arXiv:2610.35132cs.CVOct 2026

Manuscript Offprint

arXiv:2610.35132

Domain-Adapted Latent Diffusion Models for CT-to-PET Image Translation

Yann Bourdé, Lea Bogensperger, Arnela Hadzic, Michael Krauthammer

Yann Bourdé ∗1^{*1}, Lea Bogensperger 1^{1}, Arnela Hadzic 2^{2}, and Michael Krauthammer 1^{1}

*yann.bourde@uzh.ch

1^{1} Department of Quantitative Biomedicine, University of Zurich

2^{2} Institute for Medical Informatics, Statistics and Documentation, Medical University of Graz

Abstract. Positron Emission Tomography (PET) provides important metabolic information for tumor detection and staging but remains significantly less accessible than Computed Tomography (CT) due to its high cost, infrastructure requirements, and reliance on injected radioactive tracers. CT-to-PET image translation using generative models aims to address this disparity, yet state-of-the-art diffusion-based methods are limited by the scarcity of paired training data. To overcome this, we propose a domain-adapted latent diffusion framework that transfers natural-image priors using a relatively small dataset of 21,930 paired CT/PET slices, incorporating a signed power transform to resolve extreme intensity sparsity in PET data. Compared to CPDM, a state-of-the-art baseline for CT-to-PET image translation, our approach yields superior performance in pixel-wise reconstruction and localized tumor fidelity, demonstrating effective transfer of natural-image priors to the medical domain. We further provide a systematic analysis of evaluation metric reliability for sparse PET data, showing that standard full-image metrics can be misleading indicators of translated image quality, and propose background-filtered and mask-restricted metrics as more clinically meaningful alternatives.

Keywords: CT/PET image translation · Latent diffusion models · Medical image synthesis · Evaluation metrics

1 Introduction

Positron Emission Tomography (PET) and Computed Tomography (CT) are complementary medical imaging modalities that capture anatomical and metabolic information, e.g., for tumor detection, staging, and treatment monitoring. Specifically, CT scans provide high-resolution anatomical information through X-ray attenuation, while PET scans reveal metabolic activity via radiotracer distribution, typically 18{}^{18}F-fluorodeoxyglucose (FDG). Used together, they offer a more complete diagnostic picture than either modality alone. However, PET scanners require costly infrastructure and radiotracer production facilities, making PET imaging less accessible than CT, particularly in low-resource healthcare settings.

Y. Bourdé et al.

With the successful introduction and scalability of generative models [4,10,18,11] and their numerous applications to the medical imaging domain [1,3,5], these methods are also being investigated for paired image-to-image translation tasks such as CT-to-PET image translation [14]. Early approaches relied on Generative Adversarial Networks (GANs) [8,22], which suffered from training instability and mode collapse, while modern state-of-the-art (SOTA) approaches rely on diffusion-based models [14,12]. In particular, latent diffusion models (LDMs) [16] offer a compelling option due to the learned latent space that they operate in, which allows generation of high-resolution images at lower computational cost. For CT-to-PET translation specifically, Nguyen et al. [14] recently introduced the CT-to-PET Diffusion Model (CPDM), a conditional diffusion model based on a Brownian Bridge process that defines a stochastic bridge between CT and PET latents rather than corrupting toward pure Gaussian noise, and additionally incorporates domain knowledge through attention and attenuation map modules. Notably, the authors report that LDM priors were inferior to CPDM in their experiments [14]—a finding we revisit in this work.

A common limitation across these approaches is the scale of publicly available paired CT/PET datasets [13]: current SOTA models are trained from scratch on this scarce data [14,12], potentially limiting their performance and ability to generalize beyond the training distribution.

Motivated by this gap, we introduce a domain-adapted latent diffusion framework for CT-to-PET image translation in this work. We demonstrate that transfer learning by finetuning a model pretrained on natural image priors effectively mitigates data scarcity and enhances PET synthesis fidelity. Our contributions are summarized as follows:

– We implement a transfer learning strategy to adapt natural image priors to the PET domain and introduce a signed power transform to reduce the extreme intensity imbalance in PET images.

– We demonstrate that our framework yields superior performance in pixel-level reconstruction and localized tumor fidelity compared to the state-of-the-art diffusion-based CPDM [14], while offering a data-efficient approach for CT-to-PET image translation.

– We analyze the limitations of standard metrics for sparse PET data and propose background-filtered and mask-restricted metrics as more clinically meaningful alternatives.