Manuscript Offprint
arXiv:2610.30498CARS: a centerline-anchored attention surrogate for coronary blood flow on skeleton-generated lumen geometries
Abstract
When the parameter of a PDE surrogate is the flow domain itself, the key/value set of an attention model must encode that domain. We present CARS (Coronary Artery Rapid Surrogate), a learned surrogate for the finite-volume solution map of the steady incompressible Navier–Stokes equations on coronary lumens built from image-derived centerlines. CARS maps a centerline with per-point lumen radius and a scalar inlet flow rate to pressure and velocity at arbitrary query points. The attention focal set is the case's own centerline, so geometry fusion costs rather than in the number of evaluation points. Trained per territory on 2,700 OpenFOAM solutions with synthetic focal lesions, CARS reaches relative errors of 0.120/0.149 (pressure/velocity) on left-coronary and 0.063/0.119 on right-coronary test sets, in 87 ms per case against a solver wall-clock of 572–1,063 s. It outperforms four parameter-matched neural operators, and accuracy saturates eightfold below the operating focal count. Fractional flow reserve derived from the predicted pressure matches the CFD label at Pearson and reproduces the FFR decision in 97.7%/96.3% of held-out cases. The predicted velocity does not satisfy continuity closely enough for derived quantities, and the weights are territory-specific.
Keywords: operator learning, surrogate modeling, attention, coronary hemodynamics, incompressible Navier–Stokes, reduced-order modeling
Corresponding author.
Email addresses: reza.akbarianbafghi@colorado.edu (Reza Akbarian Bafghi), sukirt@angioinsight.com (Sukirt Thakur), maziar.raissi@ucr.edu (Maziar Raissi)
These authors contributed equally.
Preprint submitted to Computer Methods in Applied Mechanics and Engineering
1. Introduction
Predicting blood flow in a patient-specific coronary artery is the evaluation of a parametric solution map whose parameter is the flow domain itself. Each evaluation solves the steady incompressible Navier–Stokes equations on a lumen reconstructed from one patient’s image, at a prescribed volumetric flow rate, and returns the pressure and velocity fields. The parameter is high-dimensional: a coronary tree varies in branching topology, in the number and caliber of its terminal branches, in curvature and torsion, and in the position and shape of focal narrowings, and no small set of shape parameters describes the family. One steady solve is inexpensive by the standards of computational fluid dynamics and expensive by the standards of a query: the pipeline that produced the reference solutions used here runs a fixed 4,000 SIMPLE (Semi-Implicit Method for Pressure-Linked Equations) iterations per case on a resolved hexahedral mesh (Appendix F).
Two families of methods address parametric PDEs of this kind, and neither closes this one. Projection-based reduced-order models require a trial space that transfers across the parameter set; when the parameter is the domain, that needs a common reference configuration and a family of regular deformations onto it, which a vascular tree of varying branch count and connectivity does not admit. Learned surrogates on fixed grids meet the opposite obstruction, since an intra-luminal volume is neither structured nor of fixed extent. Attention-based surrogates act on point sets, but attention over the volume costs , and a coronary volume needs many points: the resolution requirement is set by the throat of the tightest stenosis, while the quantity of interest is a pressure difference across it.
The structure this work exploits is that the domain family, while not low-dimensional as a set of shapes, is generated by a low-dimensional object: a vessel is a tube about a curve, and that curve together with a per-point lumen radius already carries the geometric information on which the solution depends most strongly. We therefore use the patient-specific centerline as the focal (key/value) token set of a tiered attention mechanism: queries are formed from all tokens, keys and values only from the centerline, so cost is , linear in the number of evaluation points, and the focal set is given by the geometry. Two further elements complete the map: the evaluation points enter as an argument, so one set of weights answers at any evaluation density in the range tested; and the scalar flow rate enters multiplicatively, by feature-wise linear modulation, the form consistent with the approximately linear pressure-flow scaling of this regime. The construction is not specific to the coronary tree; §6.4 gives the input contract it asks of a new setting.

Figure 1: CARS at a glance. From a CT-derived coronary centerline (with per-point lumen radius and a set of intra-luminal volume points) and a scalar inlet flow rate Q, CARS predicts volumetric pressure and velocity fields in 87 ms (fp32) per case. The CFD time in panel 2 is the reference solver stage only: a measured median of 572 s (RCA) and 948–1,063 s (LCA) on eight MPI ranks. Panel 3 shows one predicted case, with pressure shown as the pointwise ratio to the aortic pressure and velocity as magnitude in mm/s; the relative errors beneath it are test-split means for each territory from the primary 300-epoch run. Panel 4 is the 286-case physiologic-range subset of the LCA endpoint analysis ( 5.4.1), classified at the FFR 0.8 threshold (positive: FFR 0.8); red quadrants mark disagreement with CFD.
The coronary circulation is the validation domain because its reference solutions are expensive, its geometry is image-derived, and it carries a scalar functional of the pressure field with an accepted decision threshold, so surrogate error is interpretable as a decision and not only as a norm. That functional is fractional flow reserve (FFR), the ratio of distal to proximal static pressure under hyperemia and the reference standard for deciding whether a coronary lesion is flow-limiting [1] in a disease that remains a leading cause of death worldwide [2]; obtaining it non-invasively by solving the Navier–Stokes equations on a lumen segmented from CT angiography agrees closely with the invasive measurement at the FFR ≤ 0.8 threshold [3, 4], and that CT-to-solution pipeline is what a surrogate of this map amortizes.
We build 6,600 steady finite-volume solutions across the two coronary
(a) Pipeline

