Synthetic Deformable Tubular Benchmark: A mechanically annotated dataset for evaluating deformable 3D reconstruction

Íñigo Cirauqui-Viloria

Abstract

Evaluating deformable 3D reconstruction in tubular environments requires ground truth that distinguishes camera motion, surface deformation, material correspondence and image appearance. Existing endoscopic datasets provide complementary annotations; controlled evaluation additionally benefits from explicit links between observations, material identities and mechanical states. We introduce the Synthetic Deformable Tubular Benchmark, generated with LumenMorph, an open-source toolkit for creating, annotating and evaluating deformable tubular scenes. The release contains 5,580 RGB images. The baseline crosses three surface-motion conditions with moving and stationary cameras in six families; matched appearance variants cover only moving-camera finite-element actions in four families. Known camera poses, surface geometry, depth, deformation fields, persistent material correspondences and discrete finite-element records are accessible through documented public and evaluation interfaces. Separately implemented geometric and mechanical checks assess annotation consistency with the generating models. Structure-from-motion, optical-flow and supplied-geometry displacement-interpolation studies demonstrate the resource's utility. They distinguish registration coverage from geometric accuracy, expose camera- and surface-motion effects, and test mechanical priors. Persistent triangle identities and material weights let users follow the same surface location across frames, query its three-dimensional trajectory and evaluate predictions against known motion. Public readers, explicit evaluation contracts and the configurable generator support reuse and extension beyond the released acquisitions. Mechanical interpolation illustrates both benefits and mismatch of a prior, rather than a general ranking of estimators. The fixed benchmark provides a reusable reference under explicit synthetic assumptions. Data integrity, fixed-environment repeatability and retained-prediction score replay have distinct verification scopes; anatomical and clinical realism are not claimed.

Keywords: Deformable 3D reconstruction; Synthetic dataset; Ground truth; Finite element method; Endoscopic imaging

1 Introduction

Deformable reconstruction in colonoscopy must distinguish camera motion from surface motion under limited visibility. A rigid reconstruction accumulated over time can absorb deformation into biased camera poses or geometry. Surface similarity alone may also conceal correspondence errors: a nearby surface point need not be the same material point—a fixed location on the wall followed as it moves. Evaluation therefore requires linked observations, material identities, geometry and visibility, together with explicit assumptions about the motion-generating model. Known camera poses alone do not resolve the inverse deformation problem.

We present the Synthetic Deformable Tubular Benchmark, a controlled synthetic resource (Cirauqui-Viloria, 2026c). It was generated with LumenMorph, an openly available generator and evaluation toolkit (Cirauqui-Viloria, 2026a). Figure 1 introduces the six scene families: one straight and five bent tubes, each observed under paired motion and camera conditions. A matched appearance extension changes lighting, reflectance and exposure on four of these same families. The resource links material trajectories, discrete finite-element (FE) records, image annotations and estimated reconstructions. This connection allows a user to ask not only whether a surface looks correct, but whether the same material points move correctly and whether missing surface support explains an apparently low error. Data, code and reproduction resources are identified in Sections 7–8.

Rest geometry · common scale

f01

Straight

Moderate motion

f02

Right bend, 30∘30^{\circ}

Moderate motion

f03

Upward bend, 35∘35^{\circ}

Strong motion

f04

Left + down bends

Moderate motion

f05

Right bend, 38∘38^{\circ}

Moderate motion

f06

Up + left bends

Strong motion

Figure

Reference RGB

Figure

Figure 1. Six controlled scene families: one straight tube (f01), single bends to the right or upward (f02, f03, f05), and two successive bends (f04, f06). Geometry views share a common scale; the right column shows each family's reference image with its seeded wall texture. f03 and f06 use twice the displacement-basis amplitudes of the other families. Table 2 specifies bend angles and paired acquisitions.

The methodological contribution is a benchmark with an explicit, accessible and checked connection between image observations, camera states, persistent material identities, deformed geometry and discrete mechanical records. This integration lets researchers evaluate reconstruction accuracy, material-motion consistency and surface support under paired acquisition conditions, without introducing a new reconstruction algorithm. The novelty is the queryable connection, rather than any one annotation or the use of simulation alone. The reusable contribution has two parts: the fixed, versioned benchmark, with linked annotations and separately implemented consistency checks; and LumenMorph, the open-source generator and reader/evaluation toolkit for creating and studying additional tubular configurations. Reconstruction, optical-flow and supplied-geometry mechanical studies illustrate uses of these resources. They distinguish camera accuracy, sparse geometry, surface support and registration coverage, while a static phantom control examines performance on physical imagery under its declared acquisition contract. The engineered scene families provide controlled reconstruction diagnosis, not a sampled clinical population.