Manuscript Offprint

arXiv:2610.31505

Evaluation of Uncertainty-Aware Multi-Software Ensembles for Hippocampal Segmentation

Gabriel Oliveira-Stahl, Anna Schroder, James Moggridge, Hamza A. Salhab, Caroline Micallef, Josephine Barnes, M. Jorge Cardoso, Carole H. Sudre, Matthew Grech-Sollars

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Accurate hippocampal segmentation can be a useful tool for diagnosing and monitoring neurological conditions such as Alzheimer's disease and epilepsy. While numerous automated segmentation methods exist, their clinical adoption remains limited. Reliable uncertainty assessment can enhance trust and facilitate clinical translation. This study evaluates ensembles of five heterogeneous hippocampal segmentation methods — InnerEye, ASHS, FastSurfer, HippoSeg, and FreeSurfer — across two dementia datasets and one epilepsy dataset. The sub-ensemble containing InnerEye, FastSurfer, and HippoSeg emerged as both accurate and efficient, highlighting the feasibility of balancing computational cost and performance. Additionally, ensemble-derived uncertainty quantification with sample variance, mutual information, and predictive entropy is shown to reduce inaccurate segmentations by flagging low-confidence cases, potentially providing a mechanism for automatically escalating ambiguous cases for expert assessment. Lastly, this study explores the downstream clinical utility of ensemble-derived uncertainty, finding a significant correlation with motion artefact severity and a modest contribution to Alzheimer's disease classification.

Keywords

Uncertainty estimation, Ensemble, Hippocampal segmentation, Carbon footprint, Alzheimer's disease

Article informations

https://doi.org/10.59275/j.melba.2026-e77b

©2026 Oliveira-Stahl, Schroder, Moggridge, Salhab, Micallef, Barnes, Cardoso, Sudre, and

Grech-Sollars. License: CC-BY 4.0

Volume 2026, Received: 2026-02-24, Published 2026-09-24

Corresponding author: gabriel.stahl.17@ucl.ac.uk

Check for updates

Special issue: Uncertainty for Safe Utilization of Machine Learning in Medical Imaging (UNSURE) 2025

Guest editors: Mobarak Hoque, Raghav Mehta, Cheng Ouyang, Chen Qin, Marianne Rakic, and Sandy Wells

  • Contributed equally as joint senior authors.

1. Introduction

Hippocampal volume changes are associated with several neurological diseases such as Alzheimer's and epilepsy (Jack, 1994; Duan et al., 2020). Accurate volumetric measurement can serve as a biomarker for diagnosis and disease monitoring (Schuff et al., 2008; Briellmann et al., 2002). While manual segmentation by an expert is still considered the gold standard, its time-consuming nature and the well-documented intra- and inter-reader variability remain significant limitations (Boccardi and et al., 2015; Geuze et al., 2005). Although a concerted effort has taken place to establish a harmonised protocol for manual hippocampal segmentation (Frisoni and Jack, 2015), multiple different protocols for hippocampal segmentation exist, complicating the notion of a ground truth segmentation (Geuze et al., 2005).