(b) Tiered attention scores
(c) One CARS block


Figure 2: CARS architecture. (a) Two-stage tiered transformer. Stage 1 (geometry fusion) uses the centerline tokens as the focal set, and the centerline tokens are discarded after it, so only the volume tokens pass to Stage 2. Stage 2 (field refinement) uses a uniformly random subsample of the volume tokens as anchors (the focal set); at the operating point , so every point is an anchor. FiLM modulates post-Stage-2 volume features by the inlet flow rate , and a single linear layer reads out per-query kinematic pressure and three-component velocity . (b) Tiered attention: queries come from all tokens and keys and values from the focal tokens only, so the score matrix is . Its upper block is the intra-focal attention, the property that distinguishes tiered from plain cross-attention; the remaining context rows read from the focal set but are never read from. At Stage 2 has no context rows and is full self-attention. (c) Each block applies pre-LayerNorm multi-head tiered attention, with keys and values taken from the focal rows of the normalized sequence and a learned attention-level positional bias on the projected queries and keys (the default for all CARS results; RoPE3D is the comparison variant), then a GELU feed-forward network, each with a residual connection.
territories and evaluate the resulting surrogate, CARS (Figures 1 and 2), against the 300-case held-out split of each: in discrete field norms, in cost, in sensitivity to the geometric arguments, and through the FFR functional of the predicted pressure field. CARS as specified in §3 approximates this solution map more accurately than the four neural-operator baselines and the alternative focal representations evaluated here, at parameter counts within 3% and on identical splits, and the FFR functional read off its predicted pressure reproduces the reference solver's FFR ≤ 0.8 decision in 97.7% (left coronary artery, LCA) and 96.3% (right coronary artery, RCA) of held-out cases. Pressure relative on the test split is the primary endpoint; velocity, the endpoint and cost are secondary. We hypothesize that what matters is that the focal set is attached to the object the domain is generated from, not the number of focal tokens or the geometry they carry; the ablations are consistent with that hypothesis but do not isolate it, since every arm which moves the focal set off the centerline also changes the geometric channels or the positional treatment ( ). Table 1 states the scope of the evidence.
The contributions, in the order the experiments take them, are:
-
A focal set given by the geometry. An anchored-attention surrogate for the parametric steady incompressible Navier–Stokes problem on centerline-derived vascular domains, whose attention focal set is the centerline with its radius profile, so that geometry fusion is linear in the evaluation count.
-
The evaluation set as an argument of the map. The points at which the solution is requested are supplied at inference: pressure error varies by at most 0.004 over the 16-fold range from 4,096 to 65,536 points, inside an equivalence margin of 0.005 (Table 5).
-
Two architectural findings at matched parameter count. A learned attention-level coordinate embedding lowers error by 27–30% relative to a parameter-free 3D rotary encoding [5] at +0.3% parameters, with a frequency-scale confound noted in §3.3.1; and centerline anchors outperform both learned inducing points [6] and anchors subsampled from a surface discretization [7], while accuracy saturates eightfold below the operating focal count.
Relation to a companion paper by the same authors. A companion paper by the same authors predicts surface pressure and wall shear stress on coronary geometries through an anisotropic radial-basis decoder [8]. The two share the ImageCAS source of their geometries (98 of the 101 left-coronary and 130 of the 131 right-coronary base anatomies recur) and the OpenFOAM pipeline family, and nothing downstream of it: the tiered-attention construction, the volumetric prediction task, the input contract of §3.2 and every result reported here are introduced in this paper. The processed datasets are distinct (no left-coronary case is common to both, and the 794 right-coronary case names that recur carry different tensors), and no label field, trained weights, figure or table is shared.
Table 1: What the evidence in this paper establishes, and what it does not. Each row on the right names the section that takes it up. G1–G3 are the three senses of generalization defined in §4.1.
| Established here | Not established here |
|---|---|
| Accuracy on unseen radius and flow combinations, on trajectories seen in training, against baselines matched to 3% on an identical partition (G1)That the margin is not bought by focal density or parameter count | Accuracy on unseen anatomies (G2) or unseen acquisition, site or population (G3); ~100 segmentations leave the former unresolved (§6.3)That focal-set provenance is what produces it, as opposed to the geometry it carries (§5.2) |
| Agreement with the CFD-derived FFR label at its threshold | Agreement with invasive wire-based FFR; no invasive measurement enters this work (§6.3) |
| Linear cost of geometry fusion in the evaluation count | Linear cost of the full model at the operating point, where Stage 2 is full self-attention (§5.3) |
| Pressure fields accurate enough to carry the endpoint | Velocity fields satisfying continuity or momentum balance closely enough for derived quantities (§5.5.2) |
| Performance on lumens generated as circular sections swept along a centerline | Transfer to independently segmented, eccentric lumens, where the centerline reduction stops being lossless (§6.3) |
| Weak sensitivity to evaluation density over a 16-fold range | Discretization invariance, and independence of the prediction from the rest of the query set (§5.5.2) |
| Separate models for the two coronary territories | Cross-territory transfer, which fails, and invariance to the acquisition frame, which the construction does not have (§5.5.3, §5.5.2) |
against invasive FFR in the DISCOVER-FLOW [9], DeFACTO [10] and NXT [4] trials, with per-vessel sensitivity broadly in the 80–90% band and more variable specificity (as low as 54% per patient in DeFACTO) at the FFR ≤ 0.8 threshold; the pipeline runs to hours per case even with cloud-based acceleration [11]. The classical route to a cheap parametric solver is projection: build a low-dimensional trial space from solution snapshots and project the governing equations onto it [12]. Two requirements make this family hard to apply here. Online efficiency needs affine parameter dependence, or empirical interpolation to approximate it [13], and the quadratic convective term needs hyper-reduction on top. More binding, when the parameter is the domain the snapshots live on different meshes, so a common basis exists only after all domains have been mapped to one reference configuration by a family of regular parametric deformations [14]. Such a family exists when the geometries deform one topology, the setting of cardiovascular projection ROM (Ballarin et al. [15] parametrize fixed-connectivity bypass grafts through their centerlines); it does not exist for an image-derived population of coronary trees whose branch count and connectivity differ between patients. One-dimensional models integrate the equations over the cross-section and solve a hyperbolic system on a network of segments, closed by a tube law and terminated by lumped-parameter models [16, 17]. They are cheap and topology-agnostic, but the trans-stenotic pressure loss enters through an empirical closure, and since the FFR endpoint is that loss, the closure sets their accuracy for the quantity of interest. A third strand parameterizes the shape by a fixed-length vector of stenosis descriptors or deformation control points, the assumption behind the 12,000 generated stenotic vessels of Itu et al. [11]. The lesions here are also generated from a low-dimensional radial deformation, so on that axis the settings are alike; what a fixed-length vector cannot encode is the image-derived trajectory and the variable branch count and connectivity. The surrogate developed here keeps the topology-agnostic character of the reduced models together with the volumetric output of the reference solve: a change of topology changes the token set, not the model.
Learned surrogates for cardiovascular flow simulation. Learning-based surrogates approximate the map from geometry and boundary conditions to solution fields, amortizing the solver over a population of cases, and are distinguished mainly by how they represent spatial structure. Convolutional networks [18, 19, 20, 21] require fixed Cartesian or projection-based discretizations, which restricts them on irregular patient-specific geometries. Graph neural networks [22, 23, 24] accommodate geometric variability but rely on local message passing, so long-range dependencies such as the pressure gradient across a stenosis cost depth. Operator-learning methods, including DeepONet [25] and Fourier neural operators [26, 27], learn maps between function spaces but in their standard forms assume structured discretizations or an explicit adaptation to complex geometry. Physics-informed neural networks [28] impose the equations through the objective but in their basic form require per-case optimization, so their cost is that of a solve; equation-discovery uses [29] and metalearned variants [30] relax parts of this, the latter amortizing across a parameter family, which is the property sought here by a different route.
Attention-based architectures for PDE surrogates. Attention was introduced for sequence modeling [31], carried to images [32, 33] and to unstructured point sets [34], and transfers to physical fields because it imposes no grid. Neural operators are constructed so that the approximation does not depend on the discretization [35]; for a model that takes the evaluation set as an argument the corresponding test is to vary the number of evaluation points at fixed weights (§5.3). Global attention over N tokens costs , and essentially every PDE transformer interposes an intermediate set of size : a fixed array of learned latents in Perceiver-IO [36] and the Set Transformer's inducing points [6]; orthonormalized neural eigenfunctions of the kernel integral operator [37]; learned physics slices to which tokens are softly assigned [38]; conditioning tokens in heterogeneous cross-attention with a mixture-of-experts stage [39]; or a subsample of the input point set, with surface points pooled to supernodes [7]. In each case the intermediate set is free parameters, a data-dependent soft partition, or a subsample of the discretization; in none is it a geometric object supplied by the problem. The anchors of AB-UPT (anchored-branched universal physics transformers) [7] are a subsample of a surface mesh, so the anchor count is a sampling hyperparameter and the input contract requires a surface triangulation; Transolver [38] recomputes its slices from token features in every layer, so its coarse space carries no geometric meaning and its size is chosen a priori. Here the geometry-conditioning focal set is the centerline itself, so its size is fixed by the arc length of the vessel; Stage 2 does designate volume anchors, but they are drawn from the evaluation set and carry no information the model would not otherwise have, whereas AB-UPT's anchors are the channel through which surface geometry enters. The baselines of §5.2.2 share one input contract, an unstructured geometric input with a set of evaluation points at matched parameter count. DeepONet's branch argument is a function on a fixed sensor set shared by no two patients; Fourier neural operators need a uniform grid; Geo-FNO [27] and GINO [40] map every geometry onto a fixed latent grid; and mesh-based message passing, of which MeshGraphNet [22] is representative, returns the solution at the vertices of a mesh it takes as input. These are excluded because they do not share the contract, not because of accuracy. Attention on point sets also needs coordinates to enter the score: sinusoidal [41] and rotary [5] encodings provide that without domain-specific structure, and §3.3.2 replaces the rotary construction with a learned coordinate embedding on the projected queries and keys.
Machine-learning estimation of the FFR endpoint. Itu et al. [11] introduced the scalar-feature route to FFR: a feed-forward network trained on ~12,000 synthetically generated stenotic geometries with CFD-derived labels and hand-engineered per-lesion descriptors, at sub-second inference, subsequently evaluated clinically [42]; reduced-order CFD prototypes of on-site ct-FFR were reported earlier still [43]. Across that lineage, including the MACHINE consortium evaluation [44] and deep models trained directly on CTA-derived geometry [45], reported per-vessel AUC against invasive FFR falls in the ~0.84–0.93 band, comparable to the CFD pipelines these models emulate. In that formulation the output is one scalar per lesion or vessel and the supervision target is itself a derived scalar, so the volumetric fields are unavailable for any other use; here the fields are predicted and FFR is extracted from them as a functional. Per-mesh-vertex prediction of hemodynamic scalars [24] sits between the two formulations.
3. Methodology
This section states the boundary-value problem being emulated, the map the surrogate approximates and what its inputs carry, and then the architecture that realizes the map.
3.1. Problem formulation
The boundary-value problem. Let denote a coronary geometry and the lumen domain it determines, with boundary , where is the inlet cap, the cap of the -th terminal branch, and the vessel wall. Blood is an incompressible Newtonian fluid in steady flow, so the velocity and pressure satisfy
in ,
(1)
in ,
(2)
with dynamic viscosity and density . The reference solutions take and in the pipeline's self-consistent (mm, s, kg) system, i.e. and in SI. The boundary conditions are
on ,
(3)
on ,
(4)
on .
(5)
The inlet carries a fixed kinematic pressure with the velocity left to the solution. Each terminal branch carries a prescribed volumetric flux, with the total flow distributed over the outlets in proportion to the square of the terminal lumen radius,
so that the mean velocity is equal across outlets (distinct from the scaling of Murray’s law [46]). The wall is rigid and no-slip.
Two properties of this problem define the parameter set the surrogate is trained over. First, the outflow distribution is prescribed and not obtained from a downstream resistance, impedance or Windkessel model; a steady resistance outlet would be admissible in exactly this formulation and is the more common choice [17]. With every terminal flux prescribed, a lesion cannot divert flow to a parallel branch, so the simulated pressure drop grows with severity without the flow reduction that accompanies it physiologically (§6.3), and the total flow , not the inlet pressure, parameterizes the operating state. Second, is sampled per case independently of the geometry, mm /s on the left coronary tree and mm /s on the right, so the parameter pair ranges over a product set and carries no mutual information with the anatomy; the pressure–flow relationship has to be represented explicitly.
Non-dimensionalization. Let be the proximal-segment lumen radius and take as the reference length, as the reference velocity, and as the reference pressure. In these scales Eqs. (1)–(2) carry the single parameter
which over the sampled flow ranges and calibers of this cohort is a few hundred at the inlet, the regime of resting and hyperemic coronary flow [3] (Appendix F gives the distribution and the larger throat values). At that Re the convective term is not small, so the approximately linear pressure–flow scaling this paper relies on has a different origin: away from throats and bifurcations the segments are slender and the flow nearly unidirectional and nearly fully developed, and for strictly unidirectional flow (u · ∇)u vanishes identically, so the axial pressure gradient balances the viscous wall stress alone and Hagen–Poiseuille holds at any laminar Re. In a slowly tapering duct the convective acceleration is largely reversible; the irreversible loss concentrates at throats and sudden expansions, where it scales quadratically with Q. The pressure drop is therefore linear in Q to leading order away from lesions and departs from linearity across them, which motivates the multiplicative flow-rate conditioning of §3.7.
The supervised pressure variable. The supervised pressure is the kinematic (static) pressure delivered by the incompressible solver, in ; “pressure” means this quantity throughout, and static pressure is the appropriate variable because FFR is a ratio of static pressures. The solver’s pressure is defined up to a constant, and the gauge used here refers it to the inlet, so in Eq. (10) is the norm of the pressure drop through the tree. This is the conservative choice: referring to absolute pressure would inflate the denominator by roughly two orders of magnitude and divide every relative error reported here by about the same factor, so comparisons against work reporting on absolute pressure are not like for like.
The solution map. Eqs. (1)–(5) define a solution map
assumed well defined and single-valued over the parameter range considered. The reference solver realizes a finite-volume discretization of , and it is that supervises training, so every error reported in this paper is agreement with . The grid-convergence study of Appendix F places within a median 2.0% (LCA) and 1.4% (RCA) of in a volume-weighted pressure norm and 0.3% in the velocity norm at production resolution.
The surrogate. The surrogate approximates pointwise. Its arguments are a centerline with the position of the -th centerline point and the local lumen radius; a scalar flow rate ; and a finite set of evaluation points . It returns the pressure and the three velocity components at those points,
with all trainable parameters and . Accuracy is measured in discrete norms over ; for pressure,
(10) and for velocity the same ratio over the full velocity block,
which is neither a mean over component-wise ratios nor an error on velocity magnitude. Both are computed per case on denormalized fields and averaged over cases. Because V is an argument of Eq. (9), one set of trained weights answers at any number and placement of evaluation points; §5.3 measures over a 64-fold range in . The scope is the evaluation set; the centerline is resampled to a fixed points throughout.
Two properties Eq. (9) does not have follow from its form. is a map of the whole set V and not a pointwise map applied times: the Stage-2 anchor subsample is drawn from V itself, so the predicted value at a fixed point depends on which other points were requested alongside it, a dependence §5.5.2 measures at 0.019 on pressure and 0.058 on velocity in relative . And acts on coordinate data in one fixed frame and is not equivariant under a rigid motion applied jointly to C and V, which the boundary-value problem is.
What the centerline argument asserts. The surrogate does not receive g. It receives , the centerline with its radius profile. On the family used here that is not a restriction: the reference geometries are generated from a centerline and a radius profile by the tubular construction of Eq. (13), discretized by a centerline-based mesher [47] whose cross-sections are circular by construction, so on this cohort is injective up to the mesher's deterministic normal-frame roll and determines completely; the centerline points supplied to the surrogate exceed the axial stations of the reference mesh. Two consequences follow. No claim here rests on cross-sectional shape being unimportant: what §5.2.2 tests is whether, at a comparable geometric input budget, a focal set on the generating skeleton is more accurate than one subsampled from a surface discretization of the same lumen, and the surface mesh AB-UPT [7] consumes is a deterministic function of here that encodes it more coarsely (8,192 points pooled to 1,024 supernodes). And injectivity is a property of this cohort, not of the method, so it governs transfer: applied to lumens with eccentric cross-sections and asymmetric plaque, ceases to be injective, and since training minimizes squared error over functions of under the geometry distribution , the minimizer is the conditional expectation over the fiber
whose within-fiber spread becomes an error floor for any model with these inputs. That floor is identically zero on the present cohort and would have to be measured on independently segmented lumens.
Why a one-dimensional skeleton is an effective reduced coordinate. Three properties of Eqs. (1)–(5) make an efficient reduced coordinate for S, and they are properties of the boundary-value problem and not of the architecture. The solution's dependence on the domain is strongly anisotropic: by the slenderness argument above, the axial pressure gradient integrates the radius profile along arc length, so a change to the trajectory or radius at one station propagates to the whole downstream subtree, while a change to cross-sectional shape at fixed area acts locally; a focal set on the centerline spans the direction of strongest dependence by construction. The axis is an intrinsic coordinate for this family of domains: away from bifurcations the lumen is a tubular neighborhood of a curve, and with the centerline parameterized by arc length, the lumen radius and a normal frame, the map
is a diffeomorphism onto the segment whenever the radius stays small relative to the local radius of curvature and the tube does not self-intersect, so retains the coordinate system in which axial and cross-sectional directions separate, and the focal-set size follows the arc length of the vessel and not the resolution of the discretization. And the alternative reduction is unavailable: a global reduced basis needs a common reference domain and a regular deformation family onto it, which varying branch count and connectivity do not supply, whereas a geometry-attached focal set moves with the domain. As a numerical scheme, the anchored attention that follows is a coarse update on the focal set followed by a prolongation to the volume, with no restriction, because the coarse variables are supplied and need not be inferred from the fine field; that is a design analogy and not an approximation bound in . It makes one testable prediction, which §5.5.1 measures: if the axis carries the strongest dependence and is supplied at full resolution, error should not degrade with operating point, vessel caliber or topological complexity.
3.2. Inputs and normalization
For each case the network is given: an ordered sequence of centerline points, each carrying the three coordinates and the lumen radius ; a set of evaluation coordinates ; and one scalar, the inlet flow rate . Nothing else: no edge list, no branch or segment identifier, no inlet or outlet flag, no tangent, normal or curvature, no arc-length coordinate, no per-outlet flux split, no wall distance and no surface mesh, so branching structure is present only insofar as the coordinates of the centerline sequence trace it. Every operation on centerline tokens is either position-wise or attention with the focal set defined by membership, and the attention-level encoding of §3.3 depends on the token's coordinate alone, so the network is permutation invariant in the centerline sequence and permutation equivariant in the evaluation set; we verified this (reversing or shuffling the centerline order changes the predicted fields by a relative of on pressure and on velocity, shuffling the evaluation set by , all reduction-order noise). The construction has no built-in invariance to rigid motions of the inputs.
All 3D coordinates, centerline and volume alike, are min-max normalized to using a fixed per-axis bounding box computed over all three splits (on LCA it coincides exactly with the training-set box),
with held fixed at inference. Scalar quantities are z-score normalized,
with computed once before training and held fixed at inference, because the pressure and velocity distributions are heavy-tailed and min-max scaling would compress the bulk of the distribution. Predictions are denormalized to physical units before any derived quantity is computed.
3.3. Spatial position encodings
CARS uses two mechanisms: a factored sinusoidal embedding used at the input stage to construct tokens, and an attention-level positional encoding inside each attention block, which makes the score between two tokens depend on their coordinates and not only on content similarity. Two attention-level options are compared in §5.2.1. The sinusoidal embedding allocates dimensions per axis (with divisible by 6); for each axis and pair index ,
and the per-axis embeddings are concatenated,
We make no extrapolation claim for the sinusoidal encoding, because the coordinates are min-max normalized per axis and the one out-of-range test we run fails outright ( 5.5.3).
3.3.1. 3D rotary position embeddings (RoPE3D)
RoPE rotates query and key vectors so that the dot product of the rotated , depends only on the relative position [5]. We extend it to 3D by partitioning each head's rotation pairs across the three axes as evenly as the head width allows and applying a 2D rotation per axis: with pairs on axis , pair rotates through , and the rotated query is with the block-diagonal rotation over that axis's pairs, and analogously for . The score then depends only on the coordinate displacement, componentwise in each axis, so it encodes Euclidean proximity directly; RoPE3D adds no learnable parameters, and a closely related axis-factored rotary encoding is used internally by AB-UPT [7]. The base is the language-model default, where positions are token indices running to or beyond; here coordinates lie in [0, 1], so the highest-frequency pair completes at most 0.16 of a cycle across the whole domain and nine of the eleven pairs on the first axis are small-angle everywhere. The learned alternative below can realize whatever length scale the problem wants, so the margin measured between them in §5.2.1 confounds the form of the encoding with the choice of frequency scale; the control, a RoPE3D run with the base rescaled to the lumen radius, has not been run. The full construction is in Appendix A.4.
3.3.2. Learned coordinate embedding
The alternative replaces the rotation by a learned additive bias on the projected queries and keys. A single two-layer MLP , of hidden width 64 with GELU activation, maps a token's coordinate to one bias vector per head,
and the head-h component is added to both the query and the key of token i after projection, so with rotation disabled the score between tokens i and j becomes
The last summand is a learned function of both coordinates and supplies a position-pair interaction, while the two cross terms let position modulate content; unlike RoPE3D it is not translation-invariant by construction. The cost is 12,736 parameters (+0.3%), and the learned variant is the default for all CARS results in this paper.
3.4. Tokenization of the vessel and the volume
Centerline geometry and volume query points are converted into token sequences of common width . Each centerline token combines a sinusoidal embedding of position with a learned embedding of radius by additive fusion,
while volume tokens carry only spatial information,
The two MLPs share architecture (two-layer GELU) but have independent weights, and additive fusion is adopted without an ablation isolating it. No a priori field values are provided at volume tokens, so all hemodynamic information must be propagated from the centerline tokens through attention.
3.5. Tiered attention with centerline anchors
With centerline tokens and volume tokens per case at the working point, standard self-attention over tokens is dominated by volume-to-volume interactions. In the laminar, pressure-driven, geometry-dominated regime of coronary flow, the pressure and velocity at an intra-luminal point are determined predominantly by the upstream centerline trajectory and the local lumen radius, the two quantities the centerline tokens encode, so the centerline can mediate long-range hemodynamic information across stenoses and branch points. We therefore split the token sequence into a small set of focal tokens (the centerline) and a large set of context tokens (the volume queries), and constrain attention to use only focal tokens as keys and values. With projections , , and ,
so queries are formed from all tokens while keys and values come from the focal tokens only. The attention matrix has shape , reducing memory from to and FLOPs from to , roughly a reduction in the geometry-fusion stage at the settings used throughout ( , ); the complete two-stage cost is Eq. (A.1). Because keys and values are drawn from the focal set alone, information never flows from the context tokens back onto it: the focal representation is updated by focal-to-focal attention, and the result is carried to the context tokens as a softmax-weighted combination of focal values, an interpolation with learned, query-dependent basis functions forming a partition of unity over the focal set. The focal tokens are not learned global parameters but are provided by the case's own centerline.
Tiered attention is applied independently across heads, each on a subspace with per-head projections , the head outputs concatenated and projected by ,
Each CARS block applies multi-head tiered attention followed by a position-wise feed-forward network, with pre-LayerNorm and residual connections,
where denotes the first rows of the normalized sequence and the FFN is a two-layer MLP with GELU activation and hidden width ; pre-LayerNorm gives more stable training dynamics with the asymmetric attention pattern [48]. The attention-level positional encoding enters the score inside Eq. (23): RoPE3D yields a locality prior by construction, whereas the learned embedding can represent one but is not guaranteed to.
3.6. Two-stage processing
The block stack is split into two stages with different focal/context partitions. Stage 1: geometry fusion. The concatenated sequence is processed by tiered-attention blocks with the centerline tokens as focal anchors ( ). Volume tokens acquire geometry-conditioned representations, while centerline tokens, which also appear as queries, attend to one another and propagate information along the vessel tree; the centerline tokens are then discarded. Stage 2: field refinement. The remaining volume tokens are processed by further blocks, where of the tokens act as volume anchors (focal) and the remaining queries attend to them. The anchors are a uniformly random subsample of the evaluation points, drawn per case with no learned or geometric selection rule, so the anchor set carries no information beyond the points themselves. The default is with no separate query set, equal to the training evaluation density, so at the operating point of every accuracy number in this paper every point is an anchor and Stage 2 is full self-attention; the anchor set becomes a strict subsample only when the model is queried above that density, the regime Appendix A.3 isolates for the linear-cost measurement. The two stages implement a coarse-to-fine flow: geometry conditioning establishes large-scale hemodynamic structure, and anchor-based refinement, in which anchors communicate through the query side of attention and query points interpolate from refined anchors, improves local consistency.
3.7. Flow-rate conditioning and decoding
After Stage 2 the volume tokens are modulated by the inlet flow rate Q via Feature-wise Linear Modulation (FiLM) [49]: a small MLP maps the normalized flow rate to per-feature scale and shift parameters, applied element-wise to the volume features,
with broadcast across volume tokens, and the final layer initialized so that FiLM is the identity at the start of training. A multiplicative modulation is the physically appropriate form because pressure scales approximately linearly with Q at fixed geometry over the sampled range ( ); with , Eq. (28) reproduces that scaling up to the affine offsets of the normalization, and the network need only correct the offset.
A single linear layer then maps each modulated volume token to four output channels, , so any spatial variation in the predicted fields is produced upstream of the readout; predictions are denormalized before any clinical metric is computed.
4. Experimental Setup
4.1. Dataset
Coronary geometries are derived from the public ImageCAS dataset [50] of coronary CT-angiography volumes acquired at a single Chinese tertiary center; CFD simulations run on these geometries by the OpenFOAM pipeline of Appendix F produce the volumetric pressure and velocity fields used as ground truth. The unit of the dataset is a point of the parameter set of Eq. (8), not a patient: each ImageCAS segmentation supplies a centerline trajectory, and cases are drawn from it by imposing different synthetic focal narrowings on the radius profile (a radial deformation of the radius profile) and drawing a fresh Q for each. Each tuple is solved once, and the solutions are partitioned at random into 2,700 training, 300 validation and 300 test cases per territory. The split is over samples of the parameter set, the standard protocol for a parametric-PDE surrogate, and it is identical for every model compared in this paper (CARS, all four neural-operator baselines, every ablation arm, the 1D ROM and the scalar regressors), so all model-to-model comparisons are like-for-like. The 3,300 LCA cases come from 101 base anatomies and the 3,300 RCA cases from 131, so the trajectory component of g recurs across splits and cases within a split are not mutually independent: 39% (LCA) and 57% (RCA) of the variance in per-case pressure error lies between patients. All confidence intervals on the FFR endpoint are accordingly computed by resampling patients. A median of 35 (LCA) and 28 (RCA) cases derive from each anatomy, and 34 (LCA) and 22 (RCA) of the 300 test cases are identical in both trajectory and radius profile to a training case and differ only in Q. Excluding those cases raises the mean pressure error from 0.117 to 0.127 on LCA and from 0.063 to 0.065 on RCA, and the velocity error from 0.147 to 0.155 and 0.119 to 0.122 (Appendix B.5).
A claim that a surrogate “generalizes” can mean three things here. G1, parameter-space generalization: unseen combinations of radius perturbation and inlet flow rate, on centerline trajectories seen during training; every field error and endpoint figure in this paper measures this. G2, anatomy generalization: unseen centerline trajectories, from segmentations absent from training; the reported numbers do not measure it, and 101 and 131 segmentations leave an anatomy-disjoint partition about a dozen independent test anatomies, so the experiment was run and is reported in Appendix E.1.
Table 2: Cohort summary for the LCA and RCA datasets, computed on the centerlines and CFD outputs used in this work. Patient age and sex are omitted: ImageCAS [50] reports them for the collection as a whole and not for the per-territory subsets drawn here, and no analysis is stratified by them. Lesion severity is Eq. (D.2), the fractional radius deficit relative to the reference shoulder radius; the FFR-positive rate (CFD-derived FFR on the filtered [0.3, 1.0] subset) is reported on the test split.
| LCA | RCA | |
|---|---|---|
| Cases (train / val / test) | 2,700/300/300 | 2,700/300/300 |
| Base anatomies (segmentations) | 101 | 131 |
| Source | ImageCAS | ImageCAS |
| Acquisition | Coronary CTA | Coronary CTA |
| Inlet flow-rate range (mm3/s) | U(5,000, 8,000) | U(2,500, 4,500) |
| realized mean ± sd | 6,431 ± 875 | 3,515 ± 571 |
| equivalent (mL/min) | ≈386 | ≈211 |
| Centerline length, median (mm) | 182 | 146 |
| Lesion severity, median | 0.46 | 0.24 |
| ≥ 0.30 (test set) | 91% | 45% |
| FFR ≤ 0.8 rate (n) | 21% (61/286) | 32% (93/293) |
G3, clinical generalization: unseen acquisition protocol, scanner vendor, site or population; not tested here. The cross-territory experiment of §5.5.3 bears on neither G2 nor G3 directly.
Each case contributes a centerline resampled to 2,048 points via branch-aware arc-length interpolation with per-point lumen radius, 16,384 volume points subsampled per epoch from the simulation domain, and per-point targets (kinematic pressure and three-component velocity). The volume subsample is drawn uniformly at random over the cell centers of the reference mesh, not over volume; since the mesher grades cells towards the wall, with a near-wall cell height of of the local radius, this measure weights the near-wall region more heavily than a volume-weighted norm, and the field errors of Eqs. (10)-(11) are to be read in that measure. It differs from the volume-weighted norm of the grid-convergence study, so the two are not directly comparable. Cohort summary statistics are given in Table 2.
4.2. Baselines and comparisons
CARS is evaluated along two axes. First, against four established architectures adapted for volumetric hemodynamic prediction: GNOT [39], ONO [37], Transolver [38] and AB-UPT [7], all with parameter counts within of CARS (range 3.76–3.87M) and trained on the same dataset with iden-tical preprocessing. Second, through component ablations that isolate each design choice: positional-encoding mechanism (RoPE3D vs. learned bias), attention structure (tiered vs. cross-only vs. Perceiver bottleneck), conditioning (FiLM vs. concat vs. none), anchor design (centerline vs. learned inducing points), and two-stage vs. single-stage architecture.
4.3. Metrics
We report normalized MSE during training (the optimization target), relative error on denormalized pressure and velocity fields, per-case inference latency on a single A100 80 GB, and the downstream FFR endpoint (Pearson r, ROC AUC, Bland–Altman bias and limits of agreement, threshold accuracy at FFR 0.8 with 95% CIs) against the CFD-derived label. The primary endpoint is the mean relative error of the pressure field, Eq. (10), on the held-out test split in the cell-center measure of §4.1: pressure is the field the clinical functional depends on and the field on which the reference solver's discretization error has been quantified. Velocity error, the FFR statistics and cost are secondary endpoints, and no claim rests on a velocity or endpoint margin alone. This hierarchy was not registered in advance, so it does not license the multiplicity control a pre-specified analysis plan would.
4.4. Training
The model is trained to minimize normalized mean squared error on pressure and velocity components at every volume query point; relative on denormalized predictions is the evaluation metric, so the numbers are scale-free across vessels of different size. Optimization uses AdamW [51] with learning rate , weight decay 0.05, cosine annealing with 5% linear warm-up and an end learning rate of , gradient clipping at global norm 1.0, dropout 0.1, and a parameter EMA with decay 0.9999 for evaluation. We train at batch size 1 (larger batches destabilized the AdamW optimization in our setup). Default architecture: , , , . Two training budgets are reported: a 100-epoch budget for matched comparison against the neural-operator baselines, and a 300-epoch budget adopted as the primary configuration after the hyperparameter sweep of §5.3 showed that the model had not saturated at 100 epochs. Full hyperparameters and per-baseline configurations are in Appendix A and Appendix C.
5. Results
5.1. It reproduces the reference fields
CARS in its primary 300-epoch configuration reaches a mean test relative error of 0.116/0.146 (pressure / velocity) on LCA and 0.063/0.119 on RCA against the CFD reference in a single run; retraining the LCA configuration from three seeds, identical in every respect but the initialization, gives (mean s.d., n = 3; Table 4), the figures quoted as the headline, while the RCA figures are one run with no seed spread measured. The typical case is considerably more accurate than the mean: on LCA the pressure error has median 0.065, roughly half the mean, with ninetieth and ninety-fifth percentiles of 0.288 and 0.432; on RCA the median is 0.041 with percentiles 0.121 and 0.188; velocity is the more uniform field, its mean and median differing by 0.017 (LCA) and 0.014 (RCA) against 0.053 and 0.023 for pressure. The means are what every comparison in this paper is made on, for comparability with the baseline literature, and they are set by a right tail: the worst LCA case reaches 0.950 and 3.7% exceed 0.5, against a worst RCA case of 0.494 and none above 0.5 (Table B.3); §5.5.1 identifies what the tail cases have in common. Per-case latency is 87 ms in fp32 on a single A100. Figure 3 shows a flow-limiting LCA case chosen for being typical (pressure error 0.060, just below the cohort median; CFD-derived FFR of 0.74 reproduced exactly): the predicted pressure reproduces the along-vessel gradient and the caliber-driven drop into the distal branches, the predicted velocity magnitude reproduces the low-velocity bulk and the localized stenosis jet, and the signed residual is low in amplitude, spatially smooth, of either sign and largest along the proximal segment, not a localized defect at the throat.
These errors are quoted against a reference whose own accuracy is measured. A three-level grid-convergence study on the upstream solver (Appendix F) puts the discretization error of the reference fields at a median 2.0% (LCA, interquartile range 1.14–5.86%) and 1.36% (RCA, 0.73–2.37%) in a volume-weighted pressure norm and 0.3% in the velocity norm at production resolution, with a median observed order of 2.51 on pressure. The reference error is smaller than the surrogate error on the median case by about a factor of three, though in a different norm. At the 20 mm endpoint station the reference labels sit a median of 0.0010 from their grid-extrapolated values, against a surrogate MAE of 0.008 on RCA and 0.019 on LCA, roughly eight and nineteen times the label bias; iteration error is smaller still, at relative on pressure and on FFR.
5.2. How much the focal set matters
Three measurements bear on the generating-object hypothesis of §1 without identifying it: what happens when the focal set is replaced, how accuracy depends on its size, and how the complete construction compares with architectures that reach the same geometry by other means. The identifying
CFD FFR = 0.74 CARS FFR = 0.74

