Manuscript Offprint
arXiv:2610.32361FOCUS: A Lightweight Mamba-2 Model for EEG-Based Cognitive Workload Classification
Ioannis Kyprakis
Hellenic Mediterranean University
Heraklion, Greece
Stefanos Gkikas
Honda Research Institute Japan
Wako City, Japan
stefanos.gkikas@jp.honda-ri.com
Zongyi Jiang
University of Canberra
Canberra, Australia
Chariklia Chatzaki
Hellenic Mediterranean University
Heraklion, Greece
Randy Gomez
Honda Research Institute Japan
Wako City, Japan
Raul Fernandez Rojas
BioSIS (Biosensing & Intelligent Systems) Lab
Centre for Intelligent Computing and Systems
University of Canberra
Canberra, Australia
raul.fernandezrojas@canberra.edu.au
Manolis Tsiknakis
Hellenic Mediterranean University
Heraklion, Greece
Abstract—Cognitive workload estimation from physiological signals is increasingly relevant in high-risk environments, where continuous and unobtrusive monitoring can inform adaptive systems and safety interventions. This paper presents FOCUS (Frequency-band Optimized Cognitive-load Ultralight SSM), a compact Mamba-2-based model for EEG-based binary workload classification under constrained data conditions. Rather than learning frequency sensitivity from data, FOCUS encodes preprocessed multi-channel EEG using a fixed FFT decomposition that covers the five canonical EEG bands. The proposed model combines depthwise-separable convolution and a weight-shared encoder-bottleneck Mamba-2 pair, with 0.04 M parameters and 0.11 GFLOPs. Evaluated in a pilot study with 11 participants under leave-one-subject-out cross-validation across three cognitively distinct tasks, FOCUS achieves 74.75% accuracy on the full dataset at 0.08 ms GPU model-forward latency. In the weight-sharing ablation, the shared configuration achieves 4.55 percentage points higher accuracy on the full dataset than the non-shared variant while reducing the SSM parameter budget; however, this difference does not reach statistical significance under a two-sided Wilcoxon signed-rank test (p = 0.083). Overall, the selected FOCUS configuration provides a favorable trade-off between classification performance and computational cost within this controlled pilot setting.
Index Terms—cognitive fatigue, mental workload, physiological signals, brain activity, electroencephalogram
I. INTRODUCTION
Cognitive workload refers to the mental effort working memory requires to perform a task. In high-risk domains such as aviation, automotive systems, robotics, and automated industries, real-time cognitive workload estimation has important implications for safety and performance. Detecting when a person may need support due to increased cognitive workload is also relevant beyond professional environments, such as health care and education. For instance, early identification of elevated cognitive workload may enable timely assistance [1] [2]. Workload assessment methods are generally divided into subjective and objective approaches [3]. Subjective tools, such as the NASA Task Load Index (NASA-TLX), are well validated but can only be applied after task completion, preventing real-time monitoring [4]. Objective approaches leverage the relationship between mental effort and autonomic or cortical nervous system activity, allowing continuous estimation through physiological sensors [5]. Common physiological modalities for cognitive workload estimation include electroencephalography (EEG), electrocardiography (ECG), electrodermal activity (EDA), and respiratory signals. Different physiological and neuroimaging signals capture distinct aspects of cognitive demand, reflecting its multidimensional nature [6]. The cognitive workload literature has explored a broad range of modality configurations, from focused single-signal approaches to predefined multimodal combinations, each demonstrating value across different tasks and deployment contexts [5], [7]–[9]. A significant portion of multimodal architectures in this space employs modality-specific feature extraction and explicit fusion mechanisms, such as intra-modality encoders, dual-branch networks, or decision-level modules, which are typically designed around a fixed sensor configuration and optimized for specific input settings [10]–[12].
Among these physiological modalities, EEG has received particular attention because it directly measures cortical activity and captures rapid changes associated with cognitive engagement [13]. EEG-based workload studies often examine oscillatory activity because alpha and theta rhythms have been associated with cognitive and memory processes [14]. These characteristics make EEG relevant for monitoring workload in applied domains where excessive cognitive demand may affect safety and performance, including aviation, driving, and human-machine interaction [15]. However, EEG-based workload assessment remains challenging because workload-related neural patterns can vary across individuals, tasks, and experimental contexts, making generalization across task conditions an important issue [16].
This pilot study followed a controlled experimental protocol involving 11 participants who completed three cognitive tasks: a fluid intelligence reasoning task, a numerical processing task, and an interactive video game. Each task was administered at two difficulty levels, easy and hard, in order to induce different levels of cognitive workload. Continuous EEG recordings were acquired during task performance to capture workload-related neural activity across both conditions. In addition, this study proposes Frequency-band Optimized Cognitive-load Ultralight SSM (FOCUS), a compact Mamba-2-based sequence model designed for high efficiency and low model-side computational cost in adaptive systems and user-support applications.
