arXiv:2610.30498cs.CEOct 2026

Manuscript Offprint

arXiv:2610.30498

CARS: a centerline-anchored attention surrogate for coronary blood flow on skeleton-generated lumen geometries

Reza Akbarian Bafghi, Sukirt Thakur, Maziar Raissi

Abstract

When the parameter of a PDE surrogate is the flow domain itself, the key/value set of an attention model must encode that domain. We present CARS (Coronary Artery Rapid Surrogate), a learned surrogate for the finite-volume solution map of the steady incompressible Navier–Stokes equations on coronary lumens built from image-derived centerlines. CARS maps a centerline with per-point lumen radius and a scalar inlet flow rate to pressure and velocity at arbitrary query points. The attention focal set is the case's own centerline, so geometry fusion costs O(Nnf)O(Nn_f) rather than O(N2)O(N^2) in the number of evaluation points. Trained per territory on 2,700 OpenFOAM solutions with synthetic focal lesions, CARS reaches relative ℓ2\ell_2 errors of 0.120/0.149 (pressure/velocity) on left-coronary and 0.063/0.119 on right-coronary test sets, in 87 ms per case against a solver wall-clock of 572–1,063 s. It outperforms four parameter-matched neural operators, and accuracy saturates eightfold below the operating focal count. Fractional flow reserve derived from the predicted pressure matches the CFD label at Pearson r=0.941/0.993r = 0.941/0.993 and reproduces the FFR ≤0.8\leq 0.8 decision in 97.7%/96.3% of held-out cases. The predicted velocity does not satisfy continuity closely enough for derived quantities, and the weights are territory-specific.

Keywords: operator learning, surrogate modeling, attention, coronary hemodynamics, incompressible Navier–Stokes, reduced-order modeling

∗^{*}Corresponding author.

Email addresses: reza.akbarianbafghi@colorado.edu (Reza Akbarian Bafghi), sukirt@angioinsight.com (Sukirt Thakur), maziar.raissi@ucr.edu (Maziar Raissi)

1^{1}These authors contributed equally.

Preprint submitted to Computer Methods in Applied Mechanics and Engineering

1. Introduction

Predicting blood flow in a patient-specific coronary artery is the evaluation of a parametric solution map whose parameter is the flow domain itself. Each evaluation solves the steady incompressible Navier–Stokes equations on a lumen reconstructed from one patient’s image, at a prescribed volumetric flow rate, and returns the pressure and velocity fields. The parameter is high-dimensional: a coronary tree varies in branching topology, in the number and caliber of its terminal branches, in curvature and torsion, and in the position and shape of focal narrowings, and no small set of shape parameters describes the family. One steady solve is inexpensive by the standards of computational fluid dynamics and expensive by the standards of a query: the pipeline that produced the reference solutions used here runs a fixed 4,000 SIMPLE (Semi-Implicit Method for Pressure-Linked Equations) iterations per case on a resolved hexahedral mesh (Appendix F).

Two families of methods address parametric PDEs of this kind, and neither closes this one. Projection-based reduced-order models require a trial space that transfers across the parameter set; when the parameter is the domain, that needs a common reference configuration and a family of regular deformations onto it, which a vascular tree of varying branch count and connectivity does not admit. Learned surrogates on fixed grids meet the opposite obstruction, since an intra-luminal volume is neither structured nor of fixed extent. Attention-based surrogates act on point sets, but attention over the volume costs O(Nv2)O(N_{v}^{2}), and a coronary volume needs many points: the resolution requirement is set by the throat of the tightest stenosis, while the quantity of interest is a pressure difference across it.

The structure this work exploits is that the domain family, while not low-dimensional as a set of shapes, is generated by a low-dimensional object: a vessel is a tube about a curve, and that curve together with a per-point lumen radius already carries the geometric information on which the solution depends most strongly. We therefore use the patient-specific centerline as the focal (key/value) token set of a tiered attention mechanism: queries are formed from all tokens, keys and values only from the centerline, so cost is O(Nvnf)O(N_v n_f), linear in the number of evaluation points, and the focal set is given by the geometry. Two further elements complete the map: the evaluation points enter as an argument, so one set of weights answers at any evaluation density in the range tested; and the scalar flow rate enters multiplicatively, by feature-wise linear modulation, the form consistent with the approximately linear pressure-flow scaling of this regime. The construction is not specific to the coronary tree; §6.4 gives the input contract it asks of a new setting.

Figure

Figure 1: CARS at a glance. From a CT-derived coronary centerline (with per-point lumen radius and a set of intra-luminal volume points) and a scalar inlet flow rate Q, CARS predicts volumetric pressure and velocity fields in 87 ms (fp32) per case. The CFD time in panel 2 is the reference solver stage only: a measured median of 572 s (RCA) and 948–1,063 s (LCA) on eight MPI ranks. Panel 3 shows one predicted case, with pressure shown as the pointwise ratio to the aortic pressure PaP_a and velocity as magnitude in mm/s; the relative ℓ2\ell_2 errors beneath it are test-split means for each territory from the primary 300-epoch run. Panel 4 is the 286-case physiologic-range subset of the LCA endpoint analysis ( §\S5.4.1), classified at the FFR ≤\leq 0.8 threshold (positive: FFR ≤\leq 0.8); red quadrants mark disagreement with CFD.

