Manuscript Offprint

arXiv:2610.32674

EMG Tokenization Preserves Movement Information at a Fraction of the Bitrate

Raul C. Sîmpetru, Amin Olamazadeh, Devon Rohlf, Vlad Cnejevici, Alessandro Del Vecchio

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Raul C. Šimpetru D◯\textcircled{D}, Amin Olamazadeh D◯\textcircled{D}, Devon Rohlf D◯\textcircled{D}, Vlad Cnejevici D◯\textcircled{D}, and Alessandro Del Vecchio D◯\textcircled{D}

Abstract—Wireless electromyography (EMG) interfaces must balance electrode coverage against transmission bandwidth. Here, we show that compact EMG tokens substantially reduce payload while retaining information for three-dimensional hand-pose decoding. We evaluate two causal tokenizers fitted without pose labels: an encoder pretrained to reconstruct EMG spectra and one based on SPAR, an engineered spectral–spatial representation of neighbouring electrodes. In personalized, within-session experiments with 320-channel EMG from nine participants, we compare tokenized and continuous features using matched decoder architectures and training procedures. Averaged across decoders, tokenization changed mean error by +0.01 mm for SPAR (95% confidence interval: -0.12 to 0.14) and +0.45 mm for the learned representation (0.10 to 0.82). Both increases met a 1 mm non-inferiority criterion. Stored token arrays reduced payloads 41-fold relative to raw EMG and 36-fold relative to continuous SPAR features. On sampled windows of the public emg2pose benchmark's test partition, absolute differences in mean error between learned tokens and continuous features were below 0.05 mm across 176 participants and in the subset of 20 participants unseen during training. Electrode coverage, calibration, and unseen recordings affected SPAR decoding more than quantization did. In a computational benchmark, optimized SPAR generated tokens for 63 channels within 20 ms on a Cortex-M55 microcontroller. These findings support tokenization as a compact interface between wearable sensing and movement decoding, allowing decoders to be updated while the wearable encoder and transmitted representation remain fixed.

Index Terms—electromyography, hand-pose estimation, vector quantization, representation learning, compression

I. INTRODUCTION

SURFACE electromyography (sEMG) is a non-invasive method for measuring muscle activity [1] that is increasingly moving beyond laboratory settings, driven in part by its ease of use and growing commercial interest, from myoelectric prostheses [2] and wireless high-density amplifiers [3] to wristbands for computer input [4, 5].

Wireless sEMG wearables [3, 7, 8, 9] trade electrode coverage against transmission bandwidth, even though motor unit activity can differ between regions of a single muscle [10]. Compressing multichannel recordings could reduce bitrate while retaining information useful for movement decoding (Fig. 1).

This work was supported in part by the European Research Council (ERC) through the GRASPAGAIN project under Grant 101118089 and in part by the German Federal Ministry of Research, Technology and Space (BMFTR) through the BIONIK project under Grant 16SV9639, the EMGRoll project under Grant 16SV9306, and the NOE-EMY project under Grant 16SV9246, all to A. Del Vecchio. (Corresponding author: Alessandro Del Vecchio)

The authors are with the Department of Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91052 Erlangen, Germany

Code is available at https://github.com/NsquaredLab/MyoJi.

Electromyography (EMG) interfaces typically transmit either raw signals or continuous feature representations [5, 7, 11, 12, 13]. An alternative is to encode EMG signals as discrete tokens that index vectors in a learned codebook. At the receiver, these vectors are retrieved and passed to the pose decoder. Vector quantization (VQ) has previously been explored for EMG signal reconstruction [14], while more recent approaches have introduced learned token representations for general time series [15] and biosignals [16, 17]. In the context of hand-pose decoding, VQ-MyoPose uses vector quantization to encode ground-truth joint-angle trajectories and trains an EMG model to predict the resulting pose tokens [18]. EMG tokenization separates wearable encoding from receiver-side task decoding.

We examine how converting continuous EMG features into discrete tokens affects hand-pose decoding accuracy, transmission bandwidth, memory requirements, and computational cost. We compare two approaches: a temporal encoder, shared across channels and pretrained to reconstruct EMG spectra, followed by vector quantization (Fig. 2), and SPAR, which applies vector quantization to an engineered Spectral–SpAtial Representation. 1^{1} Both are fitted without pose labels, and separate models are then trained to predict three-dimensional (3D) hand kinematics. To assess the effect of quantization, we compare each tokenized representation with its continuous counterpart using the same decoder architecture and training procedure, with separate models fitted to each representation. We evaluate both tokenizers on high-density EMG (HD-EMG) synchronized with 3D hand kinematics from nine participants [12, 19], using personalized decoders trained and tested within each participant's recording session. An adapted end-to-end waveform convolutional neural network (CNN) based on our previous work [11, 12] provides a raw-EMG reference. The learned tokenizer is also evaluated on emg2pose [5], a public benchmark of 16-channel wrist EMG and motion-captured hand poses from 193 participants, including participants unseen during training. We also measure payload, memory, decoder cost (size and latency), and tokenizer execution time on a Cortex-M55 microcontroller (Section S-I).