Beyond general engineering and human–machine interaction contexts, EEG-based cognitive workload monitoring has gained particular relevance in health-related settings, where cognitive overload and fatigue may affect clinical performance and patient safety. In the surgical domain, prefrontal EEG beta activity has been shown to differentiate workload levels imposed by surgical procedures of varying complexity, suggesting that EEG-based indices can provide objective, nonintrusive measures of mental overload in surgeons and may support monitoring of surgeons and residents during training [22]. More recent work has extended this line of research to robot-assisted surgery, proposing machine learning frameworks that estimate cognitive workload from EEG epochs recorded across multiple cortical regions, including the frontal, temporal, parietal, and occipital areas [23]. The relationship between cognitive fatigue and medical error has also been examined in simulation-based medical education, where mobile EEG has been proposed as an objective tool for assessing cognitive fatigue in medical trainees during simulated clinical work [24]. Outside the surgical context, EEG-based passive brain–computer interfaces have been explored for adaptive learning systems, where real-time cognitive load estimation can dynamically adjust the pace of information presentation [25]. In cognitive training contexts, wearable EEG setups have demonstrated feasibility for tracking workload during N-back tasks, suggesting potential relevance for evaluating cognitive training approaches, including future clinical or rehabilitation-oriented applications [26]. Collectively, these studies indicate that EEG-based workload estimation is not merely a performance optimization tool but a potentially useful measurement modality for adaptive health informatics, medical training, and cognitive monitoring systems.
III. METHODOLOGY
This section describes the data acquisition and pre-processing pipeline as well as the proposed FOCUS architecture for EEG-based cognitive workload classification.
A. Data Collection
This study uses the EEG dataset described in the study [21]. The dataset comprises eleven participants (6 male and 5 female; ages 20–40 years; mean age ). None reported neurological disorders or use of substances affecting the nervous system on the day of the experiment. All participants provided written informed consent, and the Institutional Review Board approved the study protocol. Participants performed three cognitively diverse tasks: an abstract reasoning task (IQ, Raven's Progressive Matrices), a numerical problem-solving task (MATH), and an interactive video game task (GAME, Flappy Bird). Each task was presented at two predefined difficulty levels (Easy and Hard), providing controlled experimental conditions designed to induce differences in cognitive demand. The validity of these conditions has been previously examined using the same task protocol. Analysis of NASA-TLX responses showed significant differences between the Easy and Hard conditions for the Raven and Numerical tasks [6], while an EEG-based mixed-model ANOVA showed significant differences between the Easy and Hard conditions for the Numerical and Game tasks [27]. These complementary subjective and EEG-based analyses provide prior evidence supporting the experimental difficulty manipulation. Continuous EEG was recorded using the EMOTIV EPOC wireless headset with measurement channels (AF3, F7, F3, FC5, T7, P7, O1, O2, P8, T8, FC6, F4, F8, AF4) at a sampling frequency of Hz following the international 10–20 system. Each participant contributed 12 samples per difficulty level per task, yielding samples per task (EASY = 132, HARD = 132). Consequently, each held-out LOSO fold is balanced between the EASY and HARD classes, containing 12 samples per class for each individual task and 36 samples per class in the pooled ALL setting. Each task-difficulty condition lasted 2 min and was divided into twelve non-overlapping 10 s samples; thus, one sample corresponds to a complete 10 s, 14-channel EEG input with time points.
B. Pre-processing
EEG signals were pre-processed offline using EEGLAB in MATLAB. Independent Component Analysis (ICA) was applied to remove eye-blink and muscular artifacts. Components

Fig. 1: Overview of the proposed pipeline.
associated with non-neural activity were visually inspected and excluded, producing clean 10 s samples with T = 1280 time points. The offline ICA artifact-removal stage is not included in the reported model-forward latency.
C. Proposed Architecture: FOCUS
We propose FOCUS, a compact Mamba-2-based sequence model that processes preprocessed multi-channel EEG samples under four explicit design decisions aimed at minimizing the number of parameters while preserving discriminative capacity:
D1: Fixed FFT band decomposition (zero learnable parameters in the filter stage).
D2: Depthwise-separable temporal convolution (substantially fewer parameters than a standard convolution).
D3: Weight sharing between the encoder and bottleneck Mamba-2 blocks (halves SSM parameters).
D4: Minimal model dimensionality .
The model receives a preprocessed multi-channel EEG sample and outputs a binary workload label. Fig. 1 illustrates the full pipeline.
