Manuscript Offprint
arXiv:2610.32816Sounding Surgical Instrument Localisation through Audio-Visual Correspondence
Abstract
Purpose: Surgical scene understanding is a prerequisite for context-aware and intelligent systems in the operating room. Current methods rely mostly on visual data, while acoustic sensing has shown potential to provide complementary information on surgical activity. First approaches for the localisation of surgical activity relied on microphone arrays and acoustic beamforming. This work investigates whether the active instrument can be localised from a single microphone and a camera by learning the correspondence between the appearance and the sound of surgical instruments, without annotating its position.
Methods: We adapt weakly supervised audio-visual localisation, which learns from the co-occurrence of image and sound, to the surgical setting. We record simulated surgical actions, sawing, drilling, and chiseling, and train the model on these recordings without any spatial annotation to produce a heatmap over the sounding tool. We extend the training objective by two terms: a silence term, which suppresses the output for silence and background noise, and a composite term, which trains the model to select the sounding one of two visible instruments.
Results: The model localises the active instrument on an independent corpus recorded with a different camera and microphone, in which instrument positions were obtained by optical tracking. It separates tool activity from silence and background noise and can attribute sound correctly when two tools are present. Ablations show that the silence and area terms are required for detecting activity, and the composite term for selecting between instruments.
Conclusion: Audio-visual correspondence learned from in-domain recordings connects the sound of a surgical action to the instrument that produces it, using a single microphone and a camera. This proof of concept introduces a novel paradigm that enables the detection and localisation of surgical activity without manual localisation annotations.
Keywords: Surgical Scene Understanding, Sound Source Localisation, Audio-visual Correspondence, Weakly Supervised Learning, Multimodal Data
1 Introduction
Over the past decades, Computer Assisted Surgery (CAS) has evolved from the first image-guided navigation systems into a broad technological spectrum that aims at improving the accuracy, safety, and reproducibility of surgical procedures [1]. A central building block towards the next generation of intelligent systems in the operating room (OR) is a fine-grained understanding of the surgical scene, its workflow, and the actions performed within it [2]. The community has addressed this need, e.g., through automated surgical phase recognition from video [3] and through semantic scene graphs that model the interactions between staff, patient, and objects [4]. More recently, surgical digital twins have been proposed as interpretable, geometry-aware representations of the surgical scene that can serve as an internal model for robots and agentic systems [5].
Current approaches for surgical scene understanding, however, rely almost exclusively on the visual modality. Vision-based pipelines require free line-of-sight and are therefore sensitive to occlusions by staff, drapes, and equipment, and they cannot directly capture the physical signature of instrument-tissue interaction, e.g., whether a power tool is running and in contact with the anatomy, which is straightforward to perceive in the acoustic domain. Acoustic sensing has consequently been shown to complement vision in a variety of interventional applications, such as tissue characterisation during needle insertion [6], error prevention in orthopaedic drilling [7], implant insertion monitoring [8], and event detection in the OR [9]. While these works demonstrate that surgical sound carries rich semantic information about what is happening and when, they do not reveal where in the surgical field it is happening.
To bridge this gap, sound source localisation (SSL) based on acoustic beamforming with a phased microphone array has recently been introduced to surgery to localise active surgical tools and to fuse acoustic activity maps into dynamic 3D representations of the surgical scene [10, 11]. Although these works demonstrated the potential of spatial acoustic information for surgical scene understanding, beamforming-based SSL comes with considerable limitations that hinder its translation into clinical practice: the microphone arrays are bulky and expensive and the computation of acoustic heatmaps is demanding and limits real-time capabilities. Moreover, as beamforming localises the physical sound source, only a part of the instrument is detected (e.g., the engine of a power drill or the point of hammer impact during chiselling), and the resulting maps are frequently corrupted by artefacts such as acoustic reflections or multiple spurious peaks. Finally, detection and localisation are treated as two separate stages [11], rather than being solved jointly.
A promising alternative is to exploit the natural co-occurrence of sound and vision. Audio-visual sound source localisation (AV-SSL) methods learn to associate sounds with the visual objects that produce them, mimicking how humans infer which object in a scene is responsible for a sound. Since audio-visual correspondence arises naturally in video, these methods can be trained in a self- or weakly supervised manner without costly spatial annotations. In the general computer vision domain, large-scale benchmarks such as VGG-SS [12] have driven the development of a variety of approaches based on contrastive learning [12–14]. For surgery, this paradigm has the potential to overcome the limitations of beamforming-based SSL: the hardware is reduced to a single consumer-grade camera with a microphone, inference requires only a single forward pass of a neural network, and the full sounding object rather than only its physical emission point is localised, while detection and localisation are addressed jointly. To date, however, AV-SSL has not been investigated in the surgical domain. In addition, the surgical setting introduces challenges for general-purpose AV-SSL methods: instruments are frequently visible but silent and multiple similar-looking tools are present in the scene at the same time.
