Manuscript Offprint
arXiv:2610.30313SciFusion: Physics-Guided Compositional Diffusion for Multimodal 3D Scientific Image Generation
Abstract
Existing 3D generative approaches are typically developed for individual imaging modalities, requiring substantial modality-specific data and limiting their ability to exploit shared structure across scientific imaging domains. We present SciFusion, a multimodal framework for unified 3D scientific image generation built on a latent diffusion backbone, with two key contributions. First, we introduce a compositional conditioning scheme that factorizes each modality into domain, object, and contrast representations. Sharing these factors across related modalities enables knowledge transfer across heterogeneous imaging domains and allows the factors to be recombined at inference time to synthesize unseen domain–object–contrast compositions in a zero-shot manner. Second, we incorporate domain-specific physics-informed objectives—Fourier spectral consistency for MRI, Radon projection consistency for CT, and multislice diffraction consistency for electron microscopy—to encourage generated samples to respect modality-dependent image formation processes. Extensive experiments across 15 medical and scientific imaging modalities demonstrate that SciFusion improves generation fidelity and cross-domain generalization over modality-specific and flattened multimodal conditioning strategies, while enabling zero-shot synthesis of unseen compositions without training on those target compositions. These results demonstrate that compositional, physics-guided conditioning provides a scalable framework for unified 3D scientific image generation, particularly for emerging modalities where large-scale training data are difficult to obtain. Project page: https://ixoul.github.io/SciFusion-Demo/
1. Introduction
Three-dimensional scientific imaging plays a critical role in biomedical research and scientific discovery, covering diverse modalities such as magnetic resonance imaging (MRI), computed tomography (CT), and electron microscopy (EM). However, collecting large-scale 3D imaging datasets remains challenging due to expensive acquisition procedures, specialized imaging equipment, and privacy constraints in medical applications. These limitations result in fragmented datasets across different imaging domains, restricting the development of data-driven approaches.
Generative models provide a promising solution by learning complex data distributions and synthesizing realistic samples to alleviate data scarcity, support data augmentation, and enable privacy-preserving data sharing [21, 34]. Recent diffusion models have achieved remarkable success in image generation by learning to reverse a gradual noising process [15, 31]. Latent diffusion further reduces the computational and memory requirements of 3D generation by operating in a compressed latent space [5, 28], enabling more efficient synthesis of complex 3D data. Despite these advances, most existing 3D generative models are designed for individual datasets, objects, or imaging modalities. Such modality-specific models require separate training processes and large amounts of dedicated data, limiting knowledge transfer across related imaging domains. Scientific imaging, however, is inherently heterogeneous: MRI modalities differ in anatomical targets and tissue contrasts [6], CT captures different structures through X-ray attenuation, and EM reveals microscopic structures with distinct frequency characteristics. A unified generative model for heterogeneous scientific imaging therefore needs to learn shared representations across modalities while preserving domain-specific imaging properties.
A key challenge toward such a unified model is how to effectively represent and combine heterogeneous imag-
These authors contributed equally as senior authors.
ing information. Treating each modality as an independent class limits generalization to unseen conditions, while directly merging all modalities may introduce ambiguous conditioning and weaken modality-specific characteristics. A more expressive representation should capture the underlying factors that define an imaging modality and allow these factors to be recombined for flexible generation.
In this work, we present SciFusion, a multimodal 3D scientific image generation framework built upon a latent diffusion backbone that combines physics-guided objectives with compositional conditioning across MRI, CT, and EM modalities. Our contributions can be summarized as follows:
• We develop a unified framework that learns a shared latent representation using a vector-quantized autoencoder and performs volumetric generation with a conditional latent diffusion model.
• We introduce a compositional conditioning scheme that factorizes modality information into domain, object, and contrast embeddings, enabling zero-shot generation of unseen domain, object, and contrast combinations without additional modality-specific training data.
• We design domain-specific physical guidance, including power-spectrum consistency for MRI, Radon-domain constraints for CT, and diffraction-pattern constraints for EM, to preserve imaging characteristics.
• We conduct comprehensive evaluations across observed and unseen modality combinations, demonstrating transferable generation and improved consistency with domain-specific physical properties.
2.1. 3D Volumetric Image Generation
Diffusion models have recently enabled high-quality synthesis of three-dimensional medical and scientific images. Medical diffusion performs volumetric generation directly in image space and demonstrates applications to MRI and CT synthesis [21]. To improve scalability, recent methods introduce latent representations for efficient volumetric generation. 3D MedDiffusion and MedLoRD employ pretrained autoencoders to support latent diffusion of 3D medical volumes [29, 37]. MAISI enables high-resolution CT generation with flexible compression and anatomical conditioning [12]. MAISI-v2 further improves sampling efficiency and conditioning accuracy using rectified flow and contrastive learning [40]. Despite these advances, existing methods mainly target specific medical domains or predefined modality conditions, limiting their ability to learn transferable representations across heterogeneous scientific imaging modalities.
2.2. Physics-Guided Generative Models
A complementary line of work incorporates physical priors to improve the fidelity and physical plausibility of generated scientific images, benefiting tasks such as reconstruction and cross-modality generation [2, 7, 32]. For multimodal MRI synthesis, a physics-informed latent diffusion framework first generates latent tissue property maps and subsequently applies a physical signal model to synthesize different MRI contrasts, including unseen modalities [26], demonstrating the potential of combining generative models with acquisition physics for cross-modality synthesis. Beyond medical imaging, physics-guided diffusion priors have also been incorporated for multi-slice reconstruction in scientific imaging, showing the benefit of physical constraints for recovering structurally consistent images [36]. However, these physics-guided generative approaches are primarily developed within individual imaging domains, where physical constraints are closely coupled with a specific acquisition process. Extending physics-guided generation to heterogeneous scientific imaging remains challenging, as different modalities follow distinct physical formation mechanisms, motivating a unified framework that combines transferable multimodal representations with domain-specific physical guidance.