- Input Normalisation: Each channel is independently normalized via Layer Normalization applied over the temporal axis:
stabilizing the amplitude distribution of the data points before any spectral decomposition.
- D1 — FFT Band Embedding: Rather than learning filter banks from data, the model decomposes each channel into five physiologically motivated frequency bands using the discrete Fourier transform. Each channel signal is first multiplied by a Hann window to suppress spectral leakage:
and transformed via the real-valued FFT:
Five band-pass masks are pre-computed with flat unit passbands and two-bin Hann-windowed roll-off transitions at each edge, covering the canonical EEG bands (0.5–4 Hz), (4–8 Hz), (8–13 Hz), (13–30 Hz), and (30–43 Hz). The band-filtered time-domain signal is recovered by the inverse FFT:
The five-band signals across all channels are stacked and reshaped into a sequence (obtained by permuting the tensor to and flattening the last two axes). A single learned linear projection maps this to the model dimension :
where is the only learnable component in the entire embedding stage. The band masks has zero trainable parameters. The inverse FFT in (4) recovers each band signal at the full temporal resolution time points; the decomposition uses fixed frequency-domain bandpass masks rather than a short-time Fourier transform. Consequently, the sequence fed to the encoder has length , not a coarser time-frequency grid. At each time point , the token is a learned projection of the band-filtered time-domain values . The Mamba-2 encoder therefore processes a sequence of 1280 multi-band time-domain representations, learning how the band-wise activity of the full electrode array evolves over the 10 seconds. The complete model totals 0.04 M parameters and consumes 0.11 GFLOPs per forward pass. The measured model-forward latency is 0.08 ms per sample on an NVIDIA GeForce RTX 3090 GPU, where one sample corresponds to a complete 10 s, 14-channel EEG input ( time points). This value excludes the 10 s signal-acquisition period and the offline ICA artifact-removal stage and therefore represents model computation rather than end-to-end decision latency.
- Mamba-2 Encoder Block (D4): The embedded sequence is processed by a Mamba-2 structured state-space model [28]. At each time step , the model maintains a latent state evolving according to the discretized linear recurrence:
where and are input-dependent, discretized matrices derived from learned step-size gate and selective context matrices , . The state dimension is and the internal expansion factor is expand = 2, giving inner channels. A pre-norm residual connection wraps the SSM:
- D2 — Depthwise-Separable Temporal Convolution: After the encoder, the sequence is convolved along the time axis using a depthwise-separable convolution [29] to capture local temporal patterns efficiently. Writing in channels-first layout, the depthwise step applies one independent kernel per feature channel (kernel size ):
followed by Batch Normalization. The pointwise step recombines across channels via a convolution and activates:
A standard convolution requires parameters; the depthwise-separable factorisation uses (depthwise) plus (pointwise) = parameters, a reduction. For , this yields 12,288 versus 4,288 parameters, a saving. Temporal resolution is then reduced by a factor of four via max-pooling:
- D3 — Bottleneck Block with Weight Sharing: The downsampled sequence is further refined by a bottleneck Mamba-2 pass. Under the weight-sharing decision (D3), the same parameter set as the encoder SSM is reused:
where is the identical module from (8). Weight sharing halves the SSM parameter budget: with , sharing saves parameters.
- Classification Head: A global temporal average pools the bottleneck output to a single descriptor, which is regularised via dropout (p = 0.3) and mapped to class logits by a linear layer:
D. Training Configuration
All models are optimized with AdamW ( , weight decay ) under a cosine annealing learning-rate schedule with 20 warm-up and 10 cool-down epochs over 190 total training epochs. A batch size of 32 and label smoothing of 0.10 were utilized during training. Data augmentation is applied per channel during training: polarity inversion, additive Gaussian noise, and temporal masking (window size 15 – 30% of the sequence) are each applied with probability drawn uniformly from [0.01, 0.10]. For each LOSO fold, the model is initialized and trained from scratch on 10 participants, while the remaining participant is held out for evaluation. The reported result for each fold corresponds to the maximum accuracy achieved on the held-out participant over the fixed 190-epoch training horizon, and final performance is computed as the mean across all 11 folds.
