Metric Scale for Insta360 Structure-from-Motion from the Camera's Embedded IMU

Davide Cuttini, Diego Di Tommaso, Alessio Antoniacomi, Luca Simonetti

Abstract

Structure-from-motion (SfM) from the dual-fisheye video of a consumer 360-degree camera recovers geometry only up to a similarity transform; in the pipeline considered here, metric scale is obtained from smartphone ARKit or ARCore poses captured alongside the camera. This paper evaluates a self-contained alternative: the IMU embedded in the Insta360 X5 and X6, recorded at 1 kHz. The sensor is characterised (noise density, camera-IMU synchronisation, accelerometer scale factor, bias stability), the camera-IMU rotation and frame timing are estimated from the data, and the scale is recovered by a linear visual-inertial alignment over the SfM poses of a whole survey. The standard formulation, with gravity and accelerometer bias shared across the survey, overestimates the scale by 3.4% on average; estimating each contiguous segment independently and averaging removes the bias. On nine surveys with a co-mounted LiDAR scanner the inertial scale deviates from the LiDAR by 0.81% in mean absolute error, against 1.94% for the smartphone scale; on printed fiducial markers both agree within the 1% uncertainty of the target. On the reference trajectories of thirty sequences of a public benchmark, brought to scales of 1/40, 1 and 40, the estimator recovers the metric scale with a mean error of -0.07% and a standard deviation of 1.28%. On fifty production surveys where the smartphone is the only reference, the two scales agree to a standard deviation of 2.3%, the inertial scale being 0.3% lower on average; the difference is uncorrelated with run length, grows with the extent of the smartphone anchor, and cannot be attributed to either reference. An ablation over window construction and a comparison with monocular metric-depth networks complete the study.

1 Introduction

Structure-from-motion without a baseline of known length recovers scene structure and camera trajectory up to a similarity transform: shape and trajectory are determined, absolute size is not. For a mapping pipeline that reconstructs scenes from the native dual-fisheye video of an Insta360 camera, the missing scale must be supplied by an external measurement. The current solution uses a smartphone carried by the operator. During the survey the operator captures a burst of photographs whose poses are metric, from ARKit on iOS or ARCore on Android; the photographs are registered jointly with the fisheye frames, and a robust alignment transfers the smartphone scale to the model.

This arrangement has three costs. It requires a second device and a second capture procedure. It makes the metric reference heterogeneous, since the two smartphone platforms and their versions behave differently. And it extrapolates from a small spatial baseline: the burst is taken within about 15 s over a few metres, so the metric scale of a survey of several hundred metres rests on a short segment of it, and any error in the smartphone poses over that segment propagates to the whole model. Section 5.2 quantifies the consequence: across nine surveys with a co-mounted LiDAR scanner, the smartphone-anchored models deviate from the LiDAR by 1.9% in mean absolute error, with individual surveys reaching 4.4%. The smartphone remains a serviceable reference, and this figure is its measured accuracy rather than a failure; the question addressed here is whether a sensor already inside the camera can take its place.

Preprint

The Insta360 X5 and X6 contain a gyroscope and an accelerometer sampled at 1000 Hz and written into the recording. The accelerometer measures specific force in metres per second squared. For a trajectory expressed in the arbitrary units of an SfM model there is exactly one scale factor for which its second derivative agrees with the measured accelerations once gravity is accounted for. Recovering that factor is the visual-inertial initialisation problem, which is well studied in the context of real-time SLAM [16, 17, 21]. The setting here differs in three respects: the poses are the output of an offline SfM pipeline rather than a tracker, the alignment is performed in batch over surveys lasting minutes rather than over the first seconds of motion, and the frames used by the reconstruction are sparse in time, several per second at most, while the IMU is continuous.

The contributions of this paper are the following.

  1. A characterisation of the embedded IMU of the Insta360 X5 and X6 as recorded in the .insv container: noise density, camera-IMU time offset and axis mapping, accelerometer scale factor and bias stability.

  2. A data-driven estimation of the camera-IMU rotation and of the affine frame-timing model, together with a diagnostic that detects a wrong timing model without ground truth.

  3. Evidence that the joint linear alignment over a whole survey, with shared gravity and accelerometer bias, is biased high by 3.4% on the surveys with external reference, and that a segment-wise estimate followed by averaging removes the bias. An ablation over window construction shows that the improvement is due to not sharing the nuisance parameters and is insensitive to how the survey is divided.

  4. An evaluation against four independent references: nine surveys with a co-mounted LiDAR scanner, one survey with printed fiducial markers of known geometry, 62 production surveys with smartphone poses, and the reference trajectories of thirty sequences of a public benchmark. On the LiDAR surveys the inertial scale is 2.4 times more accurate than the smartphone reference.

  5. A comparison with monocular metric-depth networks as an alternative scale source, showing that their scene-dependent bias makes them unsuitable as a reference at the accuracy level considered.

The paper is organised as follows. Section 2 reviews related work. Section 3 describes the method. Section 4 describes the data and the reference measurements. Section 5 reports the sensor characterisation and the experimental results. Section 6 discusses the two main findings and the limitations of the study, and Section 7 concludes.