3. Method
SciFusion builds upon the latent diffusion framework [28] and the MedLoRD architecture [29] for efficient high-resolution 3D medical image synthesis (Fig. 1). Training proceeds in two stages: a VQGAN is first pretrained on the integrated multi-modal dataset without modality conditioning to learn a shared latent representation across heterogeneous imaging domains (Sec. 3.1); a conditional 3D latent diffusion model is then trained on the frozen VQGAN latents, with modality information injected through compositional conditioning (Sec. 3.2) and domain-specific physical guidance (Sec. 3.3). At inference, the learned compositional representation supports both seen-composition and zero-shot generation of unseen domain-object-contrast combinations. Detailed training configurations and exact latent dimensions are provided in Sec. B of the supplementary material.
3.1. Latent Diffusion Framework
Each volumetric sample is represented as , where the dimensions correspond to the channel, depth, height, and width, respectively. The pretrained, frozen VQGAN serves as the first-stage compression model: its encoder maps the input volume to a lower-dimensional latent representation, , where and . Only the spatial dimensions are compressed, while the depth dimension is preserved to retain volu-a) Training
b) Inference

Figure 1. Overview of SciFusion. (a) Two-stage training with shared latent representation learning, compositional conditioning, and domain-specific physics guidance. (b) Inference via recombination of learned conditioning components, enabling both seen-modality generation and zero-shot synthesis of unseen modality combinations.
metric continuity across slices. The corresponding decoder reconstructs the volumetric image as . During diffusion training, a timestep is randomly sampled, and Gaussian noise is added to the clean latent representation according to a noise schedule:
where and control the contributions of the clean latent signal and Gaussian noise at timestep t. Following the v-prediction formulation, the corresponding training target is
A conditional 3D U-Net predicts the velocity target from the noisy latent representation, diffusion timestep, and conditioning representation:
where denotes the compositional conditioning embedding introduced in the following subsection. The latent diffusion objective is then defined as
Unlike the original single-domain formulation of Med-LoRD, our framework employs a shared diffusion backbone to jointly model heterogeneous imaging modalities, while modality-specific generation is controlled through the proposed compositional conditioning mechanism.
3.2. Compositional Conditioning Mechanism
A conventional multimodal diffusion model typically assigns an independent learnable embedding to each imaging modality. Although this flattened conditioning strategy can distinguish modalities observed during training [37], it treats each modality as an unrelated category, without exploiting shared structure across heterogeneous scientific images. To address this limitation, we represent each modality as a composition of three semantic factors: imaging domain, anatomical or structural object, and imaging contrast. Specifically, the condition of a volumetric sample is represented as , where , , and denote the imaging domain, target object, and acquisition contrast, respectively. We introduce three independent learnable embedding tables , , , yielding embeddings for , where is the conditioning dimension. The final conditioning representation is obtained through element-wise addition:
The resulting vector is treated as a single conditioning token, , and is injected into the conditional 3D U-Net through its cross-attention layers. For a batch of volumetric samples, the complete conditioning tensor has the shape . Compared with a flattened modality embedding, this factorized representation allows related modalities to share parameters at multiple semantic levels. Modalities from the same imaging domain reuse the domain embedding, while modalities de-picting the same object or using the same contrast share the corresponding object or contrast embedding. This encourages the model to learn both modality-specific characteristics and common structures across heterogeneous imaging modalities. Additionally, it allows unseen modality combinations to be constructed directly from factors observed during training, without introducing an additional modality-specific embedding. This property provides the basis for the compositional zero-shot generation evaluated in our experiments.
3.3. Physics-Informed Training Objective
While the latent denoising objective encourages accurate recovery of the clean latent representation, it does not explicitly enforce the physical acquisition constraints of different imaging domains. Given the predicted noise, we first recover the clean latent estimate and decode it into a predicted volume . For each sample, a domain-dependent differentiable operator is applied to both the reference and predicted volumes, with logarithmic scaling applied to reduce their dynamic range:
where denotes the imaging domain of the -th sample, with instantiated as one of , , or , as described below. This formulation allows different physical or spectral constraints to be applied within the same mixed-domain training batch.
Magnetic Resonance Imaging (MRI). For MRI, since raw data is acquired in k-space, we constrain the slice-wise spatial-frequency distribution using a logarithmic Fourier power-spectrum representation:
This spectral loss aligns the frequency content of generated and reference MRI volumes.
Computed Tomography (CT). For CT, we impose consistency in the tomographic projection domain using a differentiable Radon transform over multiple projection angles to obtain a sinogram representation [14, 38]:
where R denotes the differentiable Radon transform. This loss enforces consistency between the projection measurements of generated and reference CT volumes.
Electron Microscopy (EM). For EM, we apply a diffraction-inspired differentiable multislice operator [8–10, 19, 22] using plane wave illumination , which is sequentially modulated by the slices and propagated using a Fresnel kernel. The wave function after the n-th slice is computed as
Here, denotes the -th slice of volumetric data (i.e., the projected electrostatic potential), and and denote the two-dimensional Fourier and inverse Fourier transforms, respectively, while denotes the Fresnel propagation kernel. After propagation through all slices, the diffraction representation is computed from the far-field intensity as
This loss aligns the far-field diffraction patterns of generated and reference EM volumes. The overall training objective is
Here, controls the strength of the domain-specific regularization; this supervision is applied only during training and does not alter the inference procedure. The selection of is analyzed via an ablation over regularization strength in Section 4.4.
4. Results
4.1. Benchmark Overview
We construct a volumetric imaging benchmark comprising 15 modalities from three domains: magnetic resonance imaging (MRI), computed tomography (CT), and electron microscopy (EM). The modalities span multiple anatomical structures and imaging contrasts, allowing us to evaluate both unified multimodal generation and compositional generalization across diverse scientific images. EM serves as out-of-distribution data relative to the medical imaging domains, enabling us to assess the framework's robustness and generalizability across fundamentally different imaging modalities. The physical parameters of all datasets are provided in the supplementary material (Sec. A).