IV. EXPERIMENTAL EVALUATION & RESULTS
This section presents experiments evaluating EEG signals for cognitive workload assessment using the LOSO evaluation protocol across 11 participants and three cognitive tasks: IQ, MATH, and GAME. The primary objective is to identify the FOCUS configuration that provides the best overall trade-off between classification performance and computational cost. We systematically varied four design decisions: weight sharing between SSM blocks (D3), convolution type (D2), model width d (D4), and SSM state dimension (D4) to assess their individual contribution to classification performance and computational cost. Binary labels correspond to the predefined easy and hard task-difficulty conditions and do not represent direct subjective workload measurements. Results in Table I are reported separately for IQ, MATH, and GAME, as well as for ALL, which denotes a separate LOSO experiment on the full dataset containing samples from all three tasks. For ALL, a single model is trained in each LOSO fold using the full training-participant data, and task identity is not provided as an input to the model. ALL is therefore not an arithmetic average of the three task-specific results. Results are reported as mean ± std over 11 LOSO folds. Accuracy is computed as the overall proportion of correctly classified samples, while precision and F1-score are macro-averaged across the EASY and HARD classes, assigning equal weight to both classes. For the ALL setting, each architectural variant was compared with A1 using a two-sided Wilcoxon signed-rank test on the 11 paired participant-level accuracies ( ), with rank-biserial correlation reported as the effect-size measure. No correction for multiple comparisons was applied.
Weight sharing (D3). The baseline A1 (weight-shared encoder and bottleneck blocks) is compared with A2, which trains two independent Mamba-2 blocks. Removing weight sharing increases the parameter count from 0.04 M to 0.07 M, while GFLOPs remain at 0.11. The effect on per-task accuracy is uneven: A2 performs better on IQ (71.97% vs 67.42%), whereas A1 performs better on MATH (75.76% vs 69.70%), with similar GAME accuracy (76.14% vs 76.89%). For the ALL setting, A1 achieves 74.75% accuracy compared with 70.20% for A2, a descriptive difference of 4.55 percentage points. However, the paired Wilcoxon signed-rank test does not reach statistical significance (W = 12.5, p = 0.083), with a rank-biserial correlation of r = 0.62. Numbers of parameters in Table I are reported in millions and rounded to two decimal places.
Depthwise-separable convolution (D2). Replacing the depthwise-separable convolution with a standard Conv1d (A3) raises the parameter count from 0.04 M to 0.05 M and adds 0.02 GFLOPs. Accuracy differences across the three tasks are small descriptively: IQ increases from 67.42% to 69.70%, MATH decreases from 75.76% to 75.00%, and GAME is unchanged. The ALL accuracy difference between A1 and A3 is 0.13 percentage points and is not statistically significant (W = 17.0, p = 0.888, rank-biserial r = 0.06). The depthwise-separable factorization is therefore retained for its reduction in convolutional parameters, from 12,288 to 4,288, rather than on the basis of an established accuracy equivalence.
Model width (D4 — d). Three widths are compared: (A4), (A1), and (A5). Reducing the width to decreases ALL accuracy from 74.75% to 69.07%, a descriptive difference of 5.68 percentage points; however, this difference does not reach statistical significance ( , , rank-biserial ). Increasing the width to yields 75.00% ALL accuracy, only 0.25 percentage points above A1, with no statistically significant difference ( , , rank-biserial ), while increasing the parameter count from 0.04 M to 0.14 M and GFLOPs from 0.11 to 0.40. We therefore retain based on the observed cost-performance tradeoff.
SSM state dimension (D4 — ). Halving from 16 to 8 (A6) yields an ALL accuracy of 70.45% compared with 74.75% for A1, a descriptive difference of 4.30 percentage points. This difference does not reach statistical significance ( , , rank-biserial ). Lower accuracy is also observed for MATH (70.08% vs 75.76%) and GAME (69.32% vs 76.14%). Thus, although the results suggest sensitivity to the SSM state dimension in the present configuration, they do not establish a statistically significant performance difference or a specific temporal mechanism.
Final configuration. We adopt A1 as the final FOCUS architecture, with , , depthwise-separable convolution, and weight-shared encoder and bottleneck blocks. A1 achieves 74.75% ALL accuracy with 0.04 M parameters, 0.11 GFLOPs, and a model-forward latency of 0.08 ms per sample. Although A5 ( ) achieves a slightly higher ALL accuracy of 75.00%, the difference relative to A1 is only 0.25 percentage points and is not statistically significant ( , , rank-biserial ), while A5 requires 0.14 M parameters and 0.40 GFLOPs. A1 is therefore selected based on the cost-performance tradeoff.
V. COMPARISON WITH EXISTING WORK
Table II compares FOCUS with three published references, EEGNet [30], 1BT [21], and the multimodal framework proposed in [31], as well as with a plain Mamba-2 baseline evaluated in the present study. EEGNet and 1BT provide CNN- and Transformer-based EEG reference architectures, respectively, while the framework in [31] employs five modalities, namely ECG, EDA, RESP, , and EEG. The plain Mamba-2 baseline provides a direct state-space-model comparison for assessing the overall benefit of the proposed FOCUS design. The published EEGNet and 1BT results were obtained on the same EEG data under the same subject-independent LOSO protocol, while the multimodal framework employs the same participants and task protocol with the additional peripheral modalities. Plain Mamba-2 and FOCUS were evaluated in the present study. Following the convention established in [21], the mean score represents the unweighted average across all three tasks and all three evaluation metrics.