In this work, we present the first investigation of learned audio-visual correspondence for the localisation of surgical activity. Our contributions are threefold:
-
We introduce a novel audio-visual dataset of simulated surgery captured in a realistic operating room, providing weak, activity-level labels for image-sound pairs that enable the training of weakly supervised AV-SSL methods.
-
We provide the first proof-of-concept for AV-SSL in surgery, demonstrating that audio-visual correspondence can be leveraged to detect and localise active surgical instruments without microphone arrays.
-
We propose an AV-SSL method built upon SLAVC [13] and explicitly incorporate silence and multi-tool scenarios through custom loss terms.
In computer vision, AV-SSL replaces physical localisation with learned audio-visual correspondence. Models are trained on unlabelled or weakly labelled video to predict

Fig. 1 Schematic overview of the method. Training adds two generated samples, a pair with negative audio (silence, background noise) and a composite of cropped halves with different instruments. Cosine similarity between each cell of the visual embedding grid and the audio embedding yields the heatmap S, which is upsampled at inference time.
which image regions emit the sound [12]. SLAVC [13] showed that earlier methods overfit and fail on negative samples, i.e., silent objects and off-screen sounds, and proposed regularisation strategies and an evaluation protocol that accounts for these cases. Dedicated strategies to incorporate silence and noise into the training process have been proposed to make the detections more robust [15]. Furthermore, pretrained vision-language representations [14] or training-free meta-reasoning with multimodal large language models [16] have been applied to the task of AV-SSL. These methods have so far been developed and evaluated exclusively on general domains. In the OR, instruments are often visible but inactive, multiple similar tools are present simultaneously, and background noise is substantial. It therefore remains unclear whether learned audio-visual correspondence transfers to surgery, which is the question we address in this work.
3 Methodology
We localise surgical activity in an RGB-image from mono-audio. We fine-tune SLAVC [13], a weakly supervised sound source localisation model. The model outputs a heatmap indicating the location of the sound source. We propose to extend the training objective to obtain flat heatmaps for synthetic silence or OR background noise, and enable the model to choose between instruments when more than one are visible. Figure 1 gives an overview of the method.
3.1 Data
We use two corpora (Table 1) recorded in the same operating room (OR-X, Balgrist University Hospital) and contain sequences of simulated surgical drilling, sawing and chiseling on a plastic bone model (SYNBONE AG, Zizers, Switzerland). The model is trained and developed on a newly recorded action camera corpus and tested for localisation on the public acoustic camera corpus of Hein et al. [11].
Table 1 Data splits. Bounding boxes are used for model selection and evaluation only.
| Split | Corpus | Sequences | bounding boxes | Used for |
|---|---|---|---|---|
| Training | action camera | 45 | × | training |
| Validation | action camera | 6 | ✓ | validation |
| Two-tool test | action camera | 3 | ✓ | test selection, silence |
| Localisation test | acoustic camera | 21 | ✓ | test localisation |
Action camera corpus The corpus contains 54 sequences of about one minute each recorded with a GoPro HERO13 Black and a RØDE VideoMic VMMC+ and covers three operators and both static and hand-held camera viewpoints. 36 of the 54 sequences were recorded in an operating room, the remaining 18 in a corridor for variation in the surroundings. In the static sequences the camera is centered on the operating site, so that the active instrument lies in the central half of the image. In the three test sequences, a second, idle instrument is visible next to the active one. Bounding boxes were annotated on the validation and test sequences only. The data will be made publicly available upon acceptance.
Acoustic camera corpus The public corpus from [11] contains 21 sequences of 20 s, recorded with a ZED 2i RGB-D camera and a Ring48 acoustic camera (gfai tech GmbH, Berlin, Germany) while the instruments were tracked with a FusionTrack 500 (Atracsys, Puidoux, Switzerland). From these recordings, the model receives only the left RGB image of the stereo camera and the audio of on microphone of the acoustic camera. The acoustic heatmaps and the tracking data are not used as model input. Ground-truth boxes are only used at test time and obtained by projecting 3D instrument models into the image based on the infrared tracking and drawing a box around the segmentation masks.