Figure 3: Volumetric field prediction versus CFD on a flow-limiting LCA case (CFD FFR = 0.74, CARS 0.74; relative pressure error 0.060, just below the cohort median). Top: normalized kinematic pressure: CFD (left), CARS (center), signed error (right). Bottom: velocity magnitude, same order. The CFD and CARS columns share a color scale; error panels use a symmetric diverging scale at the 95th percentile of . The viewing direction projects the tree with least self-overlap and is shared by all six panels.
experiment would hold the focal token count, the geometric information supplied to the focal tokens and the positional treatment fixed, and vary only where the focal points sit: on the centerline in one arm, and at the same number of interior points of the same lumen in the other, each carrying the same per-point radius channel. Neither arm below is that experiment: the learned-anchor arm removes the radius profile and the Stage-1 positional encoding along with the geometric attachment, and AB-UPT differs in encoder, positional treatment and conditioning as well as in anchor provenance. What the measurements do establish is a bound: the focal set is not doing the work through sheer density, because accuracy saturates eightfold below the operating focal count, and not through a parameter advantage, because every arm is matched to within 3%.
5.2.1. Component ablations
CARS makes five architectural choices that depart from generic transformer surrogates: an attention-level positional encoding, FiLM flow-rate conditioning, tiered attention with geometry-defined focal tokens, centerline-derived anchors, and a two-stage architecture. Each is ablated at parameter-
Table 3: Component ablations on the LCA dataset at the matched 100-epoch budget, validation relative error, all configurations parameter-matched to within ( for the Perceiver variant; "Remove FiLM" deletes the conditioning pathway). The component rows use the RoPE3D reference (0.205/0.287); the paired positional-encoding head-to-head was a separate re-run whose RoPE3D figure (0.199/0.269) differs from it by the run-to-run spread (Appendix B). "noRoPE" removes the rotary encoding inside attention; "cross-only" additionally removes self-attention among focal tokens. Learned-PE-backbone rows are compared against the learned-PE reference.
| Group | Variant | Params | Pressure | Velocity |
|---|---|---|---|---|
| Reference | CARS, RoPE3D (component reference) | 3,844,548 | 0.205 | 0.287 |
| Positional encoding | RoPE3D (paired re-run) | 3,844,548 | 0.199 | 0.269 |
| Learned PE (default) | 3,857,284 | 0.140 | 0.196 | |
| Attention | Tiered noRoPE | 3,844,548 | 0.221 | 0.275 |
| Cross-only (noRoPE) | 3,844,548 | 0.262 | 0.638 | |
| Tiered → Perceiver | 3,951,372 | 0.354 | 0.559 | |
| Conditioning | FiLM → Concat | 3,844,356 | 0.224 | 0.240 |
| Remove FiLM | 3,745,348 | 0.329 | 0.487 | |
| FiLM → Concat, learned-PE backbone | 3,857,092 | 0.164 | 0.220 | |
| Architecture | CL anchors → Learned (512) | 3,831,300 | 0.385 | 0.434 |
| Two-stage → Single-stage | 3,844,548 | 0.176 | 0.386 | |
| Two-stage → Single, learned-PE backbone | 3,857,284 | 0.150 | 0.261 |
matched budget on the LCA cohort under the 100-epoch protocol, reporting validation relative error (Table 3). The component ablations use the RoPE3D variant as reference, and the two rows whose RoPE3D deltas were small or sign-ambiguous were also run on the stronger learned-PE backbone; what each arm receives, and the run-to-run bounds for the deltas, are in Appendix B.
Positional encoding. A small learned coordinate embedding (+0.3% parameters) reduces pressure error by 30% and velocity error by 27% relative to the parameter-free 3D rotary construction (0.199/0.269 → 0.140/0.196), and is the default in all subsequent CARS configurations. The margin is a comparison of implementations: the rotary arm inherits the wavelength base from language modeling while coordinates here live in [0, 1] (§3.3.1), so part of the margin may be the frequency scale and the comparison at a tuned base is a control we have not run.
Focal self-attention and the focal representation. Removing self-attention among focal tokens (cross-only) more than doubles velocity error; that variant also drops the rotary encoding, so the controlled comparison is against the noRoPE row, . Replacing tiered attention with a Perceiver-style latent bottleneck degrades both fields (0.354/0.559). Replacing the geometry-provided centerline anchors with 512 learned inducing points nearly doubles validation pressure error (0.205 → 0.385) and gives 0.434 on velocity; that arm removes the centerline coordinates, the radius profile and the Stage-1 positional encoding along with the geometric attachment (Appendix B), so it bounds the value of the whole geometry-attached focal representation and not of geometric attachment alone.
Conditioning and staging. Removing FiLM, so that Q does not reach the network at all, degrades both fields substantially (0.329/0.487). Replacing FiLM with concatenation is intermediate on the RoPE3D backbone but resolves uniformly in FiLM's favor on the learned-PE backbone (0.164/0.220 against 0.140/0.196). Collapsing the two stages into one shows a pressure–velocity trade-off on RoPE3D (0.176/0.386) and resolves uniformly in favor of two-stage on the learned-PE backbone (0.150/0.261 against 0.140/0.196).
Accuracy against the focal count. Since cost is nearly flat in (Appendix A.3), what accuracy does over the same range is the question that matters for the coarse-space reading. Thinning the 2,048-point centerline by uniform arc-length stride at fixed trained weights costs 0.0024 on pressure and 0.0021 on velocity for an eightfold reduction to 256 points, comparable to the seed-to-seed standard deviation and an order of magnitude below the error itself; only at 128 points does the error rise materially, by 0.017 on pressure (Table B.4). The knee sits near 256–512, where the arc-length spacing on a median 182 mm LCA centerline is 0.7–0.36 mm, comparable to the median lumen radius: the focal set has to resolve the radius profile at the scale of the lumen, and refining it beyond that buys nothing. The default is therefore well past the point of diminishing returns, which removes one explanation of the margins above and in §5.2.2, namely that CARS wins by attending to more geometry than the alternatives; it does not by itself show that the provenance of the focal set is what matters.
Run-to-run bounds. Every ablation is a single seed. Retraining the 100-epoch learned-PE configuration from three seeds gives a seed-to-seed standard deviation of 0.0026 on pressure and 0.0058 on velocity, and the two RoPE3D runs above give a more conservative two-point spread of 0.006 and 0.018; against either, the architectural effects the paper draws conclusions from are larger by on the relevant field (Appendix B).
5.2.2. Comparison with neural-operator baselines
Table 4 compares CARS against GNOT [39], ONO [37], Transolver [38] and an AB-UPT baseline [7] from the same architectural family, all matched in parameter count (3.76–3.87M) and trained on the same data with identical preprocessing. Two properties bound the comparison (Appendix C): the baselines were trained at CARS's optimizer settings and not at settings selected for each, and the flow-rate conditioning pathway is not matched across arms, so a quantified share of the gap over the three non-FiLM baselines is attributable to conditioning. The first three baselines are conditioned on the centerline only; AB-UPT consumes the surface mesh, which on this cohort encodes the same geometry the centerline determines (§3.1), so that comparison isolates the encoding. Under the matched 100-epoch budget, CARS test error is 0.150/0.199 against 0.444/0.686 for the strongest non-AB-UPT baseline (GNOT), a 66%/71% reduction; the val-to-test gap is small (~7% pressure, <2% velocity), and the parameter-free RoPE3D variant of CARS (0.201/0.272) still beats every baseline on pressure and all but AB-UPT on velocity, so the gain is not carried by the positional encoding alone. AB-UPT is the strongest baseline and shares anchor attention, rotary encoding and FiLM with CARS, so the residual gap localizes CARS's three additions: tiered centerline-focal attention, the learned coordinate embedding, and the two-stage separation. Retraining both arms from the same three random initializations gives for CARS against for AB-UPT at 100 epochs, paired differences of and ( , and , on two degrees of freedom). At 300 epochs, the budget the headline rests on, the same three seeds give a margin of 0.039 on pressure and 0.023 on velocity ( and ; , and , ), with CARS ahead on both fields at every seed. At a rank test cannot go below and the velocity margin misses ; what the design supports is that the difference is consistent in direction across every pair and several times the within-arm spread. The margin narrows by only a quarter between budgets, so the advantage is not primarily one of optimization speed; AB-UPT's seed spread is four times CARS's; and the single AB-UPT run in the table is that arm's best of four. Neither arm is at its asymptote, so this is a fixed-budget comparison. In latency, the pure-transformer baselines are faster (9–23 ms) because they avoid the concatenated focal-context attention over tokens, and AB-UPT is slower (166 ms) because of its branched surface+volume decoder; the one model in the same accuracy band as CARS is slower and every faster model
Table 4: Baseline comparison on the LCA dataset at parameter counts within 3% of CARS. Relative error on pressure / velocity in fp32; latency (ms) is the median per-case fp32 forward pass on a single A100 80 GB (batch 1, 16,384 volume points, 2,048 centerline points). marks models that consume the surface mesh in place of the centerline. The 300-epoch single runs are each arm's most favorable seed, so the single-run gap is not the margin; matched-seed rows retrain both arms from the same three initializations (mean s.d.), and the 300-epoch matched row is the headline. The reference solver's median wall-clock is 572 s (RCA) and 948–1,063 s (LCA) on eight MPI ranks of an Azure F16s_v2 node (§6.2). *bfloat16. n/a: latency and validation error are reported for the single runs only.
| Model | Params | ms | Val. p | Val. u | Test p | Test u |
|---|---|---|---|---|---|---|
| 100 epochs, single run | ||||||
| CARS (learned PE) | 3.86M | 87 | 0.140 | 0.196 | 0.150 | 0.199 |
| CARS (RoPE3D) | 3.84M | 87 | 0.199 | 0.269 | 0.201 | 0.272 |
| AB-UPT | 3.76M | 166 | 0.197 | 0.252 | 0.211 | 0.254 |
| Transolver | 3.81M | 8.7 | 0.518 | 0.714 | 0.514 | 0.718 |
| GNOT | 3.87M | 21.4 | 0.430 | 0.688 | 0.444 | 0.686 |
| ONO | 3.84M | 22.5 | 0.835 | 0.970 | 0.804 | 0.957 |
| 100 epochs, three matched initializations per arm | ||||||
| CARS (learned PE) | 3.86M | n/a | n/a | n/a | 0.153 ± 0.003 | 0.205 ± 0.006 |
| AB-UPT | 3.76M | n/a | n/a | n/a | 0.205 ± 0.003 | 0.231 ± 0.008 |
| 300 epochs, single run (CARS seed 42, AB-UPT seed 1234) | ||||||
| CARS (learned PE) | 3.86M | 87 / 15* | 0.108 | 0.141 | 0.116 | 0.146 |
| AB-UPT | 3.76M | 166 | 0.133 | 0.157 | 0.130 | 0.162 |
| 300 epochs, three matched initializations per arm (headline) | ||||||
| CARS (learned PE) | 3.86M | n/a | n/a | n/a | 0.1198 ± 0.0032 | 0.1491 ± 0.0047 |
| AB-UPT | 3.76M | n/a | n/a | n/a | 0.1584 ± 0.0138 | 0.1723 ± 0.0106 |
is at least less accurate (Figure C.1). A dimensionally consistent one-dimensional Poiseuille-Bernoulli reduced-order model driven by the same outflow split reaches threshold agreement of only on the FFR endpoint (LCA/RCA), below the majority-class rate on LCA, because it does not resolve the trans-stenotic loss that sets the endpoint (Appendix D.4).
5.3. What it costs
Cost enters this construction twice: in how accuracy scales with the training budget and model size, and in how inference cost scales with the number of points at which the field is requested. A three-axis sweep over training length, depth and width (Table A.4) shows training length is the most effective lever per unit compute: epochs at the reference size reduces validation pressure error by and velocity error by at no parameter cost, doubling depth to blocks at 100 epochs matches what 200 epochs achieves at the parameters and the wall-clock per epoch, and widening to does not pay off within the 100-epoch budget. The 300-epoch run is therefore the primary configuration, with validation pressure still improving at that budget.
Three properties of the query-based formulation are measured on the trained checkpoint with no retraining (Table 5). First, evaluation density. Both fields converge from above: pressure is degraded only at the spars-est setting (0.137 LCA, 0.080 RCA at 1,024 points) and then moves by at most 0.004 over the 16-fold range from 4,096 to 65,536. Taking 0.005 as the equivalence margin, an order of magnitude above the standard deviation from resampling evaluation points (Appendix B) and comparable to the seed-to-seed spread, the whole interval lies inside the margin, so pressure error is statistically indistinguishable across a sixteenfold change in evaluation density; it does not follow that the map is discretization invariant in the sense a neural operator establishes by construction, and the result says nothing outside the tested range. Velocity is slower, reaching within 5% of its converged value at the trained density of 16,384 and within 2% by 32,768. Second, the linear-cost regime. Cost is linear in the evaluation count only when the Stage-2 anchor set is held fixed as that count grows (Eq. (A.1)), and every accuracy number so far is measured at , where it is not. Holding the evaluation budget at 16,384 points and reducing the anchor count, with the remainder supplied as pure query points, an eightfold reduction of the anchor set from 16,384 to 2,048 costs 0.008 on pressure error (7% in relative terms, while removing 87% of the quadratic term) and 0.073 on velocity, a 50% relative increase; pressure error at with 15,360 further query points (0.138) agrees to 0.001 with the error when only 1,024 points are requested (0.137), so accuracy is governed by the anchor count and query points beyond the anchor set are interpolated from it. A deployment that wants the FFR endpoint, a functional of pressure alone, at high evaluation density can therefore take the linear regime cheaply; one that wants resolved velocity fields cannot. Training directly in the linear regime, at and 22.5 ms per case, is worse on pressure (0.141 against 0.125 for the flagship thinned to the same anchor count) and better on velocity (0.202 against 0.220); the full fixed-anchor sweep and the measured scaling slopes are in Appendix A.3. Third, precision. bfloat16 raises pressure error by 21% on LCA (0.117 → 0.141) and 37% on RCA (0.064 → 0.088) and degrades velocity by a factor of ≈3.6; the FFR endpoint is correspondingly robust, threshold accuracy moving from 97.6% to 96.9% on LCA and from 96.6% to 96.9% on RCA (nearest-point protocol, physiologic-range subset). All field errors and endpoint metrics in this paper are therefore reported in fp32 at 87 ms per case, and the 15 ms bfloat16 figure is an operating point for the FFR endpoint specifically.
Table 5: Evaluation-density and precision sensitivity, mean relative over the full 300-case test split of each territory, trained weights unchanged; every requested point is a Stage-2 anchor. The fp32 precision row is the 16,384 density row on the identical evaluation points. The trained-density row reproduces the single-run headline to within 0.001.
| Setting | LCA | RCA | |||
|---|---|---|---|---|---|
| Pressure | Velocity | Pressure | Velocity | ||
| Density (fp32) | 1,024 | 0.137 | 0.302 | 0.080 | 0.267 |
| 4,096 | 0.120 | 0.175 | 0.065 | 0.140 | |
| 16,384 (trained) | 0.117 | 0.147 | 0.064 | 0.118 | |
| 32,768 | 0.116 | 0.143 | 0.063 | 0.116 | |
| 65,536 | 0.116 | 0.141 | 0.063 | 0.115 | |
| Precision | fp32 | 0.117 | 0.147 | 0.064 | 0.118 |
| bfloat16 | 0.141 | 0.532 | 0.088 | 0.426 | |
5.4. The derived endpoint
5.4.1. Fractional flow reserve endpoint
Field norms average over the domain. The FFR endpoint does the opposite: it is a scalar functional of the predicted pressure field evaluated at a single point, so it tests the field where a downstream decision is taken. Given a predicted pressure field on , the endpoint is
with the aortic reference pressure and a measurement point determined by the centerline alone: the lesion is the eligible centerline point of maximum radius deficit (Eq. (D.2)) and lies 20 mm of arc length distal to it within the same branch (Appendix D). Because depends only on , the identical functional is applied to the predicted and to the reference field, and any difference in FFR is a difference in the pressure field at that point. Because the evaluation set is an argument of the surrogate, the predicted pressure is read directly at by appending it to the standard 16,384-point query set, which removes the sampling variability of a nearest-neighbor lookup (a median 0.31 mm (LCA) and 0.35 mm (RCA) away, contributing about 0.01 of run-to-run variation in ); the reference is taken at the nearest production cell center, a median 0.12 mm (LCA) and 0.19 mm (RCA) away, and inverse-distance weighting over the eight nearest centers changes every statistic by less than 0.001. Exact querying changes no threshold decision on LCA and one on RCA, and improves the full-cohort LCA correlation from 0.921 to 0.941 (Table D.2). Every endpoint figure in this subsection and in Table 6 uses it; the sensitivity analyses of §5.4.2 and the precision comparison of §5.3 retain the nearest-point protocol on the physiologic-range subset, because each compares rows against a baseline computed the same way, so their baselines read 97.6–97.9% (LCA) and 96.2–96.6% (RCA), and no trend within them is affected.
On the full 300-case test split of each territory, with no exclusion of any kind, predicted and reference FFR agree at Pearson on LCA/RCA with MAE 0.026/0.010 and agreement at the FFR threshold of 97.7%/96.3% (3/5 false positives and 4/6 false negatives; Figure 4, Table 6). This full cohort is the primary analysis and the figure to compare against external reports. Restricting to the 286/293 cases whose reference FFR lies in the physiologic range [0.3, 1.0], the subset every sensitivity analysis uses so that its rows are mutually comparable, gives , MAE 0.019/0.008 and 97.6%/96.2%; the excluded tail is dominated by total occlusion and severe diffuse disease and changes the decision statistic by at most one case (Appendix D.3). Bland–Altman bias is negligible (+0.003 LCA, -0.001 RCA) with 95% limits of agreement [-0.082, +0.088] and [-0.030, +0.029], and ROC AUC for the threshold decision is 0.995/0.995 on that subset and 0.996/0.996 on the full cohort (Appendix D.3, Table 6). An Itu-style scalar regressor [11] and an XGBoost upper bound trained on the same splits and labels from 15 hand-engineered per-vessel geometric features reach AUC 0.92/0.88 and 0.96/0.93 on LCA/RCA against CARS's 0.995/0.995 on the same subset, with non-overlapping bootstrap 95% CIs (Table D.3), so the volumetric formulation contributes information for the endpoint that scalar feature regression does not extract; these AUCs are not comparable to the band of the prior literature [44, 42, 45], which is measured against invasive FFR on clinical cohorts. Evaluating Eq. (29) adds millisecond-scale post-processing to the forward pass.
5.4.2. Parametric sensitivity to the geometric inputs
The geometric argument of Eq. (9) is recovered from an image, so the practical question is how the map propagates a perturbation of it. We perturb the centerline positions and radius profile of each test case and re-evaluate the trained map, reading sensitivity through the endpoint functional, the most demanding readout of a local perturbation; both perturbation families leave the branch decomposition intact, so what is measured is sensitivity to the geometric parameters and not to topology (Figure 5; tables in Appendix D.6). Under independent per-point noise, LCA is unchanged by position perturbations up to mm, consistent with independent per-point displacements averaging out across the token set, while RCA, whose

(a) LCA

(b) RCA
Figure 4: Predicted vs. CFD-derived FFR on the physiologic-range subset of each territory, under the nearest-point lookup (); the primary exact-coordinate protocol of §5.4.1 gives on the same cases. Dotted lines mark the clinical FFR = 0.8 threshold; dashed line .
Table 6: Threshold-level operating point at FFR under the exact-coordinate protocol, on the full test split (primary) and on the physiologic-range subset. Intervals are patient-clustered nonparametric bootstrap CIs (): patients are resampled with replacement and all cases of a drawn patient enter together, so the 300 cases are treated as 96 (LCA) and 111 (RCA) independent units, and the subsets as 94 and 110.
| Metric | LCA | RCA | ||
|---|---|---|---|---|
| full (300) | subset (286) | full (300) | subset (293) | |
| Pearson r | 0.941 [0.921, 0.979] | 0.953 [0.923, 0.974] | 0.993 [0.987, 0.996] | 0.994 [0.991, 0.996] |
| MAE | 0.026 [0.017, 0.038] | 0.019 [0.015, 0.024] | 0.010 [0.008, 0.013] | 0.008 [0.007, 0.010] |
| ROC AUC | 0.996 [0.990, 0.999] | 0.995 [0.989, 0.999] | 0.996 [0.991, 0.999] | 0.995 [0.990, 0.999] |
| Sensitivity | 0.941 [0.875, 0.987] | 0.934 [0.861, 0.986] | 0.940 [0.894, 0.980] | 0.935 [0.888, 0.978] |
| Specificity | 0.987 [0.971, 1.000] | 0.987 [0.970, 1.000] | 0.975 [0.948, 0.995] | 0.975 [0.948, 0.995] |
| Accuracy | 0.977 [0.959, 0.991] | 0.976 [0.957, 0.990] | 0.963 [0.942, 0.983] | 0.962 [0.939, 0.983] |
trees are shorter and carry a single dominant trunk, loses three points of threshold accuracy at 0.5 mm (96.6% to 93.5%) and more at 1 mm. Radius perturbations degrade the endpoint at a rate consistent with the sensitivity of the viscous pressure drop: 5% relative noise leaves both territories intact, 10% produces moderate degradation on LCA while RCA is unaffected, and 20% degrades both substantially, so the radius argument is the binding one and the two territories are complementary. A spatially
(a) Centerline noise

Centerline noise (mm)
(b) Radius noise

Radius noise (frac)
(c) MC-dropout triage (val-tuned)