FOCUS achieves the highest accuracy on MATH and GAME among the evaluated models. On MATH, FOCUS reaches 75.76% accuracy, compared with 67.42% for plain Mamba-2, 67.05% for 1BT, 64.39% for the multimodal framework, and 63.64% for EEGNet. On GAME, FOCUS reaches 76.14% accuracy, compared with 70.83% for the multimodal framework, 69.70% for 1BT, 68.56% for Mamba-2, and 64.39% for EEGNet. IQ shows a different pattern, with the multimodal framework achieving the highest accuracy of 72.35%, followed by 1BT at 69.32%, Mamba-2 at 68.56%, FOCUS at 67.42%, and EEGNet at 65.15%. Thus, the advantage of FOCUS is primarily observed on MATH and GAME, while the multimodal framework achieves the highest performance on IQ. In the pooled ALL setting, FOCUS achieves 74.75% accuracy, compared with 62.88% for the multimodal framework, with a measured GPU model-forward latency of 0.08 ms per sample for FOCUS.
The five models exhibit different cost-performance profiles. EEGNet is the most computationally compact, with 0.01 M parameters and 0.02 GFLOPs, but has the lowest mean performance of 64.47%. 1BT achieves a mean score of 69.37% with 0.45 M parameters and 0.02 GFLOPs, while the multimodal framework reaches 69.77% with 5.61 M parameters and 0.36 GFLOPs. Plain Mamba-2 achieves 68.78% with 0.06 M parameters and 0.14 GFLOPs, whereas FOCUS achieves the highest mean score of 73.57% with 0.04 M parameters and 0.11 GFLOPs. Compared with plain Mamba-2, FOCUS has a 4.79 percentage-point higher mean score while using approximately 33% fewer parameters and 21% fewer GFLOPs. Compared with 1BT, FOCUS has a 4.20 percentage-point higher mean score while using approximately 11× fewer parameters, although 1BT has lower GFLOPs. Additionally, compared with the multimodal framework, FOCUS achieves a 3.80 percentage-point higher mean score while requiring substantially fewer parameters and GFLOPs. These results indicate that FOCUS provides a favorable trade-off between predictive performance and computational cost rather than minimizing computational cost alone.
VI. Discussion & Conclusion
An ablation across four design dimensions was used to select the final configuration. For weight sharing, the effect is task-dependent: A2 achieves higher IQ accuracy than A1, A1 achieves higher MATH accuracy than A2, and GAME performance is similar. In the ALL setting, A1 achieves 74.75% accuracy compared with 70.20% for A2, a descriptive difference of 4.55 percentage points, while also using fewer parameters. However, the paired Wilcoxon signed-rank test does not reach statistical significance (W = 12.5, p = 0.083, rank-biserial r = 0.62). Accordingly, these results do not establish weight sharing as a statistically significant performance improvement.
TABLE I: Ablation study over architectural configurations. A1 is selected based on the overall performance–cost trade-off.
| Config | Task | Configuration | Cost | Performance (%) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| d | DWSep | Shared | Params (M) | GFLOPs | Accuracy | Precision | F1 | |||
| A1 (selected) | IQ | 64 | 16 | ✓ | ✓ | 0.04 | 0.11 | |||
| MATH | 64 | 16 | ✓ | ✓ | ||||||
| GAME | 64 | 16 | ✓ | ✓ | ||||||
| ALL | 64 | 16 | ✓ | ✓ | ||||||
| A2 (no sharing) | IQ | 64 | 16 | ✓ | × | 0.07 | 0.11 | |||
| MATH | 64 | 16 | ✓ | × | ||||||
| GAME | 64 | 16 | ✓ | × | ||||||
| ALL | 64 | 16 | ✓ | × | ||||||
| A3 (std conv) | IQ | 64 | 16 | × | ✓ | 0.05 | 0.13 | |||
| MATH | 64 | 16 | × | ✓ | ||||||
| GAME | 64 | 16 | × | ✓ | ||||||
| ALL | 64 | 16 | × | ✓ | ||||||
| A4 (d = 32) | IQ | 32 | 16 | ✓ | ✓ | 0.01 | 0.03 | |||
| MATH | 32 | 16 | ✓ | ✓ | ||||||
| GAME | 32 | 16 | ✓ | ✓ | ||||||
| ALL | 32 | 16 | ✓ | ✓ | ||||||
| A5 (d = 128) | IQ | 128 | 16 | ✓ | ✓ | 0.14 | 0.40 | |||
| MATH | 128 | 16 | ✓ | ✓ | ||||||
| GAME | 128 | 16 | ✓ | ✓ | ||||||
| ALL | 128 | 16 | ✓ | ✓ | ||||||
| A6 () | IQ | 64 | 8 | ✓ | ✓ | 0.04 | 0.11 | |||
| MATH | 64 | 8 | ✓ | ✓ | ||||||
| GAME | 64 | 8 | ✓ | ✓ | ||||||
| ALL | 64 | 8 | ✓ | ✓ | ||||||
or demonstrate an implicit-regularisation mechanism; the shared design is retained based on the observed ALL performance and parameter efficiency.