Evaluation Metrics. As each generated sample is a multi-slice volume, we treat the slice dimension analogously to the temporal dimension in video and adopt video-based distributional metrics accordingly, following prior work that applies such metrics to volumetric medical imaging [13]. We evaluate generation quality against real data using FVD, KID, and JEDI [4, 25, 35]. Specifically, Fréchet Video Distance (FVD) and Kernel Inception Distance (KID) measure the distributional discrepancy between
Table 1. Generalization of compositional conditioning across different diffusion architectures. Each backbone is evaluated using its original conditioning strategy and the proposed compositional conditioning. All results are macro-averaged over the 15 imaging modalities.
| Backbone | Conditioning | VMAE | I3D | JEDI | ||
|---|---|---|---|---|---|---|
| FVD | KID | FVD | KID | |||
| Backbone-specific baseline | ||||||
| MedLoRD [29] | Flattened | 28.63 | 106.80 | 11.80 | 21.08 | 2.356 |
| Video Diffusion [16] | Original | 56.87 | 184.97 | 24.00 | 49.28 | 4.63 |
| 3DMedDiff [37] | Original | 91.27 | 373.75 | 33.40 | 78.48 | 8.341 |
| Medical Diffusion [21] | Original | 34.55 | 130.12 | 13.19 | 24.08 | |
| Compositional conditioning | ||||||
| MedLoRD [29] | Compositional | |||||
| Video Diffusion [16] | Compositional | |||||
| 3DMedDiff [37] | Compositional | |||||
| Medical Diffusion [21] | Compositional | |||||
| SciFusion (Ours) | Compositional | |||||
Note: Underline values indicate the better result between baseline and compositional conditioning for the same backbone.
generated and real volumes in a pretrained feature space, with lower values indicating closer alignment to the real data distribution. Since feature extractors trained on natural video may not fully capture volumetric medical/scientific structures, we compute FVD and KID using two complementary backbones – VideoMAE (VMAE) and I3D – denoted as VMAE-FVD/KID and I3D-FVD/KID, respectively. JEDI [25] further provides a joint embedding distance based on a Joint Embedding Predictive Architecture (JEPA), using Maximum Mean Discrepancy instead of the Gaussian assumption underlying FVD/KID; this improves robustness under limited sample sizes, which is particularly relevant given the number of real samples available for some modalities.
4.2. Comparison Across Conditioning Strategies
Training Data. For MRI, knee PD, knee PD fat-suppressed, brain T1, brain T2, brain FLAIR, prostate diffusion-weighted, prostate T2-weighted, and breast MRI volumes are obtained from the NYU fastMRI Initiative database [23, 39]. For CT, head CT volumes are derived from the RSNA 2019 Brain CT Hemorrhage Challenge dataset [11], while chest and abdominal CT volumes are obtained by merging the corresponding subsets of the Medical Segmentation Decathlon [30]. CT data are preprocessed into fixed-depth volumetric samples following the same spatial normalization pipeline used for MRI. The EM domain contains four structural modalities, including cubic and hexagonal crystal structures, apoferritin, and hemoglobin, obtained from the Materials Project [20] and the Protein Data Bank (PDB) [1], and processed into volumetric stacks with the same number of slices and spatial resolution as the medical imaging data using abTEM [27]. For evaluation, we generate 400 samples per modality and compare the generated distribution against all available real samples of the corresponding modality.
Backbones and Baselines. Existing approaches typically adopt backbone-specific conditioning mechanisms, where modality information is represented using model-dependent formulations. We investigate whether explicitly factorizing modality information into domain, anatomical object, and imaging contrast components provides a more effective conditioning strategy for multimodal 3D scientific image generation. We evaluate whether compositional conditioning generalizes across diffusion backbones by comparing four representative architectures: MedLoRD [29], Video Diffusion [16], 3DMedDiff [37], and Medical Diffusion [21]. For MedLoRD, the baseline uses a flattened modality embedding, where each modality is assigned an independent learnable representation. For the remaining backbones, we retain their original conditioning mechanisms as baselines and replace them with the proposed compositional conditioning strategy while keeping all other model components unchanged.
As shown in Table 1, compositional conditioning consistently improves generation quality across different diffusion backbones. The proposed representation reduces both VideoMAE-FVD and I3D-FVD for all evaluated architectures, demonstrating improved perceptual fidelity and structural consistency of generated 3D volumes. The improvement is particularly significant for 3DMedDiff, where
Slice Index
Head CT Chest CT Apof. EM Cubic EM Breast T1 Prostate T2 Brain T2 Knee PD

Figure 2. Selected generated 3D volumes across all selected modalities.
compositional conditioning reduces VideoMAE-FVD from 91.27 to 26.85 and I3D-FVD from 33.40 to 11.01.
These results demonstrate that domain–object–contrast factorization provides a generalizable conditioning strategy for multimodal 3D scientific image generation. While Table 1 reports results macro-averaged across all 15 modalities, a per-domain (MRI/CT/EM) breakdown is provided in the supplementary material (Table 8).
Notably, SciFusion achieves the best performance across all evaluated metrics, obtaining the lowest VMAE-FVD, VMAE-KID, I3D-FVD, I3D-KID, and JEDI scores among all compared methods. To complement these quantitative results, we further provide qualitative visualizations of the generated volumes. Specifically, we present representative examples from 8 out of the 15 imaging modalities in Fig. 2 (see Fig. 4 in supplementary materials for all modalities and slices). The selected modalities span different imaging domains, anatomical structures, and acquisition contrasts, further demonstrating the capability of our unified model to generate diverse 3D scientific images.
