arXiv:2610.32067cs.LGOct 2026

Manuscript Offprint

arXiv:2610.32067

Controlled Evaluation of EEG Foundation Models: Random Initialisation, Band-Power and Validation-Selected Probes

Mingyu Jeon, Suwan Cho, Jae Young Suh

Abstract

EEG foundation models report downstream gains, yet their protocols seldom include three controls. These are the same encoder untrained, spectral features fitted on the same data, and a layer picked without looking at test scores. We therefore evaluate five publicly released EEG foundation models and an in-house JEPA-style model under one protocol with all three controls and several seeds, on five benchmarks and four added task families. The controls change the reading in three ways. First, picking the probed layer by its test score raises the layer-wise peak by an average of +0.034 and reverses the peak-versus-output gap in 9 of 36 cells. Second, with the layer picked on validation, random initialisation matches or beats pretraining for half of the models on sleep and emotion, and no model beats a five-band log-power baseline on emotion or motor imagery. Third, after full fine-tuning only 5 of 30 pairs gain beyond twice their seed spread, and the one clear loss of -0.290 AUROC persists under matched learning rates. From these results we draw four reporting practices, and we release every cell for re-analysis.

1 Introduction

Recent EEG foundation models such as LaBraM (Jiang et al., 2024), EEGPT (Wang et al., 2024), CBraMod (Wang et al., 2025), LUNA (Döner et al., 2025) and LuMamba (Broustail et al., 2026) each report downstream gains under their own protocol, with its own splits, heads, schedules and hyperparameters. These protocols differ, so the published numbers cannot be compared across papers, and none of the papers evaluates the other models under its own protocol (Jiang et al., 2024; Wang et al., 2025; Döner et al., 2025). Three controls are missing from most of these reports. The three are a matched encoder of the same architecture at random initialisation, a band-power baseline on the same split, and a probed layer chosen on validation instead of on test (Section 3.4). Each is standard in representation-learning evaluation (Alain & Bengio, 2017; Musgrave et al., 2020; Pineau et al., 2018).

Such controls have changed conclusions before. In other fields they shrank the reported gains, as metric-learning improvements nearly vanished under one fixed protocol (Musgrave et al., 2020) and better ImageNet models did not always transfer better (Kornblith et al., 2019). The same happened in time-series forecasting, where linear models rivalled transformer forecasters (Zeng et al., 2023) and the pretrained language model could be removed from language-model forecasters without loss (Tan et al., 2024). Whether EEG foundation models keep their gains once all three controls are in place is the question this paper measures.

We came to this question from the model side, after building an in-house JEPA-style model for arbitrary montages (Assran et al., 2023; Balestriero & LeCun, 2025; Maes et al., 2026) and pretraining it on the REVE corpus (El Ouahidi et al., 2025) (Figure 1). Its frozen output-layer probe on Lee2019 motor imagery (MI) scored 0.507 AUROC, below the 0.741 of a five-band log-power baseline, band power, computed on the same split (Lee et al., 2019). Probing every internal stage then located the loss, because an early front-end stage reached 0.708 and the later stages lost that signal again (Figure 3, left). That observation turned the project into a controlled evaluation of five public EEG foundation models. The in-house model stays in the panel as one row, under the same adapter interface, splits, probe and hyperparameters as the others.

The paper makes three contributions. First, it evaluates six models under all three controls, covering 30 model-dataset pairs under frozen probing and full fine-tuning at 5 seeds (Section 3.3). It extends them with four task families (event-related potential (ERP), sleep, emotion and within-subject MI) at 3 seeds wherever the seed changes the result, with LuMamba absent from within-subject MI. Second, it reports what survives the controls: test selection inflates layer-wise peaks and the band-power baseline is rarely beaten (Section 4). It also finds that random initialisation often matches pretraining under a frozen probe and that most fine-tuning gains sit within seed noise (Sections 4.5 and 4.6). Third, it describes the diagnostic protocol that exposed the in-house failure and turns it into reporting practices for evaluating EEG foundation models (Sections 3.5 and 5). One distinction runs through all three. Representation quality, read by a frozen probe, is kept apart from trainability, the fine-tuning gain over random initialisation (Section 3.4). Performance after per-model tuning is a third notion, which a shared protocol bounds from below and does not measure (Section 4.6).

References (47)