Manuscript Offprint

arXiv:2610.32377

Sam-Correction: Fully Adaptive Label Noise Reduction for Medical Image Segmentation

Takuro Shimaya, Masahiro Saiko

ABSTRACT

The quality of the teacher label has a dramatic impact on the outcome of the machine learning process. Medical image segmentation often suffers from a noisy ground truth (GT) mask due to difficulties in consistent annotation. Although a recent study has proposed a promising method to curate the noisy GT mask, this requires additional well-curated GT masks that are not always accessible without the aid of multiple medical experts. As an alternative, we propose SAM-Correction, which utilizes a foundation model to correct the noisy GT mask in a fully adaptive manner instead of manually preparing well-curated masks. In our approach, we progressively mitigate label noise via the segment anything model (SAM), where prompts are given from another segmentation network that we train concurrently. Experiments with various types of label noise derived from actual human annotations demonstrate that SAM-C achieves precise noise reduction and high-performing segmentation models trained thereby. Our method paves the way for robust model training even when clean labels are entirely unavailable.

Index Terms— Label noise, Foundation model, Lung CT

1. INTRODUCTION

Noisy mask annotations are known to degrade the performance of deep neural networks (DNN) for image segmentation tasks. This problem is particularly evident in medical images, where noise can originate from a lack of uniqueness in object boundaries, the necessity of expertise, or the limited time that annotators can devote to the task [1, 2]. Label noise problems themselves have historically been tackled in the context of classification tasks [3, 4]. While this approach is applicable to image segmentation by assuming an independent classification problem for each pixel, its contribution is limited due to lacking consideration of the spatial correlation of noise [2]. At present, strategies dedicated to the image segmentation context have made relatively little progress.

Yao et al. recently proposed a method specific to noisy mask annotations based on a Markov model [2]. In their method, spatial correction (SC) is utilized to correct the noisy ground truth (GT) mask for training a DNN, assuming that noisy GT masks are biased, i.e., that they expand or shrink from clean GT masks by a typical length. The typical length is defined as a bias parameter and estimated by comparing the prediction from a DNN trained by noisy GTs with the corresponding well-curated clean GT prepared manually. In this paper, we refer to the above process as true validation (TV). With TV using additionally prepared clean GTs, SC has outperformed existing methods while leaving the following concern. For medical images, clean GTs are typically determined by majority voting among several noisy GTs annotated by each expert [1]. Such clean GTs reflecting consensus among multiple experts are not always accessible due to the high annotation cost. Moreover, SC would be sub-optimal because it attempts to treat noise uniformly with the single bias parameter.

Instead of preparing additional clean GTs, we utilize a foundation model to recover clean labels only from noisy GTs. Specifically, we adopt the segment anything model (SAM) [5], which achieves zero-shot segmentation by the user's prompts (e.g., boxes and masks) to specify which object to segment in a given image. With the aid of SAM, our proposed method, SAM-Correction (SAM-C), iteratively reduces label noise along with training a segmentation DNN. SAM-C aims to reproduce clean GTs akin to those obtained by majority voting, where SAM generates the most reasonable mask using generic image features and prompts from the trained DNN. Unlike SC, our method allows fully adaptive noise correction without additional clean GTs and the bias parameter. Our experiments using two datasets with non-synthetic noise yielded the following insights:

  1. SAM-C outperformed SC in terms of the accuracy of segmentation models under noisy teacher labels.

  2. SAM-C achieved precise noise reduction from low-quality annotations, while SC failed in some cases.

  3. Our fully adaptive framework does not require additional well-curated GTs, and is applicable even when one cannot enlist the help of multiple clinical experts.

References (12)