Manuscript Offprint

arXiv:2608.24436

Evaluating Deep Multivariate Imputation Models on Wearable Device Data

Skye Goodman, Roussel Desmond Nzoyem, Leandro Junges, Peter Kissack, Yasser Qureshi, Amberly Brigden, Jeff Clark, Nawid Keshtmand

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Skye Goodman 1^{1}, Roussel Desmond Nzoyem 1,2^{1,2}, Leandro Junges 1,3^{1,3}[0000-0003-1536-3579], Peter Kissack 3^{3}, Yasser Qureshi 3^{3}, Amberly Brigden 1^{1}, Jeff Clark 1^{1}[0000-0003-0118-3999], and Nawid Keshtmand 1^{1}[0009-0008-5552-1395]

1^{1} School of Engineering Mathematics and Technology, University of Bristol, UK

2^{2} Centre for AI Fundamentals, University of Manchester, UK

3^{3} Centre for Systems Modelling and Quantitative Biomedicine, University of Birmingham, UK

nawid.keshtmand@bristol.ac.uk

Abstract. Wearable device data enables continuous health monitoring, but suffers from structured missingness: features sharing a physical sensor drop out together. Deep imputation methods such as BRITS and SAITS have seen limited evaluation on multimodal physiological data under realistic missingness, and existing benchmarks use random-point holdout protocols that incorrectly assume missingness is independent across features and time. Using data from a person with epilepsy recorded on a Garmin smartwatch, we develop an evaluation protocol that mines contiguous missing-run templates from training data, stratifies them by per-feature gap-length quantiles, and injects them as block masks with preserved co-missingness structure. A matched training protocol exposing models to the same missingness distribution reduces BRITS's severe-gap MAE by 43%, demonstrating the potential benefit of the proposed evaluation and training protocol within this single-participant dataset. We further extend BRITS with time-of-day encoding and a circadian harmonic channel. No single model dominates: linear interpolation is optimal for slow-moving features over short gaps; extended BRITS achieves lower MAE on dynamic cardiac features in moderate and severe gaps; and SAITS better preserves the ground-truth distribution by Jensen-Shannon distance despite higher MAE. Ultimately, model rankings strongly depend on evaluation designs. By exposing how traditional evaluation methods obscure true model capabilities, our transferable protocol establishes critical steps towards developing better imputation strategies for future multi-sensor wearable datasets.

Keywords: Time Series · Imputation · BRITS · SAITS · Wearables

1 Introduction

Wearable devices such as smartwatches have moved from consumer wellness into longitudinal clinical monitoring, with the global wearable medical device market projected to exceed USD 200 billion by 2035 [1]. A prominent application is

S. Goodman et al.

epilepsy management, which affects over 50 million people worldwide [2] and carries a sudden unexpected death risk of around 1 in 1,000 per year [3]. Seizure-risk forecasting, which predicts an individual's likelihood of a future seizure, offers a potential way to alleviate the anxiety and loss of independence caused by their unpredictable nature [4]. Recent work has demonstrated the feasibility of training such models on non-invasive multimodal wearable data [5], with performance comparable to intracranial-EEG benchmarks [6].

This progress, however, depends on a precondition the field has largely side-stepped: missingness in the training data, often due to sensor failures, poor skin contact, and connectivity dropouts [7]. Time series imputation, which confronts this challenge by replacing missing values with plausible surrogates, is a critical preprocessing step that directly shapes what downstream models can learn. Driven by the rise of deep learning, this area has experienced a surge in research interest, enabling numerous healthcare successes [8,9]. That said, key questions on how to realistically evaluate imputation strategies remain largely unresolved.

State-of-the-art (SOTA) deep imputation methods such as BRITS [10] and SAITS [11] have been benchmarked predominantly under a random-point hold-out protocol, which uniformly removes a fixed proportion of observed values and implicitly assumes missingness is independent across features and time. On wearable data, this assumption fails as features sharing a physical sensor commonly drop out together for sustained intervals, and gap-length distributions vary by orders of magnitude across channels. Such methodological failures leave the community unable to gauge the true capabilities of these models, thus stifling the development of stronger imputation strategies to support patients. Details of various imputation approaches are discussed further in Appendix A. Although recent diffusion-based methods have demonstrated strong performance [12], they typically incur substantially higher computational cost. Accordingly, this work focuses on evaluating widely used recurrent (BRITS) and transformer-based (SAITS) architectures under a realistic wearable missingness protocol rather than providing an exhaustive comparison of all deep imputation methods.

Using physiological signals recorded from a Garmin smartwatch worn by a person with epilepsy [13], this paper makes three contributions to improve the training and evaluation of SOTA imputation methods for wearable devices:

  1. A wearable-realistic evaluation protocol that mines contiguous missing-run templates from training data, stratifies them by per-feature gap-length quantiles into typical/moderate/severe buckets, and injects them as block masks with preserved co-missingness structure.

  2. A matched training schedule exposing BRITS and SAITS to the same missingness distribution at training and evaluation, with a severity curriculum. This reduces BRITS's severe-bucket MAE by 43% over its original training objective.

  3. A temporal context extension for BRITS comprising sine–cosine time-of-day encodings and per-feature 24-hour circadian harmonic channels refitted weekly, reducing heart-rate MAE by 11% and sleep MAE by 29% under severe missingness.

Table 1. Contiguous missing-run length statistics per feature, computed on the training set. A “missing run” is defined as one or more consecutive missing timestamps for a given feature. Run length is measured as the number of consecutive missing timestamps in the run. #Runs reports the total number of missing episodes in the training data. P50P_{50}, P75P_{75} and P90P_{90} denote the 50th, 75th and 90th percentiles of run length LL, and Max denotes the longest observed run in the training set.

FeatureDescription#RunsP50P_{50}P75P_{75}P90P_{90}Max
stepsCumulative daily step count3756.0105.0212.4236
steps_rateInterval-level step rate3853.0101.25209.8236
bodyBatteryGarmin Body Battery score (5-100)8335.098.0207.81484
hrHeart rate (bpm)16225.063.75154.71492
ibiInter-beat interval (ms)21218.539.25120.11491
sleepSleep stage (0-4)10716.039.0185.01333
device_stressGarmin stress score (0-100)11712.05.018.01492
breathsPerMinuteRespiratory rate (breaths/min)53682.03.07.01496
pulseOxPeripheral oxygen saturation (%)129281.01.03.04389

References (21)