arXiv:2608.24597cs.LGAug 2026

Manuscript Offprint

arXiv:2608.24597

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui, Dinggang Shen

Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

Keywords: Electroencephalography, EEG foundation model, Transferable neural representation, Self-supervised learning

1 Introduction

Electroencephalography (EEG) is a central tool for studying human brain activity in neuroscience, clinical neurophysiology and brain-computer interfaces [1]. After acquisition, EEG supports a broad spectrum of analysis tasks that can be viewed at three progressively higher levels: signal-level assessment, brain-state decoding, and brain-health evaluation. Signal-level assessment focuses on the quality, abnormality and reliability of the recording itself. Brain-state decoding aims to infer transient physiological or behavioural states from ongoing neural activity. Brain-health evaluation further asks whether EEG contains clinically relevant variation associated with psychiatric, cognitive or neurological conditions. These tasks differ in temporal scale, label granularity, electrode configuration, cohort composition and clinical or behavioural context, yet they all require models to extract meaningful neural information from noisy scalp recordings. An ideal EEG representation model should therefore support not only one benchmark or one label space, but broad-spectrum EEG analysis.

This broad-spectrum setting makes reusable EEG modelling both important and difficult. Although EEG is non-invasive, inexpensive, portable and temporally precise, scalp measurements have a low signal-to-noise ratio and reflect the interaction of neural activity, volume conduction, scalp anatomy, electrode placement, referencing, behavioural state and environmental artifacts [2, 3]. Consequently, signals recorded from different subjects, devices, montages or task contexts can vary substantially even when they contain related neural information. A model intended for broad-spectrum EEG analysis must therefore learn representations that remain useful across signal-level assessment, brain-state decoding and brain-health evaluation, rather than representations that are only optimized for one dataset or one application level.

However, most deep learning approaches for EEG decoding still follow a task-specific supervised paradigm, as exemplified by EEGNet [4], ST-Transformer [5], EEGConformer [6] and SPaRCNet [7]. In this setting, a model is trained from scratch on a single dataset with one acquisition protocol and one label space. Such models can perform well when training and test conditions are tightly matched, but they often learn features entangled with subject cohort, montage design, preprocessing choices, annotation protocol and device characteristics. This one-dataset-one-model paradigm fragments EEG analysis and limits the reuse of neural representations across tasks, subjects and acquisition configurations, thereby constraining broad-spectrum EEG applications.

Self-supervised foundation pre-training offers a route toward reusable EEG representations. Large clinical and experimental EEG archives contain thousands of hours of unlabelled recordings that capture rich variation in neural dynamics and physiological state. An EEG foundation model should convert such data into a transferable starting point for broad-spectrum downstream analysis [8, 9]. However, the pre-training objective is critical. Unlike text or natural images [10–13], EEG is neither symbolic nor spatially stable. It is also strongly subject-sensitive: short scalp recordings can contain stable individual physiological signatures, and state- or condition-related effects are often expressed as deviations from a subject-specific baseline rather than as absolute waveform patterns. A transferable EEG encoder should therefore preserve subject-stable physiological structure while keeping state-, disease- and artifact-related variations accessible for downstream discrimination. Yet, pure reconstruction-based objectives, as commonly adopted by recent EEG foundation models such as CBraMod [14], CSBrain [15] and CodeBrain [16], do not explicitly enforce this form of discrimination and can therefore learn the signal details that are useful for reconstruction but not necessarily transferable.

We introduce INCEPT, short for INvariance-oriented Contextual EEG Pre-Training, an invariance-oriented EEG foundation model designed to learn transferable whole-brain representations from unlabelled EEG. INCEPT combines masked contextual learning with invariance-oriented pre-training: contextual learning captures local temporal, spectral and cross-channel dependencies, whereas invariance learning asks which essential subject-sensitive information remains stable across different observations of the same subject and recording context. To reduce dependence on fixed channel identities or channel order, INCEPT further encodes continuous scalp positions using spherical-harmonics-based electrode embeddings [17]. The resulting compact global representation is designed to be readable by a lightweight supervised head when the backbone is frozen, and to be reshaped by downstream labels when the backbone is fully fine-tuned. Together, these design choices define the invariance-oriented modelling paradigm summarized in Fig. 1, which contrasts task-specific supervised encoders trained separately for each dataset, reconstruction-centered EEG foundation models that emphasize local signal recovery, and INCEPT as a compact whole-brain representation learner combining contextual modelling with cross-view invariance learning.

Figure

Fig. 1: Comparison of EEG modelling paradigms. Schematic comparison of task-specific supervised EEG encoders, reconstruction-centered EEG foundation models and the proposed invariance-oriented INCEPT framework. INCEPT learns compact global EEG representations through invariance-oriented contextual pre-training while retaining patch-level features as optional outputs.

We evaluate INCEPT across ten downstream datasets organized into three domains of post-acquisition EEG analysis: signal-level EEG assessment, brain-state decoding, and brain-health evaluation. These datasets cover abnormal EEG detection, artifact-type recognition, emotion recognition, motor imagery, sleep staging, mental-stress recognition, depression-related assessment, neurodegenerative disease evaluation and seizure detection [18–30]. We test each foundation model under linear probing, which measures the readability of frozen representations, and full fine-tuning, which measures supervised adaptability. Across this heterogeneous benchmark, INCEPT achieves the most consistent performance among recent EEG foundation models, while controlled ablations show that invariance-oriented pre-training improves transfer beyond reconstruction alone. Together, these results support INCEPT as a transferable backbone for broad-spectrum EEG analysis.

References (50)