arXiv:2610.30449cs.CEOct 2026

Manuscript Offprint

arXiv:2610.30449

Are Learned Vascular Tree Generators Better Than Conditional Resampling?

Reza Akbarian Bafghi, Sukirt Thakur, Maziar Raissi

Abstract

Fidelity scores compare generated vascular trees with held-out real trees, so by themselves they cannot detect reuse of training data. A training-free conditional resampler shows this. On coronary trees (ImageCAS) and on IntrA, about half of its branch records (branches with their parent context) are near-copies of training records. Yet on our two fidelity scores, 1-NNA on tree summaries and a parent-daughter dependence AUC, it has better point estimates than three learned baselines as retrained here. A training copy scores better still. Adding noise to the copied values traces a curve of fidelity against the measured branch-record near-copy rate. At their own coronary rates (at most 1.3%), two learned baselines lie above this curve (worse) on parent-daughter relations. VesselGPT is inconclusive against the curve, as it is against the resampler on IntrA and on scale-free tree features. The curve is a reference, not a bound: real validation trees lie below it on both coronary scores, so low near-copy rates are not a goal in themselves. Jittered training copies also lie below it. On coronary data, one with a near-copy rate of about 1% does so on the dependence AUC, and so does one whose stronger jitter ruins its tree summaries. On IntrA, a lightly jittered copy lies below it on 1-NNA. A matched near-copy rate therefore certifies neither score against perturbed copies. The study is exploratory. We offer the near-copy rate as a diagnostic, reported beside fidelity with three controls: a training copy, a jittered copy and real held-out trees.

1 Introduction

Figure 1 shows a right coronary tree that no model learned to draw. It was grown by lookup: at each branch, we found training bifurcations whose parent branch resembled the current one and copied the two daughters of one of them. Its three daughter pairs come from three different training patients, and every copied branch length matches its source to within 0.45 mm. The tree is new; its branch descriptors are not. Yet on held-out coronary trees derived from ImageCAS (Zeng et al., 2023), trees grown this way score closer to real trees than three published learned generators retrained from the authors' code. This paper asks what that result means for how tree generators are evaluated.

Synthetic vascular trees are wanted for what real cohorts lack: more anatomy. They can populate virtual cohorts for in-silico trials (Viceconti et al., 2021), provide ground truth for image analysis (Hamarneh & Jassi, 2010) and enlarge training sets. Learned generators now produce such trees as centerlines with radii: VesselVAE encodes a tree with a recursive variational autoencoder (Feldman et al., 2023), VesselGPT serialises a tree into node tokens and samples them autoregressively (Feldman et al., 2025), and PartVessel generates a key graph and then its vessel segments (Chen et al., 2025). Progress is judged by fidelity: a

∗^{*}Equal contribution.

A resampled tree

Figure

Copies sit on the diagonal

Figure

Figure 1: A resampled tree is a patchwork of training patients. Left: a right coronary tree generated by the resampler, each daughter pair coloured by the training patient it was copied from (grey: root); 2D projection on the tree's first two principal axes. The tree (three bifurcations) is the first in sampling seed 0 with 3–4 bifurcations whose sources are all different patients. Right: the length of each copied branch against the length of its training source; every point lies on the diagonal (largest gap 0.45 mm). Radii are copied as a ratio to the parent plus a slope, so absolute radii differ from the source, and the 3D path is drawn afresh.

generated set is compared with held-out real trees, for example by 1-nearest-neighbour accuracy (1-NNA; VesselGPT computes it on mesh points, we on 11 summary features per tree).

A generator that reassembles training bifurcations may offer less diversity than its sample count suggests: recombination can add whole-tree variation while reusing local branch descriptors, and the uses above depend on variation. The sharper problem is ranking. One might answer that resembling real anatomy is the whole point, so a generator that scores well has done its job. But fidelity scores compare the generated set with held-out trees from the same population; the training set never enters the computation (Figure 2a). Measured against held-out patients, a copied training tree is simply one more real tree, and a tree stitched from real bifurcations is made of real parts. On coronary data a verbatim training copy and real validation trees reach the same 1-NNA, although every branch record of the copy is a near-copy of a training record and only a few percent of the real trees' are (Figure 2b). Fidelity alone therefore cannot establish novelty or freedom from training reuse, and copying can lead a leaderboard built on it.

Copying must then be measured where it happens. A resampled tree is new as a whole, so a whole-tree distance to the training set sees little; its reuse sits in single bifurcations. We therefore measure it on branch records, a branch with its parent and closest sibling, and count how many generated records are closer to a training record than nearly all real held-out records are.

We treat the procedure that grew Figure 1, a training-free conditional resampler (the resampler), as a reference method. We put three questions to it and to VesselGPT, VesselVAE and PartVessel as retrained here (the learned baselines), on the coronary trees and on IntrA (Yang et al., 2020).

Q1: who tops the fidelity leaderboard? The resampler, although it optimises no parameters. Its lead over every learned baseline is detected on coronary data and over two of the three on IntrA, but on scale-free tree features no 1-NNA difference from VesselGPT is detected (Section 4).

Q2: is the winner generating something new? Only in part: about half of its branch records are near-copies of training records, and neither fidelity score notices (Section 5).

Q3: at the same near-copy rate, who wins? No learned baseline lies below the fidelity-versus-copying curve traced by the resampler with noise on coronary data: VesselVAE and PartVessel lie above it on parent-a Two distances

near-copy radius tqt_{q}

fidelity: compared with held-out trees

Figure

copying: distance to nearest training record

Training records

Held-out real records

★ Real validation trees

Training copy

b Same fidelity, different copying (coronary)

Figure

Near-copy rate (%)

Resampler

O A good generator (hypothetical)

Figure 2: A training copy and real validation trees get the same 1-NNA; only the near-copy rate separates them. (a) Schematic: discs mark the near-copy radius tqt_q (Section 3.4) around training records; a training copy, and a resampled record, can sit inside a disc. (b) Coronary test set: 1-NNA against the share of near-copied branch records ( q=5q = 5). The training copy (100% near-copies) and real validation trees (6.8%) have the same 1-NNA, 0.545; the resampler reaches 0.643 with 51.7%. Dotted: real test records, 5% by construction.

daughter relations, and VesselGPT is inconclusive. Held-out real trees and perturbed training copies do lie below it, so a matched near-copy rate informs the comparison but certifies neither score against perturbed copies (Section 6).

The answer to Q2 is the robust core of the paper: it rests on a verbatim training copy and the resampler, neither of which is learned. Q1 and Q3 apply only to the learned baselines as trained under our budgets (Section 3.3) and to our two fidelity scores, 1-NNA on tree summaries and a parent-daughter dependence AUC; both scores read branch values of the kind the resampler copies, so its lead is partly by construction. The study is exploratory; its scope is set out in Appendix A.

Contributions. First, a diagnostic: the branch-record near-copy rate next to every fidelity score, and the gap to the fidelity-versus-copying curve of the resampler with noise level λ\lambda, reported with three controls (training copy, jittered copy, real held-out trees; Appendix A). Second, evidence on two datasets that our fidelity scores do not penalise copied branch records, which the near-copy rate detects as proximity to training records and the whole-tree data-copying test (Meehan et al., 2020) does not.

Section 2 places the work among copying tests and example-based synthesis. Section 3 defines the resampler, the data, the controls and the scores. Sections 4 to 6 answer the three questions in turn, and Section 7 states the limits once and turns the findings into a protocol.

References (12)