4.3. Zero-shot Compositional Generation
Zero-shot Setup. To evaluate compositional zero-shot generation, we consider two unseen modalities whose factor combinations are excluded from training. Knee T1-weighted MRI is obtained from MRNet [3, 33], while brain PD-weighted MRI is obtained from the IXI dataset [18]. Both modalities combine domains, anatomical objects, and contrasts that are individually observed during training but never presented together as complete modality combinations, providing a direct test of whether the proposed compositional conditioning mechanism can recombine learned semantic factors to generate unseen modalities. We generate 600 samples per target modality and compare SciFusion's zero-shot generation against two baselines: fully supervised single-modality diffusion models trained directly on target-modality samples, which represent an upper bound with direct access to the target distribution; and parameter-efficient adaptation (PEFT) using LoRA [17], which adapts a pretrained model from a related observed modality to the target modality (Knee PD → Knee T1, Brain
Table 2. Zero-shot compositional generation on unseen target modalities compared with fully supervised target-modality training and parameter-efficient adaptation.
| Target Modality | Backbone | Supervision | I3D | VMAE | JEDI ↓ | ||
|---|---|---|---|---|---|---|---|
| FVD ↓ | KID (×103) ↓ | FVD ↓ | KID (×103) ↓ | ||||
| Knee T1 | SciFusion (Ours) | Full | 13.83 | 23.13 ± 2.00 | 14.56 | 58.71 ± 3.78 | 0.35 |
| SciFusion (Ours) | Zero-shot | 26.14 | 50.23 ± 2.39 | 58.32 | 252.47 ± 7.07 | 2.88 | |
| Medical Diffusion [21] | Zero-shot | 28.46 | 54.50 ± 2.65 | 72.46 | 322.46 ± 7.36 | 3.59 | |
| VDM + LoRA [16, 17] | PEFT | 15.99 | 23.06 ± 1.39 | 25.63 | 102.29 ± 6.65 | 1.05 | |
| Brain PD | SciFusion (Ours) | Full | 2.90 | 4.30 ± 0.49 | 5.22 | 19.19 ± 1.25 | 0.46 |
| SciFusion (Ours) | Zero-shot | 23.52 | 63.84 ± 3.98 | 15.34 | 64.17 ± 2.36 | 1.68 | |
| Medical Diffusion [21] | Zero-shot | 11.02 | 23.54 ± 1.03 | 27.97 | 125.20 ± 4.35 | 2.25 | |
| VDM + LoRA [16, 17] | PEFT | 14.33 | 30.70 ± 2.00 | 31.13 | 137.24 ± 4.07 | 1.75 | |
T1 → Brain PD) using additional target-modality samples.
During training, the model observes no samples from the target modalities; each target is instead synthesized at inference time by recomposing previously learned domain, object, and contrast representations (e.g., combining a learned knee/brain object with a learned T1/PD contrast), without additional optimization.
As shown in Table 2, fully supervised models achieve the best performance due to direct access to target-modality samples, while the gap on zero-shot targets reflects the inherent difficulty of synthesizing unseen imaging contrasts without target-specific data. Nonetheless, the proposed compositional model generates unseen modalities without observing any target-modality samples or performing additional optimization, indicating that the learned compositional representation captures transferable relationships between anatomical structures and imaging contrasts. PEFT narrows this gap on knee T1 by adapting the pretrained model with target-modality samples and additional optimization; notably, on brain PD our training-free zero-shot generation already matches or exceeds PEFT on JEDI (1.68 vs. 1.75), suggesting that the learned composition for this target is already well aligned without adaptation.
Qualitative comparisons are provided in Fig. 3. The zero-shot generation produces visually plausible anatomical structures and modality-specific appearance without accessing any target-modality samples. These qualitative results suggest the potential of compositional conditioning for synthesizing unseen imaging modalities in a training-free manner.
4.4. Ablation Study
Unified Multimodal Generation. We further perform an ablation study to investigate the contribution of different conditioning strategies and physical guidance proposed in SciFusion. These comparisons disentangle the effects of pa-
(a)

(b)
(c)
Figure 3. Qualitative comparison of generation on unseen target modalities (knee T1 and brain PD). (a) Real target-modality images, (b) our zero-shot generation without access to target-modality data or additional training, and (c) parameter-efficient fine-tuning (PEFT) using VDM with LoRA and target-modality samples.
rameter sharing, semantic decomposition of modality information, and physical priors on multimodal generation. As shown in Table 3, the unified multimodal model achieves comparable or better generation quality while reducing the number of models from 15 to 1. The flattened multimodal model improves all evaluation metrics, demonstrating that joint training across heterogeneous modalities can effectively exploit shared information between domains, compared with training a separate model for each single modality. Introducing compositional conditioning further improves generation quality, reducing I3D-FVD from 11.80 to 11.10 and VideoMAE-FVD from 28.63 to 27.30, indicating that modeling the underlying semantic factors of scientific imaging modalities provides a more effective conditioning representation than treating each modality as an indepen-
Table 3. Ablation study of SciFusion across four configurations: single-modality models, flattened multimodal conditioning, compositional conditioning, and the full model with physics guidance.
| Method | # Models | Comp. | Physics | I3D-FVD ↓ | VMAE-FVD ↓ | JEDI ↓ |
|---|---|---|---|---|---|---|
| Single Modality | 15 | - | - | 13.07 | 35.93 | 2.62 |
| Flat Multimodal | 1 | - | - | 11.80 | 28.63 | 2.36 |
| Comp. Multimodal | 1 | ✓ | - | 11.10 | 27.30 | 2.35 |
| Ours | 1 | ✓ | ✓ | 9.90 | 23.51 | 1.80 |
dent category. Finally, adding physics-guided regularization achieves the best overall performance, with improvements across all evaluation metrics. These results demonstrate that unified multimodal learning, compositional conditioning, and physical constraints provide complementary benefits for scalable 3D scientific imaging.
Physical Loss Weight Sensitivity. We further investigate the sensitivity of the physical-loss weight across three values ( , , ), keeping all other training configurations unchanged and evaluating at approximately the same training stage. Table 4 shows that consistently underperforms across all domains, indicating a minimum regularization strength is needed for the constraints to take effect. For MRI and CT, is uniformly best across all metrics; for EM, gives better FVD/KID but gives substantially better JEDI (1.50 vs. 2.13). Averaged across all three domains, achieves the best overall performance on every metric, so we adopt it as a single default weight across domains, consistent with our shared training configuration.
