Manuscript Offprint

arXiv:2610.32730

Cross-Architectural Feature Fusion for Coronary Artery Stenosis Detection in X-ray Angiography

Haobo Zhu, Mojtaba Lashgari, Jason Chai, Giovanni Luigi De Maria, Vicente Grau, Abhirup Banerjee

Haobo Zhu 1^{1}[0009-0000-1735-3900], Mojtaba Lashgari 1^{1}[0000-0002-5307-3495], Jason Chai 2,3^{2,3}[0000-0002-7398-9564], Giovanni Luigi De Maria 2,3^{2,3}[0000-0003-3572-1855], Vicente Grau 1^{1}[0000-0001-8139-3480], and Abhirup Banerjee 1,2^{1,2}[0000-0001-8198-5128]

1^{1} Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom

abhirup.banerjee@eng.ox.ac.uk

2^{2} Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom

3^{3} Oxford Heart Centre, Oxford University Hospitals NHS Trust, Oxford, United Kingdom

Abstract. Coronary artery disease remains a leading cause of mortality, with stenosis detection from invasive X-ray Coronary Angiography (XCA) critical for diagnosis. Manual interpretation is time-consuming, subjective, and variable, especially under low contrast and vessel overlap. Existing deep learning methods often rely solely on detection or segmentation, limiting performance. We propose a hybrid framework, Fusion-YOLOv11-L, combining a YOLOv11-L detector with a pretrained UNet++ via a channel attention gating module. This enables fusion of semantic and vessel-aware structural features, improving localisation of stenotic regions. The UNet++ is pretrained on ARCADE vessel segmentation dataset to provide anatomically informed representations. Experiments on the relabeled ARCADE (ARCADE*) dataset show improved performance over YOLOv11-L, achieving AP@50 of 0.585 and F1-score of 0.596. Cross-domain evaluation on a dataset from the Oxford Acute Myocardial Infarction (OxAMI) Study reveals performance degradation due to domain shift, mitigated using test-time adaptation and augmentation. Test-time augmentation improves AP@50 from 0.434 to 0.480, indicating better generalisability. These results show that cross-architecture feature fusion and lightweight adaptation improve robustness and generalisability of automated stenosis detection in XCA.

Keywords: X-ray Coronary Angiography · Coronary Artery Disease · Stenosis Detection · YOLO · Convolutional Neural Networks.

1 Introduction

Coronary Artery Disease (CAD) remains the leading cause of mortality worldwide, accounting for nine million deaths annually and affecting a substantial portion of the global population [18]. The disease is primarily driven by atherosclerosis.

H. Zhu et al.

sis, a progressive process involving plaque accumulation within coronary arteries, leading to luminal narrowing (stenosis) and reduced myocardial perfusion [10].

Invasive coronary angiography, also known as X-ray Coronary Angiography (XCA), is the gold standard for visualising coronary arteries and identifying stenotic regions. During clinical procedures, clinicians visually inspect angiographic videos acquired from multiple projections to detect abnormalities [12][12]. However, this process is time-consuming and heavily dependent on operator expertise, which can lead to missed lesions or inconsistent interpretation [12][12].

This has led to increasing interest in automated methods for detecting stenosis directly from angiographic data. Deep learning approaches have shown strong potential in image-based detection tasks, offering more consistent and objective analysis compared to manual assessment. Unlike traditional methods that rely on vessel segmentation or handcrafted features, these models learn directly from image data, making them more adaptable to complex imaging conditions. Recent works have explored multiple strategies to improve detection performance. Danilov et al. [4] highlighted the trade-off between performance and time efficiency by exploring the performance and runtime of different detection architectures, showing that high-capacity models improve performance while lightweight models enable faster inference. Avram et al. [2] developed a multi-stage model with a RetinaNet detector, trained on large-scale real-world data, demonstrating strong generalisation for clinical use. Data scarcity and class imbalance remain key challenges. Seo et al. [19] addressed this using diffusion-based inpainting to synthesise realistic lesions, improving performance in limited-data settings. Pascual et al. [16] further improved YOLO-based detectors through hyperparameter optimisation, enhancing both accuracy and efficiency. Li et al. [13] used temporal features by incorporating angiographic sequences, which improved YOLO robustness to noise and variability. Molenaar et al. [15] demonstrated performance of a U-Net-based model on multi-centre datasets, achieving robust performance across clinical settings. Albasrawi et al. [1] improved sensitivity to subtle lesions using spatial and frequency attention, while Lalinia et al. [11] proposed a Swin UNETR-based model to capture global context efficiently.

While several existing approaches rely on detection or segmentation-based strategies for coronary stenosis localisation, there remains a lack of investigation into the explicit use of segmentation-derived features as prior information to guide and enhance the performance of detection networks. This study explores the potential of segmentation feature fusion for stenosis detection by fusing the segmentation features from pretrained UNet++ [21] into the backbone of a YOLOv11-L [7]. The key contributions can be summarised as follows: (1) a lightweight hybrid detection-segmentation framework that integrates a pretrained UNet++ features into a YOLOv11-L backbone, enabling the combination of object-level detection and vessel-aware representation learning; (2) a Channel Attention Gating (CAG) module that performs dual-source attention, allowing selective fusion of detection-driven and anatomically meaningful features; and (3) an improved cross-domain generalisability on out-of-distribution (OOD) data compared to a detection-only baseline model.

References (20)

  • Modified YOLOv8x model for coronary stenosis detection and troponin risk stratification
  • Cathai: fully automated coronary angiography interpretation and stenosis estimation
  • Point-cloud method for automated 3D coronary tree reconstruction from multiple non-simultaneous angiographic projections
  • Real-time coronary artery stenosis detection based on modern neural networks
  • Sigmoid-weighted linear units for neural network function approximation in reinforcement learning
  • Squeeze-and-excitation networks
  • Ultralytics YOLO11
  • Ultralytics YOLOv8
  • YOLOv11: An Overview of the Key Architectural Enhancements
  • 2019 esc guidelines for the diagnosis and management of chronic coronary syndromes: The task force for the diagnosis and management of chronic coronary syndromes of the european society of cardiology (esc)
  • Stenosis detection of coronary arteries in x-ray angiography images using swin unetr with self-supervised pre-training approach and peft strategy
  • Patient-specific in silico 3D coronary model in cardiac catheterisation laboratories
  • LT-YOLO: long-term temporal enhanced yolo for stenosis detection on invasive coronary angiography
  • Adaptive batch normalization for practical domain adaptation
  • JACC: Advances 4(12, Part 2), 102360
  • Hyperparameter optimization of yolo models for invasive coronary angiography lesion detection and assessment
  • Dataset for automatic region-based coronary artery disease diagnostics using X-ray angiography images
  • Global burden of cardiovascular diseases and risk factors, 1990–2019: Update from the GBD 2019 study
  • Diffusion-based user-guided data augmentation for coronary stenosis detection
  • UNet++: A nested U-Net architecture for medical image segmentation