Test routing (%, val-tuned cutoff)
Figure 5: Robustness and uncertainty triage for the FFR endpoint (threshold accuracy at , nearest-point protocol, physiologic-range subset). (a) Centerline-position noise (additive isotropic Gaussian, mm). (b) Radius noise (multiplicative fractional Gaussian). (c) MC-dropout triage under a val-tuned protocol: the -percentile cutoff is set on the val split at the -th percentile for target routing fraction (dashed verticals) and applied unchanged to test; the plotted x-coordinate is the realized test routing fraction, and the 0% point is the MC-mean baseline.
correlated perturbation, one bias applied uniformly over a random 10 mm arc-length window, leaves both territories at their unperturbed operating point for position biases up to 2 mm, and at a 20% window-level radius bias LCA remains within 0.4 pp while RCA loses 1.3 pp, because only a 10 mm region is biased and the measurement point usually lies outside it. Finally, MC-dropout forward passes give a predicted standard deviation on the endpoint that correlates with its absolute error at but is overconfident as an interval ( coverage 52%/44% against a calibrated 68%), so it is used only as an ordering over cases: a -percentile cutoff set on the validation split and applied unchanged to test withholds the highest- cases and removes 31–61% of the summed endpoint error for 11–26% of cases, though on RCA at the 10% target the withheld cases carried error without carrying threshold errors (96.1% against 96.2% with no routing).
5.5. Error structure, invariances and transfer
5.5.1. Error versus geometric and flow complexity
Because the parameter pair is summarized by a small number of scalars, the per-case error of the primary configuration can be resolved against each of them (Figure 6; values in Table E.1), with rank correlations tested by a patient-clustered permutation and corrected for multiplicity across the twenty tests by Benjamini–Hochberg, since same-patient cases share the centerline exactly. No covariate produces a large or reliable dependence. Lesion severity shows the largest binned trend, a factor of 2.8 on LCA pressure from 0.069 to 0.190 across bands ( ), but the per-case p-values of 0.004 and 0.005 become q = 0.11 and 0.15 after clustering and multiplicity correction; severity and throat radius are strongly anti-correlated ( ) and cannot be separated on this sample, and RCA returns nothing ( ). Pressure error is insensitive to inlet flow rate ( ; RCA velocity error rises weakly, ), also within a patient where Q is essentially the only covariate that varies (within-anatomy LCA, +0.09 RCA), which is the behavior expected if the flow-rate dependence is carried by the multiplicative conditioning; inlet caliber is flat ( ), and lesion throat radius, the only caliber measure with a nominal signal, fails correction ( , p = 0.042 per case, 0.126 clustered, on LCA). Branch count is the one covariate whose association survives correction, on three of the four territory-field pairs (q = 0.034, 0.002, 0.006), but the dependence is weak, not monotone in the bins, and partly a proxy for tree extent ( with arc length on LCA). Set against per-case errors spanning a factor of 52 on LCA (0.018 to 0.950) and 38 on RCA, with the top decile carrying 40.5% (LCA) and 36.3% (RCA) of the summed pressure error, none of these locates where the surrogate is inaccurate: for the 44 LCA cases above 0.2, median severity, branch count and throat radius are 0.488, 4 and 0.668 mm against cohort medians of 0.463, 4 and 0.721 mm. The regimes in which the operator might have been expected to become harder to approximate (higher flow rates, smaller vessels, more branched trees) are not where this surrogate is less accurate, which is what one expects if the axis carries the strongest dependence and is supplied at full resolution; the residual that sets the mean is case-specific. It is a property of the cases and not of the optimization: across the three 300-epoch seeds, per-case pressure errors correlate at Pearson 0.89–0.93, and of the 44 worst cases per seed, 33 are in the worst 44 of all three (pairwise overlaps 36–38 against an expectation of 0.9 under independence), so ensembling over seeds would not remove the tail. Nor is it an artifact of the globally z-scored objective against a per-case relative metric: relative error correlates with per-case only weakly (Spearman -0.137) while absolute error rises with it (+0.574), and exactly 11 of the 44 worst cases fall in the smallest- quartile, the chance expectation. The tail is approximation error on specific geometries, reproducible and therefore available to be diagnosed.
5.5.2. What the construction does not enforce
The boundary-value problem is invariant under a rigid motion applied jointly to the domain and the points at which the solution is read, is pointwise in the sense that the solution at a location does not depend on which other locations are asked about, and satisfies Eqs. (1) and (2). CARS has none of
(a) Lesion severity

(b) Branch count
(c) inlet flow rate Q quartile
(d) Throat-radius quartile

Figure 6: Mean per-case pressure relative error by bin, with standard error of the mean, over the 300-case test split of each territory (bin definitions and velocity columns in Table E.1; all four panels share the vertical scale). Severity in (a) carries the largest trend of the four covariates, and only on LCA. Quartiles in (c) and (d) are per-territory. Bins with fewer than 10 cases carry wide intervals: severity on RCA ( ), two branches ( ) and branches ( ) on LCA.
these properties by construction, so how much each costs is a measurement, made on the trained LCA checkpoint with no retraining (Appendix E). Rotating the centerline and evaluation points jointly about the case centroid, scored against the unrotated reference with the predicted velocity counterrotated, two degrees of rotation or one millimeter of translation cost less than the seed-to-seed standard deviation; five degrees or two millimeters cost 15% and 8% of the pressure error; twenty degrees or ten millimeters raise it by a factor of three to three and a half; and a rotation drawn uniformly from leaves a median relative pressure change of 1.02, so the output is then unrelated to the correct one. Every geometry is expressed in one acquisition frame and the positional encodings act on absolute coordinates in it, so the tolerance measured here covers the residual misalignment of a consistently oriented cardiac CT series and not a different patient-positioning convention. Holding 2,048 points fixed and predicting them twice, each time embedded in a different set of 14,336 further points from the same case, the two requests disagree by a mean relative of 0.019 on pressure (median 0.015) and 0.058 on velocity, a sixth and two-fifths of the respective errors: the reported errors carry this much irreducible variation from the evaluation sampling alone, and fixing the anchor set to a deterministic function of the geometry would remove it at the accuracy cost bounded in Appendix A.3. Consistency with the governing equations, evaluated by automatic differentiation of the network on fifty test cases per territory with 4,096 interior points each and made dimensionless by the per-case mean speed U and median lumen diameter D, is loose: the median is 0.26 on LCA and 0.30 on RCA, so the local dilatation is of order a quarter of the characteristic velocity gradient, and the momentum residual scaled by has medians of 2.6 and 2.9, falling to 1.57 once points whose finite-difference Laplacian stencil leaves the lumen are removed, still of the order of the convective term. The inlet flux recovered from the predicted velocity by disc quadrature differs from the prescribed Q, an input delivered through a dedicated conditioning pathway, by a median of 12.2% on LCA and 5.5% on RCA. CARS therefore reproduces the reference fields in the supervised norms, and the derived pressure functional to within a few per cent, without preserving the governing equations pointwise: it approximates the solution map realized by a particular finite-volume discretization and does not inherit its conservation properties. Quantities that integrate the pressure field (pressure drops, the endpoint) are insensitive to residual error that averages out; quantities that differentiate the velocity field (wall shear stress, vorticity, dissipation) are not, and should not be read off this surrogate without physics-constrained training terms or a projection step enforcing after prediction.
5.5.3. Cross-territory generalization: RCA
Right coronary artery geometries differ from LCA in topology (typically a single dominant trunk), inlet flow rate (mean , of the LCA mean) and spatial distribution. Zero-shot LCA→RCA inference of the LCA-trained checkpoint reaches relative of order 8 on both fields even after re-normalizing spatial coordinates by the RCA-set bounding box, two orders of magnitude worse than the within-territory result: the flow-rate distributions are non-overlapping (a gap of standard deviations), so the FiLM pathway operates out of distribution on every RCA case, and the centerline geometry distribution is shifted, so the learned positional bias and the centerline-anchor tokens are both extrapolating. The failure is not one of calibration, and per-territory conditioning does not repair it (Table E.5): normalizing positions and radius with RCA statistics roughly halves the pooled pressure error, from 15.7 to 7.0, normalizing Q with RCA statistics as well makes it worse, to 22.5, and in every variant the single global scale factor minimizing the error is indistinguishable from zero, so the pooled correlation between predicted and reference pressure is +0.02 to +0.06 and the zero-shot output is uncorrelated with the right field, a representational failure under extrapolation. Training in the non-dimensional variables of Eq. (7) remains untested and is the one remaining candidate we consider promising. A fresh CARS instance trained from scratch on the RCA split with identical configuration reaches 0.063/0.119 and, on the FFR endpoint, Pearson , MAE 0.008 and threshold accuracy 96.2% (sensitivity 93.5%, specificity 97.5%) on the physiologic-range subset; field errors, r and MAE improve on the LCA result under matched architecture, which we attribute to the simpler topology of the right coronary tree, while threshold accuracy and specificity do not (96.2% against 97.6%, 97.5% against 98.7%), and inference cost is indistinguishable between territories. The RCA cohort therefore evidences within-distribution generalization and not cross-territory transfer; the centerline carries no territory label, so a single checkpoint cannot separate the two regimes without cross-territory training or an explicit territory token.
6. Discussion
6.1. Structure of the endpoint error
Where the endpoint disagrees with the reference, the disagreement is a sign change in the threshold comparison and not a large field error. CARS produces 7/286 discordant cases on LCA (3 FP, 4 FN) and 11/293 on RCA (5 FP, 6 FN) on the physiologic-range subset, and the majority lie within of the FFR = 0.8 level, where the functional of Eq. (29) is most sensitive to a small error in the pressure at the measurement point. On an LCA false positive (Figure 7) the predicted pressure is too low along the entire vessel by a spatially near-uniform amount: a global offset in the operating point, not a focal geometric miss, which the ratio converts into a threshold crossing, and the error mode the ordering of §5.4.2 is best placed to flag. The construction separates by field: pressure is accurate, stable under thinning of the focal and anchor sets, insensitive to evaluation density and good enough to carry the derived decision, whereas velocity degrades far faster under anchor thinning (+50% against +7% relative at eightfold thinning), an order of magnitude faster under reduced precision, and does not satisfy continuity closely enough to differentiate. That asymmetry determines which quantities the surrogate can be used for.
6.2. Position of the surrogate in the end-to-end cost
The arguments of Eq. (9) are themselves the output of an upstream segmentation and centerline-extraction step, and evaluating Eq. (29) addi-
CFD FFR = 0.81 CARS FFR = 0.75