Table 4. Effect of physical-loss regularization strength across different imaging domains. KID is multiplied by for readability.
| Domain | I3D | VMAE | JEDI ↓ | |||
|---|---|---|---|---|---|---|
| FVD ↓ | KID ↓ | FVD ↓ | KID ↓ | |||
| MRI | 10.18 | 18.04 | 24.70 | 95.35 | 1.46 | |
| 11.59 | 22.26 | 28.69 | 114.18 | 1.64 | ||
| 11.46 | 21.40 | 28.95 | 115.29 | 1.64 | ||
| EM | 5.42 | 6.28 | 16.85 | 46.68 | 1.50 | |
| 5.04 | 5.59 | 15.15 | 38.46 | 2.13 | ||
| 5.87 | 7.51 | 18.06 | 50.54 | 2.44 | ||
| CT | 16.72 | 30.38 | 31.81 | 123.55 | 3.08 | |
| 21.89 | 45.18 | 36.66 | 142.38 | 3.37 | ||
| 17.83 | 33.58 | 34.92 | 136.25 | 3.45 | ||
| Overall | 9.90 | 16.59 | 23.51 | 84.77 | 1.80 | |
| 11.47 | 21.29 | 25.77 | 94.58 | 2.15 | ||
| 10.87 | 19.20 | 26.51 | 97.90 | 2.27 | ||
5. Conclusion
Scientific imaging often faces a practical imbalance in data availability: while some imaging domains and acquisition settings are well represented, newly introduced contrasts, protocols, or imaging configurations may have only limited data. We presented SciFusion, which mitigates this challenge by exploiting shared structure across modalities through compositional conditioning, while domain-specific physics objectives provide additional guidance tailored to different image formation processes.
Across 15 medical and scientific imaging modalities, compositional conditioning and physics guidance together improve generation quality over conventional conditioning strategies, reducing I3D-FVD from 11.80 to 9.90 relative to a flattened multimodal baseline, with both components contributing to the improvement. Beyond improved generation fidelity, factorizing modality information into reusable semantic components allows the model to synthesize previously unseen combinations of known factors without training on the target composition. This setting is particularly relevant when a new imaging configuration shares characteristics with existing modalities—for example, an established anatomical target acquired under a new contrast or protocol. In such cases, knowledge learned from related data can be reused before a large target-specific dataset becomes available, allowing generated samples to serve as an initial data source for method development while a complete target-specific dataset is collected.
Limitations and Future Work The effectiveness of zero-shot compositional transfer depends on the extent to which a target modality can be represented by factors already observed during training. When the target exhibits substantial acquisition-specific or distributional differences, recombining known factors alone may be insufficient to capture its characteristics. A natural extension is therefore to combine compositional transfer with lightweight target-specific guidance or few-shot adaptation when limited real samples are available. Future work will also explore automatically learned compositional representations beyond manually defined categories and evaluate the approach across broader imaging domains, scanners, and acquisition protocols.
References
[1] Ivo M. Baltruschat, Felix Kreis, Alexander Hoelscher, Melanie Dohmen, and Matthias Lenga. freggan with k-space loss regularization for medical image translation. ArXiv, abs/2303.15938, 2023. 5
[2] Arya Bangun, Zhuo Cao, Alessio Quercia, Hanno Scharr, and Elisabeth Pfaehler. Mri reconstruction with regularized 3d diffusion model (r3dm). In 2025 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV), page 700–710. IEEE, 2025. 2
[3] Nicholas Bien, Pranav Rajpurkar, Robyn L. Ball, Jeremy Irvin, Allison Park, Erik Jones, Michael Bereket, Bhavik N. Patel, Kristen W. Yeom, Katie Shpanskaya, Safwan Halabi, Evan Zucker, Gary Fanton, Derek F. Amanatullah, Christopher F. Beaulieu, Geoffrey M. Riley, Robert J. Stewart, Francis G. Blankenberg, David B. Larson, Richard H. Jones, Curtis P. Langlotz, Andrew Y. Ng, and Matthew P. Lungren. Deep-learning-assisted diagnosis for knee magnetic resonance imaging: Development and retrospective validation of mrnet. PLOS Medicine, 15(11):e1002699, 2018. 6, 11
[4] Mikolaj Bińkowski, Danica J Sutherland, Michael Arbel, and Arthur Gretton. Demystifying mmd gans. International Conference on Learning Representations, 2018. 4
[5] Andreas Blattmann, Robin Rombach, Huan Ling, Tim Dockhorn, Seung Wook Kim, Sanja Fidler, and Karsten Kreis. Align your latents: High-resolution video synthesis with latent diffusion models, 2023. 1
[6] Qi Chen, Xiaoxi Chen, Haorui Song, Zhiwei Xiong, Alan L. Yuille, Chen Wei, and Zongwei Zhou. Towards generalizable tumor synthesis. 2024 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 11147–11158, 2024. 1
[7] Hyungjin Chung and Jong Chul Ye. Score-based diffusion models for accelerated mri. Medical image analysis, 80:102479, 2022. 2
[8] JM Cowley and AF Moodie. The scattering of electrons by atoms and crystals. ii. the effects of finite source size. Acta Crystallographica, 12(5):353–359, 1959. 4
[9] John M Cowley and Alexander Forbes Moodie. The scattering of electrons by atoms and crystals. i. a new theoretical approach. Acta Crystallographica, 10(10):609–619, 1957.