3.2 Model
Our model takes a single RGB-frame and a 3 s mono audio clip and outputs a heatmap over the frame localising the sounding tool or a flat heatmap for silence or background noise. It builds on SLAVC [13], an AV-SSL model with separate encoders for image and audio. We replace its visual encoder and extend its training objective by a silence term and a composite term. Training requires only class labels on sequence level and no spatial supervision.
Input A sample consists of a video frame and the 3 s of audio centered on it. The frame is resized to px. The audio is resampled to 16 kHz, scaled to a common RMS level, and converted to a log-power spectrogram. At inference, the sample is passed to the model without further processing. During training, we augment both modalities. Frames are randomly cropped, horizontally flipped, color-jittered, and random cutouts. The audio clips are shifted in time and pitch, scaled in level, and randomly reverberated and low-pass filtered. In addition, random frequency bands and time intervals of the spectrogram are masked. During training, two further kinds of input are generated, negative audio clips and composite frames, which are described with the silence and the composite term below.
Architecture We build on SLAVC [13], which embeds audio clips and the grid cells of a frame with two encoders and computes the heatmap from the similarity between audio clip j and grid cell p of frame i. We keep its audio encoder, projection layers, and momentum encoders and change the visual branch and the training objective. The grid of SLAVC at px is too coarse for instruments that cover only a small part of the frame, so we raise the input resolution to px. We further replace the ResNet-18 visual encoder by DINOv2 ViT-S/14 with registers [17, 18], which generalised better to the validation sequences and to the selection between two instruments (Sect. 4), average-pool its patch tokens to a grid, and map them with a linear layer to the input dimension of the SLAVC projection. Both encoders start from pretrained weights.
Contrastive term SLAVC condenses the similarities between frame and audio clip into a matching score , which is high if one grid cell of the frame matches the clip better than the other cells of the frame and better than the other clips of the batch [13]. Only the best cell enters the score, so no spatial annotation is needed. All loss terms are defined per training sample and averaged over the batch. In contrast to SLAVC, which treats all other clips of a batch as negatives, we use supervised contrastive learning with the known instrument labels, since with only three classes about a third of these negatives would be of the same class as the anchor. With the label of sequence and the positives ,
Silence and area terms The contrastive term only ranks pairs within a batch and is invariant to a shift of all similarities, so it cannot express that nothing is sounding. Juanola et al. [15] address this by pairing each image with digital silence and with Gaussian noise and penalising the squared norm of the resulting similarity map. We adopt this term and extend the negative audio to background noise recorded in the operating room. In every training step, we draw for each frame i of the batch a clip at random from a bank of Gaussian noise, recorded background noise, and digital silence, compute the heatmap of frame i for this clip, and penalise any non-zero cosine similarity.
The clips are augmented like the tool audio and attenuated by a random gain of up to 24 dB, so that the signal level is no cue. In our setting, this term alone did not separate silence from tool activity. We therefore pair it with an area term (2), where is the logistic function. Similar area regularisers are used to keep the activated region compact [19]. Here, its main effect is on the magnitude of the heatmap. It drives the similarity of all cells that the contrastive term does not need away from zero. With both terms, the heatmap has a large magnitude for tool audio and stays close to zero everywhere for silence and noise, while its maximum marks the source in both cases.
We use this difference in magnitude to detect tool activity. The mean squared value of the heatmap serves as activity score.
Composite term In single-instrument sequences the instrument is the only candidate, so the model can satisfy the contrastive term by highlighting any visible instrument, regardless of the audio. To pose the question which of two instruments is sounding, we build composite frames during training. With probability 0.5, a training frame in which the instrument lies in the central half of the image is combined with a frame that shows a different instrument in another setup. The central halves of the two frames are placed side by side or one above the other, in random order. The audio of the first frame is kept, so that only one of the two visible instruments is sounding. On the set C of composites in a batch, the maximum of the heatmap in the half of the sounding instrument, , must exceed the maximum in the other half, , by a margin ,
Training The four terms are combined into
with , , and , determined empirically. We fine-tune the last two blocks of the visual encoder, the last stage of the audio encoder, and the projection layers. All other weights stay frozen. The checkpoint with the highest IoU on the validation sequences is selected. Architectural details and hyperparameters are documented in the code that will be made publicly available upon acceptance.