Figure 7: Field-level structure of a discordant case: an LCA false positive (CFD FFR = 0.808, CARS 0.75, case pressure error 0.20), whose reference value sits 0.008 from the decision threshold. Panels and color scales as in Figure 3. The whole predicted pressure field is displaced to a lower level, visible as a uniformly green CARS panel against a uniformly yellow CFD panel and an error panel that is blue almost everywhere; the shape of the field is right and its level is offset, so the ratio of Eq. (29) crosses the threshold without any localized geometric miss.
tionally requires the geometric lesion-localization step of Appendix D. Those steps cost seconds to minutes per case, against 87 ms for the forward pass, so the end-to-end time from a new image is dominated by the geometry pipeline; what Table 4 reports is a speed-up of the flow solution, the stage this work replaces, by a factor of about 6,600 to 12,000 in wall-clock on different hardware classes. The evaluation set used for every number here is the set of cell centers of the reference mesh, so obtaining the points at which the field is reported still requires a volume mesh; points sampled from (c, r) through Eq. (13) would serve, but that changes the inference-time point distribution from the one the model was trained on, and we have not measured the effect. CARS replaces the solve on a given mesh, not the meshing. The ~1 hour figure in circulation is a literature estimate for a full CT-to-FFR pipeline including segmentation and meshing, so dividing it by a forward pass compares two different quantities and inflates the ratio by roughly an order of magnitude.
6.3. Limitations
Table 1 states what the evidence does and does not establish; the limitations below name what would remove each, and further ones (the convergence filter preceding the splits, developing flow over much of the tree, the geometric component of the reference error, non-physiological corners of the product set, the outcome-adjacent endpoint subset, a single acquisition source, RoPE3D under length extrapolation, and smooth-only perturbations) are tabulated with their remedies in Appendix G.
The target is the solver, not the patient. Every error measures agreement with a steady, laminar, rigid-wall, Newtonian OpenFOAM pipeline with prescribed flow-split outlets (Appendix F). What the surrogate captures is therefore the bulk laminar pressure drop along the vessel, the focal loss across stenoses driven by lumen narrowing, the post-stenotic pressure recovery, and the scaling built into the conditioning; pulsatile and transient effects, transitional jets distal to severe stenoses, compliance and microvascular resistance are outside the supervision, and wall shear stress [52] is computable post hoc but is not a supervised output. The AUC of any emulator of this pipeline against invasive FFR is bounded by the pipeline's own, which the prior ML-CT-FFR literature places in the band [11, 44, 42, 45]; closing that gap is a calibration step against a paired invasive cohort.
The reported errors are parameter-space results. The partition is over samples of , applied identically to every model, so the comparisons are unaffected; what it bounds is the absolute figures, which quantify interpolation over the sampled parameter set (G1) and not transfer to unseen anatomies (G2) or acquisition settings (G3). Trajectories recur across splits, and a minority of test cases coincide with a training case in both trajectory and radius profile, differing only in Q ( ). An anatomy-disjoint re-partition of the same LCA cases (Appendix E.1) degrades both CARS and AB-UPT sharply; CARS is the more accurate on both fields and on the large majority of the eleven test anatomies, and the patient-clustered interval spans a factor of two, so resolving the absolute level is a data-collection problem.
The lumens are tubular by construction. Because is injective on this cohort ( ), the experiments compare encodings of a fixed geometric content and cannot say how much geometry a surrogate of this map needs; on independently segmented anatomy the fiber spread of Eq. (12) becomes a genuine error floor, unmeasured here. The same construction fixes the lesion family:
every stenosis is a radial deformation of the radius profile, so trans-lesional loss is driven by caliber and not by plaque morphology.
The frame is part of the input, and terminal fluxes are prescribed. Nothing in the architecture is invariant under a rigid motion of the inputs ( 5.5.2), so inputs must arrive in approximately the frame of the training cohort, a constraint invisible within a single-center cohort; building the equivariance in is the direction a deployment would take. Because every outlet flux is fixed by Eq. (6), a lesion cannot divert flow into a parallel branch, so in these labels the pressure drop grows with severity without the flow reduction FFR exists to probe, a severity-dependent bias not confined to a tail at a median LCA severity of 0.46, and the closed-form split makes the map easier than the physical one; a resistance-outlet re-solve on a severity-spanning subset would quantify the label shift.
The baseline comparison is not fully matched. Five asymmetries, recorded in Appendix C, limit it: the baselines were trained at CARS's optimizer settings; the conditioning pathway differs across arms, priced at 0.024 on pressure by this paper's own ablation; AB-UPT's parameter match is nominal because its surface heads carry zero loss weight; AB-UPT encodes the same geometry more coarsely; and AB-UPT trains in mixed precision. Initialization is not among them.
6.4. Extensions
At the level of the construction, what is presented is an input contract for PDE surrogates on branching or tubular domains carrying a natural low-dimensional skeleton: a skeleton with a caliber profile extractable by a deterministic pre-processing step, and a solution whose dependence on the geometry is dominated by transport along it. That is scope and not demonstrated reach, since the one transfer experiment reported here is negative: airway trees, duct networks, fractured media and heat-exchanger manifolds meet the contract, and each would need its own reference data and training run. Four experiments follow directly from what this paper measures. Objective alignment: the loss weights velocity three to one against the primary pressure endpoint (Appendix A), and a sweep over that weight would establish whether the reported pressure accuracy is limited by the architecture or by the objective. Positional-encoding control: a scale-matched RoPE3D run would separate the encoding choice from the frequency-scale choice ( 3.3.1). Focal-set identification: the experiment of 5.2, which varies only where the focal points sit, would establish whether provenance itself explains the margin. External validation: an independent multi-site CTA and CFD cohort with an anatomy-disjoint partition at a scale that resolves it, together with post-hoc calibration against invasive wire-based FFR, is what would carry the method towards use; both require only centerlines with radius profiles and a flow rate. Extensions to transient and pulsatile supervision, compliant walls, non-Newtonian rheology and physics-constrained training each require new reference data and not a change to the construction.
7. Conclusion
CARS is a two-stage anchored-attention surrogate for the parametric steady incompressible Navier–Stokes problem on centerline-derived coronary lumens. It takes a centerline with a per-point lumen radius and a scalar inlet flow rate, accepts the evaluation points as an argument, and returns pressure and velocity in 87 ms per case. On identical splits and at parameter counts matched to within 3% it is the most accurate of the configurations compared here, ahead of four neural-operator baselines and of the alternative focal representations, and the FFR functional read off its predicted pressure field reproduces the reference solver's decision in 97.7% (LCA) and 96.3% (RCA) of held-out cases. The results support a geometry-defined focal set for this class of surrogate: the margin is neither a density effect nor a parameter-count effect, though the ablations do not isolate the provenance of the focal set from the geometric information its tokens carry. The same building blocks, anchor attention over a geometry-defined focal set, attention-level geometric positional encoding, and multiplicative conditioning on a scalar boundary variable, apply to any problem meeting the input contract of §6.4, of which airway trees, branching pipe networks, channelized porous media and tube bundles are candidate instances; coronary flow is the only one evaluated here, and the cross-territory result shows that meeting the contract does not guarantee transfer across cohorts. Two extensions carry the surrogate toward clinical use: post-hoc calibration of the CFD reference against invasive wire-based FFR, and expansion of the geometry distribution across scanner vendors, acquisition protocols and patient subgroups beyond a single institution.
CRediT authorship contribution statement
Reza Akbarian Bafghi: Conceptualization, Methodology, Software, Formal analysis, Investigation, Validation, Writing – original draft, Visualization. Sukirt Thakur: Conceptualization, Methodology, Software, Data curation, Formal analysis, Investigation, Validation, Writing – original draft,
Visualization. Maziar Raissi: Conceptualization, Methodology, Writing – review & editing, Supervision, Project administration.
Reza Akbarian Bafghi and Sukirt Thakur contributed equally.
Declaration of competing interest
S.T. is employed by AngloInsight, Inc., a company active in coronary hemodynamics. The authors declare no other competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. No invasive measurement, patient-identifiable data or proprietary clinical pipeline enters this work.
Funding
This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Data availability
The coronary CT-angiography volumes underlying this work are publicly available as part of the ImageCAS release [50]. The CFD-derived fields used as supervisory targets were generated from them by the OpenFOAM pipeline of Appendix F, whose mesher draws each stenosis without a recorded seed, so the cases cannot be regenerated exactly from the source volumes (Appendix F.1). The derived dataset, trained models and code are not publicly available.
Declaration of generative AI and AI-assisted technologies in the manuscript preparation process
During the preparation of this work the authors used AI to assist with editing the text and the code. After using this tool, the authors reviewed and edited the content as needed and take full responsibility for the content of the published article.
References
[1] P. A. L. Tonino, B. De Bruyne, N. H. J. Pijls, U. Siebert, F. Ikeno, M. van't Veer, V. Klauss, G. Manoharan, T. Engström, K. G. Oldroyd, P. N. Ver Lee, P. A. MacCarthy, W. F. Fearon, Fractional flow reserve versus angiography for guiding percutaneous coronary intervention, New England Journal of Medicine 360 (3) (2009) 213–224. doi:10.1056/NEJMoa0807611.
[2] World Health Organization, Cardiovascular diseases (CVDs) – WHO fact sheet, https://www.who.int/news-room/fact-sheets/detail/cardiovascular-diseases-(cvds), fact sheet updated 31 July 2025; accessed 11 August 2026 (2025).
[3] C. A. Taylor, T. A. Fonte, J. K. Min, Computational fluid dynamics applied to cardiac computed tomography for noninvasive quantification of fractional flow reserve, Journal of the American College of Cardiology 61 (22) (2013) 2233–2241. doi:10.1016/j.jacc.2012.11.083.
[4] B. L. Nørgaard, J. Leipsic, S. Gaur, S. Seneviratne, B. S. Ko, H. Ito, J. M. Jensen, L. Mauri, B. De Bruyne, H. Bezerra, K. Osawa, M. Marwan, C. Naber, A. Erglis, S. J. Park, E. H. Christiansen, A. Kaltoft, J. F. Lassen, H. E. Bøtker, S. Achenbach, Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in suspected coronary artery disease, Journal of the American College of Cardiology 63 (12) (2014) 1145–1155. doi:10.1016/j.jacc.2013.11.043.
[5] J. Su, M. Ahmed, Y. Lu, S. Pan, B. Wen, Y. Liu, Roformer: Enhanced transformer with rotary position embedding, Neurocomputing 568 (2024) 127063. doi:10.1016/j.neucom.2023.127063.
[6] J. Lee, Y. Lee, J. Kim, A. Kosiorek, S. Choi, Y. W. Teh, Set transformer: A framework for attention-based permutation-invariant neural networks, in: International Conference on Machine Learning (ICML), 2019, pp. 3744–3753. arXiv:1810.00825.
[7] B. Alkin, M. Bleeker, R. Kurle, T. Kronlachner, R. Sonnleitner, M. Dorfer, J. Brandstetter, AB-UPT: Scaling neural CFD surrogates for high-fidelity automotive aerodynamics simulations via anchored-branched universal physics transformers, Transactions on Machine Learning Research (2025). arXiv:2502.09692.
[8] R. Akbarian Bafghi, S. Thakur, M. Raissi, From centerlines to hemodynamics: Anisotropic RBF decoders for coronary arteries, Transactions on Machine Learning Research (2026). URL https://openreview.net/forum?id=AoJUrVjufP
[9] B. K. Koo, A. Erglis, J. H. Doh, D. V. Daniels, S. Jegere, H. S. Kim, A. Dunning, T. DeFrance, A. Lansky, J. Leipsic, J. K. Min, Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms, Journal of the American College of Cardiology 58 (19) (2011) 1989–1997. doi:10.1016/j.jacc.2011.06.066.
[10] J. K. Min, J. Leipsic, M. J. Pencina, D. S. Berman, B. K. Koo, C. van Mieghem, A. Erglis, F. Y. Lin, A. M. Dunning, P. Apruzzese, M. J. Budoff, J. H. Cole, F. A. Jaffer, M. B. Leon, J. Malpeso, G. B. Mancini, S. J. Park, R. S. Schwartz, L. J. Shaw, L. Mauri, Diagnostic accuracy of fractional flow reserve from anatomic CT angiography, Journal of the American Medical Association 308 (12) (2012) 1237–1245. doi:10.1001/2012.JAMA.11274.
[11] L. Itu, S. Rapaka, T. Passerini, B. Georgescu, C. Schwemmer, M. Schoebinger, T. Flohr, P. Sharma, D. Comaniciu, A machine-learning approach for computation of fractional flow reserve from coronary computed tomography, Journal of Applied Physiology 121 (1) (2016) 42–52. doi:10.1152/japplphysiol.00752.2015.
[12] P. Benner, S. Gugercin, K. Willcox, A survey of projection-based model reduction methods for parametric dynamical systems, SIAM Review 57 (4) (2015) 483–531. doi:10.1137/130932715.
[13] M. Barrault, Y. Maday, N. C. Nguyen, A. T. Patera, An ‘empirical interpolation’ method: application to efficient reduced-basis discretization of partial differential equations, Comptes Rendus Mathématique 339 (9) (2004) 667–672. doi:10.1016/j.crma.2004.08.006.
[14] T. Lassila, G. Rozza, Parametric free-form shape design with pde models and reduced basis method, Computer Methods in Applied Mechanics and Engineering 199 (23–24) (2010) 1583–1592. doi:10.1016/j.cma.2010.01.007.
[15] F. Ballarin, E. Faggiano, S. Ippolito, A. Manzoni, A. Quarteroni, G. Rozza, R. Scrofani, Fast simulations of patient-specific haemodynamics of coronary artery bypass grafts based on a POD–Galerkin method and a vascular shape parametrization, Journal of Computational Physics 315 (2016) 609–628. doi:10.1016/j.jcp.2016.03.065.
[16] A. Quarteroni, A. Manzoni, C. Vergara, The cardiovascular system: Mathematical modelling, numerical algorithms and clinical applications, Acta Numerica 26 (2017) 365–590. doi:10.1017/S0962492917000046.
[17] I. E. Vignon-Clementel, C. A. Figueroa, K. E. Jansen, C. A. Taylor, Outflow boundary conditions for three-dimensional finite element modeling of blood flow and pressure in arteries, Computer Methods in Applied Mechanics and Engineering 195 (29–32) (2006) 3776–3796. doi:10.1016/j.cma.2005.04.014.
[18] X. Guo, W. Li, F. Iorio, Convolutional neural networks for steady flow approximation, in: Proceedings of the 22nd ACM SIGKDD International Conference on Knowledge Discovery and Data Mining, 2016, pp. 481–490. doi:10.1145/2939672.2939738.
[19] N. Thuerey, K. Weißenow, L. Prantl, X. Hu, Deep learning methods for reynolds-averaged Navier–Stokes simulations of airfoil flows, AIAA Journal 58 (1) (2020) 25–36. doi:10.2514/1.j058291.
[20] C. M. Jiang, S. Esmaeilzadeh, K. Azizzadenesheli, K. Kashinath, M. Mustafa, H. A. Tchelepi, P. Marcus, M. Prabhat, A. Anandkumar, Meshfreeflownet: A physics-constrained deep continuous space-time super-resolution framework, in: SC20: International Conference for High Performance Computing, Networking, Storage and Analysis, 2020, pp. 1–15. doi:10.1109/SC41405.2020.00013.
[21] R. Gharleghi, A. Sowmya, S. Beier, Transient wall shear stress estimation in coronary bifurcations using convolutional neural networks, Computer Methods and Programs in Biomedicine 225 (2022) 107013. doi:10.1016/j.cmpb.2022.107013.
[22] T. Pfaff, M. Fortunato, A. Sanchez-Gonzalez, P. W. Battaglia, Learning mesh-based simulation with graph networks, in: International Conference on Learning Representations (ICLR), 2021. arXiv:2010.03409.
[23] J. Suk, P. de Haan, P. Lippe, C. Brune, J. M. Wolterink, Mesh neural networks for SE(3)-equivariant hemodynamics estimation on the artery wall, Computers in Biology and Medicine 173 (2024) 108328. doi:10.1016/j.compbiomed.2024.108328.
[24] G. Nannini, J. Suk, P. Rygiel, S. Saitta, L. Mariani, R. Maranga, A. Baggiano, G. Pontone, J. M. Wolterink, A. Redaelli, Learning hemodynamic scalar fields on coronary artery meshes: A benchmark of geometric deep learning models, Computers in Biology and Medicine 195 (2025) 110477. doi:10.1016/j.compbiomed.2025.110477.
[25] L. Lu, P. Jin, G. Pang, Z. Zhang, G. E. Karniadakis, Learning nonlinear operators via DeepONet based on the universal approximation theorem of operators, Nature Machine Intelligence 3 (2021) 218–229. doi:10.1038/s42256-021-00302-5.
[26] Z. Li, N. Kovachki, K. Azizzadenesheli, B. Liu, K. Bhattacharya, A. Stuart, A. Anandkumar, Fourier neural operator for parametric partial differential equations, in: International Conference on Learning Representations (ICLR), 2021. arXiv:2010.08895.
[27] Z. Li, D. Z. Huang, B. Liu, A. Anandkumar, Fourier neural operator with learned deformations for PDEs on general geometries, Journal of Machine Learning Research 24 (388) (2023) 1–26. arXiv:2207.05209.
[28] M. Raissi, P. Perdikaris, G. E. Karniadakis, Physics-informed neural networks: A deep learning framework for solving forward and inverse problems involving nonlinear partial differential equations, Journal of Computational Physics 378 (2019) 686–707. doi:10.1016/j.jcp.2018.10.045.
[29] Z. Chen, Y. Liu, H. Sun, Physics-informed learning of governing equations from scarce data, Nature Communications 12 (2021) 6136. doi:10.1038/s41467-021-26434-1.
[30] M. Penwarden, S. Zhe, A. Narayan, R. M. Kirby, A metalearning approach for physics-informed neural networks (PINNs): Application to parameterized PDEs, Journal of Computational Physics 477 (2023) 111912. doi:10.1016/j.jcp.2023.111912.
[31] A. Vaswani, N. Shazeer, N. Parmar, J. Uszkoreit, L. Jones, A. N. Gomez, Ł. Kaiser, I. Polosukhin, Attention is all you need, in: Advances in Neural Information Processing Systems (NeurIPS), 2017. arXiv:1706.03762.
[32] A. Dosovitskiy, L. Beyer, A. Kolesnikov, D. Weissenborn, X. Zhai, T. Unterthiner, M. Dehghani, M. Minderer, G. Heigold, S. Gelly, J. Uszkoreit, N. Houlsby, An image is worth words: Transformers for image recognition at scale, in: International Conference on Learning Representations (ICLR), 2021. arXiv:2010.11929.
[33] Z. Liu, Y. Lin, Y. Cao, H. Hu, Y. Wei, Z. Zhang, S. Lin, B. Guo, Swin transformer: Hierarchical vision transformer using shifted windows, in: ICCV, 2021, pp. 10012–10022. doi:10.1109/iccv48922.2021.00986.
[34] H. Zhao, L. Jiang, J. Jia, P. H. S. Torr, V. Koltun, Point transformer, in: ICCV, 2021, pp. 16239–16248. doi:10.1109/ICCV48922.2021.01595.
[35] N. Kovachki, Z. Li, B. Liu, K. Azizzadenesheli, K. Bhattacharya, A. Stuart, A. Anandkumar, Neural operator: Learning maps between function spaces, Journal of Machine Learning Research 24 (89) (2023) 1–97. arXiv:2108.08481.
[36] A. Jaegle, S. Borgeaud, J. B. Alayrac, C. Doersch, C. Ionescu, D. Ding, S. Koppula, D. Zoran, A. Brock, E. Shelhamer, et al., Perceiver IO: A general architecture for structured inputs and outputs, in: ICLR, 2022. arXiv:2107.14795.
[37] Z. Xiao, Z. Hao, B. Lin, Z. Deng, H. Su, Improved operator learning by orthogonal attention, in: International Conference on Machine Learning (ICML), 2024, pp. 54288–54299. doi:10.48550/arXiv.2310.12487.
[38] H. Wu, H. Luo, H. Wang, J. Wang, M. Long, Transolver: A fast transformer solver for PDEs on general geometries, in: International Conference on Machine Learning (ICML), 2024. doi:10.48550/arXiv.2402.02366.
[39] Z. Hao, Z. Wang, H. Su, C. Ying, Y. Dong, S. Liu, Z. Cheng, J. Song, J. Zhu, GNOT: A general neural operator transformer for operator learning, in: International Conference on Machine Learning (ICML), 2023, pp. 12556–12569. doi:10.48550/arXiv.2302.14376.
[40] Z. Li, N. Kovachki, C. Choy, B. Li, J. Kossaifi, S. Otta, M. A. Nabian, M. Stadler, C. Hundt, K. Azizzadenesheli, A. Anandkumar, Geometry-informed neural operator for large-scale 3D PDEs, in: Advances in Neural Information Processing Systems (NeurIPS), 2023. doi:10.52202/075280-1556.
[41] B. Mildenhall, P. P. Srinivasan, M. Tancik, J. T. Barron, R. Ramamoorthi, R. Ng, Nerf: Representing scenes as neural radiance fields for view synthesis, in: ECCV, 2020. doi:10.1007/978-3-030-58452-8_24.
[42] C. Tesche, C. N. De Cecco, S. Baumann, M. Renker, T. W. McLaurin, T. M. Duguay, R. R. Bayer, D. H. Steinberg, K. L. Grant, C. Canstein, M. Schoebinger, L. M. Itu, S. Rapaka, P. Sharma, U. J. Schoepf, Coronary CT angiography-derived fractional flow reserve: machine learning algorithm versus computational fluid dynamics modeling, Radiology 288 (1) (2018) 64–72. doi:10.1148/radiol.2018171291.
[43] M. Renker, U. J. Schoepf, R. Wang, F. G. Meinel, J. D. Rier, R. R. Bayer, H. Möllmann, C. W. Hamm, D. H. Steinberg, S. Baumann, Comparison of diagnostic value of a novel noninvasive coronary computed tomography angiography method versus standard coronary angiography for assessing fractional flow reserve, American Journal of Cardiology 114 (9) (2014) 1303–1308. doi:10.1016/j.amjcard.2014.07.064.
[44] A. Coenen, Y. H. Kim, M. Kruk, C. Tesche, J. De Geer, A. Kurata, M. L. Lubbers, J. Daemen, L. Itu, S. Rapaka, P. Sharma, C. Schwemmer, A. Persson, U. J. Schoepf, C. Kepka, D. H. Yang, K. Nieman, Diagnostic accuracy of a machine-learning approach to coronary computed tomographic angiography-based fractional flow reserve: result from the machine consortium, Circulation: Cardiovascular Imaging 11 (6) (2018) e007217. doi:10.1161/CIRCIMAGING.117.007217.
[45] K. K. Kumamaru, S. Fujimoto, Y. Otsuka, T. Kawasaki, Y. Kawaguchi, E. Kato, K. Takamura, C. Aoshima, Y. Kamo, Y. Kogure, H. Inage, H. Daida, S. Aoki, Diagnostic accuracy of 3d deep-learning-based fully automated estimation of patient-level minimum fractional flow reserve from coronary computed tomography angiography, European Heart Journal – Cardiovascular Imaging 21 (4) (2020) 437–445. doi:10.1093/ehjci/jez160.
[46] C. D. Murray, The physiological principle of minimum work: I. the vascular system and the cost of blood volume, Proceedings of the National Academy of Sciences 12 (3) (1926) 207–214. doi:10.1073/PNAS.12.3.207.
[47] M. Decroocq, C. Frindel, P. Rougé, M. Ohta, G. Lavoué, Modeling and hexahedral meshing of cerebral arterial networks from centerlines, Medical Image Analysis 89 (2023) 102912. doi:10.1016/j.media.2023.102912.
[48] R. Xiong, Y. Yang, D. He, K. Zheng, S. Zheng, C. Xing, H. Zhang, Y. Lan, L. Wang, T.-Y. Liu, On layer normalization in the trans-former architecture, in: International Conference on Machine Learning (ICML), 2020, pp. 10524–10533. arXiv:2002.04745.
[49] E. Perez, F. Strub, H. de Vries, V. Dumoulin, A. Courville, FiLM: Visual reasoning with a general conditioning layer, in: AAAI Conference on Artificial Intelligence, 2018. doi:10.1609/aaai.v32i1.11671.