[10] JM t Cowley and AF Moodie. The scattering of electrons by atoms and crystals. iii. single-crystal diffraction patterns. Acta Crystallographica, 12(5):360–367, 1959. 4
[11] Adam E. Flanders, Luciano M. Prevedello, George Shih, Safwan S. Halabi, Jayashree Kalpathy-Cramer, Robyn Ball, John T. Mongan, Anouk Stein, Felipe C. Kitamura, Matthew P. Lungren, Gagandeep Choudhary, Lesley Cala, Luiz Coelho, Monique Mogensen, Fanny Morón, Elka Miller, Ichiro Ikuta, Vahe Zohrabian, Olivia McDonnell, Christie Lincoln, Lubdha Shah, David Joyner, Amit Agarwal, Ryan K. Lee, and Jaya and Nath. Construction of a machine learning dataset through collaboration: The rsna 2019 brain ct hemorrhage challenge. Radiology: Artificial Intelligence, 2(3):e190211, 2020. PMID: 33937827. 5, 11
[12] Pengfei Guo, Can Zhao, Dong Yang, Ziyue Xu, Vishwesh Nath, Yucheng Tang, Benjamin Simon, Mason Belue, Stephanie Harmon, Baris Turkbey, and Daguang Xu. Maisi: Medical ai for synthetic imaging. In 2025 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV), pages 4430–4441, 2025. 2
[13] Ibrahim Ethem Hamamci, Sezgin Er, Anjany Sekuboyina, Enis Simsar, Alperen Tezcan, Ayse Gulnihan Simsek, Sevval Nil Esirgun, Furkan Almas, Irem Doğan, Muhammed Furkan Dasdelen, Chinmay Prabhakar, Hadrien Reynaud, Sarthak Pati, Christian Bluethgen, Mehmet Kemal Ozdemir, and Bjoern Menze. Generatect: Text-conditional generation of 3d chest ct volumes. In Computer Vision – ECCV 2024, pages 126–143, Cham, 2025. Springer Nature Switzerland. 4
[14] Ji He, Yongbo Wang, and Jianhua Ma. Radon inversion via deep learning. IEEE Transactions on Medical Imaging, 39(6):2076–2087, 2020. 4
[15] Jonathan Ho, Ajay Jain, and Pieter Abbeel. Denoising diffusion probabilistic models. In Proceedings of the 34th International Conference on Neural Information Processing Systems, Red Hook, NY, USA, 2020. Curran Associates Inc. 1
[16] Jonathan Ho, Tim Salimans, Alexey Gritsenko, William Chan, Mohammad Norouzi, and David J. Fleet. Video diffusion models. In Proceedings of the 36th International Conference on Neural Information Processing Systems, Red Hook, NY, USA, 2022. Curran Associates Inc. 5, 7
[17] Edward J Hu, Yelong Shen, Phillip Wallis, Zeyuan Allen-Zhu, Yuanzhi Li, Shean Wang, Lu Wang, and Weizhu Chen. LoRA: Low-rank adaptation of large language models. In International Conference on Learning Representations, 2022. 6, 7
[18] Information eXtraction from Images Project. IXI Dataset. https://brain-development.org/ixi-dataset/. Licensed under CC BY-SA 3.0; accessed August 4, 2026. 6, 11
[19] KAZUO Ishizuka and NATSU Uyeda. A new theoretical and practical approach to the multislice method. Foundations of Crystallography, 33(5):740–749, 1977. 4
[20] Anubhav Jain, Shyue Ping Ong, Geoffroy Hautier, Wei Chen, William Davidson Richards, Stephen Dacek, Shreyas Cholia, Dan Gunter, David Skinner, Gerbrand Ceder, et al. Commentary: The materials project: A materials genome approach to accelerating materials innovation. APL materials, 1(1), 2013. 5
[21] Firas Khader, Gustav Müller-Franzes, Soroosh Tayebi Arasteh, et al. Denoising diffusion probabilistic models for 3D medical image generation. Scientific Reports, 13(1):7303, 2023. 1, 2, 5, 7
[22] Earl J Kirkland. Advanced computing in electron microscopy. Springer, 1998. 4
[23] Florian Knoll, Jure Zbontar, Anuroop Sriram, Matthew J. Muckley, Mary Bruno, Aaron Defazio, Marc Parente, Krzysztof J. Geras, Joe Katsnelson, Hersh Chandarana, Zizhao Zhang, Michal Drozdzal, Adriana Romero, Michael Rabbat, Pascal Vincent, James Pinkerton, Duo Wang, Nafissa Yakubova, Erich Owens, C. Lawrence Zitnick,
Michael P. Recht, Daniel K. Sodickson, and Yvonne W. Lui. fastMRI: A publicly available raw k-space and DICOM dataset of knee images for accelerated MR image reconstruction using machine learning. Radiology: Artificial Intelligence, 2(1):e190007, 2020. 5
[24] I Lobato and D Van Dyck. An accurate parameterization for scattering factors, electron densities and electrostatic potentials for neutral atoms that obey all physical constraints. Foundations of Crystallography, 70(6):636–649, 2014. 11
[25] Ge Ya Luo, Gian Mario Favero, Zhi Hao Luo, Alexia Jolicoeur-Martineau, and Christopher Pal. Beyond FVD: Enhanced evaluation metrics for video generation quality. ICLR, 2025. 4, 5
[26] Sven Lüpke, Yousef Yeganeh, Ehsan Adeli, Nassir Navab, and Azade Farshad. Physics-informed latent diffusion for multimodal brain mri synthesis. In Medical Image Computing and Computer Assisted Intervention – MICCAI 2024 Workshops: LDTM 2024, MMMI/ML4MHD 2024, ML-CDS 2024, Held in Conjunction with MICCAI 2024, Marrakesh, Morocco, October 6–10, 2024, Proceedings, page 198–207, Berlin, Heidelberg, 2024. Springer-Verlag. 2
[27] Jacob Madsen and Toma Susi. The abtem code: transmission electron microscopy from first principles. Open Research Europe, 1:24, 2021. 5
[28] Robin Rombach, Andreas Blattmann, Dominik Lorenz, Patrick Esser, and Bjorn Ommer. High-Resolution Image Synthesis with Latent Diffusion Models. In 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), pages 10674–10685, Los Alamitos, CA, USA, 2022. IEEE Computer Society. 1, 2
[29] Marvin Seyfarth, Salman Ul Hassan Dar, Isabelle Ayx, Matthias Alexander Fink, Stefan O. Schoenberg, Hans-Ulrich Kauczor, and Sandy Engelhardt. Medlord: A medical low-resource diffusion model for high-resolution 3d ct image synthesis. In Simulation and Synthesis in Medical Imaging, pages 1–12, Cham, 2026. Springer Nature Switzerland. 2, 5
