTS cases, with published results used for reference rather than direct comparison. Future work will extend evaluation to larger, matched cohorts, assess measurement accuracy against reference annotations, and quantify reporting consistency and radiologist usability. These investigations will establish the extent to which the integrated workflow can support reproducible quantitative radiology reporting.
VII. CONCLUSION
This work presents an evidence-grounded agentic AI framework that connects automated liver and lesion segmentation with quantitative analysis and structured radiology reporting. The LiTS evaluation demonstrates the performance of the underlying segmentation stage, while the proposed architecture separates image-derived measurements from LLM-based report composition. By integrating deterministic measurement tools, numerical consistency checks, and radiologist review, the framework provides a traceable approach to organizing quantitative imaging findings. Future work will validate measurement accuracy, reporting consistency, and clinical usability to assess its potential for reliable, human-supervised radiology workflows.
ETHICS STATEMENT
This study uses publicly available, de-identified LiTS and MERLIN datasets and involves no new patient data collection or re-identification. No additional institutional ethical approval was required. The proposed system is a research prototype intended for radiologist-supervised decision support, not autonomous diagnosis or clinical deployment.
VIII. REFERENCES
[1] F. Isensee, P. F. Jaeger, S. A. A. Kohl, J. Petersen, and K. H. Maier-Hein, “nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation,” Nature Methods, vol. 18, pp. 203–211, 2021.
[2] J. Wasserthal et al., “TotalSegmentator: Robust segmentation of 104 anatomic structures in CT images,” Radiology: Artificial Intelligence, vol. 5, no. 5, e230024, 2023.
[3] T. Akinci D'Antonoli et al., “TotalSegmentator MRI: Robust sequence-independent segmentation of multiple anatomic structures in MRI,” Radiology, vol. 314, no. 2, e241613, 2025.
[4] A. P. Nicoli et al., “Liver Segment and Lesion Segmentation on CT and MRI: An Open-Source Contribution to TotalSegmentator,” Journal of Imaging Informatics in Medicine, 2025.
[5] T. S. Mathai et al., “Automated Delineation of Couinaud Segments at CT for Future Liver Remnant Volumeetry,” Radiology: Artificial Intelligence, vol. 8, no. 4, e250808, 2026.
[6] A. Jöbstl et al., “Enhancing LI-RADS Through Semi-Automated Quantification of HCC Lesions,” Journal of Personalized Medicine, vol. 15, no. 9, p. 400, 2025.
[7] P. Bilic, P. Christ, H. B. Li et al., “The Liver Tumor Segmentation Benchmark (LiTS),” Medical Image Analysis, vol. 84, p. 102680, 2023.
[8] “Automatic segmentation of liver structures in multi-phase MRI using variants of nnU-Net and Swin UN-ETR,” Scientific Reports, 2025.
[9] “Deep learning for automatic segmentation of hepatocellular carcinoma in contrast-enhanced CT scans,” Scientific Reports, 2025.
[10] F. Busch, L. Hoffmann, D. P. Dos Santos et al., “Large language models for structured reporting in radiology: past, present, and future,” European Radiology, vol. 35, no. 5, pp. 2589–2602, 2025.
[11] J.-B. Delbrouck, J. Xu, J. Moll et al., “Automated Structured Radiology Report Generation,” arXiv preprint arXiv:2505.24223, 2025.
[12] “Automated Structured Radiology Report Generation with Rich Clinical Context (C-SRRG),” arXiv preprint arXiv:2510.00428, 2025.
[13] “EviAgent: Evidence-Driven Agent for Radiology Report Generation,” arXiv preprint, 2025.
[14] “Agent-Based Uncertainty Awareness Improves Automated Radiology Report Labeling with an Open-Source Large Language Model,” arXiv preprint arXiv:2502.01691, 2025.
[15] “Clinically Grounded Agent-based Report Evaluation (ICARE): An Interpretable Metric for Radiology Report Generation,” arXiv preprint arXiv:2508.02808, 2025.
[16] Q. Zhang et al., “An expert-level generalist AI for abdominal CT diagnosis,” Science, 2026, doi:10.1126/science.aec6129.