4 Experiments
All metrics are computed on the heatmap of a frame and an audio clip, upsampled to px. We train three models with different seeds and report mean and standard deviation. The ablations are single runs with the seed of the first model.
Localisation. We test on the 853 annotated frames of the acoustic camera corpus. Each heatmap is normalised to by its own minimum and maximum, and the pixels above a threshold form the predicted region. The bounding box around its largest connected component is compared to the ground truth by intersection over union (IoU). The threshold is determined empirically on the validation set for each model separately, including the baselines and the ablations. In addition, we report the distance in pixels between the maximum of the heatmap and the center of the ground-truth box, at a resolution of px. We compare against SLAVC and ACL-SSL with their published weights. Table 2 summarises the results.
Detection. We test the activity score, the mean squared value of the heatmap, on the 111 annotated frames of the two-tool test sequences. Each frame is paired with its own audio as positive and with each of 17 clips of 3s of operating room background noise as negatives, cut from two recordings held out from training. We report the area under the ROC curve (AUC), which rates the ranking of the scores and
Table 2 Localisation on the acoustic camera corpus (853 frames). IoU and median distance between the heatmap maximum and the center of the ground-truth box in px at , per instrument and over all frames. Ours: mean standard deviation over three seeds.
| Model | IoU | Distance [px] | ||||||
|---|---|---|---|---|---|---|---|---|
| Saw | Chisel | Drill | All | Saw | Chisel | Drill | All | |
| SLAVC [13] | 0.03 | 0.01 | 0.05 | 0.03 | 70 | 65 | 75 | 69 |
| ACL-SSL [19] | 0.04 | 0.02 | 0.02 | 0.03 | 47 | 28 | 77 | 37 |
| Ours | 0.46 ± 0.04 | 0.14 ± 0.02 | 0.50 ± 0.04 | 0.36 ± 0.03 | 9 ± 1 | 23 ± 8 | 12 ± 1 | 12 ± 2 |

Fig. 2 Heatmaps of the proposed model on the acoustic camera corpus. Green: ground-truth box. Left: drill. Middle: chisel, where the model responds to the hand swinging the hammer as well as to the chisel (Sect. 5). Right: saw, where the empty hand of the assistant also receives part of the response.
does not depend on a threshold. The score separates tool activity from background noise completely, with an AUC of 1.00 for all three seeds and all three instruments. The lowest score of a tool frame lies between 671 and 808 and the highest score of a background clip between 460 and 571, depending on the seed.
Tool selection. The two-tool test split contains frames in which besides an active instrument another hand-held idle tool is visible, both annotated with a bounding box (Figure 3). Each frame is evaluated with its own audio (matched) and with audio of the idle instrument's class (swapped). A prediction is correct if the maximum of the heatmap inside the box of the instrument that matches the audio exceeds that inside the other box. We report the accuracy for both conditions. With the frame's own audio, the active instrument is correctly recovered in of the frames. With the audio of the idle instrument's class, inactivity is detected in of the samples (mean and standard deviation over three seeds).
Ablations Table 3 analyses the contributions of each training loss and the choice of the visual encoder. The silence term and the area term are required for detection (AUC) and the composite term for selection (matched and swapped). The ResNet-18 vision encoder shows similar IoU, but is weaker on selecting between two instruments.

Fig. 3 One frame of a two-tool test split under background noise (left), matched saw audio (middle), and swapped to chisel audio (right). Green: active saw, grey: idle chisel. For visualisation purposes, each heatmap is shown as the deviation from its mean, on one common colour scale.
Table 3 Ablation of the loss terms and the visual encoder. The contrastive term is always used. First row: the proposed model as in Table 2, mean over three seeds. The other rows are single runs.
