arXiv:2610.32915cs.HCOct 2026

Manuscript Offprint

arXiv:2610.32915

What Mean Error Misses: Device-Clock Diagnostics for Evaluating Eye Tracking across Three Virtual Reality Headsets

Aleksandr Chernysh, Mehedi Hasan Raju, Kamrul Hasan, Md Arif Shahriar, Proloy Karmakar, Isayas B. Adhanom, Oleg Komogortsev

A PREPRINT

Aleksandr Chernysh

Texas State University

San Marcos, TX, USA

wll146@txstate.edu

Mehedi Hasan Raju

Texas State University

San Marcos, TX, USA

m.raju@txstate.edu

Md Arif Shahriar

Texas State University

San Marcos, TX, USA

arif.shahriar@txstate.edu

Kamrul Hasan

Texas State University

San Marcos, TX, USA

kamrul.hasan@txstate.edu

Proloy Karmakar

Texas State University

San Marcos, TX, USA

proloy@txstate.edu

Isayas B. Adhanom

Texas State University

San Marcos, TX, USA

isayas@txstate.edu

Oleg Komogortsev

Texas State University

San Marcos, TX, USA

ok@txstate.edu

October 2026

ABSTRACT

Gaze research in virtual reality needs eye trackers of known error. Thirty participants completed the same protocol on the Meta Quest Pro (QP), HTC VIVE Pro Eye (PE) and HTC VIVE Focus Vision (FV); to our knowledge, this is the first evaluation of the FV eye tracker. In a random-saccade task, median participant mean error was 1.04° on QP, 1.50° on PE and 2.41° on FV, which remained least accurate after linear recalibration. In a later block with a darker background, PE error rose by 0.70°. FV samples were positively correlated: dispersion was 9.8 times the sample-to-sample root mean square. The device clocks showed losses that mean error hides. QP paused for up to 6.04 s, and FV skipped single samples. During instructed eye closures, QP flagged every sample valid while gaze moved 9.74°. Evaluations should report repeated timestamps, loss composition on the device clock and validity during eye closures.

Keywords eye tracking · signal quality · virtual reality · Meta Quest Pro · HTC VIVE Focus Vision · HTC VIVE Pro Eye · spatial accuracy · precision · data loss

1 Introduction

Eye trackers are now built into several consumer virtual reality (VR) headsets. Gaze is used for interaction (Raju et al., 2025), foveated rendering, social avatars and research on attention and visual behavior (Adhanom et al., 2023). The quality of the gaze signal limits these uses: a gaze-selection target has to be larger than the gaze error of most users (Feit et al., 2017). Manufacturers' accuracy specifications are not always reached in practice (Holmqvist et al., 2012; Lohr et al., 2019), so the signal has to be measured.

Evaluations of single headsets exist for an SMI-equipped HTC Vive (Lohr et al., 2019), the HTC VIVE Pro Eye (PE) (Schuetz and Fiehler, 2022; Sipatchin et al., 2021), the Meta Quest Pro (QP) (Aziz et al., 2024b; Wei et al., 2023) and the HoloLens 2 (Aziz and Komogortsev, 2022). They differ in protocol, processing and participants. Direct comparisons

A PREPRINT

cover four headsets with five participants (Hou et al., 2024) or the Quest Pro against the add-on eye tracker of the VIVE Focus 3 (Rocchi et al., 2025). We found no published evaluation of the eye tracker integrated in the HTC VIVE Focus Vision (FV) (HTC Corporation, 2026a); the search is described in Suppl. S1.

Published values also age with the software. On hardware equivalent to the Quest Pro, Lohr et al. (2026) compared two generations of a Meta gaze-estimation pipeline that estimates gaze from eye images at 72 Hz. The newer pipeline reached 0.79° accuracy and 0.20° sample-to-sample RMS, against 1.07° and 0.32° for the older one (median of participant medians). Quest Pro values measured earlier with the same protocol (Aziz et al., 2024b) may therefore not describe the headset today. The Pro Eye, whose eye tracking is powered by Tobii (HTC Corporation, 2026b), is a frequent laboratory headset (Schuetz and Fiehler, 2022; Sipatchin et al., 2021; Stein et al., 2021) and gives a second reference.

Accuracy and precision summaries also assume that every recorded row is a new measurement of the eye and that the validity flag follows the state of the eye. A mean error cannot test either assumption; the device clock of each tracker can. We ask three research questions:

RQ1 How do accuracy and precision of the QP, FV and PE compare when the same participants complete the same protocol, and how does error change across the field of view?

RQ2 What do the device clocks show about data availability and about repeated, missing and invalid samples, including samples recorded while the eyes are closed?

RQ3 How does accuracy change in a second random-saccade block, which had a darker background and came later in the session, and with raised eyebrows?

Our contributions are:

C1 A paired comparison of three headsets with 30 participants, the same protocol and the same analysis. It includes the first evaluation of the FV eye tracker that we could find and covers accuracy across the field of view and precision (Sections 4.1–4.3 and 4.5).

C2 Diagnostics of each stream on its device clock. Each headset’s clock exposes a different kind of loss that the mean error hides: stale QP rows followed by rows with timestamp zero, QP interruptions longer than 0.1 s, FV gaps of one skipped pupil sample, and QP samples flagged valid during instructed eye closures (Sections 4.6 and 4.7). From these results we propose three checks for evaluations of headset eye trackers (Section 5).