The depthwise-separable convolution reduces the convolutional parameter count by relative to standard Conv1d, while the ALL accuracy difference between A1 and A3 is only 0.13 percentage points and is not statistically significant (, , rank-biserial ). We therefore retain the depthwise-separable design for its parameter efficiency without claiming accuracy equivalence or a specific separability mechanism. Reducing from 16 to 8 yields a 4.30 percentage-point lower ALL accuracy relative to A1, although the difference does not reach statistical significance (, , rank-biserial ). Increasing the model width from to yields only a 0.25 percentage-point higher ALL accuracy, with no statistically significant difference (, , rank-biserial ), while substantially increasing computational cost. These results support selecting the compact A1 configuration based on the observed cost-performance tradeoff rather than on statistically established performance differences. A1 is selected as the final FOCUS configuration because it provides the best overall performance–cost trade-off among the evaluated variants, achieving 74.75% ALL accuracy with 0.04 M parameters and 0.11 GFLOPs. Although A5 achieves a slightly higher ALL accuracy of 75.00%, this 0.25 percentage-point difference is not statistically significant () and requires substantially greater computational cost (0.14 M parameters and 0.40 GFLOPs). The selected A1 configuration has a measured GPU model-forward latency of 0.08 ms per sample.
The study has two main limitations: the dataset comprises 11 participants recorded in a single controlled laboratory environment, and the generalisability of the findings to clinical or operational settings with different EEG headsets or longer recording sessions has not been tested. Accordingly, the present results should be interpreted as pilot evidence of the feasibility and computational efficiency of the proposed architecture rather than as evidence of broad population-level generalization. The binary targets represent controlled easy/hard task-difficulty conditions used to induce differences in cognitive demand; therefore, the reported results should not be interpreted as direct estimation of subjective workload. The present study does not isolate the contribution of the fixed FFT decomposition relative to alternative EEG front-ends. Accordingly, the FFT stage should be interpreted as a parameter-free, physiologically motivated design choice rather than as an empirically established improvement over alternative representations. Future work should directly compare the fixed FFT decomposition with time-domain EEG without fixed band decomposition, learned temporal filters, wavelet-based representations, and learnable filterbanks, and evaluate FOCUS on larger and more demographically diverse cohorts. The present study intentionally focuses on EEG-only modeling to isolate the efficiency of the proposed architecture. Extending FOCUS to multimodal physiological sensing is a relevant direction for future work, particularly for social and companion robots in educational or healthcare settings [32], where recognition accuracy, model size, and inference time are all critical for practical deployment [33].
TABLE II: Comparison of FOCUS with published baselines and a plain Mamba-2 baseline evaluated in the present study, using the same dataset and subject-independent LOSO protocol.
| Model | Task | Params (M) | GFLOPs | Acc (%) | Prec (%) | F1 (%) |
|---|---|---|---|---|---|---|
| EEGNet [30] | IQ | |||||
| MATH | 0.01 | 0.02 | ||||
| GAME | ||||||
| mean* | 64.47 | |||||
| 1BT [21] | IQ | |||||
| MATH | 0.45 | 0.02 | ||||
| GAME | ||||||
| mean* | 69.37 | |||||
| Unified [31] | IQ | |||||
| MATH | 5.61 | 0.36 | ||||
| GAME | ||||||
| mean* | 69.77 | |||||
| Mamba-2 | IQ | |||||
| MATH | 0.06 | 0.14 | ||||
| GAME | ||||||
| mean* | 68.78 | |||||
| FOCUS (ours) | IQ | |||||
| MATH | 0.04 | 0.11 | ||||
| GAME | ||||||
| mean* | 73.57 |
- mean: unweighted average across IQ, MATH, and GAME and the three reported metrics.
Standard deviation was not reported for the task-specific results.
ACKNOWLEDGMENTS
The authors used large language model (LLM)-based tools for language editing and improvement. All scientific content, results, and conclusions are solely the work of the authors.