| Visual encoder | Localisation | Detection AUC | Selection | |||||
|---|---|---|---|---|---|---|---|---|
| IoU | Dist. px | matched | swapped | |||||
| ✓ | ✓ | ✓ | DINOv2 | 0.36 | 12 | 1.00 | 0.93 | 0.87 |
| ✓ | ✓ | × | DINOv2 | 0.35 | 9.4 | 1.00 | 0.67 | 0.46 |
| ✓ | × | ✓ | DINOv2 | 0.29 | 10.6 | 0.79 | 0.97 | 0.98 |
| × | ✓ | ✓ | DINOv2 | 0.36 | 9.9 | 0.04 | 0.87 | 0.96 |
| × | × | × | DINOv2 | 0.15 | 16.8 | 0.36 | 0.48 | 0.74 |
| ✓ | ✓ | ✓ | ResNet-18 | 0.36 | 7.2 | 1.00 | 0.81 | 0.70 |
5 Discussion
This paper presents a novel approach that enables the detection and localisation of surgical tool activity in surgery at a low cost, leveraging the natural co-presence of video and audio as training signal. Trained on about an hour of video from an action camera with a single microphone, labelled only with the instrument per sequence, the model localises the sounding instrument on an independent corpus recorded with different cameras and microphones in another room. The spatial information, the expensive part of manual annotation, is learned from the correspondence, and the instrument labels are cheap to annotate and could be replaced by an audio classifier in future work [11]. We show that the tested baselines, which are pretrained on general-domain video recordings, do not transfer to the operating room setting, requiring in-domain learning. The data needed for this training is however cheap to record.
Our evaluation shows that the saw and drill can be localised with a median distance of about 10 px to the center of the ground-truth box, about 5 % of the frame width. The inferior results for surgical chiseling are partly a matter of ground truth. The heatmap responds to the hand that swings the hammer rather than to the chisel alone. The model associates the sound with the pose rather than with the instrument, whereas the ground-truth box covers only the chisel, since the hammer is not tracked.
On our limited data set, the composite loss is required to condition the model on audio. Senocak et al. [20] observe that models can score well on sound source localisation without learning the interaction between the audio and visual modalities. In our single-instrument recordings the model can satisfy the contrastive learning objective by responding to the instrument that is present, whichever it is, so the heatmap can be driven by the frame alone. To mitigate this problem, we introduce the composite loss term which introduces a separation between two instruments into the training process. The selection test demonstrates that the model then makes this decision based on the audio.
Limitations. The biggest limitation of the presented work is the limited variation of surgical actions and scenarios contained in the training dataset, as it only contains three exemplary actions of orthopedic surgery. However, we believe that our promising results are a great indicator for the potential of the presented methodology that can motivate the CAS community to consider audio-visual correspondence learning for general surgical scene understanding. Though the acoustic camera corpus contains variation in instrument poses, it lacks variety in camera perspectives, being recorded from a single viewpoint. The validation sequences and the two-tool split, which cover a range of perspectives, indicate that the model is not limited to a specific view. The study covers three instruments, simulated actions on bone models, and a single operating room, and the recordings contain no other sounds of the operating room, such as speech or the beeps of monitoring devices, so robustness to them is untested. The extension beyond an orthopedic use case needs to be investigated in future work, where quieter sounds, such as coagulation or suction in open visceral surgery, need to be tested.
Three properties of the method can be listed as limitations of the current approach. The resolution of the output is coarse in space and time, since the heatmap has cells and localises a region rather than the shape of the instrument, and each prediction is based on 3s of audio. The composite term relies on frames in which the active instrument is known to lie in the central half of the image.
A few failure cases remain. In some frames empty hands also cause a response in the heatmap (Fig. 2), which should be addressed in future work. Also, the case of an instrument that is audible but not visible is not addressed. Furthermore, the current implementation of the model assumes that the sounding instrument is in view and does not handle visual occlusions.
6 Conclusion
We present the first proof-of-concept study of sounding object detection based on audio-visual correspondence in the surgical domain. Our method localises and disambiguates tools reliably, is trained on data recorded with commodity hardware without localisation supervision, and enables the detection and localisation of surgical activity for advanced multimodal surgical scene understanding.