[50] A. Zeng, C. Wu, G. Lin, W. Xie, J. Hong, M. Huang, J. Zhuang, S. Bi, D. Pan, N. Ullah, et al., Imagecas: A large-scale dataset and benchmark for coronary artery segmentation based on computed tomography angiography images, Computerized Medical Imaging and Graphics 109 (2023) 102287. doi:10.1016/j.compmedimag.2023.102287.
[51] I. Loshchilov, F. Hutter, Decoupled weight decay regularization, in: International Conference on Learning Representations (ICLR), 2019. arXiv:1711.05101.
[52] P. H. Stone, S. Saito, S. Takahashi, Y. Makita, S. Nakamura, T. Kawasaki, A. Takahashi, T. Katsuki, S. Nakamura, A. Namiki, A. Hirohata, T. Matsumura, S. Yamazaki, H. Yokoi, S. Tanaka, S. Otsuji, F. Yoshimachi, J. Honye, D. Harwood, M. Reitman, A. U. Coskun, M. I. Papafaklis, C. L. Feldman, Prediction of progression of coronary artery disease and clinical outcomes using vascular profiling of endothelial shear stress and arterial plaque characteristics: the PRE-DICTION study, Circulation 126 (2) (2012) 172–181. doi:10.1161/circulationaha.112.096438.
[53] H. G. Weller, G. Tabor, H. Jasak, C. Fureby, A tensorial approach to computational continuum mechanics using object-oriented techniques, Computers in Physics 12 (6) (1998) 620–631. doi:10.1063/1.168744.
[54] J. E. Davies, S. Sen, H. M. Dehbi, R. Al-Lamee, R. Petraco, S. Nijjer, R. Bhindi, S. J. Lehman, D. Walters, J. Sapontis, L. Janssens, et al., Use of the instantaneous wave-free ratio or fractional flow reserve in PCI, New England Journal of Medicine 376 (19) (2017) 1824–1834. doi:10.1056/NEJMoa1700445.
[55] C. M. Cook, A. Jeremias, R. Petraco, S. Sen, S. Nijjer, M. J. Shun-Shin, Y. Ahmad, G. de Waard, T. van de Hoef, M. Echavarria-Pinto, M. van Lavieren, R. Al Lamee, Y. Kikuta, Y. Shiono, A. Buch, M. Meuwissen, I. Danad, P. Knaapen, A. Maehara, B. K. Koo, G. S. Mintz, J. Escaned, G. W. Stone, D. P. Francis, J. Mayet, J. J. Piek, N. van
Royen, J. E. Davies, Fractional flow reserve/instantaneous wave-free ratio discordance in angiographically intermediate coronary stenoses, JACC: Cardiovascular Interventions 10 (24) (2017) 2514–2524. doi:10.1016/j.jcin.2017.09.021.
[56] P. J. Roache, Perspective: A method for uniform reporting of grid refinement studies, Journal of Fluids Engineering 116 (3) (1994) 405–413. doi:10.1115/1.2910291.
[57] P. J. Roache, Quantification of uncertainty in computational fluid dynamics, Annual Review of Fluid Mechanics 29 (1997) 123–160. doi:10.1146/ANNUREV.FLUID.29.1.123.
[58] I. B. Celik, U. Ghia, P. J. Roache, C. J. Freitas, H. Coleman, P. E. Raad, Procedure for estimation and reporting of uncertainty due to discretization in cfd applications, Journal of Fluids Engineering 130 (7) (2008) 078001. doi:10.1115/1.2960953.
Appendix A. Training and architecture details
Appendix A.1. Architecture hyperparameters
Table A.1 lists the defaults used throughout.
Table A.1: Default CARS model hyperparameters used in all reported experiments unless otherwise stated.
| Parameter | Value |
|---|---|
| 192 | |
| Attention heads | 3 |
| FFN expansion ratio | 4 |
| Geometry-fusion blocks | 4 |
| Field-refinement blocks | 4 |
| Sinusoidal position dim | 192 |
| Centerline tokens | 2,048 |
| Volume tokens | 16,384 |
| Stage-2 volume anchors | 16,384 |
| Stage-2 pure query points | 0 |
| Dropout | 0.1 |
| Output channels | 4 (1 pressure + 3 velocity) |
Appendix A.2. Loss and optimization
The training loss is the mean squared error between predicted and ground-truth pressure and velocity components in normalized space, . Pressure contributes one term and velocity three, and all four targets are z-scored, so the effective weighting is 1:3 in favor of velocity although pressure is the primary endpoint. The pressure errors reported here are therefore what the architecture achieves despite an objective tilted towards velocity, and the pressure–velocity trade-offs visible in the fixed-anchor sweep and the bfloat16 comparison may be partly an artifact of this weighting; a sweep over the relative weight needs retraining and has not been run.
Optimization uses AdamW [51] with learning rate , , weight decay , and ; cosine annealing with linear warm-up over the first of steps, decaying to ; gradient clipping at global norm 1.0; dropout 0.1; and an exponential moving average of parameters with decay for validation and inference. Training runs at batch size 1 for 100 epochs in ablation studies and 300 epochs in full runs, because larger batches destabilized optimization in this AdamW setup. We record batch size 1 as an unresolved optimization pathology: the learning rate was tuned at batch size 1 and not jointly with it, so the instability may be an artifact of holding fixed while the effective noise scale changed, and the finding that training length is the most effective lever per unit compute may partly reflect a slow optimizer setting. Every CARS run trains in fp32, and inference, including the reported 87 ms latency, is fp32 except for the 15 ms bfloat16 operating point quoted as such. Checkpoints are saved every 10 epochs.
Appendix A.3. Computational complexity, analytic and measured
For centerline tokens, evaluation points and Stage-2 anchors, the forward cost of the two stages of §3.6 is
where counts all evaluation points, the anchors included, whereas the centerline tokens of Stage 1 are disjoint from the evaluation tokens. The expression is linear in only when both and are held fixed as grows. At the configuration behind every accuracy number in this paper , so the middle term is and Stage 2 is full self-attention; the accuracy cost of entering the linear regime is Table A.3. Stage 1 is quadratic in the centerline count, which is harmless because is small and well past the point where accuracy stops improving.
Wall-clock is the median of 15 timed forward passes after 5 warmup passes on an idle A100 80GB PCIe in fp32; peak memory is max_memory_allocated around a single pass. Table A.2 reports fitted log-log slopes over three regimes. Holding the evaluation set at 16,384 points and varying the focal count over 256–4,096 changes cost by less than 25% (slope 0.07 in time), so within this range the position-wise feed-forward work dominates. Holding the Stage-2 anchor set at 2,048 and adding query points, cost grows close to linearly (overall slope 0.66, local slope 0.90 over 32,768 → 65,536), which is the regime the complexity claim describes. If instead every evaluation point is also an anchor, the cost approaches quadratic (slope 1.27, rising to 1.70 over 16,384 → 32,768, against 1.81 for a standard self-attention layer of the same width over the same token count); the density sweep of Table 5 traverses this regime. Peak-memory slopes are less informative (0.64 tiered, 0.72 reference) because the reference uses a memory-efficient attention implementation. No approximation bound in is derived here; an
Table A.2: Measured scaling on an idle A100 80GB PCIe, fp32. Slopes are fitted to against over the stated range. The claim is a slope of 1 for the tiered model and 2 for global self-attention. n/a: not measured.
| Swept quantity | Range | Time slope | Memory slope |
|---|---|---|---|
| Focal (centerline) tokens, N fixed | 256–4,096 | 0.07 | 0.05 |
| Evaluation points, anchors fixed | 2,048–65,536 | 0.66 | n/a |
| upper half of that range | 32,768–65,536 | 0.90 | n/a |
| Evaluation points, all as anchors | 2,048–32,768 | 1.27 | 0.64 |
| upper half of that range | 16,384–32,768 | 1.70 | n/a |
| Global self-attention (reference) | 3,072–67,584 | 1.81 | 0.72 |
Table A.3: Accuracy in the fixed-anchor regime, LCA, 300-case test split, fp32, mean relative over cases. Trained weights unchanged; the total evaluation budget is held at 16,384 points, the anchor count is reduced and the remaining points are supplied as pure Stage-2 query points, with the error scored on those query points only. The Stage-2 attention matrix is , so its cost relative to the operating point is . The last row is a separate model trained from scratch with the anchor set fixed at 2,048; both it and the thinned flagship run at a measured median 22.5 ms against the operating point's 87 ms.
| Query points | Stage-2 cost | Pressure | Velocity | |
|---|---|---|---|---|
| 1,024 | 15,360 | 0.063× | 0.138 | 0.311 |
| 2,048 | 14,336 | 0.125× | 0.125 | 0.220 |
| 4,096 | 12,288 | 0.25× | 0.121 | 0.174 |
| 8,192 | 8,192 | 0.50× | 0.117 | 0.154 |
| 16,384 (operating point) | 0 | 1× | 0.117 | 0.147 |
| trained in the linear regime, 300 epochs, same architecture and data | ||||
| 2,048 | 14,336 | 0.125× | 0.141 | 0.202 |
interpolation-error estimate in terms of focal arc-length spacing, with the straight-tube Poiseuille case as the tractable instance, is the missing analysis.
Appendix A.4. 3D rotary position embeddings
RoPE rotates query and key vectors so that, for the rotated , , the dot product depends only on the relative position [5]. We extend this to 3D by partitioning each attention head's rotation pairs across the three axes as evenly as the head width allows, and applying a 2D rotation per axis. Writing for the number of pairs assigned to axis , so that , define for each axis and pair index the rotation angle and the block-diagonal rotation matrix
Writing the head as its three axis blocks, and analogously for , the rotated query is
and analogously for . The resulting attention score depends only on the coordinate displacement , componentwise in each axis, and so encodes 3D Euclidean proximity directly. RoPE3D adds no learnable parameters and negligible computation.
The frequency ladder is inherited, and it is not adapted to this coordinate range. The base in is the language-model default, where positions are token indices running to or beyond. Here coordinates are normalized to ( ), so the angle in the highest-frequency pair reaches at most 1 radian across the entire domain, which is 0.16 of a cycle, and the ladder falls from there: with and eleven pairs on the first axis, the per-pair maximum angles are 1, 0.43, 0.19, 0.08, 0.035, and below 0.016 for the remaining six. Nine of the eleven rotations are therefore small-angle over the whole coronary tree, and RoPE3D as configured is close to the identity in most of its channels. The same applies to the input-stage sinusoidal embedding, where 75% of channels traverse less than 0.1 radian and 47% less than 0.01 across the domain, so those channels supply a scaled linear ramp and a constant rather than an oscillation. The learned alternative of is an unconstrained MLP of the coordinate and can realize whatever length scale the problem wants, while the rotary arm is pinned to a wavelength ladder chosen for a different kind of input. The margin measured between them therefore confounds the form of the encoding with the choice of frequency scale: a learned encoding beats this configuration of RoPE3D rather than rotary encoding as such. Rescaling the base so that the shortest wavelength matches the lumen radius, or non-dimensionalizing the coordinates by a characteristic length, is the control that would separate the two; it needs retraining and has not been run.
Appendix A.5. Hyperparameter sweep
Table A.4 varies training length, depth and width one axis at a time from the 100-epoch learned-PE reference.
Table A.4: Single-axis hyperparameter sweep on the learned-PE configuration. The reference row is the 100-epoch learned-PE run of Table 3. Bold rows mark the best pressure and velocity across the sweep. All errors are validation relative ; the corresponding test errors for the 300-epoch row are on pressure / velocity ().
| Axis | Configuration | Params | Val. press. | Val. vel. |
|---|---|---|---|---|
| Reference | 100 ep, d=192, 4+4 blocks | 3,857,284 | 0.140 | 0.196 |
| Epochs | 200 epochs | 3,857,284 | 0.117 | 0.161 |
| 300 epochs | 3,857,284 | 0.108 | 0.141 | |
| Depth | 6+6 blocks | 5,636,740 | 0.126 | 0.173 |
| 8+8 blocks | 7,416,196 | 0.115 | 0.154 | |
| Width | d=256, h=4 | 6,797,572 | 0.140 | 0.187 |
Appendix B. Field accuracy: ablation contracts, seed variance and error distribution
Appendix B.1. What each ablation arm receives
The ablations of Table 3 are described by the component they replace, but two arms change more than that description implies. Table B.1 states the input contract of every arm. All arms receive the volume evaluation points and the scalar flow rate , except where FiLM is removed. The learned-anchor arm replaces the centerline token stream by 512 free parameters and so receives neither the centerline coordinates nor the radius profile, and because the anchors carry no spatial positions the attention-level positional encoding is inactive in Stage 1; that row prices three simultaneous changes, and the pressure delta bounds the joint effect from above and attributes none of it. Isolating the focal-set contribution requires an arm that keeps the centerline and radius as inputs while drawing the focal set from learned inducing points, which has not been run. "Remove FiLM" prices the availability of the flow rate; FiLM Concat prices the form of the conditioning.
Appendix B.2. Reference configuration
The component ablations use RoPE3D as the reference (0.205/0.287 at 100 epochs). The positional-encoding head-to-head is a separate, paired run of CARS-RoPE3D and CARS-learned-PE (identical hyperparameters, fixed seed, a different random-initialization state); its RoPE3D figure is 0.199/0.269. The two RoPE3D numbers index the same configuration in two runs, and the difference is consistent with the run-to-run variability at this batch size. We use 0.205/0.287 for deltas within the component rows
Table B.1: Input contract of each ablation arm. “PE (S1)” is the attention-level positional encoding in Stage 1; it is active in Stage 2 in every arm.
| Arm | CL (x,y,z) | r | Q | PE (S1) | What the row prices |
|---|---|---|---|---|---|
| CARS (default) | yes | yes | yes | yes | (reference) |
| Tiered → Cross-only | yes | yes | yes | yes | focal self-attention |
| Tiered → Perceiver | yes | yes | yes | yes | attention structure |
| FiLM → Concat | yes | yes | yes | yes | form of conditioning |
| Two-stage → Single-stage | yes | yes | yes | yes | staging |
| Remove FiLM | yes | yes | no | yes | availability of Q |
| CL anchors → Learned | no | no | yes | no | focal set, geometric input and Stage-1 PE jointly |
and 0.199/0.269 when quoting CARS-RoPE3D against learned PE and in Table 4; the positional-encoding margin is the paired one, 0.199/0.269 → 0.140/0.196 (30%/27%). Three rows with large RoPE3D deltas (Perceiver, learned anchors, remove FiLM) were not run on the learned-PE backbone; the two small or sign-ambiguous rows (FiLM→Concat, single-stage) were, and both resolve in favor of the CARS defaults (Table 3).
Appendix B.3. Run-to-run variance
Tables report point estimates from one seed per configuration. Re-evaluating the primary 300-epoch model over eight independent draws of the full test set gives a standard deviation of 0.0003 on pressure and 0.0002 on velocity (mean 0.117/0.147), so reported field errors are reproducible to a few parts in and the corresponding band on the threshold-agreement figure is 0.26 percentage points. Retraining the 100-epoch learned-PE configuration from three seeds (42, 43, 44) gives test pressure 0.1497, 0.1538, 0.1544 and velocity 0.1993, 0.2108, 0.2060, i.e. and ; seed 42 rounds to the 0.150/0.199 of Table 4. The two CARS-RoPE3D runs above give a more conservative two-point spread of and . At 300 epochs the three seeds of the primary configuration (Table B.2) give and , so the two-run velocity bound is conservative by roughly a factor of four at that budget. Seed spread is not a constant of the problem: AB-UPT at the same budget spreads by 0.0138 on pressure, four times CARS's figure. Against the conservative bound the architectural effects the paper draws conclusions from are larger by on the relevant field, and against the measured three-seed spread by .
Table B.2: The primary 300-epoch LCA configuration and the AB-UPT baseline, each retrained from the same three seeds and evaluated under one fp32 test protocol on the 300-case test split (best-validation checkpoint, EMA weights for CARS). Seed 42 is the CARS run reported as the single-run figure of Table 4; seed 1234 is the AB-UPT single run and is listed for reference but excluded from the matched statistics, since CARS was not trained at it. Both single-run rows happen to be their arm's best seed, and because AB-UPT is the more variable of the two the single-seed comparison understates the gap.
| Seed | CARS | AB-UPT | ||
|---|---|---|---|---|
| Pressure | Velocity | Pressure | Velocity | |
| 42 | 0.1168 | 0.1473 | 0.1690 | 0.1843 |
| 43 | 0.1232 | 0.1544 | 0.1635 | 0.1686 |
| 44 | 0.1194 | 0.1455 | 0.1428 | 0.1642 |
| mean ± s.d. | ||||
| unmatched, for reference | ||||
| 1234 | n/a | n/a | 0.1300 | 0.1624 |
Appendix B.4. Distribution of the per-case error and focal count
Table B.3 gives the distribution of the per-case error behind the headline means, and Table B.4 the sensitivity of the trained model to the focal density it is queried with.
Table B.3: Distribution of per-case relative error over the 300-case test split of each territory, in the cell-center measure of §4.1. The mean column is the headline figure; the remaining columns are given because the distribution is right-skewed enough that the mean is not a description of a typical case. Computed from the per-case exports underlying §5.5.1, whose means agree with the headline to 0.002.
| Field | Mean | s.d. | Median | p90 | p95 | Worst | |
|---|---|---|---|---|---|---|---|
| LCA | Pressure | 0.117 | 0.138 | 0.065 | 0.288 | 0.432 | 0.950 |
| Velocity | 0.147 | 0.072 | 0.130 | 0.230 | 0.277 | 0.520 | |
| RCA | Pressure | 0.063 | 0.068 | 0.041 | 0.121 | 0.188 | 0.494 |
| Velocity | 0.119 | 0.055 | 0.105 | 0.181 | 0.203 | 0.433 |
Appendix B.5. Field accuracy excluding duplicate geometries
Of the 300 test cases in each territory, 34 (LCA) and 22 (RCA) are identical to a training case in both centerline trajectory and radius profile, differing only in the inlet flow rate (§4.1). Because a surrogate could in principle have memorized those geometries, Table B.5 reports the headline field errors with them removed.
Table B.4: Test accuracy against focal (centerline) count on the 300-case LCA test split, at fixed weights trained with . The focal set is thinned by uniform arc-length stride from the 2,048-point resampled centerline, so the branch decomposition and the axial ordering are preserved and only the focal density changes. Mean and median of the per-case relative error, fp32. This measures how sensitive a trained surrogate is to the focal density it is queried with, not the accuracy attainable if it were retrained at each count.
| Pressure | Velocity | |||
|---|---|---|---|---|
| Mean | Median | Mean | Median | |
| 128 | 0.1328 | 0.0751 | 0.1564 | 0.1390 |
| 256 | 0.1187 | 0.0646 | 0.1489 | 0.1298 |
| 512 | 0.1176 | 0.0642 | 0.1470 | 0.1295 |
| 1,024 | 0.1162 | 0.0632 | 0.1468 | 0.1288 |
| 2,048 (default) | 0.1163 | 0.0631 | 0.1468 | 0.1292 |
Table B.5: Mean relative error on the full test split and with identical duplicate geometries removed. Computed from the same per-case exports as the error-structure analysis.
| Territory | Field | Full split (300) | Duplicates only | Duplicates removed |
|---|---|---|---|---|
| LCA | Pressure | 0.117 | 0.039 (n = 34) | 0.127 (n = 266) |
| Velocity | 0.147 | 0.087 | 0.155 | |
| RCA | Pressure | 0.063 | 0.041 (n = 22) | 0.065 (n = 278) |
| Velocity | 0.119 | 0.073 | 0.122 |
The duplicates are substantially easier than the rest: mean pressure error 0.039 against 0.127 on LCA and 0.041 against 0.065 on RCA. Their effect on the headline is nonetheless small, because they are a minority of the split: removing them raises the reported LCA pressure error by 0.010 and the RCA figure by 0.002. Every conclusion in the paper is unchanged under the duplicate-free numbers, and the model-to-model comparisons are unaffected because the partition is identical for every model.
Appendix C. Neural-operator baselines: configurations
All baselines are matched in parameter count to within 3% of CARS and trained for 100 epochs on the same LCA dataset with identical preprocessing (16,384 volume points, 2,048 centerline points, z-score normalization); Table C.1 summarizes them. Every baseline was trained with AdamW at CARS's settings (learning rate , weight decay 0.05, cosine schedule with 5% warm-up, batch size 1); the AB-UPT single runs used learning rate
Table C.1: Baseline configurations. All are trained on the same splits with the same preprocessing; the first three receive volume positions and centerline conditioning (positions, radii, flow rate), AB-UPT receives the surface mesh and the flow rate.
| Model | Width / blocks | Params | Geometric input | Q pathway |
|---|---|---|---|---|
| GNOT [39] | d=144 | 3.87M | centerline tokens (branch input) | concatenated to trunk |
| ONO [37] | d=276 | 3.84M | centerline tokens | sinusoidal embedding |
| Transolver [38] | d=292 | 3.81M | centerline tokens | sinusoidal embedding |
| AB-UPT [7] | d=132, h=2, 5+5 | 3.76M | surface mesh, 8,192 points pooled to 1,024 supernodes | FiLM (as CARS) |
| CARS | d=192, h=3, 4+4 | 3.86M | centerline (x,y,z,r) | FiLM |
and weight decay 0.01, and its matched-seed runs use CARS's settings. No per-baseline learning-rate or schedule search was performed, and the batch-size-1 regime may specifically disadvantage architectures designed to train at larger batches: the 0.804/0.957 reached by ONO is close to what predicting the training mean would give, the signature of a baseline that has not trained. The margins over GNOT, ONO and Transolver are therefore upper bounds on the architectural difference. The flow rate reaches the baselines by three routes (concatenation, sinusoidal embedding, FiLM), and the ablation of Table 3 prices replacing FiLM by concatenation at 0.024 on both fields, so a quantified share of the gap to the non-FiLM baselines is attributable to conditioning. The AB-UPT comparison, on which the paper's claims rest, trains stably and is compared over three shared seeds.
GNOT. Heterogeneous cross-attention with centerline tokens as branch inputs and mixture-of-experts feed-forward networks with geometric gating.
ONO. Orthogonal neural operator built on orthonormalized neural eigenfunctions of the kernel integral operator, with an orthogonalization-regularized attention block.
Transolver. Physics-informed slice attention projecting tokens onto a small set of learned slices, at linear complexity.
AB-UPT. The architecture that motivates CARS, trained from scratch; it combines anchor attention, 3D rotary embeddings and FiLM in a branched structure with separate surface and volume decoders. The implementation is adapted to make the comparison like-for-like: width and block counts bring the parameter count to 97.5% of CARS; the data path is extended to this cohort's volumetric fields and evaluation-point sets; flow-rate conditioning is added on the same scalar through the same feature-wise modulation; and the loss is restricted to the volume heads. The surface pressure and vorticity heads carry zero loss weight and remain untrained (relative error ≈1.05 throughout), so the parameter match is nominal and AB-UPT's capacity usable for the supervised objective is below CARS's at equal total parameters. Its geometric input is the surface mesh, which on this cohort is a deterministic function of the centerline and radius profile (§3.1); the data loader carries centerline coordinates and radii into the forward signature, but they are discarded before the model body, verified by tracing the forward pass. AB-UPT trains under mixed precision, which its per-epoch cost requires, while CARS trains in fp32; both are evaluated in fp32, and evaluating AB-UPT under mixed precision instead moves its numbers by to , which settles the scoring question and leaves the training question open, since this architecture family is precision-sensitive in inference (Table 5). Both arms report the best-validation checkpoint.
Figure C.1 places every model on the latency–accuracy plane.