REFERENCES
[1] J. Hassard, K. R. Teoh, G. Visockaite, P. Dewe, and T. Cox, “The cost of work-related stress to society: A systematic review.” Journal of occupational health psychology, vol. 23, no. 1, p. 1, 2018.
[2] C. Anders, S. Moontaha, S. Real, and B. Arnrich, “Unobtrusive measurement of cognitive load and physiological signals in uncontrolled environments,” Scientific Data, vol. 11, no. 1, p. 1000, 2024.
[3] R. Fernandez Rojas, E. Debie, J. Fidock, M. Barlow, K. Kasmarik, S. Anavatti, M. Garratt, and H. Abbass, “Electroencephalographic workload indicators during teleoperation of an unmanned aerial vehicle shepherding a swarm of unmanned ground vehicles in contested environments,” Frontiers in Neuroscience, vol. Volume 14, 2020.
[4] E. Galy, J. Paxion, and C. Berthelon, “Measuring mental workload with the nasa-tlx needs to examine each dimension rather than relying on the global score: an example with driving,” Ergonomics, vol. 61, no. 4, pp. 517–527, 2018.
[5] R. L. Charles and J. Nixon, “Measuring mental workload using physiological measures: A systematic review,” Applied Ergonomics, vol. 74, pp. 221–232, 2019.
[6] N. Hirachan, A. Mathews, J. Romero, and R. F. Rojas, “Measuring cognitive workload using multimodal sensors,” in 2022 44th annual international conference of the IEEE engineering in medicine & biology society (EMBC). IEEE, 2022, pp. 4921–4924.
[7] M. A. Hogervorst, A.-M. Brouwer, and J. B. F. van Erp, “Combining and comparing eeg, peripheral physiology and eye-related measures for the assessment of mental workload,” Frontiers in Neuroscience, vol. Volume 8 - 2014, 2014.
[8] E. Debie, R. Fernandez Rojas, J. Fidock, M. Barlow, K. Kasmarik, S. Anavatti, M. Garratt, and H. A. Abbass, “Multimodal fusion for objective assessment of cognitive workload: A review,” IEEE Transactions on Cybernetics, vol. 51, no. 3, pp. 1542–1555, 2021.
[9] D. Tao, H. Tan, H. Wang, X. Zhang, X. Qu, and T. Zhang, “A systematic review of physiological measures of mental workload,” International Journal of Environmental Research and Public Health, vol. 16, no. 15, 2019.
[10] S. Hu and G. Sukthankar, “Multimodal fusion networks for workload modeling,” in 2024 International Conference on Machine Learning and Applications (ICMLA), 2024, pp. 320–324.
[11] M. H. R. Rabbani and S. M. R. Islam, “Deep learning networks based decision fusion model of eeg and fnirs for classification of cognitive tasks,” Cognitive Neurodynamics, vol. 18, no. 4, pp. 1489–1506, 2024.
[12] Y. Li, L. Zhu, A. Huang, J. Zhang, and P. Yuan, “Multimodal mbc-att: cross-modality attentional fusion of eeg-fnirs for cognitive state decoding,” Frontiers in Human Neuroscience, vol. Volume 19 - 2025, 2025.
[13] A. Gevins and M. E. Smith, “Neurophysiological measures of cognitive workload during human-computer interaction,” Theoretical Issues in Ergonomics Science, vol. 4, no. 1-2, pp. 113–131, 2003.
[14] W. Klimesch, “Eeg alpha and theta oscillations reflect cognitive and memory performance: a review and analysis,” Brain Research Reviews, vol. 29, no. 2, pp. 169–195, 1999.
[15] G. Borghini, L. Astolfi, G. Vecchiato, D. Mattia, and F. Babiloni, “Measuring neurophysiological signals in aircraft pilots and car drivers for the assessment of mental workload, fatigue and drowsiness,” Neuroscience & Biobehavioral Reviews, vol. 44, pp. 58–75, 2014, applied Neuroscience: Models, methods, theories, reviews. A Society of Applied Neuroscience (SAN) special issue.
[16] Y. Ke, H. Qi, F. He, S. Liu, X. Zhao, P. Zhou, L. Zhang, and D. Ming, “An eeg-based mental workload estimator trained on working memory task can work well under simulated multi-attribute task,” Frontiers in Human Neuroscience, vol. Volume 8 - 2014, 2014.
[17] Y. Qin and T. Bulbul, “Electroencephalogram-based mental workload prediction for using augmented reality head mounted display in construction assembly: A deep learning approach,” Automation in Construction, vol. 152, p. 104892, 2023.