References
[1] Mezger, U., Jendrewski, C., Bartels, M.: Navigation in surgery. Langenbeck's Archives of Surgery 398(4), 501–514 (2013) https://doi.org/10.1007/s00423-013-1059-4
[2] Maier-Hein, L., Vedula, S.S., Speidel, S., Navab, N., Kikinis, R., Park, A., Eisenmann, M., Feussner, H., Forestier, G., Giannarou, S., Hashizume, M., Katic, D., Kenngott, H., Kranzfelder, M., Malpani, A., März, K., Neumuth, T., Padoy, N., Pugh, C., Schoch, N., Stoyanov, D., Taylor, R., Wagner, M., Hager, G.D., Jannin, P.: Surgical data science for next-generation interventions. Nature Biomedical Engineering 1, 691–696 (2017)
[3] Twinanda, A.P., Shehata, S., Mutter, D., Marescaux, J., Mathelin, M., Padoy, N.: Endonet: A deep architecture for recognition tasks on laparoscopic videos. IEEE Transactions on Medical Imaging 36(1), 86–97 (2017)
[4] Özsoy, E., Örnek, E.P., Eck, U., Czempiel, T., Tombari, F., Navab, N.: 4d-or: Semantic scene graphs for or domain modeling. In: Wang, L., Dou, Q., Fletcher, P.T., Speidel, S., Li, S. (eds.) Medical Image Computing and Computer Assisted Intervention – MICCAI 2022, pp. 475–485 (2022)
[5] Ding, H., Seenivasan, L., Killeen, B.D., Cho, S.M., Unberath, M.: Digital twins as a unifying framework for surgical data science: the enabling role of geometric scene understanding. Artificial Intelligence Surgery 4(3) (2024)
[6] Illanes, A., Boese, A., Maldonado, I., Pashazadeh, A., Schaufler, A., Navab, N., Friebe, M.: Novel clinical device tracking and tissue event characterization using proximally placed audio signal acquisition and processing. Scientific Reports 8 (2018)
[7] Seibold, M., Maurer, S., Hoch, A., Zingg, P., Farshad, M., Navab, N., Fürnstahl, P.: Real-time acoustic sensing and artificial intelligence for error prevention in orthopedic surgery. Scientific Reports 11 (2021)
[8] Seibold, M., Hoch, A., Suter, D., Farshad, M., Zingg, P.O., Navab, N., Fürnstahl, P.: Acoustic-based spatio-temporal learning for press-fit evaluation of femoral stem implants. In: International Conference on Medical Image Computing and Computer-Assisted Intervention, pp. 447–456 (2021)
[9] Fuchtmann, J., Riedel, T., Berlet, M., Jell, A., Wegener, L., Wagner, L., Graf, S., Wilhelm, D., Ostler-Mildner, D.: Audio-based event detection in the operating room. International Journal of Computer Assisted Radiology and Surgery 19(12), 2381–2387 (2024)
[10] Seibold, M., Bahari Malayeri, A., Fuernstahl, P.: Spatial context awareness in surgery through sound source localization. In: International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI) (2024)
[11] Hein, J., Vlachopoulos, L., Olthof, M.G.L., Sigrist, B., Fürnstahl, P., Seibold, M.: Sound source localization for spatial mapping of surgical actions in dynamic scenes. International Journal of Computer Assisted Radiology and Surgery, 1–9 (2026)
[12] Chen, H., Xie, W., Afouras, T., Nagrani, A., Vedaldi, A., Zisserman, A.: Localizing visual sounds the hard way. In: 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pp. 16862–16871 (2021). IEEE
[13] Mo, S., Morgado, P.: A closer look at weakly-supervised audio-visual source localization. Advances in Neural Information Processing Systems 35, 37524–37536 (2022)
[14] Park, S., Senocak, A., Chung, J.S.: Hearing and seeing through clip: A framework for self-supervised sound source localization. International Journal of Computer Vision 134(4), 179 (2026)
[15] Juanola, X., Morais, G., Fuentes, M., Haro, G.: Learning from silence and noise for visual sound source localization. arXiv preprint arXiv:2508.21761 (2025)
[16] Park, S., Kim, J.U.: Generate, analyze, and refine: Training-free sound source localization via mllm meta-reasoning. In: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pp. 15752–15761 (2026)
[17] Oquab, M., Darcet, T., Moutakanni, T., Vo, H., Szafraniec, M., Khalidov, V., Fernandez, P., Haziza, D., Massa, F., El-Nouby, A., Assran, M., Ballas, N., Galuba, W., Howes, R., Huang, P.-Y., Li, S.-W., Misra, I., Rabbat, M., Sharma, V., Synnaeve, G., Xu, H., Jégou, H., Mairal, J., Labatut, P., Joulin, A., Bojanowski, P.: DINOv2: Learning robust visual features without supervision. Transactions on Machine Learning Research (2024)
[18] Darcet, T., Oquab, M., Mairal, J., Bojanowski, P.: Vision transformers need registers. In: International Conference on Learning Representations, vol. 2024, pp. 2632–2652 (2024)
[19] Park, S., Senocak, A., Chung, J.S.: Can clip help sound source localization? In: 2024 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV), pp. 5699–5708 (2024). IEEE
[20] Senocak, A., Ryu, H., Kim, J., Oh, T.-H., Pfister, H., Chung, J.S.: Sound Source Localization is All about Cross-Modal Alignment (2023). https://arxiv.org/abs/2309.10724