Manuscript Offprint

arXiv:2610.35092

Uncertainty Evaluation to Support Safety of the Intended Functionality Analysis for Determining the Applicability of Performance Targets Across Triggering Conditions in ML-Based LiDAR Object Detection

Milin Patel, Rolf Jung

Milin Patel 1^{1}[0000-0002-8357-6018] and Rolf Jung 2^{2}[0000-0002-0366-4844]

1^{1} Institute for Driver Assistance and Connected Mobility,

Kempten University of Applied Sciences, Benningen, Germany

2^{2} Faculty of Computer Science,

Kempten University of Applied Sciences, Kempten, Germany

{milin.patel, rolf.jung}@hs-kempten.de

Abstract. For safety of the intended functionality (SOTIF) analysis according to ISO 21448, a machine learning object detector for light detection and ranging (LiDAR) point clouds can meet a performance target, a limit on the mean per-frame share of wrong detections among accepted detections, by rejecting detections above an uncertainty threshold. A threshold selected on data of one condition carries a statistical guarantee only for data distributed like its selection data, whereas SOTIF analysis covers every triggering condition. This paper presents an uncertainty evaluation in which the threshold is transferred into a triggering condition, a test decides at a stated error probability whether the target is applicable there, not applicable or not determined, and a lower bound counts the independent units an applicable outcome requires. For PointPillars ensembles on KITTI and nuScenes, counted in recorded sequences, as the dependence between frames requires, neither dataset held enough independent units for any target limit, and no transfer had a not applicable outcome. Counted in frames, the same data gave not applicable outcomes at limits fixed in advance after transfers into far distance, into rain and between two separately trained detectors, thresholds that met the target limit after a transfer rejected most correct detections, and in rain the area under the receiver operating characteristic curve did not decrease. A performance target met under one condition therefore counts as evidence under a triggering condition only after a test there, reported with its share of accepted correct detections and its number of independent recorded sequences.

Keywords: Safety of the intended functionality · Performance targets · Triggering conditions · Uncertainty thresholds · Learn then Test · LiDAR object detection

1 Introduction

An automated vehicle perceives its surroundings with object detectors, among them detectors for point clouds from light detection and ranging (LiDAR) sensors. A detector based on machine learning (ML) outputs a three-dimensional box, called a detection, for each object that it recognises in a frame, one point cloud of the sensor. The motion

M. Patel and R. Jung

planner, which plans the path and speed of the vehicle, acts on these detections. This paper considers detections of cars, the object class with the most annotations in the KITTI and nuScenes datasets used here [1,2]. A detection is wrong if it does not match a car marked by the annotators of the dataset (an annotated car), for example because no object lies in its box or because the box misses the position or size of the car. A wrong detection can make the vehicle brake or steer for an object that does not exist, or misjudge the position of one that does.

ISO 21448, the standard on the safety of the intended functionality (SOTIF), requires that the residual risk of a driving function meets acceptance criteria at vehicle level [3]. Performance targets for system elements, for example a limit on how often a sensor reports an object that does not exist, can be derived from these criteria. A detector can meet such a target by rejecting uncertain detections. In this paper, the detector is an ensemble of separately trained networks, called members, and two indicators compute the uncertainty of a detection from the outputs of the members. The spatial indicator usu_{s} grows as the members disagree more on the position and size of the box, and the existence indicator ueu_{e} grows as their confidence that an object is present falls. A detection whose indicator value exceeds the uncertainty threshold τ\tau is rejected and does not reach the motion planner. The other detections are accepted. The performance target of this paper bounds the false acceptance proportion (FAP), the share of wrong detections among the accepted detections of a frame averaged over frames, by a limit α\alpha. A lower threshold rejects more wrong detections but also more correct ones, and every rejected correct detection is a car that the motion planner does not receive.

Learn then Test (LTT) selects a threshold on recorded data so that the FAP does not exceed α\alpha with probability at least 1−δ1 - \delta, where δ\delta is a chosen error probability [4]. LTT makes no assumption about the form of the data distribution, but it assumes that the recorded units, for example frames, are independent draws from one distribution. The guarantee therefore holds only for data distributed like the data on which the threshold was selected [5,6], with their mix of distances, weather and locations.

ISO 21448 describes a triggering condition (TC) as a specific condition of a scenario that initiates a system reaction contributing to a hazardous behaviour, and it requires the response of the system to TCs to be evaluated. Its example of a statistical argument (Clause C.6.3.2) assumes one environment and does not state what holds in another. ISO/PAS 8800 considers the case in which the safety requirements of an artificial intelligence system are fulfilled only for a limited part of the input space. It requires that such a case is identified and reported to the development of the encompassing system [7]. A SOTIF analysis therefore has to establish under which conditions a performance target is met. Whether a threshold selected under one condition meets the target under another has to be tested.

The conference paper extended here [8] reported the area under the receiver operating characteristic (ROC) curve (AUROC). AUROC measures how well an indicator separates correct from wrong detections (0.5 is chance level, 1 is perfect separation), not whether a threshold meets a limit. It is therefore not known whether AUROC shows a change of condition under which the threshold no longer meets the limit.

Recorded data can show that a limit is met only if they hold enough independent units (frames or recorded sequences). Frames of one recorded sequence, a continuous recording such as a nuScenes scene or a KITTI drive, are not independent of each other. The number of independent frames or recorded sequences needed to show that a limit is met sets the minimum amount of data to record per condition.

In the uncertainty evaluation of this paper, a statistical test, the applicability test, decides whether a performance target met under one condition is also met under another condition. A threshold is transferred when it is selected on recorded data of one condition, the condition of selection, and used unchanged on recorded data of another, the condition of use. For example, a threshold selected on the detections at near distance is transferred when it is used unchanged on the detections at far distance. At a stated error probability, the performance target is applicable in the condition of use if the data show that the FAP with the transferred threshold does not exceed the limit there, and not applicable if they show that it exceeds the limit. The applicability is not determined if the data show neither. The test examines whether the target is met under the condition of use, not whether it is required there. This paper takes the target as required under every condition of the operational design domain (ODD). Figure 1 shows, for two transfers, one recorded frame in which the transferred threshold accepts a wrong detection that the threshold selected in the condition of use rejects. Both frames were chosen to show this case. In the KITTI frame, an unannotated object under the box of the wrong detection cannot be excluded.

References (40)