arXiv:2608.24555cs.HCAug 2026

Manuscript Offprint

arXiv:2608.24555

StrokeGuard: A Multi-Agent Guided System for Prehospital Stroke Assessment

Wentao Yang, Zhenye Xu, Ruoyi Li, Musen Zhang, Yao Guo

Wentao Yang

Institute of Medical Robotics

School of Biomedical Engineering

Shanghai Jiao Tong University

Shanghai, China

tao615@sjtu.edu.cn

Zhenye Xu

Institute of Medical Robotics

School of Biomedical Engineering

Shanghai Jiao Tong University

Shanghai, China

lingyy1109@gmail.com

Ruoyi Li

Institute of Medical Robotics

School of Biomedical Engineering

Shanghai Jiao Tong University

Shanghai, China

rowenalee@sjtu.edu.cn

Musen Zhang

Institute of Medical Robotics

School of Biomedical Engineering

Shanghai Jiao Tong University

Shanghai, China

musen_zhang@sjtu.edu.cn

Yao Guo

Institute of Medical Robotics

School of Biomedical Engineering

Shanghai Jiao Tong University

Shanghai, China

yao.guo@sjtu.edu.cn

Abstract—Prehospital stroke assessment aims to accurately identify stroke symptoms and make rapid decisions through standardized procedures within an extremely narrow time window, thereby saving valuable time for subsequent treatment. In clinical practice, FAST-based scales are widely used for prehospital stroke assessment by issuing instructions that guide subjects to perform specific actions to screen facial, arm, and speech functions. However, in home and community settings, non-clinical users often encounter challenges such as inaccurate descriptions, incomplete symptom observation, and difficult operational procedures, which may lead to inaccurate or biased assessment results. To address these challenges, this paper presents StrokeGuard—a multi-agent guided system designed for prehospital stroke assessment that makes mobile FAST screening more standardized and executable. Specifically, to overcome the limitations of traditional single-agent systems in terms of procedural fault tolerance and user guidance capability, StrokeGuard adopts a dual-channel agent mechanism that separates formal assessment (i.e., facial palsy, arm weakness, speech impairment) from procedural support (e.g., step prompts, error correction, and real-time feedback). It guides the assessment process through multi-agent collaboration, dual-channel interaction, state-machine control, and stage-local fallback recovery mechanisms. Stage-specific scoring is delegated to constrained pretrained video assessment modules, while evidence source records are integrated with structured report generation. The user evaluation uses MATES-9, an exploratory scale for measuring user experience in multistep AI-guided tasks. In a simulated prehospital scenario, StrokeGuard improves the MATES-9 total score over a paper FAST-style form by 10.83 points, corresponding to a 23.8% relative increase.

Index Terms—Prehospital stroke assessment, multi-agent systems, Face Arm Speech Test, human-computer interaction

I. INTRODUCTION

Stroke is an acute neurological event caused by a sudden interruption of cerebral blood flow or rupture of a cerebral vessel. Because brain injury progresses rapidly, prehospital stroke assessment must identify symptoms accurately and support rapid decisions through standardized procedures within an extremely narrow time window. Prehospital screening tools such as the Cincinnati Prehospital Stroke Scale (CPSS) and the Face Arm Speech Test (FAST) reduce stroke recognition to observable facial, arm, and speech signs [1]–[3]. In clinical practice, FAST-based scales guide subjects to perform specific actions so that facial, arm, and speech functions can be screened in a structured manner.

The apparent simplicity of these tools does not directly translate into reliable execution by low-expertise users. In home and community settings, non-clinical users often face inaccurate descriptions, incomplete symptom observation, and difficult operational procedures. Prehospital studies report clear limits in stroke recognition accuracy even when dispatchers and emergency medical personnel participate [9], [10]. Barriers to timely activation of emergency medical services also include difficulty interpreting symptoms, insufficient judgment of severity, and uncertainty about appropriate actions [11]. When FAST-style screening moves from trained personnel to ordinary caregivers, a system must support more than recognition of the three FAST categories. It must also provide procedural guidance, support multimodal evidence collection under time pressure, and preserve the current assessment step after capture failure or workflow interruption.

Recent multimodal stroke systems have advanced perception and classification. DeepStroke uses multimodal adversarial learning to support emergency-room stroke screening [4]. M3 Stroke studies mobile multimodal AI for mild-to-moderate acute stroke triage [5]. Digital FAST explores a multimodal framework aligned with the FAST paradigm [6]. VOICE demonstrates the feasibility of a voice AI agent for simulated prehospital stroke assessment [8]. These studies show that AI

Figure

Fig. 1. High-level overview of StrokeGuard in a simulated prehospital assessment workflow.

can support early triage, but they do not fully address the interaction and handoff problems that arise before a model receives usable input. An assessment model alone cannot guide users through recording failures or preserve workflow order. A general conversational agent can provide flexible dialogue, but it does not by itself guarantee controlled scoring, adequate multimodal input quality, or an auditable handoff for clinicians.

This execution gap is also distinct from the problems addressed by specialized prehospital solutions. Mobile stroke units show that richer prehospital data collection can improve triage and reduce door-to-needle time, but these systems rely on trained onboard personnel rather than ordinary caregivers at the scene [12]. Dispatcher recognition algorithms and structured call-taking protocols have been used to improve telephone-based stroke screening, but they target trained dispatchers rather than direct interactive guidance for untrained on-site users [13].

To address these challenges, this paper presents StrokeGuard, a multi-agent guided system designed for prehospital stroke assessment that makes mobile FAST screening more standardized and executable. To overcome the limitations of traditional single-agent systems in procedural fault tolerance and user guidance capability, StrokeGuard adopts a dual-channel agent mechanism that separates formal assessment of facial palsy, arm weakness, and speech impairment from procedural support, including step prompts, error correction, and real-time feedback. It guides the assessment process through multi-agent collaboration, dual-channel interaction, state-machine control, and stage-local fallback recovery. Stage-specific scoring is delegated to constrained pretrained video assessment modules, while evidence-source records are integrated with structured report generation.

This paper makes three contributions:

• A prehospital stroke assessment agent system. StrokeGuard reframes FAST-style screening for low-expertise users as a multi-agent assessment execution problem and places formal assessment, procedural support, stage progression, local fallback, and source-preserving handoff within explicit responsibility boundaries.

• A controlled execution architecture for assessment agents. The architecture separates agent interaction, deterministic orchestration, and dedicated scoring modules, allowing stage-specific modules to be replaced by different stroke recognition algorithms and supporting transfer to other clinical screening tasks with fixed procedures or multiple assessment items.

• An evaluation design for controlled assessment agents. The paper uses mechanism-ablation case studies to examine the roles of dual-channel constraints, evidence-aware orchestration, and stage-local recovery, and proposes MATES-9 as an exploratory tool for evaluating the experience of multistep AI-guided tasks.

References (27)