[30] Amber L. Simpson, Michela Antonelli, Spyridon Bakas, Michel Bilello, Keyvan Farahani, Bram van Ginneken, Annette Kopp-Schneider, Bennett A. Landman, Geert Litjens, Bjoern Menze, Olaf Ronneberger, Ronald M. Summers, Patrick Bilic, Patrick F. Christ, Richard K. G. Do, Marc Gollub, Jennifer Golia-Pernicka, Stephan H. Heckers, William R. Jarnagin, Maureen K. McHugo, Sandy Napel, Eugene Vorontsov, Lena Maier-Hein, and M. Jorge Cardoso. A large annotated medical image dataset for the development and evaluation of segmentation algorithms, 2019. 5, 11
[31] Yang Song, Jascha Sohl-Dickstein, Diederik P Kingma, Abhishek Kumar, Stefano Ermon, and Ben Poole. Score-based generative modeling through stochastic differential equations. arXiv preprint arXiv:2011.13456, 2020. 1
[32] Yang Song, Jascha Sohl-Dickstein, Diederik P Kingma, Abhishek Kumar, Stefano Ermon, and Ben Poole. Score-based generative modeling through stochastic differential equations. In International Conference on Learning Representations, 2021. 2
[33] Stanford Center for Artificial Intelligence in Medicine and Imaging. MRNet: Knee MRIs. https://doi.org/10.71718/rcbp-8c35. Accessed: 2026-08-04. 6, 11
[34] Petru-Daniel Tudosiu, Walter Hugo Lopez Pinaya, Pedro Ferreira Da Costa, et al. Realistic morphology-preserving generative modelling of the brain. Nature Machine Intelligence, 6:811–819, 2024. 1
[35] Thomas Unterthiner, Sjoerd van Steenkiste, Karol Kurach, Raphaël Marinier, Marcin Michalski, and Sylvain Gelly. FVD: A new metric for video generation. ICLR Workshop DeepGenStruct, 2019. 4
[36] Laurentius Valdy, Richard D Paul, Alessio Quercia, Zhuo Cao, Xuan Zhao, Hanno Scharr, and Arya Bangun. Physics-guided diffusion priors for multi-slice reconstruction in scientific imaging. In ICASSP 2026-2026 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), pages 6271–6275. IEEE, 2026. 2
[37] Haoshen Wang, Zhentao Liu, Kaicong Sun, Xiaodong Wang, Dinggang Shen, and Zhiming Cui. 3d meddiffusion: A 3d medical latent diffusion model for controllable and high-quality medical image generation. IEEE Transactions on Medical Imaging, 44:4960–4972, 2024. 2, 3, 5
[38] Shuo Xu, Jintao Fu, Yuewen Sun, Peng Cong, and Xincheng Xiang. Deep radon prior: A fully unsupervised framework for sparse-view ct reconstruction. Comput. Biol. Med., 189(C), 2025. 4
[39] Jure Zbontar, Florian Knoll, Anuroop Sriram, Tullie Murrell, Zhengnan Huang, Matthew J. Muckley, Aaron Defazio, Ruben Stern, Patricia Johnson, Mary Bruno, Marc Parente, Krzysztof J. Geras, Joe Katsnelson, Hersh Chandarana, Zizhao Zhang, Michal Drozdzal, Adriana Romero, Michael Rabbat, Pascal Vincent, Nafissa Yakubova, James Pinkerton, Duo Wang, Erich Owens, C. Lawrence Zitnick, Michael P. Recht, Daniel K. Sodickson, and Yvonne W. Lui. fastMRI: An open dataset and benchmarks for accelerated MRI. arXiv preprint arXiv:1811.08839, 2018. 5, 11
[40] Can Zhao, Pengfei Guo, Dong Yang, Yufan He, Yucheng Tang, Benjamin Simon, Mason Belue, Stephanie Harmon, Baris Turkbey, and Daguang Xu. Maisi-v2: Accelerated 3d high-resolution medical image synthesis with rectified flow and region-specific contrastive loss. Proceedings of the AAAI Conference on Artificial Intelligence, 40(15):13088–13098, 2026. 2
Supplementary Materials
A. Dataset and Preprocessing Details
Magnetic Resonance Imaging (MRI). We collect volumetric data from fastMRI dataset [39], Brain IXI [18], Stanford Knee [3, 33]. The datasets are acquired with the field strength of 1.5 T and 3 T. All data are pre-processed to have depth, height, and width dimension . The slice dimension is chosen such that we have important feature. The Brain IXI and Stanford Knee data are used only to assess the zero shot generation using compositional embedding, hence, we do not use the data for training the model. The summary is given in Table 5.
Table 5. Summary of MRI datasets
| Dataset | Anatomy | Contrast | Total |
|---|---|---|---|
| fastMRI | Knee | PD and PDFS | (480, 486) |
| fastMRI | Brain | T1,T2, and FLAIR | (328, 1367, 2547) |
| fastMRI | Prostate | T2 and DWI | (272, 261) |
| fastMRI | Breast | T1 | 609 |
| IXI | Brain | PD | 566 |
| MRNet | Knee | T1 | 1130 |
Computed Tomography (CT). We collect CT data from RSNA Brain data [11] and Medical Segmentation Decathlon [30]. The images are pre-processed such that we have with the number of slices 16. The summary is given in Table 6.
Table 6. Summary of the CT datasets
| Dataset | Anatomy | Total |
|---|---|---|
| RSNA | Brain | 339 exams (subset) |
| MSD | Liver | 201 scans |
| MSD | Lung | 96 scans |
| MSD | Pancreas | 420 scans |
| MSD | Colon | 190 scans |
| MSD | Liver | 443 scans |
| MSD | Spleen | 61 scans |
Electron Microscopy (EM). Table 7 summarizes the abTEM simulation parameters for both crystalline and protein datasets, including cell size, spatial resolution, slice discretization, and propagation settings. In both cases, simulations are performed using plane-wave illumination. For crystal materials we construct cubic and hexagonal structure with total volumetric data 278 and 160, respectively.
Additionally for protein we collect 69 apoferritin and 204 hemoglobin data.
