arXiv:2610.31160cs.LGOct 2026

Manuscript Offprint

arXiv:2610.31160

Towards Field-Deployable Wearable IMU Systems for Occupational Activity Recognition

Ihsan Ul Haq, James Brusey, Farnad Nasirzadeh, Chandan Karmakar

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Ihsan Ul Haq ∗^{*}

Centre for Computational Science

and Mathematical Modelling

Coventry University, UK

haqi8@uni.coventry.ac.uk

James Brusey

Centre for Computational Science

and Mathematical Modelling

Coventry University, UK

aa3172@coventry.ac.uk

Farnad Nasirzadeh

School of Architecture and

Built Environment

Deakin University, Australia

farnad.nasirzadeh@deakin.edu.au

Chandan Karmakar

School of Information Technology

Deakin University, Australia

karmakar@deakin.edu.au

Abstract—Wearable inertial measurement unit (IMU) systems for construction worker human activity recognition (HAR) routinely report aggregate accuracies above 95%, rarely under genuine subject-independent (leave-one-subject-out (LOSO)) evaluation, masking the per-individual variance that determines real-world deployment performance. Using the VTT-ConIoT benchmark, we conduct, to our knowledge, the first systematic configuration sensitivity analysis of this dataset: six classifiers across five sensor placements and three window sizes under a single LOSO protocol, a personalised-calibration pilot, and a validated comparison of tabular GAN-based and standard time-series augmentation. Per-subject LOSO accuracy for the main multi-sensor, 16-class configuration ranges from 61.9% to 88.7% (mean 77.5%), a 27 pp spread, though all data are laboratory-collected. Multi-sensor fusion and longer windows both improve accuracy; standard augmentation gives small, consistent gains, while Conditional Tabular GAN (CTGAN) augmentation actively harms accuracy with a demonstrated distributional-fidelity mechanism; and personalised calibration recovers 16.8 pp for the weakest participants from just 30% of their own data. These findings provide evidence-grounded configuration guidance for scaling occupational body sensor networks towards field deployment.

Index Terms—body sensor networks; IMU; HAR; construction workers; LOSO; sensor placement; configuration sensitivity; synthetic data augmentation; occupational health; personalised monitoring

I. INTRODUCTION

Work-related musculoskeletal disorders (WMSDs) remain a leading cause of long-term occupational disability in construction, driven by repetitive lifting, awkward postures, and prolonged whole-body vibration [1]. Wearable IMUs, combined with supervised machine learning (ML), offer a scalable, low-cost pathway to continuous in-field ergonomic monitoring. Such systems can classify worker activity with sufficient fidelity to trigger real-time alerts and safety coaching. This is a key step towards the personalised health ecosystems envisioned by the Body Sensor Networks (BSN) community.

The VTT-ConIoT dataset [2] is one of the few publicly available multi-sensor IMU benchmarks designed specifically for construction worker HAR, which has attracted five independent deep-learning studies since its 2022 release [3]–[7], each reporting accuracy up to ≈99%\approx99\% and suggesting that the classification problem is nearly solved. We argue that this conclusion is premature, for two reasons detailed in Section II: most of these figures are not obtained under genuine subject-independent evaluation, and none report per-subject variability. Three critical questions remain for this benchmark, and for construction IMU systems more broadly:

  1. Are high aggregate accuracies stable across individual workers, or do they conceal large per-subject variance?

  2. How do sensor placement, window length, and classifier choice jointly determine field-relevant performance?

  3. Can synthetic data augmentation reduce the per-subject gap for practitioners who cannot collect large cohorts?

Addressing these questions means translating body sensor networks from lab to life: a system with high aggregate accuracy in a controlled setting may still perform unreliably for specific individuals in the field when that aggregate is not subject-independent. This paper makes three contributions:

  1. To our knowledge, the first per-subject LOSO decomposition for the main multi-sensor, 16-class configuration of VTT-ConIoT, quantifying the cross-subject performance spread within this benchmark (Section IV-A).

  2. A systematic configuration sensitivity map, covering sensor placement, window size, and six classifier families, with a hyperparameter-tuning check (Sections IV-B–IV-C) and a personalised-calibration pilot (Section IV-E).

  3. A validated comparison of GAN-based and standard time-series augmentation, clarifying when each is (and is not) likely to help (Section IV-D).