Figure C.1: Latency–accuracy scatter on the LCA test set (test pressure rel- vs. per-case fp32 inference latency on a single A100, both lower-is-better). Filled markers: 300-epoch configurations; hollow markers: matched 100-epoch budget; grey arrows show the within-architecture training-budget improvement. The red dashed line is the stepwise lower-left envelope of the models evaluated here, a property of this particular set of runs rather than a Pareto frontier over architectures: only CARS and AB-UPT were trained at 300 epochs and the baselines were not tuned individually. AB-UPT additionally consumes the surface mesh. The reference pipeline is off-scale to the right.
Appendix D. FFR endpoint: protocol, agreement, baselines and sensitivity
Appendix D.1. Lesion localization and measurement station
The FFR endpoint is evaluated at a lesion-specific measurement point, localized from the geometry alone so that the identical procedure applies to the predicted and the CFD-derived field. The resampled centerline concatenates the branches of the vessel tree, so a step exceeding ten times the median point spacing marks a branch boundary, and all arc-length arithmetic is confined to a single branch. A stenosis is a focal narrowing, distinguished from natural distal tapering by a healthy shoulder on both sides: for every centerline point i within a branch, with s the arc length along that branch,
and the severity is
with and . Requiring both windows to lie inside the same branch excludes distal branch tips by construction. A point is eligible if in addition , a caliber gate reflecting that invasive FFR is not used below about 2 mm diameter, and at least 5 mm of branch remains distal to it. The lesion is the eligible point of maximum severity over the whole tree; one is found in every case of both test sets.
Pressure is sampled 20 mm of arc length distal to the lesion within the same branch, matching the clinical convention of placing the sensor at least 2 cm beyond the lesion, past the pressure-recovery zone; where less vessel is available the point is taken at the distal end of the lesion's branch, which applies to 9% (LCA) and 15% (RCA) of cases. Table D.1 reports sensitivity to the offset under the nearest-point protocol (Appendix D.2): the 20 mm station is the most favorable of the four on LCA and the least favorable on RCA, which is what one expects of a station fixed on clinical grounds before any test-set evaluation. FFR is computed as
with from the solver's kinematic pressure at the measurement point, the unit conversion of Eq. (29) and Pa
Table D.1: Sensitivity of the FFR endpoint to the measurement offset distal to the lesion, on the filtered subset, nearest-point protocol. All offsets are evaluated from the same forward pass. "Clamped" is the fraction of cases in which less than the requested offset of vessel remains and the measurement is taken at the branch end. varies because the physiologic-range filter is applied at the measurement location.
| Offset | Clamped | n | Pearson r | MAE | Acc. @0.8 | |
|---|---|---|---|---|---|---|
| LCA | 5 mm | 0% | 275 | 0.917 | 0.019 | 96.4% |
| 10 mm | 2% | 284 | 0.895 | 0.020 | 96.1% | |
| 20 mm | 9% | 286 | 0.953 | 0.019 | 97.6% | |
| 30 mm | 21% | 283 | 0.945 | 0.024 | 96.1% | |
| RCA | 5 mm | 0% | 294 | 0.994 | 0.008 | 97.6% |
| 10 mm | 4% | 296 | 0.993 | 0.008 | 97.0% | |
| 20 mm | 15% | 293 | 0.994 | 0.008 | 96.2% | |
| 30 mm | 27% | 293 | 0.994 | 0.009 | 96.9% |
(102 mmHg). Since is referred to the inlet it is negative downstream of a lesion, so FFR < 1; the conversion is applied identically to predicted and reference pressure.
Appendix D.2. Exact-coordinate against nearest-point reading
Under the nearest-point protocol the predicted pressure is read at the nearest of the 16,384 sampled query points and the reference at the nearest production cell center, so the predicted value inherits the randomness of the evaluation draw; the primary analysis of §5.4.1 appends the measurement point to the query set instead, and the residual differences between nominally identical baseline figures across the sensitivity tables arise in the analyses that retain the nearest-point protocol: 97.6/97.9/97.6 on LCA, and 96.6% against the 96.2% that the exact-coordinate protocol gives at the same 20 mm station on RCA. The spread is the sampling term the primary protocol removes.
Table D.2 gives the two protocols of §5.4.1 side by side. Exact querying leaves the threshold decision essentially untouched, changing no case on LCA and one on RCA, and improves the full-cohort correlation on LCA from 0.921 to 0.941 while leaving the physiologic-range subset and both RCA scopes unchanged to three decimals. The improvement is concentrated where it should be: the nearest-point offset perturbs a small number of cases with steep local pressure gradients, which are exactly the near-occlusive cases the subset excludes, so the defect was invisible on the filtered numbers and visible on the full cohort. The sampling step also contributes about 0.01 of run-to-run variation in on its own, since two draws of the query set place different points near .
Table D.2: Effect of reading the predicted pressure at the exact measurement coordinate rather than at the nearest of the 16,384 sampled query points, at the primary 20 mm station. The reference is the nearest production cell center in both columns. The measurement station, the lesion localization and the case counts are identical between the two, so the difference is attributable to the lookup alone.
| Territory | Scope (n) | Nearest point | Exact coordinate | ||||
|---|---|---|---|---|---|---|---|
| r | MAE | Acc. | r | MAE | Acc. | ||
| LCA | full (300) | 0.921 | 0.028 | 97.7% | 0.941 | 0.026 | 97.7% |
| subset (286) | 0.953 | 0.020 | 97.6% | 0.953 | 0.019 | 97.6% | |
| RCA | full (300) | 0.993 | 0.010 | 96.3% | 0.993 | 0.010 | 96.3% |
| subset (293) | 0.994 | 0.008 | 96.2% | 0.994 | 0.008 | 96.2% | |
Appendix D.3. Physiologic-range subset and agreement analyses
The physiologic-range subset of §5.4.1 keeps the cases whose reference FFR lies in , 286 of 300 on LCA and 293 of 300 on RCA, where the reference value is itself a threshold comparison. Excluding the tail raises and lowers MAE, because the excluded cases carry the largest absolute reference values and the largest absolute errors; no conclusion in the paper differs between the two scopes. Figures D.1 and D.2 show the ROC curves and Bland-Altman plots behind the agreement figures quoted there; the ROC AUC carries patient-clustered bootstrap confidence intervals [0.989, 0.999] (LCA) and [0.990, 0.999] (RCA). Every interval in Table 6 is clustered on the patient, because the 300 test cases of each territory are variants of 96/111 segmentations and are not mutually independent. Clustering widens the intervals only marginally, by a factor of 1.0–1.3 across the six metrics and both territories, and narrows marginally on two of them: what drives an FFR value is the lesion, and lesion severity varies within a patient as much as between patients, so little of the endpoint variance is absorbed by the patient grouping. The threshold-level conclusions are therefore not an artifact of counting correlated cases as independent.
The two summaries answer different questions. The LCA limits of agreement span across the FFR level, so a case whose reference value lies close to that level can be predicted on the other side of it under prediction spread alone; this single-case spread is not visible in the cohort-level threshold agreement of 97.6%. The RCA limits are roughly three times tighter, consistent with the lower field errors on that territory.