Table 7. abTEM simulation parameters used for dataset generation.
| Parameter | Crystal data | Protein data |
|---|---|---|
| Pixel Dimension | ||
| Sampling / pixel size | ||
| Number of slices (S) | 16 | 16 |
| Slice thickness | ||
| Potential | Lobato [24] | Lobato[24] |
| Incident wave | Plane wave | Plane wave |
| Electron energy | 300 keV | 300 keV |
B. Model Architecture Details
Computing Resources. In our experiments, we leveraged high-performance computing (HPC) nodes equipped with 8 NVIDIA A100 GPUs with 80GB VRAM each and 128 CPU cores.
VQGAN Training Details. We employ a 3D VQGAN as the first-stage autoencoder to learn a compact latent representation for high-resolution scientific imaging volumes. The VQGAN is trained on the complete multi-modal dataset, including all available imaging domains and modalities, to learn a shared latent space across heterogeneous scientific images. Importantly, the VQGAN training does not use any modality-specific supervision or target-modality adaptation.
The input volume size is . The encoder compresses each volume into a latent representation with 8 channels and a spatial resolution of , which is subsequently used by the latent diffusion model. The vector quantization module contains a codebook of 16,384 embeddings with an embedding dimension of 8. The commitment cost is set to 0.25.
The VQGAN is trained for 1,000 epochs with a batch size of 1. We use Adam optimization with learning rates of and for the generator and discriminator, respectively. The training objective combines reconstruction, perceptual, adversarial, and 3D feature-based Jukebox losses. The perceptual, adversarial, and Jukebox loss weights are set to 0.1, 0.008, and 0.7, respectively. Adversarial training is introduced after a 10-epoch warm-up period. The discriminator is a 3D convolutional network with 64 channels and two layers, using instance normalization. The VQGAN architecture uses three encoder-decoder stages with channel dimensions of [128, 256, 512] and two residual layers per stage. All activation functions are ReLU.
Latent Diffusion Training Details. We train a latent diffusion model on the compact latent space learned by the pretrained VQGAN. The diffusion model operates on latent representations with 8 channels and a volumetric resolution of . All experiments use precomputed latent representations extracted from the VQGAN encoder rather than directly training the diffusion model in the image space. The latent diffusion model is implemented using a 3D U-Net architecture with channel dimensions of [64, 128, 256, 512] and two residual blocks at each resolution level. Attention modules are applied at the two highest-resolution stages. Cross-attention conditioning is enabled with a feature dimension of 64, and the attention heads are configured with 32 channels at the corresponding attention stages.
To enable scalable generation across heterogeneous imaging domains and modalities, we adopt a universal compositional conditioning strategy. The conditioning representation consists of three disentangled components: domain, object, and contrast embeddings. Specifically, the model contains 3 domain categories, 12 object categories, and 9 contrast categories, with each component represented in a 64-dimensional embedding space. The final conditioning representation is obtained by combining these components, allowing the model to generate unseen domain-object-contrast combinations without additional target-modality training.
The diffusion model is trained for 500 epochs with a batch size of 4 using the Adam optimizer with a learning rate of . The learning rate is decayed with a factor of 0.9995 during training. We apply exponential moving average (EMA) to stabilize optimization, with an EMA decay factor of 0.999. We use a cosine noise schedule with 300 diffusion timesteps and adopt the velocity (v)-prediction parameterization. The model is trained with a unified objective across all imaging domains and modalities. To incorporate domain-specific physical constraints, we introduce a physics-guided regularization term during diffusion training. The physical loss is activated using a warm-up strategy, starting from epoch 100 and gradually increasing until epoch 150. The base physical loss scale is set to . This warm-up strategy allows the diffusion model to first learn the general latent distribution before introducing physics-based constraints.
C. Additional Experiments
While Table 1 in the main text reports results averaged across all backbones for each domain, Table 8 provides the per-backbone breakdown underlying that average. Compositional conditioning improves the majority of metrics in 10 of the 12 backbone–domain combinations with an available baseline, with the largest gain observed for 3DMedDiff, which improves on all 15 metric–domain combinations. The exception is MedLord on MRI and EM, where independently learned per-modality embeddings remain competitive, suggesting that backbone-specific embedding capacity can partially substitute for compositional structure in some settings. Fig. 4 visualizes generated volumes for all modalities.
Head CT Abdom. CT Chest CT Hemo. EM Apof. EM Hexa. EM Cubic EM Breast T1 Prost. T2 Prost. DWI Brain FLAIR Brain T2 Brain T1 Knee PD-FS Knee PD
Slice Index

Figure 4. Representative generated 3D volumes across all imaging modalities. Each row corresponds to one modality, and the 16 columns visualize axial slices from a single generated volume.
Table 8. Domain-level comparison between backbone-specific baseline conditioning and the proposed compositional conditioning across three imaging domains. Results are macro-averaged over modalities within each domain, including eight MRI modalities, four EM modalities, and three CT modalities. For MedLord, the backbone-specific baseline uses an independently learned embedding for each modality, whereas compositional conditioning uses the proposed domain–object–contrast representation. Other backbones retain their original conditioning mechanisms for the baseline setting.
| Backbone | Domain | VideoMAE-FD ↓ | VideoMAE-KID ↓ | I3D-FD ↓ | I3D-KID ↓ | JEDI ↓ |
|---|---|---|---|---|---|---|
| Backbone-specific baseline conditioning | ||||||
| MedLord | MRI | |||||
| EM | ||||||
| CT | ||||||
| Pixel Diffusion | MRI | |||||
| EM | ||||||
| CT | ||||||
| 3DMedDiff | MRI | |||||
| EM | ||||||
| CT | ||||||
| Medical Diffusion | MRI | |||||
| EM | ||||||
| CT | ||||||
| Compositional conditioning | ||||||
| MedLord | MRI | |||||
| EM | ||||||
| CT | ||||||
| Pixel Diffusion | MRI | |||||
| EM | ||||||
| CT | ||||||
| 3DMedDiff | MRI | |||||
| EM | ||||||
| CT | ||||||
| Medical Diffusion | MRI | |||||
| EM | ||||||
| CT | ||||||
| SciFusion (Ours) | MRI | |||||
| EM | ||||||
| CT | ||||||
Note: Underline values indicate the better result between baseline and compositional conditioning for the same backbone and domain.