Numerous methods for automatic hippocampus segmentations have been proposed, ranging from atlas-based approaches (Dill et al., 2015), to deep learning methods (Schroder et al., 2023). Despite the range of available methods, clinical adoption remains limited. Key concerns hindering the clinical translation of these tools include the risk of silent failure, and a lack of robustness to unexpected distribution shifts. Reliable uncertainty estimation can play a central role in strengthening the trustworthiness of these algorithms, e.g. by escalating uncertain cases for human review, and various approaches for assessing predictive uncertainty have been explored in the literature (Abdar and et al., 2020). While Bayesian neural networks offer the most principled framework for posterior approximation, they are often computationally prohibitive (Abdar and et al., 2020). Monte-Carlo Dropout and ensembles have emerged as practical methods for Bayesian approximation (Lakshminarayanan et al., 2016; Gal and Ghahramani, 2015). However, these approaches differ substantially in computational cost. Monte-Carlo sampling increases inference time through repeated stochastic forward passes, while ensemble-based uncertainty quantification (UQ) requires running multiple models or segmentation pipelines, making inference cost scale with ensemble size. This creates an important trade-off between uncertainty reliability, scalability, and computational efficiency, particularly when methods are deployed across large imaging cohorts or resource-constrained clinical environments. Beyond providing uncertainty estimation, ensemble methods consistently achieve superior performance over individual models, as repeatedly demonstrated by results from the Brain Tumor Image Segmentation Benchmark (BRATS) (Menze and et al., 2015) and the White Matter Hyperintensity Segmentation Challenge (Kuijf and et al., 2019). Ensemble predictions can be aggregated through multiple strategies, with stacking of heterogeneous models proving highly effective and simple averaging providing a stable method for integrating their predictions (Müller et al., 2022). Although deep ensembles often outperform single models, their combined outputs are not automatically well-calibrated, even when each constituent network is well-calibrated on its own (Wu and Gales, 2021; Rahaman and Thiery, 2021). Calibration deteriorates further under distribution shift (Ovadia et al., 2019), a problem that has been traced in part to insufficient diversity among ensemble members (Javanbakhat et al., 2024). To counter this, the present study assesses the disagreement of deliberately heterogeneous segmentation methods and treats that disagreement itself as an uncertainty estimate, a strategy previously explored by Kofler et al. (2021).

Another growing concern is the computational cost and energy consumption of the segmentation methods. Recent work has highlighted the potential environmental impact of large-scale deep learning models (Strubell et al., 2020; Wu and et al., 2022), emphasizing the need for sustainable solutions. High computational demands not only contribute to a significant carbon footprint, but also limit accessibility for hospitals and research institutions with limited resources. Addressing both the need for reliable uncertainty estimation and computational efficiency will be conducive for enabling broader clinical adoption.

Beyond performance accuracy, ensembling methods may prove useful to provide robust uncertainty estimates that can be employed for downstream clinical tasks. One such application relates to quality control and particularly motion artefact detection. There are a number of sources that can lead to motion artefacts in brain magnetic resonance imaging (MRI), including patient movement, involuntary physiological motion (e.g., respiration and cardiac pulsation), swallowing, and flow of fluids such as blood or cerebrospinal fluid (Zaitsev et al., 2015). Motion artefacts can negatively impact image quality and lead to erroneous interpretations, in particular in acquisitions with low signal-to-noise ratio (Havsteen et al., 2017). Accurately detecting and correcting motion-related image degradation has long been a challenge in medical image processing (Zaitsev et al., 2015). While both traditional machine learning and deep-learning-based methods have demonstrated strong performance (Vakli et al., 2023), their effectiveness often does not generalise well across vendors or acquisition protocols. Segmentation uncertainty, which tends to increase as image quality degrades, may therefore offer a complementary signal for flagging motion-corrupted scans, with previous work showing that ensemble-derived uncertainties are particularly useful for quality control (Ng et al., 2023).

A further potential application of uncertainty estimation in the context of hippocampal segmentation is disease classification. Previous work has shown that hippocampal volume can discriminate Alzheimer's disease (AD) from mild cognitive impairment (MCI) and cognitively normal (CN) subjects with approximately 84% sensitivity and specificity (Colliot et al., 2008), and a recent meta-analysis of artificial intelligence (AI)-based methods-based methods reports high performance for AD vs. CN (sensitivity: 0.87, specificity: 0.91, AUC: 0.95), though accuracy decreases for AD vs. MCI (AUC: 0.80) and MCI vs. CN (AUC: 0.83) (Wu et al., 2025). Leveraging epistemic uncertainty, we hypothesise that disagreements between methods designed to accommodate atrophy and methods trained purely on healthy individuals will be stronger in the AD cases with stronger hippocampal atrophy. If confirmed, such disagreement could serve as an additional feature for classification.

References (46)