arXiv:2610.31205cs.CVOct 2026

Manuscript Offprint

arXiv:2610.31205

A Visual Grounding Benchmark for Retinal OCT with Multimodal Large Language Models

Ronald Fecso, José Morano, Botond Fazekas, Paul Widmann-Sedlnitzky, Dorota Himel, Laetita Hinterhuber, Virginia Mares, Andreas Pollreisz, Hrvoje Bogunović

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Multimodal large language models (MLLMs) can answer clinical questions about medical images, but trustworthy use requires visual grounding: models should localize the pathology they report rather than rely on spurious shortcuts. Whether MLLMs can visually ground clinical findings in retinal optical coherence tomography (OCT), the most widely used imaging modality in ophthalmology, remains largely unexplored. To address this gap, we introduce RetinaGroundBench, the first benchmark for biomarker visual grounding in retinal OCT. It comprises 815 B-scans exhaustively annotated by ophthalmologists with 4,537 bounding boxes covering 13 biomarkers across 8 diseases. Because MLLMs often fragment a single lesion into multiple partial predictions, we propose AggIoU, a metric that evaluates whether the union of overlapping predicted boxes covers the annotated region. Across 27 open-source MLLMs (0.8–38B parameters), we find that visual grounding remains largely unsolved: the best general-purpose model achieves a macro F1 of just 23.7%, with consistently low recall, despite reaching up to 73% balanced accuracy on biomarker presence questions. To narrow this gap, we developed RetGrounder, an MLLM fine-tuned using an OCT-specific strategy integrating grounding and textual information. Despite its relatively small size (8B), RetGrounder improves grounding F1 to 33.9%, a 43% relative improvement. Our benchmark provides a reference point for measuring progress in the field of OCT diagnosis with MLLMs.

Introduction

Multimodal Large Language Models (MLLMs), which combine language and vision encoders to jointly process images and text, have demonstrated great potential as assistants to ophthalmologists 1−6^{1-6}. The visual question-answering (VQA) ability of these models is of particular interest, as it allows users to query a model about the presence of diseases or lesions in an image 7^{7}. However, for such assistants to be trusted in clinical practice, they must not only answer accurately, but also indicate the visual evidence behind each answer. This capability is known as visual grounding, in which a model outputs the spatial location of a queried finding. Without such grounding, a textual answer gives clinicians no way to confirm that a model attended to the relevant pathology rather than exploiting spurious correlations or learned shortcuts 8^{8}, or simply hallucinating. This lack of verifiability is a central barrier to clinical adoption 9^{9}. Assessing whether current MLLMs can be trusted therefore requires understanding not only their diagnostic question answering ability but also their capacity to spatially localise the pathology underlying those answers.

Most previous studies focused on evaluating MLLMs in terms of examination performance and diagnosis on real clinical cases 1−5^{1-5}. In the former category, frontier models (including GPT-5 10^{10}, Gemini 2.5 Pro 11^{11}, Claude Sonnet 4.0 12^{12}, and DeepSeek-V3 13^{13}) have improved substantially on the Fellowship of the Royal College of Ophthalmologists (FRCOphth) examinations since 2023, with the best-performing model, Gemini 2.5 Pro, exceeding typical top human candidate scores. However, error analysis still revealed critical reasoning deficits such as premature diagnostic closure and confidently unjustified decisions 1^{1}. On real clinical cases, rather than curated examination questions, the evidence is more mixed: on 50 retinal optical coherence tomography (OCT) and OCT angiography (OCT-A) cases, GPT-4o diagnosed 62% correctly versus Gemini's 32% 2^{2}; Med-Gemini surpassed baselines on 18 of 20 medical image classification tasks including ophthalmology 3^{3}; and GPT-4o matched clinicians in differential glaucoma diagnosis on OCT while struggling with primary diagnosis 4^{4}, with further evidence of effective few-shot retinal disease diagnosis on OCT 5^{5}.

Several models have also been developed specifically for ophthalmology. OphGLM 14^{14} was the first, combining ConvNext 15^{15}, BERT 16^{16}, and ChatGLM-6B 17^{17} for fundus diagnostics; VisionUnite 18^{18} added open-ended multi-disease fundus diagnosis with clinical explanations, and EyeCLIP 19^{19}, pre-trained on 2.77 million images across 11 modalities, achieved strong classification and cross-modal retrieval. For OCT specifically, LO-VLM 20^{20} targets anatomical layer-specific interpretation and RetinaVLM 6^{6}, age-related macula degeneration (AMD) staging, approaching junior-ophthalmologist performance. Despite this diversity, these models share a limitation that matters for clinical verification: their outputs are text—a diagnosis, a disease stage, or a free-text description—with no indication of the image evidence behind them. Their scope is narrow as well, and the two OCT-specific models each address a single task. None can be queried for the location of an arbitrary biomarker.

Several ophthalmology-specific VQA benchmarks have been proposed, though none assess visual grounding. LMOD+ 21^{21} is the most systematic, testing 24 MLLMs on 32,633 images across 5 ophthalmic imaging modalities including OCT, but its spatial annotations cover only anatomical structures (e.g., retina, choroid), not fine-grained biomarkers. OphthalmWeChat 22^{22} and MedBench 23^{23} likewise evaluate ophthalmic VQA, and FunBench 24^{24} organises tasks hierarchically across modality, anatomy, lesion, and disease. Across all of these, the performance of MLLMs still lags behind supervised networks, and no benchmark requires models to localise the pathology underlying their answers.

To contextualize existing gaps, prior work can be placed along two hierarchies. The image domain narrows from general medical imaging, through ophthalmology, to retinal OCT specifically; the task deepens from language-only assessment, through VQA on an image, to grounded VQA, in which a model must also localise the finding it reports. Retinal OCT already appears at the shallow end of the task hierarchy—evaluated, in the benchmarks above, as VQA or anatomical recognition, but never biomarker grounding. Grounding, conversely, has been explored further in other specialties—radiology 25^{25}, pathology 26^{26}, and sequential medical images 27^{27}—but not brought down to ophthalmic biomarkers. No prior benchmark occupies the intersection of the two: grounded VQA of biomarkers on retinal OCT, despite it being the most widely used imaging modality in ophthalmology and the diagnostic gold standard for a broad range of retinal diseases.

Purely in terms of data, retinal OCT is well served by classification, segmentation, and lesion detection datasets 28−33^{28-33}, but none supports the task we study. Classification datasets carry no spatial annotation. Segmentation and detection datasets do localise lesions, but their annotations are tied to a closed set of classes fixed in advance rather than to a clinician's query, so they cannot test whether a model retrieves the correct finding when asked in natural language; and their dense-mask output is mismatched to the text coordinates MLLMs emit, so scoring an MLLM against them would measure mask generation rather than spatial grounding.

Grounding retinal OCT biomarkers is not simply the same task in a new modality; three a

References (37)