[18] G. Siddhad, P. P. Roy, and B.-G. Kim, “Neural networks meet neural activity: Utilizing eeg for mental workload estimation,” in Pattern Recognition: 27th International Conference, ICPR 2024, Kolkata, India, December 1–5, 2024, Proceedings, Part XI. Berlin, Heidelberg: Springer-Verlag, 2024, p. 325–339.
[19] K. Kingphai and Y. Moshfeghi, “Mental workload assessment using deep learning models from eeg signals: A systematic review,” IEEE Transactions on Cognitive and Developmental Systems, vol. 17, no. 1, pp. 40–60, 2025.
[20] Y. Song, Q. Zheng, B. Liu, and X. Gao, “EEG conformer: Convolutional transformer for EEG signal decoding and visualization,” IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol. 31, pp. 710–719, 2023.
[21] S. Gkikas, C. Arzate Cruz, T. Kassiotis, G. Giannakakis, R. Fernandez Rojas, and R. Gomez, “One-block transformer (1bt) for eeg-based cognitive workload assessment,” in 2026 7th International Conference in Electronic Engineering & Information Technology (EEITE). Chania, Crete, Greece: IEEE, 2026, accepted for publication.
[22] J. M. Morales, J. F. Ruiz-Rabelo, C. Diaz-Piedra, and L. L. D. Stasi, “Detecting mental workload in surgical teams using a wearable single-channel electroencephalographic device,” Journal of Surgical Education, vol. 76, no. 4, pp. 1107–1115, 2019.
[23] Mohammed Atheef G. A. and O. S. Powar, “Estimating cognitive workload in robot-assisted surgery using time and frequency features from EEG epochs with random forest regression,” Scientific Reports, vol. 16, no. 1, p. 7624, 2026.
[24] O. E. Krigolson, H. Howse, M. R. Hammerstrom, A. Walzak, B. Wright, and K. G. Hecker, “Using EEG to assess cognitive fatigue in real time: A medical simulation study,” Medical Science Educator, vol. 35, no. 4, pp. 2099–2107, 2025.
[25] N. Beauchemin, P. Charland, A. Karran, J. Boasen, B. Tadson, S. Sénécal, and P.-M. Léger, “Enhancing learning experiences: EEG-based passive BCI system adapts learning speed to cognitive load in real-time, with motivation as catalyst,” Frontiers in Human Neuroscience, vol. 18, p. 1416683, 2024.
[26] E. Kutafina, A. Heiligers, R. Popović, A. Brenner, B. Hankammer, S. M. Jonas, K. Mathiak, and J. Zweerings, “Tracking of mental workload with a mobile EEG sensor,” Sensors, vol. 21, no. 15, p. 5205, 2021.
[27] A. S. Mathews, N. Hirachan, C. Joseph, M. Ghahramani, J. Lopez-Aparicio, and R. F. Rojas, “Eeg-based estimation of cognitive workload across multiple tasks,” in 2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2024, pp. 1–4.
[28] T. Dao and A. Gu, “Transformers are ssms: generalized models and efficient algorithms through structured state space duality,” in Proceedings of the 41st International Conference on Machine Learning, ser. ICML’24. JMLR.org, 2024.
[29] L. Kaiser, A. N. Gomez, and F. Chollet, “Depthwise separable convolutions for neural machine translation,” arXiv preprint arXiv:1706.03059, 2017. [Online]. Available: https://arxiv.org/abs/1706.03059
[30] V. Lawhern, A. Solon, N. Waytowich, S. Gordon, C. Hung, and B. Lance, “Eegnet: a compact convolutional neural network for eeg-based brain–computer interfaces,” Journal of Neural Engineering, vol. 15, 07 2018.
[31] S. Gkikas, C. Arzate Cruz, C. Joseph, G. Giannakakis, and R. Fernandez Rojas, “Towards a unified modality-agnostic multimodal framework for cognitive workload assessment,” in 2026 14th International Conference on Affective Computing and Intelligent Interaction (ACII). Puebla, Mexico: IEEE, 2026, accepted for publication.
[32] E. C. Montiel-Vazquez, C. A. Cruz, S. Gkikas, T. Kassiotis, G. Giannakakis, and R. Gomez, “Efficient emotion-aware iconic gesture prediction for robot co-speech,” in 2026 7th International Conference in Electronic Engineering & Information Technology (EEITE), 2026, pp. 1–5.
[33] S. Gkikas, C. A. Cruz, Y. Fang, L. Cao, M. U. Khan, T. Kassiotis, G. Giannakakis, R. F. Rojas, and R. Gomez, “A lightweight transformer for pain recognition from brain activity,” in 2026 7th International Conference in Electronic Engineering & Information Technology (EEITE), 2026, pp. 1–7.