Model Effect or Label Effect? Refined Annotations and a Human-Referenced Benchmark for Pulmonary Embolism Segmentation

Qihang Sun, Zhongxiao Liu, Bailiang Jian, Shenman Qiu, Jingyuan Wang, Lei Zhang, Lixiang Xie, Jiazhen Pan, Christian Wachinger

Abstract

Purpose: To quantify how evaluation annotations influence measured pulmonary embolism (PE) segmentation performance relative to model training changes, and to establish a human-referenced framework.

Materials and Methods: This retrospective study screened 166 voxel-annotated CT pulmonary angiography cases from CADPE (n = 91), FUMPE (n = 35), and READ (n = 40); 149 were included. A primary rater annotated PE by protocol, and a senior thoracic radiologist reviewed and revised all segmentations. Three additional raters at three centers annotated a 15-case subset. The label effect was measured by evaluating two pretrained nnU-Net models (nnU-Net-A, nnU-Net-B) against original and refined annotations. The model effect was measured by comparing the same architecture trained on different dataset combinations with annotations fixed. The benchmark model (nnPE) was trained with leave-one-dataset-out and pooled five-fold cross-validation. Four metric categories were analyzed with case-paired Wilcoxon signed-rank tests, Benjamini–Hochberg correction, and bootstrap 95% CIs.

Results: Changing only the annotation increased mean DSC by 0.143 (0.122–0.166) for nnU-Net-A and 0.188 (0.163–0.213) for nnU-Net-B (both P<.001P < .001), whereas changing training-dataset composition changed DSC by 0.028. The label effect exceeded the model effect on CADPE and FUMPE and was 0.045 on READ. Within-mask attenuation SD fell in all three datasets after re-annotation (all P<.001P < .001). nnPE reached DSC 0.72±0.220.72 \pm 0.22 on pooled cross-validation but scored below all four annotators across 52 paired comparisons (all corrected P<.05P < .05).

Conclusion: Evaluation annotations affected measured PE segmentation performance at least as much as model training choices. A human-referenced evaluation framework is publicly available for future study.

*Corresponding author: Bailiang Jian, Technical University of Munich, Holbeinstr. 11, 81679 München, Germany. Phone: (089) 4140-2621.

Email address: bailiang.jian@tum.de (Bailiang Jian)

Keywords: Thorax, Pulmonary Arteries, CT Angiography, Embolism, Segmentation, Supervised Learning, Convolutional Neural Network, Application Domain

1. Introduction

Pulmonary embolism (PE) is a common and life-threatening cardiovascular disease. Computed tomography pulmonary angiography (CTPA) is the standard imaging modality for PE diagnosis owing to its high sensitivity and specificity [1]. Thrombus burden quantified on CTPA correlates with right ventricular dysfunction and contributes to risk stratification in acute PE [2, 3], and quantitative imaging features derived from PE lesions can further refine severity classification and early-death risk assessment [4]. Accurate segmentation of pulmonary emboli on CTPA is therefore clinically valuable as a prerequisite for reliable volumetric quantification and downstream risk assessment.

Manual segmentation is time-consuming and observer-dependent, motivating automated approaches based on deep learning. Since the early application of U-Net framework [5], the literature has increasingly focused on algorithmic and architectural comparisons, with research routinely claiming performance breakthroughs. For instance, Amini et al. (2026) found nnU-Net to perform best among 2D and 3D variants, with the 3D configuration exceeding its 2D counterpart by approximately 9 percentage points in Dice Similarity Coefficient (DSC), and Zhang et al. (2026) reached the same conclusion in a broader benchmark covering PE-specific and general-purpose segmentation networks, both on private dataset [6, 7].

Reported benchmark results often differ substantially from those in the original publications for three main reasons. First, evaluation protocols vary; for example, Aydin et al. (2023) computed metrics only on positive slices, which suppresses false positives [8]. Second, data leakage is also common, as these studies split thin-slice CTPA at the slice level, so anatomically adjacent slices from the same patient fall on different sides of the split [9, 10, 11]. Finally, many studies reported only private-dataset results under restrictive case selection: Doğan et al. (2024) kept only the slice containing the largest embolus per case and reported DSC 0.95 on its internal test set [12]; Liu et al. (2022) retained only slices near the main pulmonary trunk and reported 0.97 on internal testing [13]. These design choices reduce the validity or clinical representativeness of the reported estimates. However, they do not address a separate question: whether the annotations used for evaluation are themselves accurate and consistent.

Only three publicly available voxel-level PE segmentation datasets exist: CADPE [14], FUMPE [15] and READ [16], and label errors have been reported in all three, ranging from omitted emboli to labeling of partial-volume artifact in small vessels as distal PE [7, 17, 18]. These reports have been treated as fixed characteristics of individual datasets rather than as a property of the measurements taken against them. Yet every comparison cited above was computed against these labels, so a difference in label fidelity between two evaluations cannot be told apart from a difference in model capability. Separating the two requires quantifying each on the same cases: the label effect, defined as the change in measured performance when identical predictions are scored against different sets of labels, and the model effect, defined as the change when the model or its training data are changed while the labels are held fixed.

The contributions of this work are as follows:

(i) We quantified the label effect and the model effect on the same 149 cases under an identical metric set with case-level pairing.

(ii) We examined the original masks against three criteria independent of the refined reference: within-mask CT attenuation (physical), agreement among four annotation sets produced under the same protocol on a 15-case subset (human), and performance of two externally trained models that had not used either set of public test annotations (model).

(iii) We annotated all three public pixel-level PE datasets (CADPE, FUMPE, READ) under a unified protocol, producing preprocessed CTPA volumes and new PE reference segmentations for 149 studies (FairPE).

(iv) We established a human-referenced evaluation framework comprising annotation protocol, multi-rater uncertainty ranges, a multi-dimensional metric set, and a baseline trained on the refined annotations (nnPE), providing a common reference standard for future studies.

All refined annotations, pre-trained model weights, the evaluation toolkit and reproduction scripts are publicly released at https://github.com/iblueer777/PEbench.