The coronary circulation is the validation domain because its reference solutions are expensive, its geometry is image-derived, and it carries a scalar functional of the pressure field with an accepted decision threshold, so surrogate error is interpretable as a decision and not only as a norm. That functional is fractional flow reserve (FFR), the ratio of distal to proximal static pressure under hyperemia and the reference standard for deciding whether a coronary lesion is flow-limiting [1] in a disease that remains a leading cause of death worldwide [2]; obtaining it non-invasively by solving the Navier–Stokes equations on a lumen segmented from CT angiography agrees closely with the invasive measurement at the FFR ≤ 0.8 threshold [3, 4], and that CT-to-solution pipeline is what a surrogate of this map amortizes.

We build 6,600 steady finite-volume solutions across the two coronary

(a) Pipeline

Figure

(b) Tiered attention scores

(c) One CARS block

Figure

Figure

Figure 2: CARS architecture. (a) Two-stage tiered transformer. Stage 1 (geometry fusion) uses the centerline tokens as the focal set, and the centerline tokens Xc\mathbf{X}_c are discarded after it, so only the volume tokens Xv\mathbf{X}_v pass to Stage 2. Stage 2 (field refinement) uses a uniformly random subsample of the volume tokens as anchors (the focal set); at the operating point Nva=NvN_{\mathrm{va}} = N_v, so every point is an anchor. FiLM modulates post-Stage-2 volume features by the inlet flow rate QQ, and a single linear layer reads out per-query kinematic pressure p^j\hat{p}_j and three-component velocity u^j\hat{\mathbf{u}}_j. (b) Tiered attention: queries come from all NN tokens and keys and values from the nfn_f focal tokens only, so the score matrix is N×nfN \times n_f. Its upper nf×nfn_f \times n_f block is the intra-focal attention, the property that distinguishes tiered from plain cross-attention; the remaining N−nfN - n_f context rows read from the focal set but are never read from. At Nva=NvN_{\mathrm{va}} = N_v Stage 2 has no context rows and is full self-attention. (c) Each block applies pre-LayerNorm multi-head tiered attention, with keys and values taken from the focal rows of the normalized sequence and a learned attention-level positional bias on the projected queries and keys (the default for all CARS results; RoPE3D is the comparison variant), then a GELU feed-forward network, each with a residual connection.

territories and evaluate the resulting surrogate, CARS (Figures 1 and 2), against the 300-case held-out split of each: in discrete field norms, in cost, in sensitivity to the geometric arguments, and through the FFR functional of the predicted pressure field. CARS as specified in §3 approximates this solution map more accurately than the four neural-operator baselines and the alternative focal representations evaluated here, at parameter counts within 3% and on identical splits, and the FFR functional read off its predicted pressure reproduces the reference solver's FFR ≤ 0.8 decision in 97.7% (left coronary artery, LCA) and 96.3% (right coronary artery, RCA) of held-out cases. Pressure relative ℓ2\ell_2 on the test split is the primary endpoint; velocity, the endpoint and cost are secondary. We hypothesize that what matters is that the focal set is attached to the object the domain is generated from, not the number of focal tokens or the geometry they carry; the ablations are consistent with that hypothesis but do not isolate it, since every arm which moves the focal set off the centerline also changes the geometric channels or the positional treatment ( §5.2§5.2). Table 1 states the scope of the evidence.

The contributions, in the order the experiments take them, are:

  1. A focal set given by the geometry. An anchored-attention surrogate for the parametric steady incompressible Navier–Stokes problem on centerline-derived vascular domains, whose attention focal set is the centerline with its radius profile, so that geometry fusion is linear in the evaluation count.

  2. The evaluation set as an argument of the map. The points at which the solution is requested are supplied at inference: pressure error varies by at most 0.004 over the 16-fold range from 4,096 to 65,536 points, inside an equivalence margin of 0.005 (Table 5).

  3. Two architectural findings at matched parameter count. A learned attention-level coordinate embedding lowers error by 27–30% relative to a parameter-free 3D rotary encoding [5] at +0.3% parameters, with a frequency-scale confound noted in §3.3.1; and centerline anchors outperform both learned inducing points [6] and anchors subsampled from a surface discretization [7], while accuracy saturates eightfold below the operating focal count.

Relation to a companion paper by the same authors. A companion paper by the same authors predicts surface pressure and wall shear stress on coronary geometries through an anisotropic radial-basis decoder [8]. The two share the ImageCAS source of their geometries (98 of the 101 left-coronary and 130 of the 131 right-coronary base anatomies recur) and the OpenFOAM pipeline family, and nothing downstream of it: the tiered-attention construction, the volumetric prediction task, the input contract of §3.2 and every result reported here are introduced in this paper. The processed datasets are distinct (no left-coronary case is common to both, and the 794 right-coronary case names that recur carry different tensors), and no label field, trained weights, figure or table is shared.

References (57)