Figure D.1: ROC curves for the binary FFR 0.8 decision on LCA (left) and RCA (right). Red marker: operating point at the clinical cutoff. Dotted line: chance.

Figure D.2: Bland–Altman plots of predicted vs. CFD-derived FFR for LCA (left) and RCA (right). Solid line: bias; dashed lines: 95% limits of agreement.
Appendix D.4. One-dimensional blood-flow reduced-order model
The 1D ROM combines the viscous Hagen–Poiseuille pressure drop with the convective (Bernoulli) acceleration term, integrated along the anatomical path from the inlet to the same measurement point used for CARS:
with (parabolic-profile momentum-flux correction, placed on the convective term where it belongs; the viscous gradient is already exact for that profile), Pas, kg/m and . Placing on the viscous term instead would inflate the viscous loss by 33% and move the baseline very little: threshold agreement 49.0% against 47.2% on LCA and unchanged at 77.1% on RCA, MAE 0.376 against 0.381 (LCA) and 0.099 against 0.096 (RCA), Pearson 0.191 against 0.193 (LCA) and 0.559 against 0.620 (RCA).
Three points make the comparison a fair one. First, the integration path follows the vessel tree: branch connectivity is reconstructed by attaching each branch to the nearest point of an earlier branch, and the path is the resulting chain from the inlet through the parent junctions to the measurement point. Second, is the flow carried by the branch containing s, not the total inlet flow: since the upstream pipeline prescribes each terminal flux in proportion to the square of the terminal luminal radius (Eq. (6)), a branch carries the summed terminal flux of its own subtree,
with the terminals downstream of branch , so the ROM is driven by the same outflow distribution as the 3D reference. Third, all quantities are converted once from the pipeline's (mm, s, kg) system to SI, so Eq. (D.4) is evaluated with physical constants and no empirical flow-rate rescaling is fitted. FFR follows as with Pa, matching Eq. (D.3), and is clipped to [0, 1].
The resulting baseline reaches Pearson and threshold accuracy 49.0%/77.1% on LCA/RCA against majority-class baselines of 78.7%/68.3% (Table D.3), and is markedly weaker on LCA than on RCA. This is a property of the model class: in a tapering tube both terms of Eq. (D.4) scale as , and both overestimate the pressure drop where the true loss is governed by flow separation and partial pressure recovery rather than by fully developed viscous shear or by a lossless Bernoulli exchange. On LCA the two terms are of the same order (medians 1,939 Pa viscous and 1,436 Pa convective), and the median per-case convective share of is 53% against 20% on RCA (medians 1,132 and 307 Pa), so on LCA the convective term is the larger one in more than half of cases; the mechanism is geometric, since the measurement station sits in a distal vessel whose median radius is 0.89 mm against an inlet 2.05 mm, and on 85 of 286 LCA cases the total predicted drop exceeds aortic pressure and the FFR estimate clips at zero. The LCA cohort also carries more severe lesions (median severity 0.46 versus 0.24). Fitting a single global coefficient on the viscous term using training cases only does not rescue it: the fitted coefficient collapses towards zero on LCA, trading the over-prediction for a near-constant FFR ≈ 1, so the uncalibrated, dimensionally consistent model is reported. It is a physics sanity check rather than a head-to-head against modern 1D solvers (SimVascular's 1D solver, openBF), which include vessel compliance and proper outlet impedances and would be expected to perform substantially better; the reduced-order comparator a computational-mechanics reader would expect is a one-dimensional solver carrying an explicit stenosis-loss closure (of Young-Tsai type, as in the reduced-order model of [11]), which is the single largest gap in the comparison set of the paper.
Appendix D.5. Same-data scalar-regression baseline
An Itu-style scalar regressor [11] and an XGBoost upper bound were trained on the same splits and the same CFD-derived FFR labels as CARS, using 15 hand-engineered per-vessel geometric features (min/mean/proximal/ distal radius, stenosis severity, total and to-stenosis arc length, tortuosity, mean and max curvature, stenosis length, 5 mm-window mean radius, inlet flow rate), with hyperparameters tuned on the validation split. Table D.3 reports them alongside the ROM and CARS. Their AUCs are not comparable to the 0.84–0.93 band reported for machine-learning ct-FFR in the prior literature [44, 42, 45], which is measured against invasive FFR on clinical cohorts, whereas these are measured against a CFD label on a synthetic product distribution of geometries and flow rates; numerical proximity between the two carries no information about calibration.
Appendix D.6. Sensitivity and triage tables
Tables D.4–D.6 are the numerical values behind Figure 5 and §5.4.2. The MC-dropout predicted standard deviation is overconfident as an absolute interval, with coverage of 52% on LCA and 44% on RCA against a calibrated 68% and coverage of 0.68/0.69 against a nominal 0.95; turning it into a calibrated interval would take a different uncertainty formulation rather than a rescaling of this one. The cutoff transfers less cleanly on RCA,
Table D.3: FFR endpoint: CARS versus the uncalibrated, dimensionally consistent 1D blood-flow ROM and Itu-style per-vessel scalar regressors on the same CFD-derived FFR labels and the same train/val/test splits (), physiologic-range subset, nearest-point protocol. “Scalar MLP (Itu)” is the two-layer feed-forward network of Itu et al. [11]; “Scalar XGB” is a gradient-boosted upper bound on what scalar feature regression can extract from the same 15 features. AUC and accuracy carry patient-clustered bootstrap 95% CIs. Always predicting the majority class gives 78.7% (LCA) and 68.3% (RCA).
| Method | r | MAE | Acc. @0.8 | AUC |
|---|---|---|---|---|
| LCA, n = 286 | ||||
| 1D ROM | 0.191 | 0.376 | 49.0% | 0.54 |
| Scalar MLP (Itu) | 0.730 | 0.070 | 89.2% [85.0, 92.3] | 0.92 [0.87, 0.96] |
| Scalar XGB | 0.810 | 0.050 | 91.3% [87.4, 94.0] | 0.96 [0.93, 0.98] |
| CARS | 0.953 | 0.019 | 97.6% | 0.995 [0.989, 0.999] |
| RCA, n = 293 | ||||
| 1D ROM | 0.559 | 0.099 | 77.1% | 0.84 |
| Scalar MLP (Itu) | 0.760 | 0.070 | 78.8% [73.8, 83.1] | 0.88 [0.83, 0.91] |
| Scalar XGB | 0.840 | 0.040 | 89.8% [85.8, 92.7] | 0.93 [0.90, 0.96] |
| CARS | 0.994 | 0.008 | 96.2% | 0.995 [0.990, 0.999] |
whose validation-side distribution has a heavier tail, so the realized fraction departs from its target.
Table D.4: Val-tuned MC-dropout triage on the filtered subset (, ). The -percentile cutoff is set on val and applied unchanged to test; "realized" is the resulting test routing fraction. Auto-rep. accuracy is the threshold accuracy on the auto-reported subset; the MC-mean baseline (no routing) on test is LCA / RCA.
| Territory | Target f | σcut (val) | Realized | Err. absorbed | Auto-rep. acc. |
|---|---|---|---|---|---|
| LCA | 10% | 0.0103 | 11.2% | 37% | 98.0% |
| LCA | 20% | 0.0072 | 23.8% | 61% | 98.6% |
| RCA | 10% | 0.0060 | 12.3% | 31% | 96.1% |
| RCA | 20% | 0.0046 | 25.9% | 56% | 96.8% |
Table D.5: Input-noise robustness on the same filtered subset and the same model checkpoint as §5.4.1. The row is the unperturbed baseline; it differs from Table 6 because the evaluation points are resampled per run, by up to 0.008 in , so the perturbation rows are to be read against the row of this table. Centerline noise is additive isotropic Gaussian (mm) applied independently to each of the 2,048 points; radius noise is multiplicative fractional Gaussian on raw radii.
| Territory | Noise type | MAE | Acc. @ 0.8 | ||
|---|---|---|---|---|---|
| LCA | Baseline | 0 | 0.949 | 0.021 | 97.9% |
| LCA | Centerline (mm) | 0.1 | 0.948 | 0.021 | 97.2% |
| LCA | 0.5 | 0.949 | 0.021 | 97.6% | |
| LCA | 1.0 | 0.945 | 0.022 | 97.2% | |
| LCA | Radius (frac) | 0.05 | 0.946 | 0.021 | 96.9% |
| LCA | 0.10 | 0.910 | 0.036 | 93.4% | |
| LCA | 0.20 | 0.653 | 0.127 | 62.2% | |
| RCA | Baseline | 0 | 0.991 | 0.011 | 96.6% |
| RCA | Centerline (mm) | 0.1 | 0.993 | 0.010 | 96.2% |
| RCA | 0.5 | 0.992 | 0.017 | 93.5% | |
| RCA | 1.0 | 0.970 | 0.080 | 84.0% | |
| RCA | Radius (frac) | 0.05 | 0.990 | 0.012 | 96.6% |
| RCA | 0.10 | 0.991 | 0.014 | 96.9% | |
| RCA | 0.20 | 0.912 | 0.047 | 86.0% |
Table D.6: Segment-level structured perturbations on the same filtered subset. A contiguous 10-mm arc-length window is selected uniformly at random per case and a single bias is applied to every centerline point in it: “segment-position” a 3D Gaussian displacement of magnitude mm, “segment-radius” a multiplicative factor . Seed fixed across values. The row is the unperturbed baseline for this table.
| Territory | Perturbation | MAE | Acc. @ 0.8 | ||
|---|---|---|---|---|---|
| LCA | Baseline | 0 | 0.946 | 0.021 | 97.6% |
| LCA | Segment-position (mm) | 0.5 | 0.949 | 0.021 | 97.9% |
| LCA | 1.0 | 0.948 | 0.021 | 97.6% | |
| LCA | 2.0 | 0.945 | 0.022 | 97.6% | |
| LCA | Segment-radius (frac) | 0.05 | 0.949 | 0.021 | 97.9% |
| LCA | 0.10 | 0.947 | 0.021 | 97.6% | |
| LCA | 0.20 | 0.947 | 0.022 | 97.2% | |
| RCA | Baseline | 0 | 0.992 | 0.010 | 96.2% |
| RCA | Segment-position (mm) | 0.5 | 0.991 | 0.011 | 96.6% |
| RCA | 1.0 | 0.992 | 0.011 | 96.6% | |
| RCA | 2.0 | 0.991 | 0.012 | 95.9% | |
| RCA | Segment-radius (frac) | 0.05 | 0.991 | 0.011 | 96.9% |
| RCA | 0.10 | 0.993 | 0.010 | 96.9% | |
| RCA | 0.20 | 0.965 | 0.016 | 94.9% |
Appendix E. Error structure, invariances and transfer
Table E.1 is the full binned table behind Figure 6, Table E.2 the frame-sensitivity measurement of §5.5.2, Tables E.3 and E.4 the consistency with the governing equations, and Table E.5 the cross-territory transfer of §5.5.3; Appendix E.1 reports an anatomy-disjoint partition.
Consistency with the governing equations: protocol. Derivatives are taken by automatic differentiation of the network with respect to its evaluation coordinates, with the chain rule applied through the coordinate normalization, so all quantities are in the pipeline's physical units. First derivatives use a single reverse pass. The Laplacian uses a symmetric finite-difference stencil of width 0.05 mm, because the fused attention kernels provide no second-order backward and the exact-arithmetic fallback does not fit in memory at the trained anchor count. Quantities are made dimensionless with the per-case mean speed U and median lumen diameter D: the divergence as and the momentum residual by the convective scale ; fifty test cases per territory, 4,096 interior points each (Table E.3). The stencil width is larger than the near-wall cell height of the reference mesh, which is 0.75% of the local radius and therefore of order 0.005–0.015 mm, and the interior points are drawn from the set of mesh cell centers with no wall-clearance criterion, so for points within a stencil width of the wall some stencil arms fall outside the lumen, where the network was never supervised. Measuring the distance from each sampled point to the nearest point of the production lumen surface, 39% of sampled points lie within one stencil width of the wall and the fifth percentile of that distance is zero. The affected quantity is the Laplacian, and hence the momentum residual; the divergence uses first derivatives and is exact. Table E.4 recomputes the medians on subsets progressively clear of the wall: the momentum residual falls from 2.66 over all points to 1.57 at one stencil width of clearance and 1.31 at two, while the divergence moves comparatively little, exactly the asymmetry the mechanism predicts. The all-points momentum residual is therefore inflated by roughly a factor of 1.7 by points whose stencils leave the lumen; the wall-clear value is taken as representative, and at 1.57 the residual is still of the order of the convective term itself. The inlet flux diagnostic integrates over a cross-section by disc quadrature and does not depend on the stencil.
Appendix E.1. An anatomy-disjoint partition of the same cases
The partition used throughout the paper is over samples of the parameter set , which is what a surrogate of a parametric solution map
Table E.1: Per-case relative error against the parameters of the solution map, on the full 300-case test split of each territory (Figure 6 plots the pressure column). Entries are the mean over the bin; is the number of cases. Severity bands and branch counts are absolute; flow-rate and radius bins are per-territory quartiles, with edges LCA 5,045/5,745/6,448/7,318/7,997 and RCA 2,515/2,988/3,574/3,985/4,486 mm/s for , LCA 1.32/1.88/2.06/2.24/2.50 and RCA 1.51/1.81/1.98/2.12/2.29 mm for inlet radius, and LCA 0.26/0.57/0.72/0.90/1.50 and RCA 0.44/0.75/0.93/1.12/1.92 mm for throat radius. The Spearman row is the rank correlation of the covariate with each error over all 300 cases. n/a marks bins the territory does not populate.
| Bin | LCA | RCA | ||||
|---|---|---|---|---|---|---|
| Pressure | Velocity | Pressure | Velocity | |||
| Lesion severity , fixed bands | ||||||
| [0.00, 0.20) | 5 | 0.073 | 0.136 | 133 | 0.070 | 0.118 |
| [0.20, 0.35) | 42 | 0.069 | 0.137 | 51 | 0.063 | 0.119 |
| [0.35, 0.50) | 165 | 0.121 | 0.148 | 80 | 0.052 | 0.115 |
| [0.50, 0.65) | 69 | 0.123 | 0.141 | 34 | 0.059 | 0.130 |
| [0.65, 1.00] | 19 | 0.190 | 0.191 | 2 | 0.173 | 0.118 |
| Spearman | 300 | +0.166 | +0.160 | 300 | -0.048 | +0.006 |
| Branch count | ||||||
| 1 | 0 | n/a | n/a | 39 | 0.075 | 0.119 |
| 2 | 3 | 0.047 | 0.103 | 197 | 0.048 | 0.111 |
| 3 | 79 | 0.115 | 0.129 | 64 | 0.103 | 0.141 |
| 4 | 122 | 0.111 | 0.144 | 0 | n/a | n/a |
| 5–6 | 89 | 0.134 | 0.173 | 0 | n/a | n/a |
| 7 | 0.074 | 0.097 | 0 | n/a | n/a | |
| Spearman | 300 | +0.175 | +0.239 | 300 | +0.250 | +0.254 |
| Inlet flow rate (mm/s), per-territory quartiles | ||||||
| Q1 | 74 | 0.129 | 0.149 | 75 | 0.072 | 0.117 |
| Q2 | 75 | 0.126 | 0.158 | 74 | 0.060 | 0.115 |
| Q3 | 76 | 0.096 | 0.130 | 76 | 0.062 | 0.119 |
| Q4 | 75 | 0.120 | 0.152 | 75 | 0.060 | 0.124 |
| Spearman | 300 | -0.064 | -0.035 | 300 | -0.090 | +0.124 |
| Inlet radius (mm), per-territory quartiles | ||||||
| Q1 | 73 | 0.119 | 0.161 | 75 | 0.072 | 0.124 |
| Q2 | 74 | 0.118 | 0.142 | 73 | 0.066 | 0.122 |
| Q3 | 75 | 0.124 | 0.140 | 77 | 0.048 | 0.113 |
| Q4 | 78 | 0.109 | 0.147 | 75 | 0.068 | 0.117 |
| Spearman | 300 | -0.091 | -0.077 | 300 | +0.022 | +0.026 |
| Lesion throat radius (mm), per-territory quartiles | ||||||
| Q1 | 72 | 0.155 | 0.152 | 75 | 0.064 | 0.132 |
| Q2 | 77 | 0.108 | 0.160 | 75 | 0.052 | 0.109 |
| Q3 | 76 | 0.088 | 0.135 | 75 | 0.061 | 0.116 |
| Q4 | 75 | 0.120 | 0.142 | 75 | 0.077 | 0.119 |
| Spearman | 300 | -0.117 | -0.119 | 300 | +0.032 | -0.064 |
Table E.2: Sensitivity to the frame in which the inputs are expressed. LCA, 100-case subset of the test split, fp32, mean relative against the unperturbed reference fields with predicted velocity counter-rotated. The rotation is about the case centroid through the stated angle about a randomly drawn axis, applied jointly to the centerline and the evaluation points; the translation is of the stated magnitude in a random direction. The zero rows reproduce the single-run headline errors and are the protocol control. An equivariant surrogate would return the zero row at every perturbation.
| Rotation | Pressure | Velocity | Translation | Pressure | Velocity |
|---|---|---|---|---|---|
| 0.117 | 0.146 | 0 mm | 0.117 | 0.146 | |
| 0.121 | 0.150 | 1 mm | 0.120 | 0.150 | |
| 0.134 | 0.175 | 2 mm | 0.126 | 0.160 | |
| 0.178 | 0.260 | 5 mm | 0.160 | 0.232 | |
| 0.340 | 0.483 | 10 mm | 0.414 | 0.469 | |
| 2.25 | 1.40 | 20 mm | 39.3 | 21.2 | |
| 15.1 | 11.9 |
Table E.3: Consistency with the governing equations, evaluated by automatic differentiation of the trained network. Medians over 50 test cases per territory; “p90 over points” is the median across cases of the 90th-percentile value within a case. Dimensionless by the per-case mean speed and median diameter .
| Diagnostic | LCA | RCA |
|---|---|---|
| , median | 0.26 | 0.30 |
| p90 over points | 1.38 | 1.18 |
| Momentum residual , median | 2.56 | 2.86 |
| p90 over points | 17.2 | 13.1 |
| Inlet flux error | 12.2% | 5.5% |
is asked to interpolate and which is applied identically to every model compared. A different question can be asked of the same data: how well does a model trained on one set of segmentations predict flow in a vessel tree it has never seen? This subsection reports that experiment. It is not the paper’s claim: this cohort cannot answer the question with useful precision, and the interval below shows by how much.
Construction. The same 3,300 solved LCA cases were re-partitioned so that every case derived from one ImageCAS segmentation falls in exactly one split. No CFD was re-run. Training was held at 2,686 cases, close to the 2,700 of the main split so the model is not handicapped, leaving 83 anatomies for
Table E.4: PDE-consistency medians restricted to points at least the stated distance from the lumen wall, on 50 LCA test cases with 2,048 interior points each and the stencil. Wall distance is measured to the nearest point of the production surface mesh. This is an independent draw at half the point count of Table E.3, so the zero-clearance column agrees with that table to within the draw (0.251 against 0.26, 2.66 against 2.56); the comparison to read is across the columns of this table, which share a draw.
| Wall clearance | ||||
|---|---|---|---|---|
| Points retained | 100% | 61% | 51% | 35% |
| , median | 0.251 | 0.226 | 0.207 | 0.168 |
| Momentum residual , median | 2.656 | 1.574 | 1.311 | 1.038 |
Table E.5: Zero-shot LCA→RCA transfer of the 300-epoch LCA checkpoint on the 300-case RCA test split, under four choices of input normalization. Output is always denormalized with the LCA training statistics and compared with RCA ground truth in physical units. Errors are pooled relative . “Best scale” is the single global factor minimizing the pressure error; the last two columns give the error after applying it. A best scale of zero with a scaled error of one means the prediction carries no usable signal. Predicted norms are 9.7 and 3.6 times the reference in the first and third rows, with a predicted mean pressure of the wrong sign.
| Input normalization | Pressure | Velocity | Best scale | Pressure* | Velocity* |
|---|---|---|---|---|---|
| positions, radius, Q all LCA | 15.71 | 27.55 | -0.002 | 1.000 | 1.000 |
| positions RCA; radius, Q LCA | 10.18 | 22.72 | +0.001 | 1.000 | 1.000 |
| positions, radius RCA; Q LCA | 7.01 | 14.82 | +0.005 | 0.999 | 1.000 |
| positions, radius, Q all RCA | 22.52 | 31.93 | +0.001 | 0.999 | 1.000 |
*after the best global rescaling.
training, 7 for validation and 11 for test (241 and 373 cases). Because a test set of a dozen anatomies can easily be harder or easier than the training set by chance, the allocation was chosen by search to balance train against test on the five covariates of Table E.1: the largest standardized mean difference is 0.107. Normalization statistics were recomputed from this training split alone: the coordinate bounding box used elsewhere is computed over all three splits, and on an anatomy-disjoint partition it could otherwise carry the test anatomies' spatial extent into training. CARS and the strongest baseline, AB-UPT, were then trained on this partition under the configurations of §3 and scored with each model's own evaluation code.
Result. Table E.6 reports it. Both constructions degrade sharply: predicting flow in an unseen vessel tree is a different and much harder problem than interpolating lesion and flow parameters on trees the model has seen, and neither architecture does it well when trained on 83 anatomies. CARS has the lower error of the two on both fields, on 8 of 11 anatomies for pressure and 10 of 11 for velocity.
Why this cohort cannot settle the question. The 373 test cases are not 373 independent observations. They come from 11 segmentations, and of the variance in per-case pressure error lies between anatomies rather than within one; per-anatomy mean pressure error ranges from 0.26 to 1.69. Resampling anatomies rather than cases, the interval on CARS's pressure error is [0.44, 0.93], spanning a factor of 2.1. Treating the cases as independent would give [0.61, 0.71], an interval five times narrower and wrong. The paired margin over AB-UPT is [] on velocity, which excludes zero, and on pressure, which does not. On this partition CARS is the more accurate of the two on both fields and on the large majority of anatomies, the velocity margin is resolved and the pressure margin is not, and the absolute level is determined only to within a factor of two. A cohort with enough segmentations to resolve it is a data-collection problem, not an architecture problem.
Table E.6: Anatomy-disjoint partition of the same 3,300 LCA cases: 83 training anatomies, 11 test anatomies, 373 test cases, covariate-balanced against training to a largest standardized mean difference of 0.107. Intervals are patient-clustered bootstrap CIs () resampling the 11 test anatomies. The parametric column is the 300-epoch three-seed result of Table B.2 for reference. Both anatomy-disjoint runs use best-validation checkpoints; both had plateaued well before selection, and two CARS checkpoints 60 epochs apart agree to .
| Field | Model | Parametric split (Table B.2) | Anatomy-disjoint mean [95% CI] |
| Pressure | CARS | 0.120 | 0.662 [0.445, 0.934] |
| AB-UPT | 0.158 | 0.812 [0.553, 1.235] | |
| margin | +0.039 | +0.150 [-0.017, +0.350] | |
| Velocity | CARS | 0.149 | 0.681 [0.594, 0.773] |
| AB-UPT | 0.172 | 0.789 [0.686, 0.908] | |
| margin | +0.023 | +0.109 [+0.055, +0.168] |
Appendix F. Upstream CFD pipeline
The supervisory fields are produced by an OpenFOAM pipeline applied to the ImageCAS-derived geometries.
Unit system. The pipeline is formulated throughout in a self-consistent (mm, s, kg) system: lengths in mm, kinematic viscosity in mm²/s, density in kg/mm³, volumetric flow rate in mm³/s, and kinematic pressure in mm²/s². The OpenFOAM dimensions entries are nominally SI-labeled, but OpenFOAM does not verify them and every quantity is consistently interpreted in the system above, so the reported pressure drops and derived quantities are unaffected.
Solver and discretization. OpenFOAM Foundation v11 [53], build 11-e1fc8c682ae6, invoked as foamRun -solver incompressibleFluid through the simpleFoam depreciation shim; the solver reports operation in SIMPLE mode, so the runs are SIMPLE and not SIMPLEC. Convection, gradient and Laplacian terms use formally second-order schemes, and the pressure system is solved with a geometric-algebraic multigrid. The number of non-orthogonal correctors differs between the territory pipelines (20 on LCA against 2 on RCA) and makes no difference, since on a structured hexahedral mesh two passes already resolve the non-orthogonality: re-solving one case with both settings to a residual floor gives fields that agree to relative in pressure and in velocity, with an identical FFR to every printed digit; both settings reach the floor in the same number of iterations (1,378 against 1,377), and the higher LCA setting costs about in core-seconds. Blood is Newtonian, and ( , , physiologic values at the upper end of the usual range and the values used in the 1D ROM of Appendix D.4), the wall rigid and no-slip, and the solve steady: pulsatile and transient phenomena, among them wave reflection and the instantaneous wave-free ratio [54, 55], are absent from the supervision.
Boundary conditions. The inlet carries a fixed-value kinematic pressure with a pressureInletOutletVelocity velocity condition. Each terminal branch carries a prescribed volumetric flux (flowRateOutletVelocity), with the total Q distributed by Eq. (6); Q is the quantity sampled per case and consumed by CARS through the FiLM pathway. Per-case Q is drawn uniformly over a per-territory range spanning the published physiologic range for resting and hyperemic coronary flow, and independently of the geometry: statistically an advantage for identifying the flow-conditioning pathway, since the model cannot recover Q from geometric cues, and physiologically the reason the prevalence of FFR 0.8 in this dataset is a property of the sampling design and not of a clinical population.
Mesh. Volume meshes are generated with the structured hexahedral vessel mesher of Decroocq et al. [47], which sweeps a circular cross-section along the centerline as a block-structured O-grid, so every cross-section is circular by construction and the lumen is exactly the tubular image of Eq. (13). Every cross-section carries 324 cells (26–30 cells across the diameter at every station, so a 0.18 mm throat radius still carries the full cross-section), the near-wall cell height is 0.75% of the local radius, and the representative case of Figure 3 has 292,572 = 324 × 903 cells. Axial spacing is ≈0.2 mm and does not contract at a throat, so a focal lesion a few millimetres long is spanned by ten to twenty axial cells; the grid-convergence study below, whose refinement family is axial as well as circumferential, bounds the combined effect.
Reynolds number. With Re = 2Q/(πrν) and r the proximal-segment mean radius (median 1.91 mm on LCA), the inlet Reynolds number over the test splits has median 571 (IQR 509–667, max 1,045) on LCA and 316 (IQR 272–349, max 519) on RCA; the sampled flow rates correspond to 300–480 mL/min on LCA and 150–270 mL/min on RCA, against a resting total coronary flow of ≈250 mL/min and a coronary flow reserve of 2.5–4 under adenosine [3, 1]. At the located lesion, with the flux the subtree's share, the throat Reynolds number has median 1,056 (p95 2,143) on LCA and 647 (p95 1,203) on RCA; only 4.3% of LCA cases and no RCA case exceed the classical transition value of ≈2,300, so the laminar reference is well supported over the bulk of the cohort, with a small upper tail on the left tree where a post-stenotic jet could be transitional.
Iteration, convergence and the retention filter. The pipeline runs a fixed 4,000 SIMPLE iterations per case and retains a case only if its final pressure residual falls below . Re-solving a representative case with a residual floor of on both pressure and velocity met that floor after 2,751 iterations, and the two solutions agree over all 254,016 cells to relative in pressure, in velocity and in FFR, so iteration error is more than three orders of magnitude below the discretization error; global mass conservation holds to machine precision by construction of the boundary conditions and is not independent evidence of convergence. Of the solves that run to completion, the residual filter removes 9.9% (RCA)
Table F.1: Grid Convergence Index at the production resolution, from three levels at 160/324/544 cells per cross-section with realized ratios , , over sixteen cases. Field norms are volume-weighted; median and interquartile range over cases. Two cases have not reached the asymptotic range (observed orders 0.48 and 0.47) and are retained; the bracketed figure is the pressure-norm median without them.
| Quantity | LCA (n=8) | RCA (n=8) | All (n=16) |
|---|---|---|---|
| Pressure, vol.-weighted | 1.99% | 1.36% | 1.61% [≈1.5%] |
| IQR | 1.14–5.86% | 0.73–2.37% | 0.93–3.56% |
| Velocity, vol.-weighted | 0.27% | 0.29% | 0.29% |
| IQR | 0.06–0.47% | 0.13–0.35% | 0.12–0.46% |
| FFR, minimum-pressure proxy | 0.83% | 0.26% | 0.41% |
| IQR | 0.33–3.38% | 0.15–0.55% | 0.25–0.99% |
| Observed order p, pressure | median 2.51 | ||
| Observed order p, velocity | median 3.28 |
and 13.3% (LCA), and counted against all attempted solves 24 of 133 and 37 of 102, because early terminations are also absent. Removal tracks mesh quality (among removed cases 46% (RCA) and 70% (LCA) fail checkMesh, against 1% and 17% of retained cases), on RCA the removed set carries higher flow (median Q 4,271 against 3,331 mm /s), and lesion severity was not measured on the removed set. The filter is applied before the splits are constructed.
Appendix F.1. Grid convergence of the reference solutions
A three-level Grid Convergence Index study [56, 57, 58] on sixteen cases, eight per territory (selection below), refines the production meshes. Table F.1 reports the result; the paragraphs below give the construction and what the figure establishes.
Holding the geometry fixed across refinement levels. A refinement study requires the same domain at every level, which is not trivial here because the production mesher injects each stenosis through an unseeded random draw and records neither the draw nor its result: regenerating a case from its source centerline yields a different lesion. Each case's lesion parameters were therefore recovered from its production mesh. Generating a stenosis-free mesh at production resolution gives point-for-point index correspondence with the production mesh, so differencing the two point sets isolates the displaced points, and mapping those onto the vessel graph recovers the carrying edge and the lesion's start and end positions along it. For the validation case all 71,904 displaced points of 304,954 lie on a single edge, so the recovery is unambiguous, and the recovered extent is interior to the production sampling bounds. Regenerating at production resolution from the recovered parameters reproduces the production mesh to six significant figures in cell count (292,572), maximum non-orthogonality (52.3779°), maximum skewness (2.74534) and maximum aspect ratio (52.7179), with a maximum point deviation of 0.0195 mm against a lesion deformation amplitude of 0.578 mm. The study therefore refines the production geometries themselves.
Refinement levels and ratios. The mesher’s circumferential division count N must be a multiple of eight, which fixes the available levels at N = 16, 24, 32, carrying 160, 324 and 544 cells per cross-section. Refinement is simultaneously axial, so the three levels carry 96,320, 292,572 and ≈655,000 cells on the validation case. Realized refinement ratios from cell counts are and ; these are not equal, so the closed-form GCI does not apply and the iterative non-constant-ratio formulation is used, solving for the observed order p from the realized ratios of each case. Mesh quality does not degrade: maximum skewness falls from 2.97 to 2.70 and maximum non-orthogonality stays within 52–57° across levels, every study mesh passes checkMesh, and topology and patch ordering are identical at all three levels. The domain converges with the mesh rather than being exactly fixed, because N circumferential divisions inscribe an N-gon in each circular cross-section; the resulting volume deficit is , giving 2.55%, 1.14% and 0.64% at the three levels, confirmed against measured mesh volumes, so the geometric error converges at the same second order as the schemes and enters the GCI as part of one second-order error term. Boundary conditions are held identical across levels by copying each production per-outlet flux verbatim, and all levels are run to the same residual floor.
Case selection. A case qualifies when all three levels are solved and readable, all three converged (residual floor met or final pressure residual below ), checkMesh is clean at all three study levels, and checkMesh is clean on the production mesh (a production mesh that fails carries inverted cells, and such cases terminate on a floating-point exception at the finer levels). Among qualifying cases eight per territory were drawn at evenly spaced quantiles of the production mesh's maximum non-orthogonality, so that each cohort's runnable mesh-quality range is spanned. Of twenty-one completed triples, eighteen qualified (nine in each territory) and sixteen were selected. Nothing is filtered or ranked on observed order, on GCI, on lesion presence, or on reference FFR. The single LCA case at the worst production mesh quality degraded under refinement, its fine level failing checkMesh, so mesh quality is stable under refinement across the range the study covers but not beyond it.
The quantity the GCI is computed on. Each level's norm is the global volume-weighted root mean square on its own mesh, , and the three per-level scalars enter the Richardson extrapolation as an ordinary scalar quantity of interest; no coarse or medium field is ever interpolated onto the fine mesh. The implemented expression is with applied to the relative error, so the bare Richardson estimates are the reported values divided by 1.25. A global root mean square is subject to cancellation, so the GCI plausibly understates the pointwise discretization error and says nothing about where that error sits; peri-stenotic restricted norms were not computed.
Observed orders. The pressure median of 2.51 is close to the formal second order and is the principal evidence that the triples are in the regime a refinement study requires. The velocity median of 3.28 is not: an observed order substantially above the formal order indicates a triple outside the asymptotic range, since in the asymptotic regime the observed order should approach the formal one rather than exceed it by 60%, so the velocity GCI is an order-of-magnitude indication. Two of the sixteen cases sit at and are retained rather than dropped, since removing them would reintroduce selection on the outcome. Restricting the index to triples with observed order in a band around 2 and reporting the remainder separately is the analysis that would separate these populations; it has not been done.
How the figure bounds the surrogate error. First, the norms differ: the GCI is volume-weighted, whereas the surrogate errors are unweighted over a point set drawn uniformly over cell centers, which with wall-graded cells overweights the near-wall region. Computing on a common point set, and reporting the surrogate error in the volume-weighted norm as well, is what would make the two commensurable. Second, the comparison is only meaningful median against median: the surrogate's LCA pressure error has median 0.065 and mean 0.116, so median against median the ratio is about three and mean against median nearly six; on RCA the mean ratio is about five, and on velocity the ratios are an order of magnitude larger (0.146 against 0.27% and 0.119 against 0.29%). At the GCI upper quartile (5.86% on LCA, estimated from few points) the reference error is comparable to the surrogate's median. Third, part of the reference error is a boundary-approximation bias: the N-gon inscription leaves a 1.14% volume deficit at production resolution, hence a radius deficit of , which with accounts for a pressure error of order 2.3%, of the same size as the entire reported LCA pressure GCI. Because this deficit is a deterministic function of the resolution applied identically to every case, it shifts all labels in the same direction and a surrogate trained on them reproduces the shift; to that extent the reference error places no floor on measured agreement. Separating the two components requires refining circumferentially with an area-preserving radius correction, or projecting vertices onto the exact circle at every level. The territory difference is the substantive finding: LCA carries 1.5 times RCA's pressure-norm error and 3.2 times its FFR error, with a heavier upper tail, consistent with LCA being the harder cohort throughout.
The endpoint station is better converged than the domain minimum. The minimum-pressure proxy evaluates over the whole domain; the endpoint is read 20 mm distal to the lesion within its own branch. Because every terminal flux is prescribed, static pressure falls monotonically along each branch, so the domain minimum sits at the end of whichever terminal branch carries the largest cumulative resistance: on twenty LCA test cases it lies at a station of local radius 0.40 mm against a cohort median of 1.12 mm, at 88% of the way along the centerline, in the smallest cells in the domain and not at the stenosis throat. Recomputing the FFR row at the recorded 20 mm coordinates on all three levels gives a median GCI of 0.055% (IQR 0.007–0.338%) against 0.41% for the proxy, and a median between the production level and the extrapolate of 0.0010 against 0.0054; the 30 mm station agrees (0.068%; 0.0011). The station is geometrically unavailable in three of the sixteen cases (3.74, 4.27 and 19.05 mm of vessel distal to the lesion) and one further case yields no usable triple, so ; five of those twelve are stenosis-free cases in which the station is 20 mm from the inlet, leaving lesioned cases; one case (GCI 9.78% at an observed order of 0.94) is not in the asymptotic range and is retained, excluding it the maximum falls to 0.71%; and the station is sampled by nearest-cell lookup, with the snap distance recorded per probe.
A systematic FFR bias, not noise. FFR increases monotonically with refinement in fifteen of the sixteen cases: coarser meshes over-predict the trans-lesional pressure drop, through numerical dissipation and through the inscribed-polygon deficit that renders the lumen slightly too narrow. Both mechanisms act in one direction, so the effect is a bias. Against the Richardson extrapolate the production-resolution FFR is low by 0.005 at the median case; the worst case is low by 0.114, and it is one of the two non-asymptotic cases, so that figure is an upper envelope on the tail. A surrogate trained on these labels inherits the bias rather than being penalized by it, because the bias is common to training and evaluation labels. At the endpoint the surrogate error (0.008 MAE on RCA, 0.019 on LCA) is roughly eight and nineteen times the median label bias of 0.0010, so the labels are not the binding constraint on either territory; the minimum-pressure proxy would have put the RCA figures within a factor of two of each other, which is why the station matters, and the 0.114 tail means the endpoint comparison should be read as a statement about medians.
Appendix G. Further limitations of the evaluation
Table G.1 collects the limitations listed by name in §6.3, with what each bounds and the measurement that would remove it.
Table G.1: Further limitations of the evaluation (§6.3), each bounding what the reported numbers establish, with the measurement that would remove it.
| Limitation | What it bounds | What would remove it |
|---|---|---|
| Convergence filter precedes the splits (Appendix F) | 9.9% (RCA) and 13.3% (LCA) of completed solves are dropped on residual. Removal tracks mesh quality, so the retained cohort favors geometries the mesher handled cleanly; whether it also selects on stenosis severity is unmeasured | Re-meshing the failed geometries, and the severity distribution of the removed set |
| Flow is developing over much of the tree | against a median LCA centerline of 182 mm, so the nearly-developed-profile argument of §3.1 is weakest proximally, which is also where the error field is largest; we claim no causal link | Inlet extensions, or a spatially resolved residual diagnostic |
| Part of the reference error is geometric, not truncation error | The inscribed-N-gon bias is of the same order as the whole LCA pressure GCI and is inherited by any surrogate, so the GCI is not a floor on measured agreement (Appendix F.1) | A refinement family with an area-preserving radius correction, or vertices projected onto the exact circle at each level |
| The cohort spans non-physiological corners | is drawn independently of caliber, so the smallest LCA inlet (1.32 mm) reaches at the top of the sampled range, three to five times physiological | The joint distribution, and endpoint metrics on the physiological subset |
| Outcome-adjacent filtering of the endpoint subset | Sensitivity analyses use reference FFR , excluding 14 LCA and 7 RCA of the most severe lesions | Metrics separately on the clamped subsets |
| One acquisition source | All anatomies come from one tertiary center via ImageCAS, so cross-vendor and cross-protocol shift is untested | Held-out evaluation on a second CTA+CFD cohort, which needs only centerlines, radii and a flow rate |
| RoPE3D under length extrapolation is untested | If RoPE3D transferred better across territories it would partly reverse the recommendation of §5.2.1 | One evaluation of the existing RoPE3D checkpoint on the other territory |
| Sensitivity analysis covers smooth perturbations only | §5.4.2 establishes local Lipschitz behavior in the geometric arguments; topology-changing perturbations lie outside that parameter set | A segmentation-error model |